Melexis Technologies NV MLX90333LGO-BCH-100-SP
- Part No.:
- MLX90333LGO-BCH-100-SP
- Manufacturer:
- Melexis Technologies NV
- Category:
- Linear, Compass (ICs)
- Package:
- 16-TSSOP (0.173", 4.40mm Width)
- Datasheet:
-
MLX90333LGO-BCH-100-SP.pdf
- Description:
- SENSOR HALL EFFECT SPI 16TSSOP
- Quantity:
- Payment:

- Shipping:

Inventory:3,248
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MLX90333LGO-BCH-100-SP from Melexis is a Triaxis® 3D contactless position sensor IC in TSSOP-16 package, featuring dual-die redundancy, 12-bit angular resolution, programmable analog/PWM/serial output modes, and ±4 T magnetic field tolerance for joystick, linear stroke, and rotary position sensing in automotive and industrial environments.
For engineers reviewing the MLX90333LGO-BCH-100-SP datasheet, pinout, applications, or equivalent options, this page delivers verified technical context, calibrated transfer characteristics, dual-die isolation specs, SPI interface timing, and real-world MMI use-case validation - all grounded in Melexis Revision 008 documentation.
Technical Context
The MLX90333LGO-BCH-100-SP integrates two independent silicon dies in one TSSOP-16 package, each with Triaxis® Hall sensing (BX/BY via IMC, BZ via conventional Hall plate), 16-bit RISC DSP, 128 B EEPROM, and configurable output stages. It supports simultaneous dual-output reporting in 3D joystick mode with independent OUT1/OUT2 channels.
Its serial protocol uses 3-wire SPI (MOSI/MISO/SCLK) with /SS slave select, enabling host-controlled calibration of Alpha/Beta transfer curves, clamping levels, dead zones, and diagnostic thresholds. The device operates across -40°C to +150°C with 4 MΩ inter-die isolation and programmable filter coefficients (FIR/IIR) for vibration-resistant angle calculation.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Output Modes | Ratiometric analog, PWM (100–1000 Hz), or 3-wire SPI - selectable per channel for mixed-signal system integration |
| Angular Resolution | 12-bit (0.088°/LSB theoretical), with 10-bit thermal accuracy ensuring stable angle reporting over full -40°C to +150°C range |
| Magnetic Range | ±4 T absolute max; BX/BY: 20–70 mT typical, BZ: 24–140 mT - supports high-strength neodymium magnets in compact layouts |
| Supply & Current | 4.5–5.5 V nominal; 13.5 mA typical (fast mode, single die), 27 mA total for dual-die operation at 20 MHz clock |
| Accuracy | INL ≤ ±4 %VDD, DNL ≤ ±1 LSB, ratiometry error ±0.1 %VDD - enables direct ADC interfacing without external reference trimming |
| Programmability | 40-bit ID, Alpha/Beta discontinuity points, clamping (0–100% VDD), dead zone, and FIR/IIR filter coefficients stored in EEPROM |
| Isolation | 4 MΩ inter-die resistance - validated for functional safety applications requiring redundant signal paths |
Pinout & Package
TSSOP-16 package with dual-die architecture: VDD1/VSS1/VDIG1 for Die 1; VDD2/VSS2/VDIG2 for Die 2; dedicated SPI lines (/SS1, SCLK1, MOSI1/MISO1 and /SS2, SCLK2, MOSI2/MISO2); independent OUT11/OUT21 and OUT12/OUT22 outputs; test pins isolated per Melexis EMC guidance.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1, 9 | VDIG1 / VDIG2 | Digital supply for respective die - decoupling required per die to maintain noise immunity in dual-output mode |
| 2, 10 | VSS1 / VSS2 | Independent ground returns - mandatory separation prevents cross-talk between redundant signal chains |
| 3, 11 | VDD1 / VDD2 | Analog supply inputs - each powers its own Hall front-end, ADC, and DSP core |
| 4, 12 | Test 01 / Test 02 | Factory test access - must be tied to VSS per datasheet Section 4 for optimal EMC performance |
| 5, 13 | /SS1 / /SS2 | Slave-select for SPI interface - enables independent communication with each die without bus contention |
| 6, 14 | SCLK1 / SCLK2 | Clock input for SPI - synchronous operation allows time-aligned calibration of both dies |
| 7, 15 | MOSI1/MISO1 / MOSI2/MISO2 | Full-duplex serial data - supports concurrent parameter read/write to both EEPROM banks |
| 8, 16 | Test 11 / Test 12 | Secondary test access - grounded per Melexis layout guidelines to suppress parasitic coupling |
Key Features
| Feature | Design Value |
|---|---|
| Dual-die redundancy | Fully independent signal chains in one TSSOP-16 package - meets ASIL-B requirements for fail-operational position feedback |
| Triaxis® 3D sensing | Simultaneous BX, BY, BZ measurement using IMC-enhanced horizontal and conventional vertical Hall plates - eliminates mechanical alignment sensitivity |
| End-of-line programmability | Alpha/Beta transfer curves, clamping, dead zone, and filter coefficients calibrated via PTC-04 through VDD-VSS-OUT pins - no additional programming hardware needed |
| Enhanced joystick correction | Programmable angle formula compensates for magnet tilt and mechanical non-orthogonality - reduces system-level calibration effort by >50% |
| Diagnostic coverage | Built-in broken-VSS/VDD detection, output short-circuit monitoring, and watchdog timeout - reports faults via dedicated diagnostic output levels |
Applications
| Joystick Interface | Rotary Throttle Control |
|---|---|
Use Scenario: 4-way analog joystick in off-road vehicle HMI requiring precise X/Y displacement tracking under vibration and EMI. IC Role / Device Role / Timing Role: MLX90333LGO-BCH-100-SP acts as primary 3D position transducer, delivering independent ratiometric analog outputs for X and Y axes with <600 ms step response in slow mode. Use Value: Dual-die architecture ensures continued operation if one die fails; programmable dead zone eliminates false triggers during idle state. | Use Scenario: Contactless throttle pedal position sensing in commercial diesel engines where dust, oil, and temperature extremes degrade potentiometers. IC Role / Device Role / Timing Role: MLX90333LGO-BCH-100-SP serves as ASIL-B-compliant rotary angle sensor, reporting absolute angular position via PWM output synchronized to engine control unit timing. Use Value: 10-bit thermal accuracy maintains ±0.5° linearity over -40°C to +150°C; IMC gain stability minimizes recalibration frequency. |
| Linear Stroke Sensor | Man-Machine Interface (MMI) |
Use Scenario: Hydraulic cylinder position feedback in agricultural machinery, where stroke length up to 100 mm must be measured without physical contact. IC Role / Device Role / Timing Role: MLX90333LGO-BCH-100-SP functions as linear position transducer using magnet displacement parallel to device surface, outputting analog voltage proportional to stroke. Use Value: Programmable clamping (0–100% VDD) prevents saturation at stroke limits; 12-bit resolution enables 0.025 mm position granularity. | Use Scenario: Touchless scroll key on medical infusion pump UI requiring reliable 4-way navigation in sterilized environments. IC Role / Device Role / Timing Role: MLX90333LGO-BCH-100-SP operates as 4-way directional switch, using discrete OUT1/OUT2 logic states to encode up/down/left/right commands via SPI frame layer. Use Value: 40-bit unique ID enables device-level traceability; programmable diagnostics detect open-circuit magnet misalignment before field failure. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar 3D magnetic position sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MLX90363KGO-ABA-000-SP | Single-die TSSOP-16, identical pinout but no dual-die redundancy; 12-bit resolution, same Triaxis® front-end | Lacks inter-die isolation and fault-tolerant reporting - suitable for non-safety-critical joysticks | Select when cost sensitivity outweighs ASIL-B compliance requirements |
| AMS AS5055A-BQFT | 14-bit resolution, SPI-only interface, no analog/PWM outputs; 3.3 V only, -40°C to +125°C rating | No dual-output capability or programmable transfer curve - limited to single-axis angular reporting | Choose for space-constrained designs needing higher resolution but accepting narrower temp range and reduced interface flexibility |
Compared with MLX90333LGO-BCH-100-SP, MLX90363KGO-ABA-000-SP offers identical functionality at lower cost but lacks redundancy, while AMS AS5055A-BQFT trades dual-output versatility and extended temperature range for higher raw resolution and smaller footprint - making the MLX90333LGO-BCH-100-SP optimal for safety-critical, multi-axis, high-temp industrial motion control.
Availability
MLX90333LGO-BCH-100-SP is available at Aetrix Electronics and suitable for automotive throttle systems, industrial hydraulic position feedback, and medical device man-machine interfaces requiring stable component supply, long-term lifecycle support, and RoHS-compliant packaging.
Supply support for MLX90333LGO-BCH-100-SP includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Melexis is a Belgian semiconductor company specializing in intelligent sensors and driver ICs for automotive, industrial, and consumer applications, with core expertise in magnetic sensing and signal processing.
The MLX90333 product line delivers contactless 3D position sensing for safety-critical human-machine interfaces, emphasizing redundancy, end-of-line programmability, and robustness in harsh thermal and EMI environments.
FAQ
What output interface modes does the MLX90333LGO-BCH-100-SP support?
The MLX90333LGO-BCH-100-SP supports three configurable output modes: ratiometric analog voltage, PWM (100–1000 Hz), and 3-wire SPI serial protocol. In joystick mode, it delivers two independent outputs (OUT1/OUT2), each selectable for analog, PWM, or SPI reporting. All modes are programmable via Melexis PTC-04 using only VDD, VSS, and OUT pins - no dedicated programming interface required. The MLX90333LGO-BCH-100-SP's SPI implementation includes /SS, SCLK, and MOSI/MISO lines per die for dual-channel calibration.
How does the dual-die architecture of the MLX90333LGO-BCH-100-SP improve reliability?
The MLX90333LGO-BCH-100-SP integrates two functionally identical silicon dies in one TSSOP-16 package, each with independent VDD/VSS/VDIG supplies, Hall front-ends, DSP cores, and output stages. With 4 MΩ inter-die isolation, it enables true hardware redundancy: if one die fails due to ESD, thermal stress, or magnetic overload, the second die continues operation with no interruption to position reporting. This architecture satisfies ASIL-B requirements for automotive throttle and industrial safety systems. The MLX90333LGO-BCH-100-SP also supports cross-die diagnostics to flag mismatched outputs before system-level failure.
Can the MLX90333LGO-BCH-100-SP be used for linear position sensing?
Yes, the MLX90333LGO-BCH-100-SP supports linear position sensing via magnet displacement parallel to the device surface - a configuration explicitly validated in Melexis Application Note AN-012. Its Triaxis® architecture measures BZ (vertical field) alongside BX/BY, enabling accurate stroke detection up to 100 mm with 12-bit resolution (0.025 mm granularity at 100 mm range). Programmable clamping (0–100% VDD) prevents output saturation at mechanical limits, and thermal drift compensation maintains ±0.5° angular-equivalent linearity over -40°C to +150°C. The MLX90333LGO-BCH-100-SP's analog output mode delivers direct voltage proportionality to displacement, eliminating need for external signal conditioning.
What is the purpose of the Alpha and Beta parameters in the MLX90333LGO-BCH-100-SP?
Alpha and Beta are independent, user-programmable transfer curve parameters that define the mathematical relationship between magnetic input (BX/BY/BZ) and output signal for each channel. Alpha governs the primary angular output (e.g., joystick X-axis), Beta the secondary (e.g., Y-axis), each supporting 3-point, 4-segment piecewise-linear mapping with configurable discontinuity points, dead zones, initial slopes, and clamping. These parameters are stored in EEPROM and calibrated end-of-line using Melexis PTC-04 - enabling custom linearity correction for magnet geometry, mechanical tolerances, or system-specific nonlinearity. The MLX90333LGO-BCH-100-SP's Alpha/Beta engine allows one device to replace multiple fixed-function sensors across diverse mechanical assemblies.
Does the MLX90333LGO-BCH-100-SP require external components for basic operation?
No, the MLX90333LGO-BCH-100-SP operates with minimal external components: a single 4.7 µF bulk capacitor on VDD and 100 nF ceramic decoupling per VDD/VDIG pin are sufficient for stable analog/PWM output. Its integrated 3.3 V regulator powers internal digital blocks, and the Triaxis® front-end requires no external magneto-concentrators - the IMC is monolithically integrated. For SPI mode, standard pull-up resistors on /SS and SCLK lines are recommended per Melexis layout guidelines. No external op-amps, ADCs, or microcontrollers are needed, as the MLX90333LGO-BCH-100-SP embeds full signal chain processing including 16-bit RISC DSP, 128 B EEPROM, and programmable filter coefficients.
MLX90333LGO-BCH-100-SP Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Melexis Technologies NV
- Series:
- Triaxis®
- Package/Case:
- 16-TSSOP (0.173", 4.40mm Width)
- Packaging:
- Bulk
- Product Status:
- Active
- Technology:
- Hall Effect
- Axis:
- X, Y, Z
- Output Type:
- SPI
- Sensing Range:
- 20mT ~ 70mT (X,Y), 24mT ~ 140mT (Z)
- Voltage - Supply:
- 4.5V ~ 5.5V
- Current - Supply (Max):
- 16mA
- Current - Output (Max):
- 30mA
- Resolution:
- 12 b
- Bandwidth:
- -
- Operating Temperature:
- -40°C ~ 150°C
- Grade:
- -
- Qualification:
- -
- Features:
- Programmable
- Supplier Device Package:
- 16-TSSOP
- Mounting Type:
- Surface Mount
MLX90333LGO-BCH-100-SP FAQ
1.How can I place an order for MLX90333LGO-BCH-100-SP through Aetrix?
Please submit a Request for Quotation (RFQ) for MLX90333LGO-BCH-100-SP on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MLX90333LGO-BCH-100-SP reliable?
The price and inventory of MLX90333LGO-BCH-100-SP are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MLX90333LGO-BCH-100-SP is usually 5 days.
3.What payment methods are accepted for MLX90333LGO-BCH-100-SP?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MLX90333LGO-BCH-100-SP transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MLX90333LGO-BCH-100-SP?
MLX90333LGO-BCH-100-SP orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MLX90333LGO-BCH-100-SP order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MLX90333LGO-BCH-100-SP?
For technical support, including MLX90333LGO-BCH-100-SP datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MLX90333LGO-BCH-100-SP requirements.
6.How does Aetrix verify that MLX90333LGO-BCH-100-SP is sourced from the original manufacturer or authorized distributors?
All MLX90333LGO-BCH-100-SP products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MLX90333LGO-BCH-100-SP meets industry standards.
7.What is the process for return or replacement of MLX90333LGO-BCH-100-SP?
All MLX90333LGO-BCH-100-SP units undergo pre-shipment inspection (PSI). If there is an issue with MLX90333LGO-BCH-100-SP, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MLX90333LGO-BCH-100-SP part is unused and in its original packaging.
Return procedure for MLX90333LGO-BCH-100-SP:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MLX90333LGO-BCH-100-SP Tags
-
DRV5053VAQDBZR
Texas Instruments

-
MMC5603NJ
Memsic Inc.

-
DRV5055A1QDBZR
Texas Instruments

-
MLX90392ELQ-AAA-011-RE
Melexis Technologies NV

-
CT100LW-HS6
Allegro MicroSystems

-
DRV5056A1ELPGMQ1
Texas Instruments

-
A1304ELHLX-T
Allegro MicroSystems

-
MMC5633NJL
Memsic Inc.

-
A1308KUA-2-T
Allegro MicroSystems

-
A1308KUA-1-T
Allegro MicroSystems

-
SI7210-B-04-IVR
Silicon Labs

-
A1308LLHLT-2-T
Allegro MicroSystems
Tech Hub
Comparator circuit design covering voltage thresholds, input limits, open-collector outputs, LM393 wiring, op-amp differences, hysteresis, timing, window detection and practical fault diagnosis.
Schmitt triggers use separate rising and falling thresholds to stabilize slow or noisy signals. This guide covers hysteresis, 74HC14 and 74HCT14 selection, comparator calculations, RC oscillators and p…
Counterfeit components can hide behind convincing markings and passing basic function tests. This engineering reference covers source traceability, external inspection, X-ray, XRF, electrical testing, …
A practical engineering and sourcing framework covering lifecycle verification, lifetime-buy calculations, replacement qualification, supplier checks and counterfeit-risk controls.
TTL and CMOS logic families differ in thresholds, loading, output drive, power and timing. This engineering guide compares 74HC and 74HCT, calculates noise margins and checks 3.3 V/5 V compatibility.
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …