Melexis Technologies NV MLX90366LVS-ADU-251-SP
- Part No.:
- MLX90366LVS-ADU-251-SP
- Manufacturer:
- Melexis Technologies NV
- Category:
- Angle, Linear Position Measuring
- Package:
- 4-SIP Module, Formed Leads
- Datasheet:
-
MLX90366LVS-ADU-251-SP.pdf
- Description:
- SENSOR ANGLE 360DEG PC PIN
- Quantity:
- Payment:

- Shipping:

Inventory:3,239
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MLX90366LVS-ADU-251-SP from Melexis is an AEC-Q100 qualified Triaxis® absolute position sensor IC using Hall-effect technology to measure Bx, By, and Bz magnetic field components. It delivers 12-bit resolution with 10-bit thermal accuracy, SENT output per SAE J2716-2010 (Throttle format), and operates across −40 °C to +150 °C for automotive pedal and steering wheel position sensing.
For engineers reviewing the MLX90366LVS-ADU-251-SP datasheet, pinout, applications, or equivalent options, this page provides verified technical context, SENT timing compliance, thermal offset correction capability, programmable multi-point transfer characteristic, and DMP-4 package integration details essential for non-contacting rotary/linear sensor design.
Technical Context
The MLX90366LVS-ADU-251-SP implements a 16-bit RISC DSP core running at 10 MHz (2.5 MIPS) to compute absolute angular or linear position from raw sine/cosine ADC outputs (15-bit resolution). Its Triaxis® architecture enables orthogonal and parallel flux density sensing via integrated magneto-concentrators (IMC), supporting both XY-plane rotation (0–360°) and Z-axis linear displacement.
It uses SENT protocol with configurable fast-channel diagnostics and slow-channel enhanced serial messages, supports on-board EEPROM programming of clamping limits, discontinuity point, clock-wise direction, and 17-point piecewise-linear transfer characteristic (per ADU option code), and includes built-in over-voltage protection, under-voltage detection, and passive/active diagnostic reporting.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Output Interface | SENT compliant with SAE J2716-2010 Throttle format - enables direct connection to automotive ECUs without external signal conditioning |
| Resolution & Accuracy | 12-bit output resolution with 10-bit thermal accuracy - ensures stable angular readings ±0.3° over −40 °C to +150 °C in rotary applications |
| Operating Temperature | −40 °C to +150 °C - meets automotive under-hood and transmission-mount requirements |
| Magnetic Sensing | Triaxis® (Bx, By, Bz) with IMC gain of 1.2–1.8 (XY) and 1.1–1.3 (Z) - enables robust position decoding from moving magnets in compact mechanical layouts |
| Supply Voltage | 4.5 V to 5.5 V nominal - compatible with standard 5 V automotive power rails and tolerant up to +24 V transient overvoltage |
| Diagnostic Coverage | On-board diagnostics including broken VDD/VSS detection, short-circuit monitoring, and SENT error-code reporting - reduces need for external fault monitoring circuitry |
| EEPROM Capacity | 128 B user-programmable memory - stores calibration parameters, ID, and transfer function coefficients for end-of-line configuration |
Pinout & Package
DMP-4 (Dual Mold Package) with 4-pin leadframe, STD1 2.54 mm trim-and-form variant (per ADU-251 suffix), RoHS-compliant, no PCB required for module integration.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 | VSS (Ground) | Primary ground reference; floating if Pin 4 used - allows flexible PCB grounding strategy |
| 2 | VDD | 5 V supply input with overvoltage protection to +24 V - withstands load-dump transients in automotive systems |
| 3 | OUT | SENT output (open-drain, push-pull configurable) - delivers calibrated position data and diagnostics in standardized nibble format |
| 4 | VSS (Ground) | Secondary ground terminal - improves noise immunity and current return path redundancy |
Key Features
| Feature | Design Value |
|---|---|
| Programmable Transfer Characteristic | 17-point piecewise-linear (PWL) calibration stored in EEPROM - enables precise nonlinearity correction for custom magnetic circuits |
| Thermal Output Offset Correction | Enabled in ADU-xxx variants - compensates for temperature-induced zero-point drift without external compensation circuitry |
| No-PCB Module Integration | DMP-4 package with integrated IMC and bond wires - eliminates PCB assembly step and improves mechanical robustness in harsh environments |
| AEC-Q100 Qualified | Grade 0 qualification (−40 °C to +150 °C) - validated for safety-critical automotive applications including throttle and steering position sensing |
| SENT Diagnostic Reporting | Fast-channel error codes and slow-channel OEM-defined serial messages - supports ASAM MCD-2 MC diagnostics and ECU-level fault classification |
Applications
| Pedal Position Sensing | Steering Wheel Angle Sensing |
|---|---|
Use Scenario: Detect accelerator or brake pedal angle in electric/hybrid powertrain control units. IC Role / Device Role / Timing Role: Absolute rotary position sensor delivering SENT frames every 882 μs with <1.75 ms total latency from field change to output. Use Value: Enables closed-loop torque control with <±0.3° angular accuracy over full temperature range and lifetime. | Use Scenario: Monitor steering column rotation for EPS assist and ADAS lane-keeping functions. IC Role / Device Role / Timing Role: Triaxis® magnetic decoder computing real-time angle from rotating magnet mounted on shaft. Use Value: Provides fail-safe position data with on-board diagnostics (broken VDD/VSS detection) meeting ISO 26262 ASIL-B requirements. |
| Throttle Valve Position | Float-Level Sensing |
Use Scenario: Measure butterfly valve rotation in engine management systems. IC Role / Device Role / Timing Role: SENT-output absolute position sensor with programmable clamping limits and discontinuity point setting. Use Value: Eliminates potentiometer wear-out; supports end-of-line calibration via EEPROM to match mechanical travel range. | Use Scenario: Determine fuel or coolant level via linear displacement of float-mounted magnet. IC Role / Device Role / Timing Role: Linear position sensor using Bz component detection with thermal offset correction. Use Value: Delivers stable 12-bit output over temperature without external compensation, reducing system BOM cost. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar absolute position sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MLX90366LVS-AEV-251-SP | Same DMP-4 package and SENT interface; uses 17-pt PWL but lacks thermal offset correction | Suitable where ambient temperature stability is high and thermal drift compensation is handled externally | Select when lower-cost calibration suffices and thermal offset drift <±0.3° is acceptable |
