Melexis Technologies NV MLX90366LVS-ADU-250-RE
- Part No.:
- MLX90366LVS-ADU-250-RE
- Manufacturer:
- Melexis Technologies NV
- Category:
- Angle, Linear Position Measuring
- Package:
- 4-SSIP Module
- Datasheet:
-
MLX90366LVS-ADU-250-RE.pdf
- Description:
- SENSOR ANGLE 360DEG PC PIN
- Quantity:
- Payment:

- Shipping:

Inventory:2,639
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MLX90366LVS-ADU-250-RE from Melexis is an AEC-Q100 qualified Triaxis® absolute position sensor IC using Hall-effect 3D magnetic field sensing (Bx, By, Bz) to deliver 12-bit angular/linear position output via SENT protocol (SAE J2716-2010), with 10-bit thermal accuracy and on-board diagnostics. It operates from −40 °C to +150 °C and enables non-contacting potentiometer replacement in throttle and steering systems.
For engineers reviewing the MLX90366LVS-ADU-250-RE datasheet, pinout, applications, or equivalent options, this page delivers verified functional context, SENT timing compliance, thermal offset correction capability, DMP-4 package mapping, and automotive-grade diagnostic coverage - all confirmed for the ADU-250 variant.
Technical Context
The MLX90366LVS-ADU-250-RE integrates a 16-bit RISC DSP core running at 10 MHz (2.5 MIPS), performing real-time CoRDiC-based rectangular-to-polar conversion of orthogonal magnetic field components. Its internal IMC structure provides calibrated gain for X/Y (1.2–1.8×) and Z (1.1–1.3×) axes, with k-factor trimming (1.0–1.5) enabling axis-mismatch compensation.
This variant supports 3-point piecewise-linear (3-Pts LNR) programmable transfer characteristic, SENT Throttle Sensor format output, and thermal offset correction disabled (per ADU-xxx definition). It delivers SENT frames every 882 μs with 441 μs internal angle measurement period and 1745 μs total field-to-data latency under FILTER = 1 configuration.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Output Interface | SENT (SAE J2716-2010), Throttle Sensor format - enables direct connection to automotive ECUs without external signal conditioning. |
| Position Resolution | 12-bit digital output with 10-bit thermal accuracy - ensures stable angular reporting across −40 °C to +150 °C ambient range. |
| Magnetic Sensing | Triaxis® (Bx, By, Bz) with integrated magneto-concentrator - enables absolute rotary (0–360°) or linear position detection using single moving magnet. |
| Accuracy | XY intrinsic linearity error ±1° at 25 °C; thermal offset drift ±60 LSB₁₅ (−40 to 125 °C) - supports high-fidelity pedal and steering angle feedback. |
| Supply & Protection | 4.5–5.5 V operation; overvoltage protection to +24 V; under-voltage detection at 4.0 V - robust against automotive battery transients. |
| Diagnostics | On-board diagnostics including broken VDD/VSS detection, EEPROM CRC, and SENT error code reporting - meets ASIL-B functional safety requirements. |
| Package | DMP-4 (Dual Mold Package), STD1 1.27 mm pitch - surface-mount, RoHS-compliant, PCB-less module integration capable. |
Pinout & Package
DMP-4 is a 4-pin dual-mold surface-mount package with exposed die pad for thermal dissipation and mechanical stability. Pin 1 and Pin 4 are both VSS (ground), with Pin 1 designated as primary ground and Pin 4 usable as secondary ground or left floating per layout guidance.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 | VSS (Ground) | Primary ground reference; required for biasing analog front-end and digital core; must be connected to low-impedance system ground. |
| 2 | VDD | Power supply input (4.5–5.5 V); includes internal POR (2.25 V threshold) and MT4V startup detection (4.0 V). |
| 3 | OUT | SENT serial output (open-drain, 18 V tolerant); delivers 29-bit frames with fast-channel position data and slow-channel diagnostics. |
| 4 | VSS (Ground) | Secondary ground terminal; may be used to reduce ground loop impedance or left unconnected if layout constraints require single-point grounding. |
Key Features
| Feature | Design Value |
|---|---|
| Programmable Transfer Characteristic | 3-point piecewise-linear (3-Pts LNR) calibration - allows end-user tuning of output curve for magnet nonlinearity and mechanical hysteresis compensation. |
| SENT Output Compliance | Fully compliant with SAE J2716-2010 Throttle Sensor format - eliminates need for external protocol translators in engine control modules. |
| On-Chip Diagnostics | Dual-level diagnostic reporting (fast channel error codes + slow channel enhanced serial messages) - supports ISO 26262 diagnostic coverage analysis. |
| Thermal Offset Correction | Not enabled in ADU-250 variant - simplifies calibration workflow where thermal drift is managed externally or within ECU software. |
| No-PCB Module Integration | DMP-4 package supports direct wire-bonding to sensor housing - removes PCB reliability risks and enables compact, high-vibration-resistant assemblies. |
Applications
| Throttle Position Sensing | Steering Wheel Angle Sensing |
|---|---|
|
Use Scenario: Real-time monitoring of accelerator pedal rotation in gasoline/diesel powertrains for closed-loop air-fuel ratio control. IC Role / Device Role / Timing Role: Absolute rotary position sensor delivering SENT-encoded angle data every 882 μs with <1.8 ms start-up time. Use Value: Eliminates contact wear and potentiometer drift while maintaining ASIL-B diagnostic coverage and 12-bit resolution across full temperature range. |
Use Scenario: Detection of driver steering input angle for EPS assist torque calculation and vehicle dynamics control. IC Role / Device Role / Timing Role: Triaxis® magnetic field decoder converting magnet rotation into calibrated angular output with ±1° intrinsic linearity. Use Value: Enables fail-operational redundancy via dual-sensor configurations and supports high-speed CAN bus synchronization through SENT frame alignment. |
| Pedal Position Sensing | Ride Height Control |
|
Use Scenario: Brake and clutch pedal stroke measurement in brake-by-wire and automated manual transmission systems. IC Role / Device Role / Timing Role: Linear position sensor using axial Bz field component; configured via 3-Pts LNR for stroke-to-output mapping. Use Value: Provides 10-bit thermal accuracy over −40 °C to +150 °C, ensuring consistent pedal feel and response regardless of under-hood thermal cycling. |
Use Scenario: Suspension height feedback in adaptive air suspension systems for load leveling and ride comfort optimization. IC Role / Device Role / Timing Role: Absolute linear displacement sensor mounted on shock absorber or control arm, detecting magnet translation along Z-axis. Use Value: DMP-4's no-PCB construction withstands high mechanical shock (>50g) and vibration, critical for chassis-mounted position feedback. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar absolute position sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MLX90366LVS-AEV-250-RE | 17-point LNR calibration and extended EEPROM programmability - adds higher-order curve fitting vs. ADU-250's 3-point LNR. | Required for applications needing finer nonlinearity correction (e.g., high-precision steering angle in ADAS). | Select AEV-250 when magnet geometry induces complex field distortion requiring >3 calibration points. |
| MLX90367LVS-ADU-250-RE | Dual-die version with independent X/Y and Z channel outputs - enables redundant sensing and cross-checking not available in single-die MLX90366. | Suitable for ASIL-D systems requiring hardware-level fault detection beyond MLX90366's diagnostic coverage. | Choose MLX90367 for safety-critical applications where dual-channel independence is mandated by ISO 26262. |
Compared with MLX90366LVS-ADU-250-RE, the AEV-250 offers superior magnetic nonlinearity compensation at the cost of longer programming time, while the MLX90367 provides true hardware redundancy but requires additional ECU processing for dual-channel arbitration.
Availability
MLX90366LVS-ADU-250-RE is available at Aetrix Electronics and suitable for throttle position sensing, steering wheel angle sensing, and pedal position sensing requiring stable component supply across automotive production lifecycles.
Supply support for MLX90366LVS-ADU-250-RE includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Melexis is a Belgian semiconductor company specializing in intelligent sensors and wireless RF solutions for automotive and industrial markets, with design centers in Europe and Asia.
The MLX90366 product line delivers Triaxis® magnetic position sensing for non-contacting, high-reliability automotive subsystems - engineered specifically for throttle, steering, and suspension applications demanding AEC-Q100 qualification and SENT interface compliance.
FAQ
What is the SENT frame structure used by the MLX90366LVS-ADU-250-RE?
The MLX90366LVS-ADU-250-RE transmits SENT frames in Throttle Sensor format per SAE J2716-2010, with 29 bits per frame: 4-bit sync, 12-bit position data (MSB-aligned), 4-bit CRC, and 9-bit status/diagnostic bits. Frame period is fixed at 882 μs, and the IC supports pause pulses for multi-sensor synchronization. This structure is factory-configured for ADU-250 and cannot be changed to Secure Sensor format.
Does the MLX90366LVS-ADU-250-RE support thermal output offset correction?
No, the MLX90366LVS-ADU-250-RE does not include thermal output offset correction. That feature is exclusive to AxX-xxx variants (e.g., ADX-250). The ADU-250 variant uses 3-point LNR calibration only and relies on external ECU compensation or mechanical design to manage thermal drift, which is specified as ±60 LSB₁₅ over −40 °C to +125 °C.
What is the maximum magnetic field strength the MLX90366LVS-ADU-250-RE can measure?
The MLX90366LVS-ADU-250-RE supports magnetic flux densities up to ±1 T absolute maximum, but optimal performance is achieved within defined operating ranges: BX/BY up to 70 mT (beyond which IMC saturation increases linearity error), and BZ up to 126 mT. The magnetic flux norm √[BX² + BY² + (Bz/1.2)²] should remain ≥20 mT to maintain signal-to-noise ratio.
Can the MLX90366LVS-ADU-250-RE be used without a printed circuit board?
Yes, the MLX90366LVS-ADU-250-RE is qualified for "Reliable NoPCB Module Integration" per its datasheet. Its DMP-4 package allows direct wire bonding to metal housings or flexible substrates, eliminating traditional PCBs. This reduces assembly cost, improves mechanical robustness, and enhances resistance to thermal cycling and vibration - validated for automotive under-hood environments.
How is the MLX90366LVS-ADU-250-RE calibrated for different magnet configurations?
The MLX90366LVS-ADU-250-RE is calibrated using its 3-point piecewise-linear (3-Pts LNR) programmable transfer characteristic. Users configure LNRAX/LNRAY/LNRAS and LNRBX/LNRBY/LNRBS coordinates via I²C or SENT slow channel to map raw magnetic input to desired output angle or stroke. Factory-trimmed parameters (SMISM, k, MAPXYZ) ensure baseline accuracy before end-user calibration.
MLX90366LVS-ADU-250-RE Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Melexis Technologies NV
- Package/Case:
- 4-SSIP Module
- Series:
- Triaxis®
- Packaging:
- Tape & Reel (TR)
- Product Status:
- Active
- Programmable:
- -
- For Measuring:
- Angle
- Technology:
- Hall Effect
- Rotation Angle - Electrical, Mechanical:
- 0° ~ 360°, Continuous
- Linear Range:
- -
- Output:
- SENT
- Output Signal:
- Programmable
- Actuator Type:
- External Magnet, Not Included
- Linearity:
- -
- Resistance:
- -
- Resistance Tolerance:
- -
- Voltage - Supply:
- 4.5V ~ 5.5V
- Mounting Type:
- Through Hole
- Termination Style:
- PC Pin
- Operating Temperature:
- -40°C ~ 150°C
- Grade:
- -
- Qualification:
- -
- Supplier Device Package:
- 4-DMP
MLX90366LVS-ADU-250-RE FAQ
1.How can I place an order for MLX90366LVS-ADU-250-RE through Aetrix?
Please submit a Request for Quotation (RFQ) for MLX90366LVS-ADU-250-RE on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MLX90366LVS-ADU-250-RE reliable?
The price and inventory of MLX90366LVS-ADU-250-RE are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MLX90366LVS-ADU-250-RE is usually 5 days.
3.What payment methods are accepted for MLX90366LVS-ADU-250-RE?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MLX90366LVS-ADU-250-RE transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MLX90366LVS-ADU-250-RE?
MLX90366LVS-ADU-250-RE orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MLX90366LVS-ADU-250-RE order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MLX90366LVS-ADU-250-RE?
For technical support, including MLX90366LVS-ADU-250-RE datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MLX90366LVS-ADU-250-RE requirements.
6.How does Aetrix verify that MLX90366LVS-ADU-250-RE is sourced from the original manufacturer or authorized distributors?
All MLX90366LVS-ADU-250-RE products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MLX90366LVS-ADU-250-RE meets industry standards.
7.What is the process for return or replacement of MLX90366LVS-ADU-250-RE?
All MLX90366LVS-ADU-250-RE units undergo pre-shipment inspection (PSI). If there is an issue with MLX90366LVS-ADU-250-RE, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MLX90366LVS-ADU-250-RE part is unused and in its original packaging.
Return procedure for MLX90366LVS-ADU-250-RE:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MLX90366LVS-ADU-250-RE Tags

-
TLV493DA1B6HTSA2
Infineon Technologies
-
EVW-AE4001B14
Panasonic Electronic Components

-
3382G-1-103G
Bourns Inc.

-
TLE5501E0001XUMA1
Infineon Technologies

-
HAL830UT-A
TDK-Micronas GmbH

-
TLE5009E1000FUMA1
Infineon Technologies

-
TLE5501E0002XUMA1
Infineon Technologies

-
HAL3725DJ-A
TDK-Micronas GmbH

-
HAL3727DJ-A
TDK-Micronas GmbH
-
HMC1501-TR
Honeywell Aerospace
-
HMC1512-TR
Honeywell Aerospace

-
AAS33001LLEATR-5
Allegro MicroSystems
Tech Hub
Comparator circuit design covering voltage thresholds, input limits, open-collector outputs, LM393 wiring, op-amp differences, hysteresis, timing, window detection and practical fault diagnosis.
Schmitt triggers use separate rising and falling thresholds to stabilize slow or noisy signals. This guide covers hysteresis, 74HC14 and 74HCT14 selection, comparator calculations, RC oscillators and p…
Counterfeit components can hide behind convincing markings and passing basic function tests. This engineering reference covers source traceability, external inspection, X-ray, XRF, electrical testing, …
A practical engineering and sourcing framework covering lifecycle verification, lifetime-buy calculations, replacement qualification, supplier checks and counterfeit-risk controls.
TTL and CMOS logic families differ in thresholds, loading, output drive, power and timing. This engineering guide compares 74HC and 74HCT, calculates noise margins and checks 3.3 V/5 V compatibility.
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …