Melexis Technologies NV MLX90367KGO-ACU-000-RE
- Part No.:
- MLX90367KGO-ACU-000-RE
- Manufacturer:
- Melexis Technologies NV
- Category:
- Angle, Linear Position Measuring
- Package:
- 16-TSSOP (0.173", 4.40mm Width)
- Datasheet:
-
MLX90367KGO-ACU-000-RE.pdf
- Description:
- SENS RTY/LNRANLG/PWM SENT16TSSOP
- Quantity:
- Payment:

- Shipping:

Inventory:2,721
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MLX90367KGO-ACU-000-RE from Melexis is a Triaxis® Hall-effect position sensor IC in TSSOP-16 package, delivering 12-bit resolution SENT output per SAE J2716-2010, with programmable 3-point linear transfer characteristic and thermal offset correction. It decodes absolute rotary or linear position from orthogonal and parallel magnetic field components (BX, BY, BZ) for automotive pedal and steering angle sensing.
For engineers reviewing the MLX90367KGO-ACU-000-RE datasheet, pinout, applications, or equivalent options, this page provides verified pin mapping, real-world accuracy specs (±0.3° angular error at 25°C), SENT frame timing (882 μs period), dual-die isolation (4 MΩ), and validated alternatives for throttle and ride height sensing designs.
Technical Context
The MLX90367KGO-ACU-000-RE implements Triaxis® technology to simultaneously measure BX, BY, and BZ field components using integrated magneto-concentrators (IMC), enabling full 360° absolute angle computation via CoRDiC-based DSP. Its on-chip signal processing includes 16-bit RISC CPU (2.5 MIPS), 10 KB ROM, and 128 B EEPROM for end-user calibration.
This variant uses the ACU option code-supporting 3-point LNR programming, SENT Throttle Sensor format, and thermal offset correction-within the -40°C to 125°C operating range (K temperature grade) and TSSOP-16 dual-die redundant architecture for functional safety compliance.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Output Interface | SENT per SAE J2716-2010, Throttle Sensor format with diagnostic fast channel and enhanced serial slow channel |
| Resolution & Accuracy | 12-bit resolution; ±0.3° typical magnetic angle phase error (XY axis, 25°C); 10-bit thermal accuracy |
| Operating Range | -40°C to +125°C (K-grade); supply voltage 4.5–5.5 V; magnetic flux norm ≥20 mT for optimal SNR |
| Timing Performance | SENT frame period = 882 μs; internal angle measurement period = 441 μs; start-up time to first data = 6.3 ms |
| Package & Redundancy | TSSOP-16 dual-die configuration with 4 MΩ inter-die isolation; RoHS-compliant |
| Programmability | User-configurable 3-point linear transfer curve (LNR), clamping thresholds, diagnostics, and 48-bit ID |
Pinout & Package
TSSOP-16 package with dual-die redundancy for ASIL-B/C functional safety applications; exposed pad recommended for thermal management and EMC grounding.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 | VDIG1 | Digital supply for Die 1 (4.5–5.5 V) |
| 2 | VSS1 | Digital ground for Die 1; must be connected to system ground |
| 3 | VDD1 | Analog supply for Die 1 (4.5–5.5 V) |
| 4 | Test 01 | Factory test pin; connect to ground for optimal EMC |
| 5 | Test 22 | Factory test pin; connect to ground for optimal EMC |
| 6 | OUT2 | SENT output from Die 2 (redundant channel) |
| 7 | Not Used | No internal connection; tie to ground per EMC recommendation |
| 8 | Test 12 | Factory test pin; connect to ground for optimal EMC |
| 9 | VDIG2 | Digital supply for Die 2 (4.5–5.5 V) |
| 10 | VSS2 | Digital ground for Die 2; separate return path enhances fault detection |
| 11 | VDD2 | Analog supply for Die 2 (4.5–5.5 V) |
| 12 | Test 02 | Factory test pin; connect to ground for optimal EMC |
| 13 | Test 21 | Factory test pin; connect to ground for optimal EMC |
| 14 | Not Used1 | No internal connection; tie to ground per EMC recommendation |
| 15 | OUT1 | SENT output from Die 1 (primary channel) |
| 16 | Test 11 | Factory test pin; connect to ground for optimal EMC |
Key Features
| Feature | Design Value |
|---|---|
| Triaxis® 3D Field Sensing | Simultaneous BX/BY/BZ measurement enables true 360° absolute angle without mechanical stops or multi-sensor assemblies |
| SENT Output Compliance | Fully compliant with SAE J2716-2010 Throttle Sensor format, including diagnostic fast channel and configurable slow message sequence |
| Programmable Transfer Curve | 3-point linearization (LNR) allows precise calibration to mechanical stroke or rotation profile without external MCU intervention |
| Dual-Die Redundancy | Independent TSSOP-16 die pair with 4 MΩ isolation supports cross-checking for ISO 26262 ASIL-B/C automotive safety requirements |
| Thermal Offset Correction | On-chip compensation reduces angular error drift to ±60 LSB15 over -40°C to +125°C (K-grade), improving long-term stability in engine bay environments |
Applications
| Pedal Position Sensing | Steering Wheel Angle Sensing |
|---|---|
Use Scenario: Monitoring accelerator/brake pedal displacement in electric and ICE powertrains for torque control and regenerative braking. IC Role / Device Role / Timing Role: Absolute linear position transducer delivering SENT frames every 882 μs with diagnostic reporting for functional safety monitoring. Use Value: Eliminates potentiometer wear-out; achieves ±0.3° angular accuracy at 25°C and maintains <±1° total error across -40°C to +125°C with thermal offset correction. | Use Scenario: Measuring absolute steering wheel rotation angle for EPS assist control, lane-keeping, and ADAS yaw estimation. IC Role / Device Role / Timing Role: Triaxis® magnetic angle decoder providing synchronized dual-channel SENT outputs (OUT1/OUT2) for redundancy validation. Use Value: Dual-die TSSOP-16 architecture enables cross-die comparison with 4 MΩ isolation, supporting ASIL-C fault detection latency under 12 ms. |
| Throttle Valve Position | Ride Height Control |
Use Scenario: Closed-loop feedback of throttle blade angle in gasoline direct injection systems requiring high reliability and EMI immunity. IC Role / Device Role / Timing Role: SENT-output position sensor with programmable 3-point LNR curve matching non-linear throttle cam geometry. Use Value: Factory-trimmable SMISM and k parameters correct sensitivity mismatch and orthogonality errors, reducing intrinsic linearity error to ±1° XY axis at 25°C. | Use Scenario: Detecting suspension travel in adaptive air or coilover systems for vehicle leveling and damping control. IC Role / Device Role / Timing Role: Non-contacting absolute linear position sensor interfacing with chassis controller via SENT protocol. Use Value: Immune to dust, moisture, and vibration; operates reliably at 150°C junction temperature with K-grade thermal specification. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar absolute position sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MLX90367KGO-ACV-000-RE | 17-point LNR programming instead of 3-point; identical package, temperature grade, and SENT interface | Better suited for highly non-linear mechanical paths (e.g., complex linkage geometries) requiring finer transfer curve granularity | Select ACV when mechanical stroke demands >3 calibration points for sub-0.1° residual error after end-of-line tuning |
| MLX90367KGO-ACX-000-RE | Adds thermal output offset correction (enabled by default); same 17-point LNR and dual-die TSSOP-16 package | Required for extended temperature operation where thermal drift dominates error budget (e.g., under-hood transmission position) | Choose ACX when operating continuously above 105°C ambient and angular stability <±0.5° over full range is mandatory |
Compared with MLX90367KGO-ACU-000-RE, the ACV variant offers higher linearization flexibility for complex motion profiles, while the ACX adds active thermal drift compensation-both retain identical pinout, SENT timing, and dual-die safety architecture but require reprogramming of EEPROM calibration tables.
Availability
MLX90367KGO-ACU-000-RE is available at Aetrix Electronics and suitable for automotive pedal position, steering angle, throttle valve, and ride height sensing applications requiring stable component supply, functional safety compliance, and long-term obsolescence management.
Supply support for MLX90367KGO-ACU-000-RE includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Melexis is a Belgian semiconductor company specializing in intelligent sensors and driver ICs for automotive and industrial markets, with core expertise in magnetic sensing, infrared thermometry, and automotive ASIC design.
The MLX90367 product line delivers Triaxis® 3D Hall-effect position sensing for functional safety-critical automotive applications-including EPS, throttle, and brake-by-wire-where absolute angle accuracy, redundancy, and SENT protocol compliance are mandatory.
FAQ
What is the operating temperature range of the MLX90367KGO-ACU-000-RE?
The MLX90367KGO-ACU-000-RE is rated for operation from -40°C to +125°C (K temperature grade). This range is validated across all electrical, magnetic, and timing specifications in the official datasheet Rev 7.0, including SENT frame timing stability, thermal offset drift (±60 LSB15), and magnetic sensitivity mismatch (±0.5% for XY axis). The TSSOP-16 dual-die package supports this extended range through optimized thermal resistance and die isolation.
Does the MLX90367KGO-ACU-000-RE support SENT protocol with diagnostic capabilities?
Yes, the MLX90367KGO-ACU-000-RE implements full SAE J2716-2010 SENT compliance, including Throttle Sensor format with dedicated fast channel for real-time diagnostics (e.g., open-circuit, short-to-battery, broken VSS/VDD reporting) and an enhanced slow channel for user-defined serial messages. Diagnostic levels are specified in the datasheet: BVSSPD = 95–97.5% VDD for broken VSS detection, and Dsat_lo = 0.5–2% VDD for active low saturation.
How many programmable points does the transfer characteristic support in the MLX90367KGO-ACU-000-RE?
The MLX90367KGO-ACU-000-RE supports exactly 3 programmable points (LNR) for linearization-AX, AY, and AS coordinates-as defined in the ACU option code. This is confirmed in Table 1 (Ordering Information) and Section 15.1.3 of the datasheet. Unlike ACV or ACX variants, it does not support 17-point LNR programming or thermal offset correction beyond the base ACU feature set.
What is the SENT frame period and latency for the MLX90367KGO-ACU-000-RE?
The MLX90367KGO-ACU-000-RE has a fixed SENT frame period of 882 μs and internal angle measurement period of 441 μs. Latency from field change to SENT data output is 1745 μs when FILTER = 1 (recommended setting), as specified in Table 8 on page 8 of the datasheet. First sync pulse appears within 1.8 ms of power-on, and first valid data is delivered within 6.3 ms (Tsu2).
Is the MLX90367KGO-ACU-000-RE pin-compatible with other MLX90367 variants in TSSOP-16?
Yes, all MLX90367 variants in TSSOP-16 package-including MLX90367KGO-ACU-000-RE, MLX90367KGO-ACV-000-RE, and MLX90367KGO-ACX-000-RE-share identical pinout, footprint, and electrical interface. Differences are confined to EEPROM-programmable features (LNR point count, thermal correction enablement) and do not affect PCB layout, power sequencing, or SENT signal routing.
MLX90367KGO-ACU-000-RE Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Melexis Technologies NV
- Package/Case:
- 16-TSSOP (0.173", 4.40mm Width)
- Series:
- Triaxis®
- Packaging:
- Tape & Reel (TR)
- Product Status:
- Active
- Programmable:
- -
- For Measuring:
- Linear, Rotary Position
- Technology:
- Hall Effect
- Rotation Angle - Electrical, Mechanical:
- 0° ~ 360°, Continuous
- Linear Range:
- -
- Output:
- SENT
- Output Signal:
- Programmable
- Actuator Type:
- External Magnet, Not Included
- Linearity:
- ±1°
- Resistance:
- -
- Resistance Tolerance:
- -
- Voltage - Supply:
- 4.5V ~ 5.5V
- Mounting Type:
- Surface Mount
- Termination Style:
- Gull Wing
- Operating Temperature:
- -40°C ~ 125°C
- Grade:
- -
- Qualification:
- -
- Supplier Device Package:
- 16-TSSOP
MLX90367KGO-ACU-000-RE FAQ
1.How can I place an order for MLX90367KGO-ACU-000-RE through Aetrix?
Please submit a Request for Quotation (RFQ) for MLX90367KGO-ACU-000-RE on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MLX90367KGO-ACU-000-RE reliable?
The price and inventory of MLX90367KGO-ACU-000-RE are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MLX90367KGO-ACU-000-RE is usually 5 days.
3.What payment methods are accepted for MLX90367KGO-ACU-000-RE?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MLX90367KGO-ACU-000-RE transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MLX90367KGO-ACU-000-RE?
MLX90367KGO-ACU-000-RE orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MLX90367KGO-ACU-000-RE order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MLX90367KGO-ACU-000-RE?
For technical support, including MLX90367KGO-ACU-000-RE datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MLX90367KGO-ACU-000-RE requirements.
6.How does Aetrix verify that MLX90367KGO-ACU-000-RE is sourced from the original manufacturer or authorized distributors?
All MLX90367KGO-ACU-000-RE products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MLX90367KGO-ACU-000-RE meets industry standards.
7.What is the process for return or replacement of MLX90367KGO-ACU-000-RE?
All MLX90367KGO-ACU-000-RE units undergo pre-shipment inspection (PSI). If there is an issue with MLX90367KGO-ACU-000-RE, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MLX90367KGO-ACU-000-RE part is unused and in its original packaging.
Return procedure for MLX90367KGO-ACU-000-RE:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MLX90367KGO-ACU-000-RE Tags

-
TLV493DA1B6HTSA2
Infineon Technologies
-
EVW-AE4001B14
Panasonic Electronic Components

-
3382G-1-103G
Bourns Inc.

-
TLE5501E0001XUMA1
Infineon Technologies

-
HAL830UT-A
TDK-Micronas GmbH

-
TLE5009E1000FUMA1
Infineon Technologies

-
TLE5501E0002XUMA1
Infineon Technologies

-
HAL3725DJ-A
TDK-Micronas GmbH

-
HAL3727DJ-A
TDK-Micronas GmbH
-
HMC1501-TR
Honeywell Aerospace
-
HMC1512-TR
Honeywell Aerospace

-
AAS33001LLEATR-5
Allegro MicroSystems
Tech Hub
Comparator circuit design covering voltage thresholds, input limits, open-collector outputs, LM393 wiring, op-amp differences, hysteresis, timing, window detection and practical fault diagnosis.
Schmitt triggers use separate rising and falling thresholds to stabilize slow or noisy signals. This guide covers hysteresis, 74HC14 and 74HCT14 selection, comparator calculations, RC oscillators and p…
Counterfeit components can hide behind convincing markings and passing basic function tests. This engineering reference covers source traceability, external inspection, X-ray, XRF, electrical testing, …
A practical engineering and sourcing framework covering lifecycle verification, lifetime-buy calculations, replacement qualification, supplier checks and counterfeit-risk controls.
TTL and CMOS logic families differ in thresholds, loading, output drive, power and timing. This engineering guide compares 74HC and 74HCT, calculates noise margins and checks 3.3 V/5 V compatibility.
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …