MLX90373KVS-ABA-100-RE from Melexis is a Triaxis® Hall-based absolute position processor IC for stray-field immune angular rotary sensing in automotive and industrial applications. It delivers 12-bit PSI5 output, operates from -40°C to +125°C, supports programmable piecewise-linear transfer characteristics, and achieves ±0.85° total angle drift over temperature with 0.6° stray-field immunity at 4 kA/m per ISO 11452-8.
For engineers reviewing the MLX90373KVS-ABA-100-RE datasheet, pinout, applications, or equivalent options, this page provides verified technical context, DMP-4 package pin definitions, PSI5 timing compliance (v1.3/v2.1), AEC-Q100 Grade 0 qualification, and functional safety support per ISO 26262 SEooC ASIL-C.
Technical Context
The MLX90373KVS-ABA-100-RE implements Triaxis® Hall sensing architecture with integrated IMC to resolve all three magnetic field components (BX, BY, BZ), enabling robust absolute angle decoding from magnet motion without mechanical contact. Its on-chip DSP performs real-time signal processing including multi-point linearization (up to 32 points), configurable filtering, and diagnostics.
This variant uses the -100 option code, configuring it exclusively for Rotary Stray-Field Immune mode with 4-pole magnet support and magnetic gradient sensitivity of 4.1–10 mT/mm. It communicates via 2-wire PSI5 over supply lines with 300–500 µs cycle time, 850 µs latency, and 1480–2125 µs worst-case step response - all validated under AEC-Q100 stress conditions.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Operating Temp Range | -40°C to +125°C - qualified for under-hood automotive environments per AEC-Q100 Grade 0. |
| Output Protocol | PSI5 v1.3/v2.1 compliant - 2-wire current-modulated interface over supply line, no separate data line required. |
| Angle Accuracy | ±0.85° total drift over temp - enables high-fidelity closed-loop control in throttle/pedal systems without recalibration. |
| Stray-Field Immunity | 0.6° error at 4 kA/m - meets ISO 11452-8 for operation near high-current actuators or motors. |
| Supply Voltage Range | 6–18 V during PSI5 comms - supports wide automotive battery range with integrated undervoltage/overvoltage detection. |
| Quiescent Current | 10–13.5 mA - optimized for always-on position sensing in low-power ECU subsystems. |
| Functional Safety | ISO 26262 SEooC ASIL-C - includes dual watchdogs (IWD/AWD), CRC-protected memory, and diagnostic coverage for safety-critical use. |
Pinout & Package
Dual Mold Package (DMP-4) - PCB-less surface-mount package with straight leads (STD1), RoHS-compliant, designed for direct soldering onto flex or rigid PCBs with minimal footprint and high EMC robustness.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 | VSS | Ground reference for analog/digital domains; must be connected to PCB ground plane for EMC stability. |
| 2 | VDD | Supply input and PSI5 data output node - carries both power and modulated current-sense signal. |
| 3 | N.C. | No internal connection; electrically isolated - recommended to tie to ground for shielding. |
| 4 | VSS | Second ground terminal - improves thermal dissipation and reduces ground loop impedance in noisy environments. |
Key Features
| Feature | Design Value |
|---|---|
| Triaxis® Hall Sensing | Simultaneous BX/BY/BZ measurement enables true 3D magnetic field analysis - eliminates reliance on single-axis approximations and enables stray-field rejection. |
| Programmable Transfer Characteristic | Up to 32-point piecewise-linear calibration - allows precise compensation of non-ideal magnet geometry and mechanical tolerances in final assembly. |
| PSI5 v2.1 Compliance | Supports synchronized multi-sensor networks with deterministic timing - enables time-triggered architectures in ADAS and chassis control ECUs. |
| Stray-Field Immune Mode (-100) | Uses magnetic gradient ∆BXY/∆XY as primary signal - rejects uniform external fields up to 5 mT while maintaining full 0–360° angular resolution. |
| End-of-Line Programmability | 48-bit ID and user-configurable diagnostics via PTC - supports traceability, calibration data storage, and field-upgradable sensor behavior. |
Applications
| Throttle Position Sensing | Pedal Position Sensing |
|---|---|
|
Use Scenario: Real-time detection of accelerator or brake pedal angular displacement in ICE/EV powertrain control units. IC Role / Device Role / Timing Role: Absolute angle sensor providing primary feedback for torque demand mapping and fail-safe limp-home logic. Use Value: ±0.85° total drift ensures consistent pedal-to-torque mapping across temperature; PSI5 interface enables deterministic <2.2 ms step response for fast transient control. |
Use Scenario: Contactless monitoring of driver input angle in electronic throttle control (ETC) and brake-by-wire systems. IC Role / Device Role / Timing Role: Primary position transducer feeding closed-loop actuator control with ASIL-C functional safety compliance. Use Value: 0.6° stray-field immunity prevents erroneous readings near high-current motor drivers; DMP-4 package enables compact integration into pedal modules. |
| Steering Wheel Position Sensing | Ride Height Adjustment |
|
Use Scenario: Absolute angular measurement of steering column rotation for EPS assist torque calculation and lane-keeping systems. IC Role / Device Role / Timing Role: Safety-relevant position input for steering angle estimation, requiring redundancy-ready architecture and diagnostic coverage. Use Value: ISO 26262 SEooC ASIL-C certification validates fault detection mechanisms; 12-bit PSI5 output supports high-resolution angle reporting at 2 kHz update rate. |
Use Scenario: Linear or rotary position feedback for active suspension height adjustment using air or hydraulic actuators. IC Role / Device Role / Timing Role: Robust position monitor operating in harsh under-vehicle environments with exposure to EMI and thermal cycling. Use Value: -40°C to +125°C operation and AEC-Q100 qualification ensure reliability in chassis-mounted locations; DMP-4's PCB-less design resists vibration-induced solder fatigue. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar absolute position sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MLX90373KGO-ABA-100-RE | TSSOP-16 dual-die redundant package with isolation >4 MΩ between dice; higher quiescent current (2×10–13.5 mA). | Required for ASIL-D system decomposition where hardware redundancy is mandated; not suitable for space-constrained DMP-4 footprints. | Select when full hardware redundancy and inter-die isolation are required for highest safety integrity levels. |
| MLX90373KDC-ABA-100-RE | SOIC-8 single-die package with standard leadframe; supports same -100 stray-field mode but lacks DMP-4's PCB-less construction. | Better suited for prototyping or legacy PCB layouts with SOIC-8 footprints; lower thermal performance than DMP-4 in high-power density modules. | Select when leveraging existing SOIC-8 layout or requiring simpler rework capability versus DMP-4's direct-solder construction. |
Compared with MLX90373KVS-ABA-100-RE, the GO variant adds hardware redundancy at the cost of size and power, while the DC variant trades DMP-4's compactness and vibration resilience for standard packaging - all share identical core sensing functionality, PSI5 protocol, and -100 configuration.
Availability
MLX90373KVS-ABA-100-RE is available at Aetrix Electronics and suitable for throttle position sensing, pedal position sensing, and steering wheel position sensing requiring stable component supply across automotive production lifecycles.
Supply support for MLX90373KVS-ABA-100-RE includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Melexis is a Belgian semiconductor company specializing in magnetic sensing, infrared thermometry, and automotive ICs, with over 30 years of sensor innovation and AEC-Q100 leadership.
The MLX90373 product line delivers Triaxis®-based absolute position sensing for safety-critical automotive applications, engineered specifically for stray-field immunity, PSI5 integration, and ISO 26262 compliance in powertrain and chassis systems.
FAQ
What is the primary magnetic sensing mode configured in MLX90373KVS-ABA-100-RE?
The MLX90373KVS-ABA-100-RE is factory-configured for Rotary Stray-Field Immune mode (option code -100), using magnetic gradient ∆BXY/∆XY as its primary signal. This enables accurate 0–360° absolute angle measurement while rejecting uniform external magnetic interference up to 5 mT, as validated per ISO 11452-8. The device does not operate in legacy linear or standard angular modes unless reprogrammed.
Does MLX90373KVS-ABA-100-RE require an external microcontroller to process position data?
No, the MLX90373KVS-ABA-100-RE integrates full signal conditioning, digital processing, and PSI5 output generation on-die. It outputs calibrated 12-bit position data directly via its 2-wire PSI5 interface - no external MCU or ADC is needed for basic operation. Configuration and calibration are performed once via PTC, after which the device operates autonomously.
What package type and lead configuration does MLX90373KVS-ABA-100-RE use?
The MLX90373KVS-ABA-100-RE uses the DMP-4 (Dual Mold Package) with four terminals: two VSS (ground), one VDD (supply/PSI5 output), and one N.C. (no-connect, recommended grounded). It features straight leads (STD1) per ordering code -100, is PCB-less, and designed for direct surface mounting on flex or rigid substrates without a carrier board.
How does MLX90373KVS-ABA-100-RE meet automotive functional safety requirements?
The MLX90373KVS-ABA-100-RE is certified as a Safety Element out of Context (SEooC) per ISO 26262 with ASIL-C capability. It incorporates dual independent watchdogs (IWD and AWD), CRC-protected NVRAM, ECC on critical memory, and diagnostic coverage for sensor front-end, DSP, and communication layers - all documented in Melexis' official safety manual for integration into ASIL-B or ASIL-C systems.
Can MLX90373KVS-ABA-100-RE be used in linear position sensing applications?
No - the MLX90373KVS-ABA-100-RE is specifically configured for Rotary Stray-Field Immune operation and is not intended for linear position sensing. Linear or combined linear/angular applications require option codes -300, -303, or -308 (e.g., MLX90373KVS-ABA-300-RE). Using -100 in linear configurations results in degraded accuracy and invalidates stray-field immunity claims.
MLX90373KVS-ABA-100-RE Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Melexis Technologies NV
- Package/Case:
- 4-SIP Module
- Series:
- Triaxis®
- Packaging:
- Tape & Reel (TR)
- Product Status:
- Active
- Programmable:
- -
- For Measuring:
- Rotary Position
- Technology:
- Hall Effect
- Rotation Angle - Electrical, Mechanical:
- 0° ~ 360°, Continuous
- Linear Range:
- -
- Output:
- Analog Voltage
- Output Signal:
- Programmable
- Actuator Type:
- External Magnet, Not Included
- Linearity:
- ±1°
- Resistance:
- -
- Resistance Tolerance:
- -
- Voltage - Supply:
- 6V ~ 18V
- Mounting Type:
- Through Hole
- Termination Style:
- PC Pin
- Operating Temperature:
- -40°C ~ 125°C
- Grade:
- -
- Qualification:
- -
- Supplier Device Package:
- 4-DMP
MLX90373KVS-ABA-100-RE FAQ
1.How can I place an order for MLX90373KVS-ABA-100-RE through Aetrix?
Please submit a Request for Quotation (RFQ) for MLX90373KVS-ABA-100-RE on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MLX90373KVS-ABA-100-RE reliable?
The price and inventory of MLX90373KVS-ABA-100-RE are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MLX90373KVS-ABA-100-RE is usually 5 days.
3.What payment methods are accepted for MLX90373KVS-ABA-100-RE?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MLX90373KVS-ABA-100-RE transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MLX90373KVS-ABA-100-RE?
MLX90373KVS-ABA-100-RE orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MLX90373KVS-ABA-100-RE order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MLX90373KVS-ABA-100-RE?
For technical support, including MLX90373KVS-ABA-100-RE datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MLX90373KVS-ABA-100-RE requirements.
6.How does Aetrix verify that MLX90373KVS-ABA-100-RE is sourced from the original manufacturer or authorized distributors?
All MLX90373KVS-ABA-100-RE products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MLX90373KVS-ABA-100-RE meets industry standards.
7.What is the process for return or replacement of MLX90373KVS-ABA-100-RE?
All MLX90373KVS-ABA-100-RE units undergo pre-shipment inspection (PSI). If there is an issue with MLX90373KVS-ABA-100-RE, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MLX90373KVS-ABA-100-RE part is unused and in its original packaging.
Return procedure for MLX90373KVS-ABA-100-RE:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MLX90373KVS-ABA-100-RE Tags

-
TLV493DA1B6HTSA2
Infineon Technologies
-
EVW-AE4001B14
Panasonic Electronic Components

-
3382G-1-103G
Bourns Inc.

-
TLE5501E0001XUMA1
Infineon Technologies

-
HAL830UT-A
TDK-Micronas GmbH

-
TLE5009E1000FUMA1
Infineon Technologies

-
TLE5501E0002XUMA1
Infineon Technologies

-
HAL3725DJ-A
TDK-Micronas GmbH

-
HAL3727DJ-A
TDK-Micronas GmbH
-
HMC1501-TR
Honeywell Aerospace
-
HMC1512-TR
Honeywell Aerospace

-
AAS33001LLEATR-5
Allegro MicroSystems
Tech Hub
Comparator circuit design covering voltage thresholds, input limits, open-collector outputs, LM393 wiring, op-amp differences, hysteresis, timing, window detection and practical fault diagnosis.
Schmitt triggers use separate rising and falling thresholds to stabilize slow or noisy signals. This guide covers hysteresis, 74HC14 and 74HCT14 selection, comparator calculations, RC oscillators and p…
Counterfeit components can hide behind convincing markings and passing basic function tests. This engineering reference covers source traceability, external inspection, X-ray, XRF, electrical testing, …
A practical engineering and sourcing framework covering lifecycle verification, lifetime-buy calculations, replacement qualification, supplier checks and counterfeit-risk controls.
TTL and CMOS logic families differ in thresholds, loading, output drive, power and timing. This engineering guide compares 74HC and 74HCT, calculates noise margins and checks 3.3 V/5 V compatibility.
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …