Melexis Technologies NV MLX90367EGO-ACU-000-SP
- Part No.:
- MLX90367EGO-ACU-000-SP
- Manufacturer:
- Melexis Technologies NV
- Category:
- Angle, Linear Position Measuring
- Package:
- 16-TSSOP (0.173", 4.40mm Width)
- Datasheet:
-
MLX90367EGO-ACU-000-SP.pdf
- Description:
- SENS RTY/LNRANLG/PWM SENT16TSSOP
- Quantity:
- Payment:

- Shipping:

Inventory:4,083
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MLX90367EGO-ACU-000-SP from Melexis is a Triaxis® Hall-effect position sensor IC delivering absolute rotary or linear position measurement via SENT output (SAE J2716-2010). It resolves 3-axis magnetic flux (BX, BY, BZ) with 12-bit resolution and 10-bit thermal accuracy in a TSSOP-16 dual-die package, enabling robust non-contact sensing in automotive throttle and steering wheel position systems.
For engineers reviewing the MLX90367EGO-ACU-000-SP datasheet, pinout, applications, or equivalent options, key selection considerations include SENT protocol compliance, dual-die redundancy, programmable 3-point linear transfer characteristic, thermal offset correction capability, and operation across –40 °C to +150 °C.
Technical Context
The MLX90367EGO-ACU-000-SP integrates on-chip analog signal processing (ASP) and digital signal processing (DSP) to compute absolute angular or linear position from orthogonal and parallel magnetic field components. Its dual-die architecture provides full hardware redundancy for functional safety-critical applications.
It implements SENT output using Throttle Sensor format with fast-channel diagnostics and slow-channel enhanced serial messages. The DSP core is a 16-bit RISC microcontroller running at 10 MHz (2.5 MIPS), supporting end-user programming of transfer characteristics, clamping limits, and diagnostic settings via EEPROM.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Output Interface | SENT (SAE J2716-2010), Throttle Sensor format with fast/slow channels |
| Resolution & Accuracy | 12-bit position resolution; 10-bit thermal accuracy over –40 °C to +150 °C |
| Magnetic Sensing | Triaxis® Hall technology measuring BX, BY, BZ simultaneously for absolute angle/displacement |
| Package | TSSOP-16, RoHS-compliant, dual-die configuration for redundancy |
| Operating Temperature | –40 °C to +150 °C (Temperature Code L) |
| Programmability | User-configurable 3-point linear transfer characteristic (LNR), clamping, diagnostics, and filter settings |
| Supply Voltage | 4.5 V to 5.5 V nominal; ±24 V absolute maximum rating |
Pinout & Package
TSSOP-16 package with dual-die redundancy; pins include dedicated VDD1/VDD2, VSS1/VSS2, OUT1/OUT2, and test terminals for calibration and diagnostics. Unused test pins must be grounded per EMC recommendations.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 | VDIG1 | Digital supply for first die; decoupling required for noise immunity |
| 2 | VSS1 | Ground reference for first die; separate return path improves redundancy integrity |
| 3 | VDD1 | Analog supply for first die; independent regulation supports dual-die isolation |
| 4 | Test 01 | Calibration/test terminal for first die; connect to ground unless used for factory programming |
| 5 | Test 22 | Diagnostics access for first die; unused pins must be grounded per EMC guidelines |
| 6 | OUT2 | SENT output from second die; enables cross-checking for ASIL-B/C system monitoring |
| 7 | Not Used | No internal connection; must be grounded to minimize EMI coupling |
| 8 | Test 12 | Second die test interface; grounding ensures stable bias during operation |
| 9 | VDIG2 | Digital supply for second die; independent rail prevents single-point failure propagation |
| 10 | VSS2 | Ground for second die; physical separation enhances fault containment |
| 11 | VDD2 | Analog supply for second die; isolated from VDD1 to maintain redundancy |
| 12 | Test 02 | First test point for second die; grounding required unless actively used |
| 13 | Test 21 | Second test point for second die; tied to ground for EMC compliance |
| 14 | Not Used1 | Unbonded pad; grounding eliminates parasitic antenna effect |
| 15 | OUT1 | Primary SENT output from first die; delivers position data and diagnostic codes |
| 16 | Test 11 | Main test interface for second die; grounding avoids floating node instability |
Key Features
| Feature | Design Value |
|---|---|
| Triaxis® Hall Technology | Simultaneous measurement of BX, BY, BZ enables true 3D position decoding without mechanical cam or gear constraints |
| Dual-Die Redundancy | Independent VDD/VSS and SENT outputs per die support ISO 26262 ASIL-B/C fault detection and fail-operational design |
| Programmable 3-Point LNR | End-user configurable linearization points (AxU version) correct nonlinearity from magnet and mechanical tolerances |
| SENT Output Compliance | Fully compliant with SAE J2716-2010 Throttle Sensor format, including fast-channel diagnostics and slow-channel OEM data |
| Thermal Offset Correction | Compensates output drift over temperature using on-chip calibration coefficients stored in EEPROM |
| 48-bit Unique ID | Factory-programmed identifier enables traceability, secure firmware binding, and counterfeit prevention in production |
Applications
| Throttle Position Sensing | Steering Wheel Angle Sensing |
|---|---|
Use Scenario: Monitoring accelerator pedal position in gasoline/diesel powertrain control units under high-vibration, wide-temperature conditions. IC Role / Device Role / Timing Role: Absolute rotary position sensor converting magnet rotation into SENT-encoded angle data with <1.75 ms latency. Use Value: Eliminates potentiometer wear and contact bounce; dual-die output enables real-time comparison for fault detection. | Use Scenario: Measuring steering column rotation in electric power steering (EPS) systems requiring ASIL-B compliance. IC Role / Device Role / Timing Role: Primary angle transducer feeding torque overlay and lane-keeping algorithms with SENT frame period of 882 μs. Use Value: Triaxis® sensing rejects stray fields from nearby motors; programmable LNR compensates for housing misalignment. |
| Pedal Position Sensing | Ride Height Control |
Use Scenario: Detecting brake or clutch pedal stroke in commercial vehicle braking systems exposed to dust, moisture, and thermal cycling. IC Role / Device Role / Timing Role: Linear displacement sensor using magnet translation along IMC-enhanced field path; outputs SENT frames every 882 μs. Use Value: Non-contact operation ensures lifetime reliability; dual-die architecture meets FMEDA requirements for safety validation. | Use Scenario: Monitoring suspension travel in adaptive air ride systems where precision and long-term stability are critical. IC Role / Device Role / Timing Role: Absolute linear position sensor with thermal offset correction maintaining <±0.3° angular error up to +150 °C. Use Value: On-chip signal processing reduces external MCU load; SENT output simplifies integration with body control modules. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar absolute position sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MLX90367KGO-ACU-000-RE | Same die, TSSOP-16 package, but rated for –40 °C to +125 °C (K grade) instead of L grade (–40 °C to +150 °C) | Suitable for under-hood applications with lower max ambient temperature; not qualified for engine valve train or turbocharger zones | Select when thermal budget allows margin below 150 °C and cost optimization is prioritized |
| MLX90367EGO-ACV-000-RE | Same package and temperature range, but supports 17-point LNR calibration (vs. 3-point in ACU) and no thermal offset correction | Better linearity correction for high-precision industrial encoders; lacks thermal drift compensation needed in automotive powertrain | Choose for applications demanding ultra-low INL where thermal stability is managed externally |
Compared with MLX90367EGO-ACU-000-SP, the K-grade alternative trades thermal range for cost, while the ACV variant offers higher linearization granularity at the expense of thermal drift mitigation-making MLX90367EGO-ACU-000-SP optimal for safety-critical automotive positions where both extended temperature operation and thermal stability are mandatory.
Availability
MLX90367EGO-ACU-000-SP is available at Aetrix Electronics and suitable for automotive throttle position, steering angle, pedal stroke, and ride height sensing applications requiring stable component supply, long-lifecycle support, and ASIL-aligned redundancy.
Supply support for MLX90367EGO-ACU-000-SP includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Melexis is a Belgian semiconductor company specializing in intelligent sensors and driver ICs for automotive and industrial markets, with expertise in magnetic sensing, infrared, and ultrasonic technologies.
The MLX90367 product line delivers Triaxis® Hall-based absolute position sensing for functional safety applications, designed specifically to replace contact-based potentiometers and resolver systems in harsh-environment automotive subsystems.
FAQ
What is the operating temperature range of the MLX90367EGO-ACU-000-SP?
The MLX90367EGO-ACU-000-SP operates from –40 °C to +150 °C, certified to the L temperature grade per Melexis ordering nomenclature. This range is validated across all electrical, magnetic, and timing specifications in the official datasheet revision 7.0, making it suitable for engine bay and transmission-mounted position sensing where extreme thermal cycling occurs. The MLX90367EGO-ACU-000-SP maintains 10-bit thermal accuracy within this full span.
Does the MLX90367EGO-ACU-000-SP support SENT protocol compliance with SAE J2716-2010?
Yes, the MLX90367EGO-ACU-000-SP implements SENT output fully compliant with SAE J2716-2010, using the Throttle Sensor format with fast-channel diagnostics and slow-channel enhanced serial messages. Frame period is fixed at 882 μs, and it supports error code reporting, OEM-defined values, and configurable pause pulses. The MLX90367EGO-ACU-000-SP delivers SENT frames from both OUT1 and OUT2 outputs in dual-die mode.
What type of magnetic field configuration does the MLX90367EGO-ACU-000-SP require?
The MLX90367EGO-ACU-000-SP requires a rotating or translating magnet positioned to generate orthogonal (BX, BY) and parallel (BZ) flux components relative to the IC surface. It uses an Integrated Magneto-Concentrator (IMC®) to enhance sensitivity; typical configurations include off-axis rotary magnets or linear sliders with IMC-backed magnets. The MLX90367EGO-ACU-000-SP achieves optimal accuracy when magnetic flux norm remains ≥20 mT and BX/BY ≥70 mT.
How is redundancy implemented in the MLX90367EGO-ACU-000-SP?
Redundancy in the MLX90367EGO-ACU-000-SP is achieved via physically separate dual dice in one TSSOP-16 package, each with independent VDD1/VDD2, VSS1/VSS2, and SENT outputs (OUT1 and OUT2). Isolation resistance between dice exceeds 4 MΩ. The MLX90367EGO-ACU-000-SP supports cross-die comparison for fault detection and meets requirements for ASIL-B/C system architectures without external duplication.
Can the MLX90367EGO-ACU-000-SP be programmed for custom transfer characteristics?
Yes, the MLX90367EGO-ACU-000-SP supports end-user programming of a 3-point linear transfer characteristic (LNR) via EEPROM, allowing calibration of gain, offset, and breakpoints to compensate for mechanical and magnetic tolerances. Parameters like LNRAX, LNRAY, and LNRS0 are user-writable; the MLX90367EGO-ACU-000-SP retains settings after power cycle and supports lock/unlock via MEMLOCK bits to prevent accidental overwrite.
MLX90367EGO-ACU-000-SP Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Melexis Technologies NV
- Package/Case:
- 16-TSSOP (0.173", 4.40mm Width)
- Series:
- Triaxis®
- Packaging:
- Tube
- Product Status:
- Active
- Programmable:
- -
- For Measuring:
- Linear, Rotary Position
- Technology:
- Hall Effect
- Rotation Angle - Electrical, Mechanical:
- 0° ~ 360°, Continuous
- Linear Range:
- -
- Output:
- SENT
- Output Signal:
- Programmable
- Actuator Type:
- External Magnet, Not Included
- Linearity:
- ±1°
- Resistance:
- -
- Resistance Tolerance:
- -
- Voltage - Supply:
- 4.5V ~ 5.5V
- Mounting Type:
- Surface Mount
- Termination Style:
- Gull Wing
- Operating Temperature:
- -40°C ~ 85°C
- Grade:
- -
- Qualification:
- -
- Supplier Device Package:
- 16-TSSOP
MLX90367EGO-ACU-000-SP FAQ
1.How can I place an order for MLX90367EGO-ACU-000-SP through Aetrix?
Please submit a Request for Quotation (RFQ) for MLX90367EGO-ACU-000-SP on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MLX90367EGO-ACU-000-SP reliable?
The price and inventory of MLX90367EGO-ACU-000-SP are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MLX90367EGO-ACU-000-SP is usually 5 days.
3.What payment methods are accepted for MLX90367EGO-ACU-000-SP?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MLX90367EGO-ACU-000-SP transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MLX90367EGO-ACU-000-SP?
MLX90367EGO-ACU-000-SP orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MLX90367EGO-ACU-000-SP order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MLX90367EGO-ACU-000-SP?
For technical support, including MLX90367EGO-ACU-000-SP datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MLX90367EGO-ACU-000-SP requirements.
6.How does Aetrix verify that MLX90367EGO-ACU-000-SP is sourced from the original manufacturer or authorized distributors?
All MLX90367EGO-ACU-000-SP products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MLX90367EGO-ACU-000-SP meets industry standards.
7.What is the process for return or replacement of MLX90367EGO-ACU-000-SP?
All MLX90367EGO-ACU-000-SP units undergo pre-shipment inspection (PSI). If there is an issue with MLX90367EGO-ACU-000-SP, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MLX90367EGO-ACU-000-SP part is unused and in its original packaging.
Return procedure for MLX90367EGO-ACU-000-SP:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MLX90367EGO-ACU-000-SP Tags

-
TLV493DA1B6HTSA2
Infineon Technologies
-
EVW-AE4001B14
Panasonic Electronic Components

-
3382G-1-103G
Bourns Inc.

-
TLE5501E0001XUMA1
Infineon Technologies

-
HAL830UT-A
TDK-Micronas GmbH

-
TLE5009E1000FUMA1
Infineon Technologies

-
TLE5501E0002XUMA1
Infineon Technologies

-
HAL3725DJ-A
TDK-Micronas GmbH

-
HAL3727DJ-A
TDK-Micronas GmbH
-
HMC1501-TR
Honeywell Aerospace
-
HMC1512-TR
Honeywell Aerospace

-
AAS33001LLEATR-5
Allegro MicroSystems
Tech Hub
Comparator circuit design covering voltage thresholds, input limits, open-collector outputs, LM393 wiring, op-amp differences, hysteresis, timing, window detection and practical fault diagnosis.
Schmitt triggers use separate rising and falling thresholds to stabilize slow or noisy signals. This guide covers hysteresis, 74HC14 and 74HCT14 selection, comparator calculations, RC oscillators and p…
Counterfeit components can hide behind convincing markings and passing basic function tests. This engineering reference covers source traceability, external inspection, X-ray, XRF, electrical testing, …
A practical engineering and sourcing framework covering lifecycle verification, lifetime-buy calculations, replacement qualification, supplier checks and counterfeit-risk controls.
TTL and CMOS logic families differ in thresholds, loading, output drive, power and timing. This engineering guide compares 74HC and 74HCT, calculates noise margins and checks 3.3 V/5 V compatibility.
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …