Melexis Technologies NV MLX90324LGO-DBO-000-RE
- Part No.:
- MLX90324LGO-DBO-000-RE
- Manufacturer:
- Melexis Technologies NV
- Category:
- Angle, Linear Position Measuring
- Package:
- 16-TSSOP (0.173", 4.40mm Width)
- Datasheet:
-
MLX90324LGO-DBO-000-RE.pdf
- Description:
- SENSOR ROTARY 360DEG SMD
- Quantity:
- Payment:

- Shipping:

Inventory:1,334
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MLX90324LGO-DBO-000-RE from Melexis is a TSSOP-16 packaged, dual-die redundant absolute rotary position sensor IC using Triaxis® Hall technology. It delivers 12-bit angular resolution, supports SENT (SAE-J2716), analog ratiometric, and PWM output modes, and operates across −40°C to +150°C for under-the-hood automotive applications such as throttle and EGR actuators.
For engineers reviewing the MLX90324LGO-DBO-000-RE datasheet, pinout, applications, or equivalent options, key selection criteria include its dual-die redundancy, SENT protocol compliance, programmable 16-point transfer curve, ±700 mT magnetic tolerance, and integrated self-diagnostic features per ISO 26262 ASIL-B readiness.
Technical Context
The MLX90324LGO-DBO-000-RE implements Triaxis® sensing via two orthogonal Hall plate pairs with an Integrated Magneto-Concentrator (IMC), enabling precise measurement of in-plane magnetic flux (BX/BY) for full 360° angular decoding. Its DSP computes arctangent via lookup table-not CORDIC-ensuring intrinsic thermal compensation against airgap and magnet aging effects.
It integrates a 16-bit RISC microcontroller (2.5 MIPS @ 10 MHz), 10 kB ROM, 256 B RAM, and 128 B EEPROM with Hamming ECC. Output conditioning includes configurable FIR/IIR filtering, programmable clamping, deadzone, and hysteresis, with diagnostics covering VDD/VSS fault detection, resonance monitoring, and EEPROM integrity.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Angular Resolution | 12-bit (0.0879°/LSB), enabling high-fidelity position feedback in closed-loop control systems |
| Thermal Accuracy | 10-bit over temperature (±0.3° max error at 150°C), critical for engine bay reliability |
| Operating Temp | −40°C to +150°C (L-grade), qualified for under-hood automotive environments |
| Output Protocols | SENT (SAE-J2716), ratiometric analog, and PWM-supports legacy and next-gen ECU interfaces |
| Magnetic Range | ±700 mT, compatible with standard diametrically magnetized NdFeB magnets at typical airgaps |
| Redundancy | Dual-die architecture (TSSOP-16), providing functional safety support for ASIL-B applications |
| Supply Current | 10–15 mA (medium/fast mode), optimized for low-power ECU subsystems |
Pinout & Package
TSSOP-16 package (GO code), RoHS-compliant, with dual-die redundancy and IMC positioned for optimal in-plane field sensitivity. Unused and test pins must be grounded for EMC compliance per datasheet Section 4.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1, 11 | VDD1 / VDD2 | Independent power rails for each die-enables fault-isolated supply domains |
| 2, 10 | VSS1 / VSS2 | Separate ground returns per die-supports differential diagnostics and noise rejection |
| 5, 15 | Out1 / Out2 | Redundant SENT/analog/PWM outputs-allows cross-checking and fail-safe reporting |
| 13 | Switch Out1 | Programmable angular switch output-configurable hysteresis and deadzone for threshold events |
| 4, 6, 8, 12, 14, 16 | Test 01 / Test 12 / etc. | Factory test and programming nodes-must be tied to ground in final design per Section 4 |
Key Features
| Feature | Design Value |
|---|---|
| Triaxis® IMC Sensing | Enables true 360° absolute angle measurement using only in-plane flux-no external concentrators needed |
| 16-Point Transfer Curve | Allows end-user calibration to compensate for mechanical/magnetic non-idealities in custom assemblies |
| SENT Protocol Compliance | Meets SAE-J2716 Rev 2016-supports high-resolution, low-jitter digital transmission to modern ECUs |
| Dual-Die Redundancy | Provides hardware-level fault tolerance-critical for ASIL-B throttle/EGR position sensing |
| Integrated Diagnostics | Covers VDD/VSS faults, EEPROM ECC errors, resonance detection, and signal path integrity |
Applications
| Throttle Position Sensing | EGR Valve Actuation |
|---|---|
Use Scenario: Real-time angular feedback of throttle blade rotation in gasoline/diesel engines under transient load and high under-hood temperatures. IC Role / Device Role / Timing Role: Absolute rotary position sensor delivering SENT-encoded angle data synchronized to ECU sampling clocks. Use Value: Enables precise air-fuel ratio control and torque management with <±0.3° thermal error up to 150°C ambient. | Use Scenario: Closed-loop positioning of exhaust gas recirculation valves exposed to hot, corrosive exhaust streams and vibration. IC Role / Device Role / Timing Role: Redundant angular transducer feeding dual-channel ECU inputs for fault-tolerant emission control. Use Value: Dual-die architecture ensures continued operation during single-point failure-meeting ASIL-B requirements. |
| Non-Contacting Potentiometer | EMS Actuator Feedback |
Use Scenario: Replacement of wear-prone mechanical potentiometers in industrial valve positioners and robotic joints. IC Role / Device Role / Timing Role: Contactless angular encoder generating ratiometric analog or PWM output compatible with legacy PLC analog inputs. Use Value: Eliminates mechanical wear and contact bounce-providing >100M cycle lifetime with stable linearity over temperature. | Use Scenario: Position feedback for electric motor-driven intake manifold flaps, turbo vanes, and variable geometry components. IC Role / Device Role / Timing Role: High-speed angular sensor supporting fast PWM or SENT updates (≤330 µs sampling) for dynamic actuator control. Use Value: Fast mode timing enables real-time correction loops with <1.2 ms step response-critical for transient emissions compliance. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar absolute rotary position sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MLX90316LGO-DBC-000-RE | Single-die TSSOP-16, no redundancy; lacks SENT; max 125°C operating range | Suitable for non-safety-critical, lower-temp applications like HVAC dampers | Select when cost and temperature margin outweigh redundancy and protocol needs |
| AS5055A-DSOM | Single-die, SPI interface only; 14-bit resolution; −40°C to +125°C; no built-in diagnostics | Targeted at industrial encoders where SPI host exists and ASIL compliance not required | Choose for higher resolution in benign environments without SENT or dual-die demands |
Compared with MLX90316LGO-DBC-000-RE and AS5055A-DSOM, the MLX90324LGO-DBO-000-RE uniquely combines dual-die redundancy, SENT protocol, and 150°C operation-making it the only option qualified for ASIL-B throttle/EGR position sensing in modern powertrain systems.
Availability
MLX90324LGO-DBO-000-RE is available at Aetrix Electronics and suitable for automotive powertrain control, industrial valve actuation, and high-reliability rotary feedback systems requiring stable component supply across extended temperature ranges and long production lifecycles.
Supply support for MLX90324LGO-DBO-000-RE includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Melexis is a Belgian semiconductor company specializing in intelligent sensors and driver ICs for automotive and industrial markets, with core expertise in magnetic sensing and embedded signal processing.
The MLX90324 product line targets harsh-environment "under-the-hood" applications, delivering robust, programmable, and safety-ready rotary position sensing through Triaxis® technology and SENT interface integration.
FAQ
What output protocols does the MLX90324LGO-DBO-000-RE support?
The MLX90324LGO-DBO-000-RE supports three user-selectable output protocols: SENT (SAE-J2716 compliant), ratiometric analog voltage, and PWM. Each mode is programmable via EEPROM and can be configured independently for resolution, frequency, clamping, and diagnostic behavior. The SENT mode delivers 12-bit angular data plus status bits in standardized nibble format, while analog and PWM outputs provide backward compatibility with legacy ECU analog inputs.
How is redundancy implemented in the MLX90324LGO-DBO-000-RE?
The MLX90324LGO-DBO-000-RE uses physically separate dual dies in a single TSSOP-16 package, each with independent VDD/VSS pins, signal paths, and output drivers (Out1/Out2, Switch Out1/Switch Out2). This architecture allows cross-comparison of outputs and detection of single-die faults-supporting ASIL-B functional safety requirements without external circuitry. Isolation resistance between dies exceeds 4 MΩ per specification.
Can the MLX90324LGO-DBO-000-RE be programmed in-system?
Yes, the MLX90324LGO-DBO-000-RE supports in-system programming via its supply (VDD/VSS) and output (OUT) pins-no dedicated programming pins are required. Configuration is performed using the Melexis PTC-04 programmer with MLX90316/90324 daughterboard and associated DLL software. All parameters-including transfer curve, SENT settings, diagnostics, and ID numbers-are stored in 128 B EEPROM with Hamming ECC for integrity.
What is the angular accuracy of the MLX90324LGO-DBO-000-RE over temperature?
The MLX90324LGO-DBO-000-RE achieves 10-bit angular thermal accuracy (±0.3° maximum error) across its full −40°C to +150°C operating range. This performance stems from intrinsic ATAN-based computation on BX/BY ratios, which cancels common-mode flux variations due to temperature drift, airgap change, or magnet aging. Intrinsic linearity error is ±1° at 25°C, further correctable via 16-point user calibration.
Does the MLX90324LGO-DBO-000-RE require an external magnet, and what type is recommended?
Yes, the MLX90324LGO-DBO-000-RE requires an external diametrically magnetized permanent magnet placed above the IC surface. Melexis recommends NdFeB magnets with Br ≥ 1.2 T and operating temperature rating ≥ 150°C. The magnetic specification confirms operation up to ±700 mT; exceeding this may saturate the IMC and degrade linearity. Optimal airgap is 1–3 mm depending on magnet size and required angular range.
MLX90324LGO-DBO-000-RE Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Melexis Technologies NV
- Package/Case:
- 16-TSSOP (0.173", 4.40mm Width)
- Series:
- Triaxis®
- Packaging:
- Tape & Reel (TR)
- Product Status:
- Active
- Programmable:
- -
- For Measuring:
- Rotary Position
- Technology:
- Hall Effect
- Rotation Angle - Electrical, Mechanical:
- 0° ~ 360°, Continuous
- Linear Range:
- -
- Output:
- Analog Voltage, PWM, SENT
- Output Signal:
- -
- Actuator Type:
- External Magnet, Not Included
- Linearity:
- ±1°
- Resistance:
- -
- Resistance Tolerance:
- -
- Voltage - Supply:
- 4.5V ~ 5.5V
- Mounting Type:
- Surface Mount
- Termination Style:
- Gull Wing
- Operating Temperature:
- -40°C ~ 150°C
- Grade:
- -
- Qualification:
- -
- Supplier Device Package:
- 16-TSSOP
MLX90324LGO-DBO-000-RE FAQ
1.How can I place an order for MLX90324LGO-DBO-000-RE through Aetrix?
Please submit a Request for Quotation (RFQ) for MLX90324LGO-DBO-000-RE on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MLX90324LGO-DBO-000-RE reliable?
The price and inventory of MLX90324LGO-DBO-000-RE are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MLX90324LGO-DBO-000-RE is usually 5 days.
3.What payment methods are accepted for MLX90324LGO-DBO-000-RE?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MLX90324LGO-DBO-000-RE transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MLX90324LGO-DBO-000-RE?
MLX90324LGO-DBO-000-RE orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MLX90324LGO-DBO-000-RE order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MLX90324LGO-DBO-000-RE?
For technical support, including MLX90324LGO-DBO-000-RE datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MLX90324LGO-DBO-000-RE requirements.
6.How does Aetrix verify that MLX90324LGO-DBO-000-RE is sourced from the original manufacturer or authorized distributors?
All MLX90324LGO-DBO-000-RE products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MLX90324LGO-DBO-000-RE meets industry standards.
7.What is the process for return or replacement of MLX90324LGO-DBO-000-RE?
All MLX90324LGO-DBO-000-RE units undergo pre-shipment inspection (PSI). If there is an issue with MLX90324LGO-DBO-000-RE, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MLX90324LGO-DBO-000-RE part is unused and in its original packaging.
Return procedure for MLX90324LGO-DBO-000-RE:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MLX90324LGO-DBO-000-RE Tags

-
TLV493DA1B6HTSA2
Infineon Technologies
-
EVW-AE4001B14
Panasonic Electronic Components

-
3382G-1-103G
Bourns Inc.

-
TLE5501E0001XUMA1
Infineon Technologies

-
HAL830UT-A
TDK-Micronas GmbH

-
TLE5009E1000FUMA1
Infineon Technologies

-
TLE5501E0002XUMA1
Infineon Technologies

-
HAL3725DJ-A
TDK-Micronas GmbH

-
HAL3727DJ-A
TDK-Micronas GmbH
-
HMC1501-TR
Honeywell Aerospace
-
HMC1512-TR
Honeywell Aerospace

-
AAS33001LLEATR-5
Allegro MicroSystems
Tech Hub
Comparator circuit design covering voltage thresholds, input limits, open-collector outputs, LM393 wiring, op-amp differences, hysteresis, timing, window detection and practical fault diagnosis.
Schmitt triggers use separate rising and falling thresholds to stabilize slow or noisy signals. This guide covers hysteresis, 74HC14 and 74HCT14 selection, comparator calculations, RC oscillators and p…
Counterfeit components can hide behind convincing markings and passing basic function tests. This engineering reference covers source traceability, external inspection, X-ray, XRF, electrical testing, …
A practical engineering and sourcing framework covering lifecycle verification, lifetime-buy calculations, replacement qualification, supplier checks and counterfeit-risk controls.
TTL and CMOS logic families differ in thresholds, loading, output drive, power and timing. This engineering guide compares 74HC and 74HCT, calculates noise margins and checks 3.3 V/5 V compatibility.
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …