Melexis Technologies NV MLX90376GGO-ABA-630-RE
- Part No.:
- MLX90376GGO-ABA-630-RE
- Manufacturer:
- Melexis Technologies NV
- Category:
- Angle, Linear Position Measuring
- Package:
- 16-TSSOP (0.173", 4.40mm Width) Exposed Pad
- Datasheet:
-
MLX90376GGO-ABA-630-RE.pdf
- Description:
- TRIAXIS POSITION SENSOR, 360 DEG
- Quantity:
- Payment:

- Shipping:

Inventory:3,603
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MLX90376GGO-ABA-630-RE from Melexis is a Triaxis® monolithic magnetic position sensor IC for rotary 360° stray-field immune angle sensing, featuring SENT (SAE J2716 APR2016) output with 3 μs tick time, AEC-Q100 Grade-0 qualification (−40 °C to +160 °C), and dual-die TSSOP-16_EP package. It delivers ASIL C functional safety compliance for SENT mode and robustness against stray fields up to 5 mT.
For engineers reviewing the MLX90376GGO-ABA-630-RE datasheet, pinout, applications, or equivalent options, this page provides verified technical context, SENT timing specs, dual-die isolation data, stray-field immunity validation, and automotive-grade functional safety implementation details.
Technical Context
The MLX90376GGO-ABA-630-RE implements Triaxis® Hall sensing of Bx, By, and Bz magnetic components to compute absolute angular position without mechanical contact. Its dual-die architecture in TSSOP-16_EP enables redundancy and isolation resistance ≥4 MΩ between dies.
This variant is factory-configured for Rotary Stray-Field Immune Mode (360°), SENT output only (3 μs tick), high-speed operation, and operates across −40 °C to +160 °C with supply voltage 4.5–5.5 V. It supports ISO 26262 SEooC with ASIL C for SENT output and includes built-in diagnostics including CRC, watchdog, and broken-wire detection.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Output Protocol | SENT (SAE J2716 APR2016) with 3 μs tick time - enables secure, error-coded serial transmission compatible with automotive ECUs. |
| Operating Temperature | −40 °C to +160 °C - qualified per AEC-Q100 Grade-0 for under-hood automotive applications. |
| Functional Safety | ISO 26262 SEooC, ASIL C for SENT output - supports safety-critical steering and throttle position systems. |
| Magnetic Immunity | Stray-field immune up to 5 mT (4 kA/m) per ISO 11452-8 - maintains accuracy in high-interference environments like electric powertrains. |
| Package | TSSOP-16_EP (GO code) - dual-die configuration with exposed pad for thermal management and die-to-die isolation ≥4 MΩ. |
| Supply Current | Typ. 11 mA per die (22 mA total) - optimized for low-power SENT operation while maintaining fast startup and refresh. |
| Startup Time | Tstup ≤ 13.3 ms (safe startup) - ensures rapid valid-angle delivery after power-on reset for real-time control loops. |
Pinout & Package
TSSOP-16_EP (GO) package with exposed pad (EP) for thermal dissipation and mechanical stability; dual-die layout enables redundant signal paths and functional safety separation.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1, 8, 10, 16 | NC | Not connected - recommended to tie to ground for EMC performance. |
| 2, 9 | VDEC1 / VDEC2 | Decoupling pins for die 1 and die 2 - require local 100 nF ceramic capacitors to VSS for noise suppression. |
| 3, 11 | OUT1 / OUT2 | Dual SENT outputs - support independent diagnostic comparison or voting logic for ASIL C compliance. |
| 4, 12 | TEST1 / TEST2 | Factory test access - not intended for end-user use; tie to ground if unused. |
| 5, 13 | VSS1 / VSS2 | Separate ground terminals per die - enable isolation measurement and fault containment. |
| 6, 14 | VDD1 / VDD2 | Independent supply inputs per die - allow supply monitoring and independent power domain control. |
| 7, 15 | INPUT1 / INPUT2 | Test input pins - used during production testing; no functional role in operation. |
Key Features
| Feature | Design Value |
|---|---|
| Triaxis® 3D Hall Sensing | Simultaneous measurement of Bx, By, Bz enables true 360° absolute angle decoding without external concentrators or complex magnet assemblies. |
| SENT Output with CRC | Secure Sensor format with embedded error codes and user-defined values - eliminates need for external protocol translation or checksum verification hardware. |
| Stray-Field Immunity | Valid 360° angle output under 5 mT external DC/AC interference - certified per ISO 11452-8, enabling placement near motors and inverters. |
| Dual-Die Redundancy | Independent dies with isolated VDD/VSS paths and ≥4 MΩ inter-die resistance - supports diagnostic cross-checking and fault-tolerant architectures. |
| Programmable Diagnostics | Configurable DTI (Diagnostic Test Interval), watchdog timeout, and broken-wire detection thresholds - allows tailoring to specific ECU timing and safety requirements. |
Applications
| Steering Wheel Position Sensing | Throttle Valve Position Sensing |
|---|---|
Use Scenario: Real-time angular feedback for EPS (Electric Power Steering) control and torque overlay algorithms. IC Role / Device Role / Timing Role: Primary 360° absolute angle sensor delivering SENT frames at ≤13.3 ms safe startup latency for closed-loop motor control. Use Value: Stray-field immunity ensures stable operation near high-current steering motor windings and battery cables. | Use Scenario: Monitoring throttle plate rotation in gasoline/diesel engines and hybrid powertrain air management systems. IC Role / Device Role / Timing Role: Safety-critical position transducer with ASIL C compliance and dual-die output for redundancy validation. Use Value: SENT output with CRC enables deterministic ECU interpretation and immediate fault flagging without protocol overhead. |
| Ride Height Control Sensing | Rotary Actuator Feedback |
Use Scenario: Suspension height monitoring in adaptive damping and air suspension systems for vehicle leveling and ride comfort. IC Role / Device Role / Timing Role: Non-contact rotary position sensor operating continuously at 160 °C ambient in chassis-mounted modules. Use Value: AEC-Q100 Grade-0 rating and robust packaging ensure long-term reliability in thermally aggressive under-vehicle locations. | Use Scenario: Closed-loop position feedback for electric rotary actuators in HVAC dampers, transmission shift-by-wire, and brake caliper control. IC Role / Device Role / Timing Role: High-speed SENT interface synchronized to actuator control loop with <200 μs output refresh period. Use Value: Dual-die architecture allows cross-die consistency checking to detect single-point failures before actuator mispositioning occurs. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar magnetic position sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MLX90376GGO-ABA-600-RE | Analog/PWM output (low-power mode), no SENT; same 360° stray-field immune configuration and TSSOP-16_EP package. | Suitable for legacy ECU interfaces requiring ratiometric analog or PWM, not digital serial protocols. | Select when SENT infrastructure is unavailable or system cost targets exclude protocol translation hardware. |
| MLX90376GGO-ABA-610-RE | Analog/PWM output (high-speed mode); identical package, temperature range, and magnetic performance but different output stage and timing. | Used where faster analog refresh (200 μs) is prioritized over digital diagnostics and CRC-protected communication. | Choose for non-safety-critical applications needing minimal latency without functional safety certification overhead. |
Compared with MLX90376GGO-ABA-630-RE, the -600-RE variant trades SENT's error resilience and ASIL C readiness for analog simplicity, while the -610-RE retains high-speed analog timing but lacks SENT's deterministic frame structure and integrated diagnostics - making the -630-RE uniquely suited for new ASIL C–compliant automotive designs requiring serial position reporting.
Availability
MLX90376GGO-ABA-630-RE is available at Aetrix Electronics and suitable for steering wheel position sensing, throttle valve position sensing, and ride height control requiring stable component supply across automotive production lifecycles.
Supply support for MLX90376GGO-ABA-630-RE includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Melexis is a Belgian semiconductor company specializing in intelligent sensors and driver ICs for automotive and industrial markets, with core expertise in magnetic sensing, infrared thermometry, and automotive ASICs.
The MLX90376 product line delivers Triaxis® 3D Hall-based absolute position sensing for safety-critical automotive applications, designed specifically to meet AEC-Q100, ISO 26262, and stray-field immunity requirements in powertrain and chassis systems.
FAQ
What output protocol does the MLX90376GGO-ABA-630-RE support?
The MLX90376GGO-ABA-630-RE is factory-configured exclusively for SENT (SAE J2716 APR2016) output with a 3 μs tick time. It does not support analog, PWM, or SPC modes - the output protocol is fixed by option code ABA-630 and cannot be reprogrammed in the field. This ensures deterministic timing and ASIL C compliance for automotive safety applications.
Is the MLX90376GGO-ABA-630-RE pin-compatible with other MLX90376 variants in TSSOP-16_EP?
Yes, the MLX90376GGO-ABA-630-RE shares identical pinout and footprint with all GO-code MLX90376 variants in TSSOP-16_EP, including -600-RE and -610-RE. However, output behavior differs: -630-RE drives SENT on both OUT1 and OUT2, while -600-RE and -610-RE deliver analog/PWM signals. PCB layout is interchangeable, but firmware and ECU interface must match the selected output mode.
Does the MLX90376GGO-ABA-630-RE support functional safety certification?
Yes, the MLX90376GGO-ABA-630-RE is certified per ISO 26262 SEooC with ASIL C for its SENT output path, and AEC-Q100 Grade-0 qualified (−40 °C to +160 °C). Its dual-die TSSOP-16_EP package enables hardware-level redundancy, and built-in diagnostics - including CRC, watchdog timers, and broken-wire detection - are fully documented in the safety manual for integration into ASIL C systems.
What is the magnetic stray-field immunity specification for the MLX90376GGO-ABA-630-RE?
The MLX90376GGO-ABA-630-RE achieves stray-field immune 360° angle sensing up to 5 mT (4 kA/m) as validated per ISO 11452-8. This is enabled by Triaxis® technology and on-chip signal processing that rejects orthogonal interference - critical for placement near electric motors, inverters, or high-current busbars in modern vehicle architectures.
How is power supply decoupling implemented for the MLX90376GGO-ABA-630-RE?
The MLX90376GGO-ABA-630-RE requires two dedicated decoupling paths: VDEC1 (pin 2) and VDEC2 (pin 9), each connected to a local 100 nF ceramic capacitor routed to its respective VSS1 (pin 5) and VSS2 (pin 13). This dual-path design maintains noise isolation between dies and ensures stable operation under fast transient loads typical in SENT communication bursts.
MLX90376GGO-ABA-630-RE Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Melexis Technologies NV
- Package/Case:
- 16-TSSOP (0.173", 4.40mm Width) Exposed Pad
- Series:
- -
- Packaging:
- Tape & Reel (TR)
- Product Status:
- Active
- Programmable:
- -
- For Measuring:
- Rotary Position
- Technology:
- Hall Effect
- Rotation Angle - Electrical, Mechanical:
- 0° ~ 360°, Continuous
- Linear Range:
- -
- Output:
- SPC
- Output Signal:
- Programmable
- Actuator Type:
- External Magnet, Not Included
- Linearity:
- ±1°
- Resistance:
- -
- Resistance Tolerance:
- -
- Voltage - Supply:
- 4.5V ~ 5.5V
- Mounting Type:
- Surface Mount
- Termination Style:
- Gull Wing
- Operating Temperature:
- -40°C ~ 160°C
- Grade:
- Automotive
- Qualification:
- AEC-Q100
- Supplier Device Package:
- 16-TSSOP-EP
MLX90376GGO-ABA-630-RE FAQ
1.How can I place an order for MLX90376GGO-ABA-630-RE through Aetrix?
Please submit a Request for Quotation (RFQ) for MLX90376GGO-ABA-630-RE on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MLX90376GGO-ABA-630-RE reliable?
The price and inventory of MLX90376GGO-ABA-630-RE are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MLX90376GGO-ABA-630-RE is usually 5 days.
3.What payment methods are accepted for MLX90376GGO-ABA-630-RE?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MLX90376GGO-ABA-630-RE transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MLX90376GGO-ABA-630-RE?
MLX90376GGO-ABA-630-RE orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MLX90376GGO-ABA-630-RE order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MLX90376GGO-ABA-630-RE?
For technical support, including MLX90376GGO-ABA-630-RE datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MLX90376GGO-ABA-630-RE requirements.
6.How does Aetrix verify that MLX90376GGO-ABA-630-RE is sourced from the original manufacturer or authorized distributors?
All MLX90376GGO-ABA-630-RE products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MLX90376GGO-ABA-630-RE meets industry standards.
7.What is the process for return or replacement of MLX90376GGO-ABA-630-RE?
All MLX90376GGO-ABA-630-RE units undergo pre-shipment inspection (PSI). If there is an issue with MLX90376GGO-ABA-630-RE, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MLX90376GGO-ABA-630-RE part is unused and in its original packaging.
Return procedure for MLX90376GGO-ABA-630-RE:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MLX90376GGO-ABA-630-RE Tags

-
TLV493DA1B6HTSA2
Infineon Technologies
-
EVW-AE4001B14
Panasonic Electronic Components

-
3382G-1-103G
Bourns Inc.

-
TLE5501E0001XUMA1
Infineon Technologies

-
HAL830UT-A
TDK-Micronas GmbH

-
TLE5009E1000FUMA1
Infineon Technologies

-
TLE5501E0002XUMA1
Infineon Technologies

-
HAL3725DJ-A
TDK-Micronas GmbH

-
HAL3727DJ-A
TDK-Micronas GmbH
-
HMC1501-TR
Honeywell Aerospace
-
HMC1512-TR
Honeywell Aerospace

-
AAS33001LLEATR-5
Allegro MicroSystems
Tech Hub
Comparator circuit design covering voltage thresholds, input limits, open-collector outputs, LM393 wiring, op-amp differences, hysteresis, timing, window detection and practical fault diagnosis.
Schmitt triggers use separate rising and falling thresholds to stabilize slow or noisy signals. This guide covers hysteresis, 74HC14 and 74HCT14 selection, comparator calculations, RC oscillators and p…
Counterfeit components can hide behind convincing markings and passing basic function tests. This engineering reference covers source traceability, external inspection, X-ray, XRF, electrical testing, …
A practical engineering and sourcing framework covering lifecycle verification, lifetime-buy calculations, replacement qualification, supplier checks and counterfeit-risk controls.
TTL and CMOS logic families differ in thresholds, loading, output drive, power and timing. This engineering guide compares 74HC and 74HCT, calculates noise margins and checks 3.3 V/5 V compatibility.
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …