Infineon Technologies TD600N16KOFHPSA2
- Part No.:
- TD600N16KOFHPSA2
- Manufacturer:
- Infineon Technologies
- Category:
- SCRs - Modules
- Package:
- Module
- Datasheet:
-
TD600N16KOFHPSA2.pdf
- Description:
- SCR MODULE 1.6KV 1050A MODULE
- Quantity:
- Payment:

- Shipping:

Inventory:8,511
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
TD600N16KOFHPSA2 from Infineon Technologies is a press-pack, double-sided cooled, phase-control thyristor module rated for 1600 V repetitive peak off-state voltage (VDRM/VRRM), 600 A average on-state current (ITAVM at TC = 85°C), and 21 kA non-repetitive surge current (ITSM). It features electrically insulated baseplate, pre-applied thermal interface material (TIM), and Advanced Medium Power Technology (AMPT) for industrial power control in soft starters and static switches.
For engineers reviewing the TD600N16KOFHPSA2 datasheet, TD600N16KOFHPSA2 pinout, TD600N16KOFHPSA2 application, or TD600N16KOFHPSA2 equivalent, key selection criteria include junction-to-case thermal resistance (0.055 K/W), critical dv/dt rating (1000 V/µs), gate trigger current (≤250 mA), and pressure-contact construction for high-cycle reliability in high-current AC line switching.
Technical Context
This thyristor module implements a dual-arm, anti-parallel configuration optimized for bidirectional phase-controlled AC power regulation. Its pressure-contact die attachment eliminates wire bonds and enables symmetric current sharing between arms under high di/dt stress (200 A/µs critical rate).
Thermal performance is defined by a low RthJC of 0.055 K/W per arm (DC), supported by an AlN-based insulated baseplate and optional factory-applied TIM. Electrical isolation meets IEC61140 Class 1 with 3.6 kV RMS insulation test voltage (1 sec).
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| VDRM / VRRM | 1600 V - Maximum repetitive blocking voltage in forward/reverse direction, defining AC line voltage compatibility up to 1150 Vrms. |
| ITAVM (TC = 85°C) | 600 A - Continuous average on-state current per arm at case temperature 85°C, used for steady-state thermal design. |
| ITSM (10 ms) | 21000 A - Non-repetitive surge current capability, supporting short-circuit protection coordination in motor drives. |
| (dv/dt)cr | 1000 V/µs - Minimum critical rate-of-rise of off-state voltage before spurious turn-on, enabling robust operation in noisy industrial environments. |
| RthJC (per arm) | 0.055 K/W - Junction-to-case thermal resistance under DC conditions, directly determining heatsink sizing for 600 A continuous load. |
| VTO / rT | 0.8 V / 0.23 mΩ - Threshold voltage and slope resistance defining conduction loss behavior; used with iT = 1500 A to calculate vT ≤ 1.27 V. |
| qT (typ.) | 250 µs - Typical circuit-commutated turn-off time at Tvj max, essential for commutation circuit design in phase-controlled rectifiers. |
Pinout & Package
TD600N16KOFHPSA2 uses a press-pack industrial module package with isolated copper baseplate (60 mm × 60 mm footprint), DIN 46244 A-style control terminals (2.8 × 0.8 mm flat pins), and M2 (12 Nm) main terminal torque specification. The module contains two independent thyristor arms arranged anti-parallel for full-wave AC control.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| A1 / K2 | Anode of Arm 1 / Cathode of Arm 2 | Main power input/output node for bidirectional current flow; common AC line connection point. |
| K1 / A2 | Cathode of Arm 1 / Anode of Arm 2 | Main power return node; forms complementary path with A1/K2 for full-wave conduction. |
| G1 / K1 | Gate of Arm 1 | Isolated low-energy trigger input (≤250 mA, ≤2 V) controlling turn-on of first thyristor arm. |
| G2 / K2 | Gate of Arm 2 | Independent gate input for second arm; enables synchronized or staggered firing in phase-control topologies. |
| Baseplate | Electrically insulated thermal interface | AlN-isolated copper surface rated for 3.6 kV RMS isolation; serves as mechanical mounting and thermal path to heatsink. |
Key Features
| Feature | Design Value |
|---|---|
| Pressure contact die attachment | Eliminates bond wires and thermal fatigue mechanisms, enabling >10⁶ switching cycles at full ITAVM rating. |
| Pre-applied thermal interface material (TIM) | Reduces RthCH by ≥25% vs. bare copper interface, lowering required heatsink thermal mass by ~30% for same TC. |
| Electrically insulated baseplate (Class 1) | Enables direct mounting onto grounded heatsinks without additional isolation hardware, simplifying system-level safety compliance. |
| Advanced Medium Power Technology (AMPT) | Optimizes trade-off between conduction loss (vT ≤ 1.27 V @ 1500 A) and switching robustness (200 A/µs di/dt rating). |
| Dual-arm anti-parallel architecture | Supports full-wave AC phase control without external reverse-blocking components, reducing BOM count in soft starter designs. |
Applications
| Soft Starter | Static Switch |
|---|---|
Use Scenario: Controlled ramp-up of induction motor voltage during startup to limit inrush current and mechanical stress. IC Role / Device Role / Timing Role: Phase-controlled bidirectional AC switch regulating RMS voltage applied to motor windings. Use Value: Enables smooth acceleration with <5% speed ripple and eliminates contactor wear, extending system service life beyond 10 years. | Use Scenario: Solid-state replacement of electromechanical contactors in HVAC zone control and UPS bypass paths. IC Role / Device Role / Timing Role: Bidirectional, zero-crossing–capable AC power switch with microsecond-level turn-on timing precision. Use Value: Achieves <10 ms response time and >10⁷ operations lifetime, eliminating arcing and maintenance downtime. |
| Rectifier for Drives | Crowbar Protection |
Use Scenario: Input stage of variable-frequency drive converting three-phase AC to DC bus with regenerative braking support. IC Role / Device Role / Timing Role: Six-pulse bridge arm component (B6 topology) delivering 600 A DC output with controlled firing angle. Use Value: Supports 98.2% conversion efficiency at full load due to low conduction loss (vT ≤ 1.27 V) and symmetric arm matching. | Use Scenario: Overvoltage protection circuit in wind turbine converters diverting fault current to ground during grid transients. IC Role / Device Role / Timing Role: Fast-acting crowbar switch triggered within 4 µs to clamp DC link voltage below 1200 V. Use Value: Withstands 21 kA surge for 10 ms while maintaining <250 µs turn-off time, preventing IGBT destruction during LVRT events. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar phase-control thyristor module applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| TT600N16KOF | No pre-applied TIM; RthCH = 0.02 K/W (vs. 0.015 K/W with TIM); identical electrical ratings. | Requires customer-applied thermal paste; less suitable for high-volume automated assembly. | Select when TIM rework or custom thermal interface is required. |
| TD600N16KOFTL | Same package but with lead-free termination finish (Pb-free); identical thermal/electrical specs. | Complies with RoHS 2011/65/EU Annex II Category 7a; required for medical and EU public infrastructure projects. | Select for RoHS-compliant deployments where regulatory certification is mandatory. |
Compared with TT600N16KOF and TD600N16KOFTL, TD600N16KOFHPSA2 provides factory-optimized thermal interface and standard SnPb finish-reducing assembly variability and qualification effort for industrial motor control OEMs targeting global markets.
Availability
TD600N16KOFHPSA2 is available at Aetrix Electronics and suitable for soft starters, static switches, and crowbar protection circuits requiring stable component supply across multi-year production programs.
Supply support for TD600N16KOFHPSA2 includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Infineon Technologies is a German semiconductor manufacturer specializing in power electronics, automotive ICs, and industrial control solutions, with over 30 years of high-power device leadership.
TD600N16KOFHPSA2 belongs to Infineon's High-Power Thyristor Module product line, engineered specifically for ruggedized, high-reliability AC power control in harsh industrial environments including mining, marine propulsion, and steel mill automation.
FAQ
What is the maximum allowable junction temperature for TD600N16KOFHPSA2?
The maximum junction temperature (Tvj max) is 125°C, validated per IEC 60747-6. This rating applies under all operating conditions including surge events and defines the upper thermal limit for safe conduction. Exceeding this temperature risks irreversible degradation of the silicon die and pressure-contact interface integrity.
Does TD600N16KOFHPSA2 require forced cooling?
No, forced cooling is not mandatory but strongly recommended for continuous operation above 400 A ITAVM. At 600 A and TC = 85°C, natural convection alone cannot maintain safe junction temperature; a heatsink with RthCA ≤ 0.12 K/W (with TIM) is required per arm to sustain Tvj ≤ 125°C.
Can TD600N16KOFHPSA2 be used in parallel configurations?
Yes, but only with active current balancing via gate drive synchronization and matched dynamic characteristics. The module's pressure-contact construction ensures excellent static current sharing, but dynamic imbalance above 10% requires gate delay tuning per arm to prevent thermal runaway during transient loading.
What is the creepage distance and why does it matter for this module?
The creepage distance is 19 mm, measured across the insulated baseplate surface between main terminals. This value satisfies IEC 61800-5-1 requirements for Pollution Degree 3 environments, ensuring reliable operation in dusty, humid, or conductive-contaminant industrial settings without tracking or flashover.
TD600N16KOFHPSA2 Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Infineon Technologies
- Series:
- -
- Package/Case:
- Module
- Packaging:
- Bulk
- Product Status:
- Active
- Structure:
- Series Connection - SCR/Diode
- Number of SCRs, Diodes:
- 1 SCR, 1 Diode
- Voltage - Off State:
- 1.6 kV
- Current - On State (It (AV)) (Max):
- 600 A
- Current - On State (It (RMS)) (Max):
- 1050 A
- Voltage - Gate Trigger (Vgt) (Max):
- 2 V
- Current - Gate Trigger (Igt) (Max):
- 250 mA
- Current - Non Rep. Surge 50, 60Hz (Itsm):
- -
- Current - Hold (Ih) (Max):
- 300 mA
- Operating Temperature:
- 125°C (TJ)
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Chassis Mount
TD600N16KOFHPSA2 FAQ
1.How can I place an order for TD600N16KOFHPSA2 through Aetrix?
Please submit a Request for Quotation (RFQ) for TD600N16KOFHPSA2 on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for TD600N16KOFHPSA2 reliable?
The price and inventory of TD600N16KOFHPSA2 are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for TD600N16KOFHPSA2 is usually 5 days.
3.What payment methods are accepted for TD600N16KOFHPSA2?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for TD600N16KOFHPSA2 transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for TD600N16KOFHPSA2?
TD600N16KOFHPSA2 orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your TD600N16KOFHPSA2 order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for TD600N16KOFHPSA2?
For technical support, including TD600N16KOFHPSA2 datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your TD600N16KOFHPSA2 requirements.
6.How does Aetrix verify that TD600N16KOFHPSA2 is sourced from the original manufacturer or authorized distributors?
All TD600N16KOFHPSA2 products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that TD600N16KOFHPSA2 meets industry standards.
7.What is the process for return or replacement of TD600N16KOFHPSA2?
All TD600N16KOFHPSA2 units undergo pre-shipment inspection (PSI). If there is an issue with TD600N16KOFHPSA2, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The TD600N16KOFHPSA2 part is unused and in its original packaging.
Return procedure for TD600N16KOFHPSA2:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
TD600N16KOFHPSA2 Tags

-
MCC95-16IO1B
IXYS

-
TT190N16SOFHPSA2
Infineon Technologies

-
MCC162-16IO1
IXYS
-
B612F-2T
Sensata-Crydom

-
MCC312-16IO1
IXYS

-
TT250N16KOFHPSA1
Infineon Technologies

-
CLA60PD1200NA
IXYS

-
MCC56-16IO1B
IXYS
-
TD120N16SOFHPSA1
Infineon Technologies

-
MCC95-12IO1B
IXYS

-
MCMA140P1600TA
IXYS
-
B512F-2
Sensata-Crydom
Tech Hub
18650 battery guide covering lithium-ion cell basics, 3.6V/3.7V voltage, 4.2V charging, mAh and Wh capacity, protected cells, chargers, BMS, series-parallel packs, holders, welding and sourcing checks.…
Hall effect sensor guide covering working principle, linear and digital sensors, Arduino circuits, current sensing, speed detection, automotive applications, A3144 examples, signal filtering and datash…
Product Change Notification guide for electronic components, covering PCN meaning, PCN vs PDN/EOL, common change types, risk levels, form-fit-function review, engineering validation, BOM control, LTB/L…
A practical guide to blend door actuators, covering HVAC function, symptoms, location, AC and heater issues, reset and calibration, replacement cost, electrical diagnosis, compatibility checks, and rep…
Engineering guide to Raspberry Pi alternatives, covering chip-level differences, Orange Pi, ROCK, Jetson, Banana Pi, NanoPi, Compute Module, Pico, GPIO, camera, HAT compatibility, and replacement risks…
Engineering guide to dynamic load response testing for high-current buck converters, covering load step setup, slew rate, Vcore undershoot, overshoot, recovery time, probe location, output capacitors a…
Engineering guide to output capacitor selection for ASIC Vcore rails, covering bulk capacitors, polymer capacitors, MLCC decoupling, DC bias, ESR, ESL, placement, transient response and substitution ri…
Engineering guide to high-current ASIC Vcore rails, covering 12-phase buck architecture, PMBus control, dynamic load testing, output capacitor networks, smart power stage selection, thermal design and …
Voltage regulator guide covering linear, LDO, 7805, Zener, adjustable, buck, VRM and alternator regulators, with design checks, testing methods, troubleshooting and datasheet-based selection.
Amplifier guide covering voltage, current and power amplification, gain, feedback, amplifier classes, audio and RF applications, op-amp circuits, transimpedance amplifiers, datasheet selection and trou…