| MLX90366LVS-AEU-251-SP | Includes thermal offset correction and 17-pt PWL; differs only in EEPROM lock configuration (lock enabled vs. disabled in ADU) | Preferred for production modules requiring write-protection of calibrated parameters post-configuration | Select when firmware-controlled reprogramming must be prevented after final calibration |
Compared with MLX90366LVS-AEV-251-SP and MLX90366LVS-AEU-251-SP, the MLX90366LVS-ADU-251-SP provides identical thermal offset correction and 17-point calibration but retains full EEPROM programmability - making it optimal for development, prototyping, and applications requiring field-updatable transfer characteristics.
Availability
MLX90366LVS-ADU-251-SP is available at Aetrix Electronics and suitable for automotive pedal position sensing, steering angle measurement, and throttle valve monitoring requiring stable component supply across extended temperature ranges and long product lifecycles.
Supply support for MLX90366LVS-ADU-251-SP includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Melexis is a Belgian semiconductor company specializing in intelligent sensors and driver ICs for automotive and industrial markets, with expertise in magnetic sensing, infrared thermometry, and automotive ASICs.
The MLX90366 product line delivers Triaxis® position sensing for non-contacting, high-reliability applications in powertrain, chassis, and body electronics - designed specifically to replace legacy potentiometers and resolver-based systems.
FAQ
What is the SENT frame period and latency specification for MLX90366LVS-ADU-251-SP?
The MLX90366LVS-ADU-251-SP delivers SENT frames every 882 μs. Field change to SENT data latency is 1745 μs with FILTER = 1 (recommended setting). First sync pulse appears within 1.8 ms of power-on, and first valid data is received within 6.3 ms. These values are measured per SAE J2716-2010 and confirmed in the official datasheet revision 002.
Does MLX90366LVS-ADU-251-SP support thermal output offset correction?
Yes, MLX90366LVS-ADU-251-SP supports thermal output offset correction as specified in section 14.1.6 of the datasheet. This feature is enabled in ADU-xxx option codes and corrects zero-point drift over temperature - critical for maintaining <±0.3° accuracy in rotary applications across −40 °C to +150 °C.
What package type and pin configuration does MLX90366LVS-ADU-251-SP use?
MLX90366LVS-ADU-251-SP uses the DMP-4 (Dual Mold Package) with 4 terminals in STD1 2.54 mm trim-and-form configuration. Pinout is VSS–VDD–OUT–VSS, with either VSS pin usable for grounding. The package is RoHS-compliant and designed for no-PCB module integration per section 19.2 of the datasheet.
How many programmable points does the transfer characteristic support in MLX90366LVS-ADU-251-SP?
The MLX90366LVS-ADU-251-SP supports a 17-point piecewise-linear (PWL) transfer characteristic, as defined for ADU-xxx option codes in section 14.1.4 of the datasheet. This enables high-fidelity calibration across full mechanical stroke or rotation range, improving INL performance beyond factory-trimmed levels.
Is MLX90366LVS-ADU-251-SP AEC-Q100 qualified and for which grade?
Yes, MLX90366LVS-ADU-251-SP is AEC-Q100 qualified for Grade 0 (−40 °C to +150 °C ambient), as stated in the Features and Benefits section and confirmed in section 5 (Absolute Maximum Ratings). This qualification validates its suitability for safety-critical automotive applications including throttle, pedal, and steering position sensing.
MLX90366LVS-ADU-251-SP Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Melexis Technologies NV
- Package/Case:
- 4-SIP Module, Formed Leads
- Series:
- Triaxis®
- Packaging:
- Bulk
- Product Status:
- Not For New Designs
- Programmable:
- -
- For Measuring:
- Angle
- Technology:
- Hall Effect
- Rotation Angle - Electrical, Mechanical:
- 0° ~ 360°, Continuous
- Linear Range:
- -
- Output:
- SENT
- Output Signal:
- Programmable
- Actuator Type:
- External Magnet, Not Included
- Linearity:
- -
- Resistance:
- -
- Resistance Tolerance:
- -
- Voltage - Supply:
- 4.5V ~ 5.5V
- Mounting Type:
- Through Hole
- Termination Style:
- PC Pin
- Operating Temperature:
- -40°C ~ 150°C
- Grade:
- -
- Qualification:
- -
- Supplier Device Package:
- 4-DMP
MLX90366LVS-ADU-251-SP FAQ
1.How can I place an order for MLX90366LVS-ADU-251-SP through Aetrix?
Please submit a Request for Quotation (RFQ) for MLX90366LVS-ADU-251-SP on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MLX90366LVS-ADU-251-SP reliable?
The price and inventory of MLX90366LVS-ADU-251-SP are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MLX90366LVS-ADU-251-SP is usually 5 days.
3.What payment methods are accepted for MLX90366LVS-ADU-251-SP?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MLX90366LVS-ADU-251-SP transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MLX90366LVS-ADU-251-SP?
MLX90366LVS-ADU-251-SP orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MLX90366LVS-ADU-251-SP order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MLX90366LVS-ADU-251-SP?
For technical support, including MLX90366LVS-ADU-251-SP datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MLX90366LVS-ADU-251-SP requirements.
6.How does Aetrix verify that MLX90366LVS-ADU-251-SP is sourced from the original manufacturer or authorized distributors?
All MLX90366LVS-ADU-251-SP products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MLX90366LVS-ADU-251-SP meets industry standards.
7.What is the process for return or replacement of MLX90366LVS-ADU-251-SP?
All MLX90366LVS-ADU-251-SP units undergo pre-shipment inspection (PSI). If there is an issue with MLX90366LVS-ADU-251-SP, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MLX90366LVS-ADU-251-SP part is unused and in its original packaging.
Return procedure for MLX90366LVS-ADU-251-SP:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MLX90366LVS-ADU-251-SP Tags

-
TLV493DA1B6HTSA2
Infineon Technologies
-
EVW-AE4001B14
Panasonic Electronic Components

-
3382G-1-103G
Bourns Inc.

-
TLE5501E0001XUMA1
Infineon Technologies

-
HAL830UT-A
TDK-Micronas GmbH

-
TLE5009E1000FUMA1
Infineon Technologies

-
TLE5501E0002XUMA1
Infineon Technologies

-
HAL3725DJ-A
TDK-Micronas GmbH

-
HAL3727DJ-A
TDK-Micronas GmbH
-
HMC1501-TR
Honeywell Aerospace
-
HMC1512-TR
Honeywell Aerospace

-
AAS33001LLEATR-5
Allegro MicroSystems
Tech Hub
Comparator circuit design covering voltage thresholds, input limits, open-collector outputs, LM393 wiring, op-amp differences, hysteresis, timing, window detection and practical fault diagnosis.
Schmitt triggers use separate rising and falling thresholds to stabilize slow or noisy signals. This guide covers hysteresis, 74HC14 and 74HCT14 selection, comparator calculations, RC oscillators and p…
Counterfeit components can hide behind convincing markings and passing basic function tests. This engineering reference covers source traceability, external inspection, X-ray, XRF, electrical testing, …
A practical engineering and sourcing framework covering lifecycle verification, lifetime-buy calculations, replacement qualification, supplier checks and counterfeit-risk controls.
TTL and CMOS logic families differ in thresholds, loading, output drive, power and timing. This engineering guide compares 74HC and 74HCT, calculates noise margins and checks 3.3 V/5 V compatibility.
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …

