Melexis Technologies NV MLX90373KVS-ABA-103-RE
- Part No.:
- MLX90373KVS-ABA-103-RE
- Manufacturer:
- Melexis Technologies NV
- Category:
- Angle, Linear Position Measuring
- Package:
- 4-SIP Module, Formed Leads
- Datasheet:
-
MLX90373KVS-ABA-103-RE.pdf
- Description:
- SENSOR ROTRY/LNEAR ANLG/PWM 4DMP
- Quantity:
- Payment:

- Shipping:

Inventory:1,694
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MLX90373KVS-ABA-103-RE from Melexis is a Triaxis® Hall-based absolute rotary position sensor IC with stray-field immunity, 2-wire PSI5 v1.3/v2.1 output, AEC-Q100 Grade 0 qualification, and ±0.85° total angular drift over −40°C to +125°C. It operates in DMP-4 package with dual-ground 4-pin configuration and delivers robust angle sensing up to 360° in automotive pedal and throttle applications.
For engineers reviewing the MLX90373KVS-ABA-103-RE datasheet, pinout, applications, or equivalent options, key selection criteria include stray-field immune operation (−10x option code), PSI5 timing compliance (Tcycle = 300–500 µs), angular accuracy under thermal drift, magnetic gradient sensitivity (≥4.1 mT/mm), and functional safety support per ISO 26262 SEooC ASIL-C.
Technical Context
The MLX90373KVS-ABA-103-RE implements Triaxis® Hall technology to measure all three magnetic field components (BX, BY, BZ) for absolute angle decoding. Its on-chip DSP performs real-time piecewise-linear (PWL) transfer function correction using up to 32 programmable points, enabling precise linearization of non-ideal magnet trajectories.
This variant uses the −10x option code, configuring it exclusively for Rotary Stray-Field Immune mode: it processes magnetic in-plane gradient (∆BXY/∆XY) as the useful signal, rejecting uniform stray fields up to 5 mT (4 kA/m) per ISO 11452-8, with immunity validated across full 180° mechanical range.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Operating Temp | −40°C to +125°C - supports under-hood automotive environments without derating. |
| PSI5 Cycle Time | 300–500 µs - enables high-speed closed-loop control at up to 3.3 kHz frame rate. |
| Total Angular Drift | ±0.85° - maximum peak-to-peak deviation relative to 35°C calibration point over lifetime and temperature. |
| Stray-Field Immunity | Up to 5 mT (4 kA/m) - maintains <0.6° error under ISO 11452-8 compliant interference. |
| Magnetic Gradient Sensitivity | ≥4.1 mT/mm - minimum usable signal for nominal accuracy in stray-field immune mode. |
| Supply Voltage Range | 6–18 V - compatible with 12 V automotive battery systems including load-dump transients. |
| Quiescent Current | 10–13.5 mA - power budget compatible with always-on ECU modules. |
Pinout & Package
DMP-4 package: dual-mold, PCB-less, 4-terminal surface-mount device with straight leads (STD2 2.54 mm pitch per ordering legend). No internal PCB; terminals are directly bonded to die.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 | VSS | Ground return path - must be connected to low-impedance chassis ground for EMC stability. |
| 2 | VDD | Supply input / PSI5 data output - powers IC and carries bidirectional PSI5 current-modulated signal. |
| 3 | N.C. | No internal connection - electrically isolated; recommended to tie to ground for shielding. |
| 4 | VSS | Second ground terminal - provides dedicated return for PSI5 current loop, reducing common-mode noise. |
Key Features
| Feature | Design Value |
|---|---|
| Triaxis® Hall Sensing | Simultaneous BX, BY, BZ measurement enables true 3D magnetic field reconstruction for absolute angle decoding without mechanical cam or gear constraints. |
| Stray-Field Immune Mode | Processes ∆BXY/∆XY gradient as primary signal - rejects uniform external fields up to 5 mT while preserving full 0–360° angular resolution. |
| Programmable PWL Transfer | Supports 32-point piecewise-linear calibration - corrects nonlinearities from magnet geometry, air gap variation, and mechanical misalignment in production. |
| AEC-Q100 Grade 0 | Qualified for 125°C ambient operation - meets automotive engine compartment reliability requirements including HTOL, TC, and ESD stress. |
| ISO 26262 SEooC ASIL-C | Delivers safety mechanisms including dual watchdogs (IWD/AWD), ECC-protected NVRAM, and diagnostic coverage for sensor front-end and signal chain. |
Applications
| Throttle Position Sensing | Pedal Position Sensing |
|---|---|
Use Scenario: Real-time detection of accelerator pedal rotation angle in gasoline/diesel powertrains with mechanical linkage or cable-free designs. IC Role / Device Role / Timing Role: Absolute angle sensor providing PSI5-synchronized position feedback to ECU every 300–500 µs for torque demand calculation. Use Value: Enables precise air-fuel ratio control and emission compliance via <±0.85° total drift accuracy across −40°C to +125°C ambient. | Use Scenario: Monitoring brake or clutch pedal angular displacement in brake-by-wire and automated manual transmission systems. IC Role / Device Role / Timing Role: Stray-field immune position processor delivering fail-safe angle data over PSI5 bus despite proximity to high-current actuators and solenoids. Use Value: Maintains <0.6° error under 4 kA/m stray fields per ISO 11452-8, ensuring functional safety integrity in ASIL-B/C architectures. |
| Steering Wheel Position Sensing | Ride Height Position Sensing |
Use Scenario: Measuring steering column rotation for EPS assist torque calculation and lane-keeping assist (LKA) systems. IC Role / Device Role / Timing Role: High-reliability Triaxis® sensor interfacing directly to EPS ECU via 2-wire PSI5, eliminating harness complexity versus analog or SENT solutions. Use Value: Delivers 32-point programmable linearity correction to compensate for steering gear backlash and mounting tolerances. | Use Scenario: Detecting suspension travel in adaptive damping and active ride height control for premium vehicles and commercial chassis. IC Role / Device Role / Timing Role: Absolute linear/rotary position processor operating in harsh under-vehicle environment with wide temperature swing and EMI exposure. Use Value: Dual-ground DMP-4 package and 6–18 V supply range ensure stable operation during cold cranking (6 V) and load dump (18 V) events. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar absolute position sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MLX90374KGO-ABA-103-RE | TSSOP-16 dual-die redundant architecture; higher isolation resistance (4 MΩ); 2× quiescent current (21 mA typical). | Required for ASIL-D systems needing hardware redundancy; not drop-in due to 16-pin footprint and different pinout. | Select when functional safety requires full hardware redundancy and board space permits TSSOP-16 layout. |
| MLX90371KDC-ABA-100-RE | SOIC-8 single-die package; lower max supply (6 V); no stray-field immune mode - limited to legacy angular/linear configurations. | Suitable only for non-critical cabin or body applications; lacks ISO 11452-8 validation and ASIL-C certification. | Choose for cost-sensitive, non-safety-critical designs where 125°C operation and stray-field immunity are not required. |
Compared with MLX90373KVS-ABA-103-RE, the MLX90374KGO-ABA-103-RE adds hardware redundancy at the cost of doubled current and larger footprint, while the MLX90371KDC-ABA-100-RE sacrifices stray-field immunity, ASIL-C compliance, and extended voltage range for SOIC-8 simplicity and lower BOM cost.
Availability
MLX90373KVS-ABA-103-RE is available at Aetrix Electronics and suitable for automotive throttle position sensing, pedal position monitoring, and steering angle measurement requiring stable component supply across extended temperature ranges and stringent EMI environments.
Supply support for MLX90373KVS-ABA-103-RE includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Melexis is a Belgian semiconductor company specializing in magnetic sensing, infrared thermometry, and automotive ICs, with design centers in Europe and manufacturing partnerships worldwide.
The MLX90373 belongs to Melexis' Triaxis® position processor product line, engineered specifically for high-accuracy, stray-field immune absolute angle and linear position sensing in automotive powertrain, chassis, and ADAS systems.
FAQ
What is the primary magnetic sensing mode configured for MLX90373KVS-ABA-103-RE?
The MLX90373KVS-ABA-103-RE is factory-configured for Rotary Stray-Field Immune mode (−10x option code), which uses magnetic in-plane gradient (∆BXY/∆XY) as the primary signal. This mode enables immunity to uniform external fields up to 5 mT and supports full 0–360° absolute angle measurement with <0.6° error under ISO 11452-8 test conditions. The MLX90373KVS-ABA-103-RE does not support legacy angular or linear modes unless reprogrammed via PTC.
Does MLX90373KVS-ABA-103-RE support PSI5 v2.1 communication?
Yes, MLX90373KVS-ABA-103-RE fully supports PSI5 v2.1 protocol as specified in its datasheet Revision 2.0. It complies with cycle times of 300–500 µs, bit timing of 5–8.4 µs, and synchronous mode sync pulse hold time ≥9 µs. The MLX90373KVS-ABA-103-RE also maintains backward compatibility with PSI5 v1.3, allowing seamless integration into existing ECU platforms without firmware updates.
What is the maximum allowable stray magnetic field for MLX90373KVS-ABA-103-RE without degrading accuracy?
The MLX90373KVS-ABA-103-RE maintains ≤0.6° angular error under stray magnetic fields up to 5 mT (4 kA/m) applied from any direction, as validated per ISO 11452-8:2015. This performance is guaranteed only in Rotary Stray-Field Immune mode (−10x), where the device processes magnetic gradient rather than absolute flux density. The MLX90373KVS-ABA-103-RE's immunity scales linearly with both useful field strength and disturbing field magnitude.
Can MLX90373KVS-ABA-103-RE be used in linear position sensing applications?
No - MLX90373KVS-ABA-103-RE is specifically configured for Rotary Stray-Field Immune operation (option code −103) and does not support linear position sensing modes. Linear applications require −30x option codes (e.g., ABA-300/303/308) that enable legacy x-y, x-z, or y-z sensing configurations. Using MLX90373KVS-ABA-103-RE for linear displacement would result in undefined behavior and uncalibrated output due to mismatched magnetic transfer function.
What packaging and lead configuration does MLX90373KVS-ABA-103-RE use?
MLX90373KVS-ABA-103-RE uses the DMP-4 (Dual Mould Package) - a PCB-less, 4-terminal surface-mount device with STD2 trim-and-form leads spaced at 2.54 mm pitch. Its pinout is VSS–VDD–N.C.–VSS, with two dedicated ground terminals for enhanced PSI5 current-loop integrity and EMC robustness. The MLX90373KVS-ABA-103-RE is delivered in tape-and-reel (RE) format with face-up orientation.
MLX90373KVS-ABA-103-RE Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Melexis Technologies NV
- Package/Case:
- 4-SIP Module, Formed Leads
- Series:
- Triaxis®
- Packaging:
- Tape & Reel (TR)
- Product Status:
- Not For New Designs
- Programmable:
- -
- For Measuring:
- Rotary Position
- Technology:
- Hall Effect
- Rotation Angle - Electrical, Mechanical:
- 0° ~ 360°, Continuous
- Linear Range:
- -
- Output:
- Analog Voltage
- Output Signal:
- Programmable
- Actuator Type:
- External Magnet, Not Included
- Linearity:
- ±1°
- Resistance:
- -
- Resistance Tolerance:
- -
- Voltage - Supply:
- 6V ~ 18V
- Mounting Type:
- Through Hole
- Termination Style:
- PC Pin
- Operating Temperature:
- -40°C ~ 125°C
- Grade:
- -
- Qualification:
- -
- Supplier Device Package:
- 4-DMP
MLX90373KVS-ABA-103-RE FAQ
1.How can I place an order for MLX90373KVS-ABA-103-RE through Aetrix?
Please submit a Request for Quotation (RFQ) for MLX90373KVS-ABA-103-RE on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MLX90373KVS-ABA-103-RE reliable?
The price and inventory of MLX90373KVS-ABA-103-RE are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MLX90373KVS-ABA-103-RE is usually 5 days.
3.What payment methods are accepted for MLX90373KVS-ABA-103-RE?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MLX90373KVS-ABA-103-RE transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MLX90373KVS-ABA-103-RE?
MLX90373KVS-ABA-103-RE orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MLX90373KVS-ABA-103-RE order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MLX90373KVS-ABA-103-RE?
For technical support, including MLX90373KVS-ABA-103-RE datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MLX90373KVS-ABA-103-RE requirements.
6.How does Aetrix verify that MLX90373KVS-ABA-103-RE is sourced from the original manufacturer or authorized distributors?
All MLX90373KVS-ABA-103-RE products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MLX90373KVS-ABA-103-RE meets industry standards.
7.What is the process for return or replacement of MLX90373KVS-ABA-103-RE?
All MLX90373KVS-ABA-103-RE units undergo pre-shipment inspection (PSI). If there is an issue with MLX90373KVS-ABA-103-RE, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MLX90373KVS-ABA-103-RE part is unused and in its original packaging.
Return procedure for MLX90373KVS-ABA-103-RE:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MLX90373KVS-ABA-103-RE Tags

-
TLV493DA1B6HTSA2
Infineon Technologies
-
EVW-AE4001B14
Panasonic Electronic Components

-
3382G-1-103G
Bourns Inc.

-
TLE5501E0001XUMA1
Infineon Technologies

-
HAL830UT-A
TDK-Micronas GmbH

-
TLE5009E1000FUMA1
Infineon Technologies

-
TLE5501E0002XUMA1
Infineon Technologies

-
HAL3725DJ-A
TDK-Micronas GmbH

-
HAL3727DJ-A
TDK-Micronas GmbH
-
HMC1501-TR
Honeywell Aerospace
-
HMC1512-TR
Honeywell Aerospace

-
AAS33001LLEATR-5
Allegro MicroSystems
Tech Hub
Comparator circuit design covering voltage thresholds, input limits, open-collector outputs, LM393 wiring, op-amp differences, hysteresis, timing, window detection and practical fault diagnosis.
Schmitt triggers use separate rising and falling thresholds to stabilize slow or noisy signals. This guide covers hysteresis, 74HC14 and 74HCT14 selection, comparator calculations, RC oscillators and p…
Counterfeit components can hide behind convincing markings and passing basic function tests. This engineering reference covers source traceability, external inspection, X-ray, XRF, electrical testing, …
A practical engineering and sourcing framework covering lifecycle verification, lifetime-buy calculations, replacement qualification, supplier checks and counterfeit-risk controls.
TTL and CMOS logic families differ in thresholds, loading, output drive, power and timing. This engineering guide compares 74HC and 74HCT, calculates noise margins and checks 3.3 V/5 V compatibility.
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …