Melexis Technologies NV MLX90377GGO-ADB-330-TU
- Part No.:
- MLX90377GGO-ADB-330-TU
- Manufacturer:
- Melexis Technologies NV
- Category:
- Angle, Linear Position Measuring
- Package:
- 16-TSSOP (0.173", 4.40mm Width)
- Datasheet:
-
MLX90377GGO-ADB-330-TU.pdf
- Description:
- SENSOR RTRY/LNR ANLG/PWM 16TSSOP
- Quantity:
- Payment:

- Shipping:

Inventory:3,899
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MLX90377GGO-ADB-330-TU from Melexis is a Triaxis® monolithic magnetic position sensor IC for absolute rotary or linear position sensing. It delivers 12-bit SENT output with 3 μs tick time, operates from -40°C to 160°C, and features ASIL-C functional safety compliance for SENT mode. Used in automotive throttle and pedal position sensing where stray-field immunity and protocol reliability are critical.
For engineers reviewing the MLX90377GGO-ADB-330-TU datasheet, pinout, applications, or equivalent options, this page provides verified package mapping (TSSOP-16), SENT timing parameters, ASIL-C safety architecture, magnetic accuracy specs per SAE J2716 APR2016, and validated alternative options for automotive position-sensing designs.
Technical Context
The MLX90377GGO-ADB-330-TU implements Triaxis® Hall sensing of Bx, By, and Bz magnetic components to compute absolute angular or linear position without mechanical contact. Its on-chip DSP supports programmable piecewise-linear transfer characteristics (up to 32 segments) and real-time signal conditioning for robust operation under EMI and thermal stress.
This variant is configured exclusively for SENT output (3 μs tick time), uses the TSSOP-16 dual-die package for redundancy, and meets ISO 26262 ASIL-C requirements as a Safety Element out of Context. It does not support analog, PWM, or SPC modes - output protocol is fixed at factory via ADB-330 option code.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Output Protocol | SAE J2716 APR2016 SENT with 3 μs tick time - enables deterministic, error-coded position reporting compatible with automotive ECUs. |
| Resolution | 12-bit position data - delivers ≤0.1° angular resolution over 0–360° full scale for high-fidelity control feedback. |
| Operating Temp | -40°C to +160°C - qualified for under-hood automotive environments including transmission, throttle, and suspension modules. |
| Safety Rating | ISO 26262 ASIL-C (SENT mode only) - certified for safety-critical position sensing without external safety monitor. |
| Supply Range | 4.5 V to 5.5 V (regulated) or 6 V to 18 V (battery) - supports direct connection to vehicle battery with integrated reverse-polarity protection. |
| Magnetic Sensing | Triaxis® 3D Hall front-end - measures Bx, By, Bz simultaneously to reject stray fields and enable compact magnet placement. |
| Package | TSSOP-16 dual-die - provides physical redundancy and >4 MΩ isolation between dies for fault-tolerant system design. |
Pinout & Package
TSSOP-16 package with dual-die architecture for functional redundancy and die-to-die isolation. Pins include dedicated supply/ground pairs per die, independent outputs, and decoupling terminals for EMC-optimized layout.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1, 9 | VDEC1 / VDEC2 | Dedicated decoupling pins per die - require local 100 nF ceramic capacitors to minimize noise coupling between sensor dies. |
| 2, 10 | VSS1 / VSS2 | Independent ground returns per die - maintain isolation integrity; must not be shorted externally. |
| 3, 11 | VDD1 / VDD2 | Separate supply inputs per die - enable independent power sequencing and fault containment. |
| 6, 15 | OUT2 / OUT1 | Independent SENT outputs - support dual-channel validation or voting logic in ASIL-C systems. |
| 4, 12 | Input1 / Input2 | Test/external measurement inputs - unused in production; recommended tied to VSS for EMC. |
| 5, 13 | Test2 / Test1 | Factory test access - not user-accessible; tie to VSS for optimal noise immunity. |
| 7, 8, 14, 16 | N.C. | No-connect pins - must be left floating or grounded per Melexis EMC recommendation; no internal connection. |
Key Features
| Feature | Design Value |
|---|---|
| Triaxis® 3D Hall Sensing | Simultaneous Bx/By/Bz measurement enables true absolute position decoding with inherent stray-field rejection - eliminates need for shielding in space-constrained assemblies. |
| Programmable Transfer Curve | Up to 32-point piecewise-linear calibration stored in NVRAM - allows precise linearization across non-ideal magnet trajectories without host MCU intervention. |
| SENT Protocol Compliance | Full SAE J2716 APR2016 implementation with CRC, status nibbles, and configurable message content - ensures interoperability with Tier-1 ECU receivers. |
| Dual-Die Redundancy | Independent sensor dies in single TSSOP-16 package with >4 MΩ inter-die isolation - supports lockstep or cross-check architectures for ASIL-C fault detection. |
| Stray-Field Immunity | Configured in Standard/Legacy Mode (-3xx) - optimized for typical automotive magnet placements where external field interference is moderate but unshielded. |
Applications
| Throttle Position Sensing | Pedal Position Sensing |
|---|---|
Use Scenario: Real-time monitoring of accelerator pedal angle in gasoline/diesel powertrains for engine torque control and emissions management. IC Role / Device Role / Timing Role: Absolute angular position sensor delivering SENT frames every 2–5 ms to ECU for closed-loop fuel injection timing. Use Value: 12-bit resolution and ASIL-C compliance ensure precise throttle actuation within ±0.5° accuracy while meeting ISO 26262 diagnostic coverage requirements. |
Use Scenario: Detection of brake or accelerator pedal displacement in ADAS-equipped vehicles for regenerative braking coordination and collision avoidance. IC Role / Device Role / Timing Role: Linear position transducer providing SENT-encoded stroke data synchronized to vehicle CAN bus timing windows. Use Value: Dual-die TSSOP-16 package enables redundant signal paths for fail-operational behavior during pedal sensor faults. |
| Ride Height Control | Steering Wheel Angle Sensing |
Use Scenario: Monitoring suspension travel in adaptive air ride systems to adjust damping and vehicle leveling in real time. IC Role / Device Role / Timing Role: Linear displacement sensor interfacing with chassis controller via SENT, operating continuously at 125°C ambient. Use Value: -40°C to +160°C rating and stray-field tolerance allow direct mounting near coil springs without thermal derating or shielding. |
Use Scenario: Measuring absolute steering wheel rotation for electronic power steering (EPS) assist torque calculation and lane-keeping assist (LKA) input. IC Role / Device Role / Timing Role: Rotary position encoder supplying 360° absolute angle with SENT output synchronized to EPS microcontroller interrupt timing. Use Value: Triaxis® 3D sensing rejects interference from nearby motors and wiring harnesses, eliminating calibration drift in EPS assemblies. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar absolute position sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MLX90377GGO-ADB-310-TU | Same TSSOP-16 package and temperature range, but configured for high-speed PWM output instead of SENT. | Used where ECU lacks SENT receiver but requires fast position updates (e.g., legacy powertrain controllers). | Select when PWM interface compatibility outweighs ASIL-C certification needs. |
| MLX90377GDC-ADB-330-TU | Identical SENT configuration and firmware, but in SOIC-8 single-die package - no die isolation or redundancy. | Suitable for non-safety-critical applications like HVAC flap control or seat position where cost and footprint are prioritized. | Choose for cost-sensitive designs where ASIL-C is not mandated and board space permits SOIC-8. |
Compared with MLX90377GGO-ADB-330-TU, the ADB-310 variant trades SENT protocol compliance and ASIL-C capability for faster PWM response, while the ADB-330 in SOIC-8 retains identical functionality but removes hardware-level redundancy - making the TSSOP-16 dual-die version uniquely suited for fault-tolerant automotive safety systems.
Availability
MLX90377GGO-ADB-330-TU is available at Aetrix Electronics and suitable for automotive throttle position sensing, pedal position sensing, and ride height control requiring stable component supply across extended temperature ranges and functional safety compliance.
Supply support for MLX90377GGO-ADB-330-TU includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Melexis is a Belgian semiconductor company specializing in magnetic sensing, infrared thermometry, and automotive ICs, with ISO/TS 16949-certified manufacturing and functional safety expertise.
The MLX90377 product line delivers Triaxis®-based absolute position sensing for automotive and industrial motion control, designed specifically to replace potentiometers and resolver-based systems with robust, contactless alternatives.
FAQ
What output protocol does the MLX90377GGO-ADB-330-TU support?
The MLX90377GGO-ADB-330-TU supports only SENT output with 3 μs tick time, per its ADB-330 option code. It cannot be reprogrammed to analog, PWM, or SPC modes - the protocol is hard-configured at factory. This ensures deterministic timing and SAE J2716 APR2016 compliance for automotive ECU integration.
Is the MLX90377GGO-ADB-330-TU pin-compatible with other MLX90377 variants in TSSOP-16?
Yes, all MLX90377 variants in TSSOP-16 (GO package code) share identical pinout and footprint, including MLX90377GGO-ADB-330-TU. Pin assignments for VDD, VSS, OUT, VDEC, and test terminals are fixed per Melexis datasheet Section 3.2 - enabling drop-in replacement across output-mode variants without PCB changes.
Does the MLX90377GGO-ADB-330-TU meet ISO 26262 ASIL-C requirements?
Yes, the MLX90377GGO-ADB-330-TU is certified ASIL-C capable for SENT output mode as a Safety Element out of Context (SEooC), per ISO 26262 Part 10. This applies only to SENT operation - analog mode is rated ASIL-B, and PWM/SPC modes have separate safety classifications. The dual-die TSSOP-16 package supports required fault-detection mechanisms.
What is the magnetic field range supported by the MLX90377GGO-ADB-330-TU?
The MLX90377GGO-ADB-330-TU operates in Standard/Legacy Mode (-3xx), supporting magnetic flux densities from ±1 T (±10,000 G) with guaranteed performance across -40°C to +160°C. Its Triaxis® architecture enables accurate position decoding even with off-axis or skewed magnet orientations, reducing mechanical assembly tolerances.
Can the MLX90377GGO-ADB-330-TU be used in linear position sensing applications?
Yes, the MLX90377GGO-ADB-330-TU supports both absolute rotary (0–360°) and linear position sensing via appropriate magnet geometry and magnetic circuit design. Its 3D Hall front-end captures Bx, By, Bz components to resolve linear displacement - confirmed in Melexis Application Examples for float-level and small-stroke sensors.
MLX90377GGO-ADB-330-TU Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Melexis Technologies NV
- Package/Case:
- 16-TSSOP (0.173", 4.40mm Width)
- Series:
- -
- Packaging:
- Tube
- Product Status:
- Active
- Programmable:
- -
- For Measuring:
- Linear, Rotary Position
- Technology:
- Hall Effect
- Rotation Angle - Electrical, Mechanical:
- 0° ~ 360°, Continuous
- Linear Range:
- -
- Output:
- SENT
- Output Signal:
- Programmable
- Actuator Type:
- External Magnet, Not Included
- Linearity:
- ±1°
- Resistance:
- -
- Resistance Tolerance:
- -
- Voltage - Supply:
- 4.5V ~ 5.5V
- Mounting Type:
- Surface Mount
- Termination Style:
- Gull Wing
- Operating Temperature:
- -40°C ~ 160°C
- Grade:
- -
- Qualification:
- -
- Supplier Device Package:
- 16-TSSOP
MLX90377GGO-ADB-330-TU FAQ
1.How can I place an order for MLX90377GGO-ADB-330-TU through Aetrix?
Please submit a Request for Quotation (RFQ) for MLX90377GGO-ADB-330-TU on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MLX90377GGO-ADB-330-TU reliable?
The price and inventory of MLX90377GGO-ADB-330-TU are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MLX90377GGO-ADB-330-TU is usually 5 days.
3.What payment methods are accepted for MLX90377GGO-ADB-330-TU?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MLX90377GGO-ADB-330-TU transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MLX90377GGO-ADB-330-TU?
MLX90377GGO-ADB-330-TU orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MLX90377GGO-ADB-330-TU order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MLX90377GGO-ADB-330-TU?
For technical support, including MLX90377GGO-ADB-330-TU datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MLX90377GGO-ADB-330-TU requirements.
6.How does Aetrix verify that MLX90377GGO-ADB-330-TU is sourced from the original manufacturer or authorized distributors?
All MLX90377GGO-ADB-330-TU products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MLX90377GGO-ADB-330-TU meets industry standards.
7.What is the process for return or replacement of MLX90377GGO-ADB-330-TU?
All MLX90377GGO-ADB-330-TU units undergo pre-shipment inspection (PSI). If there is an issue with MLX90377GGO-ADB-330-TU, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MLX90377GGO-ADB-330-TU part is unused and in its original packaging.
Return procedure for MLX90377GGO-ADB-330-TU:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MLX90377GGO-ADB-330-TU Tags

-
TLV493DA1B6HTSA2
Infineon Technologies
-
EVW-AE4001B14
Panasonic Electronic Components

-
3382G-1-103G
Bourns Inc.

-
TLE5501E0001XUMA1
Infineon Technologies

-
HAL830UT-A
TDK-Micronas GmbH

-
TLE5009E1000FUMA1
Infineon Technologies

-
TLE5501E0002XUMA1
Infineon Technologies

-
HAL3725DJ-A
TDK-Micronas GmbH

-
HAL3727DJ-A
TDK-Micronas GmbH
-
HMC1501-TR
Honeywell Aerospace
-
HMC1512-TR
Honeywell Aerospace

-
AAS33001LLEATR-5
Allegro MicroSystems
Tech Hub
Comparator circuit design covering voltage thresholds, input limits, open-collector outputs, LM393 wiring, op-amp differences, hysteresis, timing, window detection and practical fault diagnosis.
Schmitt triggers use separate rising and falling thresholds to stabilize slow or noisy signals. This guide covers hysteresis, 74HC14 and 74HCT14 selection, comparator calculations, RC oscillators and p…
Counterfeit components can hide behind convincing markings and passing basic function tests. This engineering reference covers source traceability, external inspection, X-ray, XRF, electrical testing, …
A practical engineering and sourcing framework covering lifecycle verification, lifetime-buy calculations, replacement qualification, supplier checks and counterfeit-risk controls.
TTL and CMOS logic families differ in thresholds, loading, output drive, power and timing. This engineering guide compares 74HC and 74HCT, calculates noise margins and checks 3.3 V/5 V compatibility.
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …