Send an Inquiry

To receive a quote for your project, please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Part Number*
Quantity*
Message
Submit Inventory List

Please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Upload My List
Message

AC DC Configurable Power Supply Chassis

Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status User Configuration Type Number of Positions Voltage - Input Power (Watts) Voltage - Isolation Efficiency Features Operating Temperature Size / Dimension Height Approval Agency Standard Number
XLCC0

XLCC0

CONFIGURABLE POWER SUPPLY

EXCELSYS / Advanced Energy

4,959 267.84
RFQ
XLCC0

Datasheet

Xgen, XL Box Active - Standard 4 85 ~ 264 VAC 600 W 3 kV 89% Fan Fail, Temperature Alarm -20°C ~ 70°C (With Derating) 10.24" L x 3.50" W (260.0mm x 89.0mm) 1.59" (40.40mm) CE, cURus -
XLD-D1

XLD-D1

CONFIGURABLE POWER SUPPLY

EXCELSYS / Advanced Energy

2,213 305.65
RFQ
XLD-D1

Datasheet

Xgen, XL Box Active - Standard 4 85 ~ 264 VAC 750 W 4 kV 90% Fan Fail, Temperature Alarm -20°C ~ 70°C (With Derating) 10.55" L x 3.50" W (268.0mm x 89.0mm) 1.59" (40.40mm) CE, cURus -
XKB-02

XKB-02

CONFIGURABLE POWER SUPPLY

EXCELSYS / Advanced Energy

3,785 299.79
RFQ
XKB-02

Datasheet

Xgen, XK Box Active - Standard, Low Noise 4 85 ~ 264 VAC 400 W 3 kV 89% Fan Fail, Temperature Alarm -20°C ~ 70°C (With Derating) 10.24" L x 3.50" W (260.0mm x 89.0mm) 1.59" (40.40mm) CE, cURus -
XLD-D3

XLD-D3

CONFIGURABLE POWER SUPPLY

EXCELSYS / Advanced Energy

2,552 324.01
RFQ
XLD-D3

Datasheet

Xgen, XL Box Active - Standard 4 85 ~ 264 VAC 750 W 4 kV 90% Fan Fail, Temperature Alarm -20°C ~ 70°C (With Derating) 10.55" L x 3.50" W (268.0mm x 89.0mm) 1.59" (40.40mm) CE, cURus -
UX4-D2

UX4-D2

CONFIGURABLE POWER SUPPLY

EXCELSYS / Advanced Energy

1,523 268.19
RFQ
UX4-D2

Datasheet

UltiMod, UX Box Active - Medical 4 85 ~ 264 VAC 600 W 4 kV 90% Fan Fail, Temperature Alarm -40°C ~ 70°C (With Derating) 10.24" L x 3.50" W (260.0mm x 89.0mm) 1.59" (40.40mm) CE, cURus -
XRB-01

XRB-01

CONFIG POWER CHASSIS

EXCELSYS / Advanced Energy

2,971 331.95
RFQ
XRB-01

Datasheet

Xgen, XR Box Active - Medical, Low Noise 4 85 ~ 264 VAC 400 W 4 kV 89% Fan Fail, Temperature Alarm -20°C ~ 70°C (With Derating) 10.24" L x 3.50" W (260.0mm x 89.0mm) 1.59" (40.40mm) CE, cURus -
XLDSD3

XLDSD3

CONFIGURABLE POWER SUPPLY

EXCELSYS / Advanced Energy

1,726 348.89
RFQ
XLDSD3

Datasheet

Xgen, XL Box Active - Standard 4 85 ~ 264 VAC 750 W 4 kV 90% Fan Fail, Temperature Alarm -20°C ~ 70°C (With Derating) 10.55" L x 3.50" W (268.0mm x 89.0mm) 1.59" (40.40mm) CE, cURus -
XLCCD1

XLCCD1

CONFIG POWER CHASSIS 600W 4 SLOT

EXCELSYS / Advanced Energy

1,396 275.40
RFQ
XLCCD1

Datasheet

Xgen, XL Bulk Active - Standard 4 85 ~ 264 VAC, 120 ~ 380 VDC 600 W 3 kV 89% Conformal Coating, Fan Fail, Reverse Fan, Ruggedized, Temperature Alarm -20°C ~ 70°C (With Derating) 10.24" L x 3.50" W (260.0mm x 89.0mm) 1.59" (40.40mm) CE, cURus -
UX6-D2

UX6-D2

CONFIGURABLE POWER SUPPLY

EXCELSYS / Advanced Energy

4,784 329.87
RFQ
UX6-D2

Datasheet

UltiMod, UX Box Active - Medical 6 85 ~ 264 VAC 1200 W 4 kV 90% Fan Fail, Temperature Alarm -40°C ~ 70°C (With Derating) 10.24" L x 5.00" W (260.0mm x 127.0mm) 1.59" (40.40mm) CE, cURus -
XMC-02

XMC-02

CONFIGURABLE POWER SUPPLY

EXCELSYS / Advanced Energy

3,792 294.51
RFQ
XMC-02

Datasheet

Xgen, XM Box Active - Medical 4 85 ~ 264 VAC 600 W 4 kV 89% Fan Fail, Temperature Alarm -20°C ~ 70°C (With Derating) 10.24" L x 3.50" W (260.0mm x 89.0mm) 1.59" (40.40mm) CE, cURus -
Total 1450 Record«Prev1... 56789101112...145Next»
Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER