Melexis Technologies NV MLX90412KLW-BAA-022-SP
- Part No.:
- MLX90412KLW-BAA-022-SP
- Manufacturer:
- Melexis Technologies NV
- Category:
- Motor Drivers, Controllers
- Package:
- 10-DFN Exposed Pad
- Datasheet:
-
MLX90412KLW-BAA-022-SP.pdf
- Description:
- IC FAN DRIVER 20V 2.2A 10DFN
- Quantity:
- Payment:

- Shipping:

Inventory:3,447
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MLX90412KLW-BAA-022-SP from Melexis is a single-coil brushless DC fan and pump driver IC with integrated high-sensitivity Hall-effect sensor, 2.2 A motor current limit, closed-loop speed control (±1.5% accuracy), adaptive low-noise commutation, and I²C programmability - designed for smart 12 V/24 V cooling and fluid-handling systems up to 35 W, including robotic vacuum cleaners and condenser dryer drain pumps.
For engineers reviewing the MLX90412KLW-BAA-022-SP datasheet, pinout, applications, or equivalent options, key selection considerations include its DFN10 3×3 mm exposed-pad package, programmable locked rotor protection, open/closed-loop PWM control interface, and UL/VDE/CE readiness for consumer-grade thermal management designs.
Technical Context
The MLX90412KLW-BAA-022-SP implements sensor-based commutation using an on-chip Hall-effect sensor and supports both open-loop and closed-loop speed regulation via external PWM input or internal I²C command. Its adaptive commutation algorithm dynamically adjusts timing across the full speed range to maximize efficiency and minimize acoustic noise.
Protection features include programmable locked rotor detection, overvoltage protection (OVP), overcurrent protection (OCP), current limiting, thermal shutdown (TSD), and diagnostic FG/RD output - all implemented in silicon without external components. The device operates from 3.5 V to 32 V and withstands transients up to 40 V.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Supply Voltage Range | 3.5 V to 32 V - supports 12 V/24 V industrial and consumer power rails with 40 V transient robustness |
| Max Motor Current | 2.2 A - enables safe driving of up to 35 W BLDC loads without external current sensing |
| Speed Control Accuracy | ±1.5% in closed-loop mode - eliminates need for mechanical calibration in fan/pump tooling |
| Package | DFN10 3×3 mm with wettable flanks - 9 mm² footprint, <1 mm height, JEDEC-qualified for automated optical inspection |
| Interface | I²C + PWM - allows end-of-line programming and real-time speed setpoint adjustment |
| Protections | Programmable LRP/OVP, TSD, OCP, CL - reduces BOM count and improves system-level reliability |
Pinout & Package
MLX90412KLW-BAA-022-SP uses a 10-pin DFN package (3 mm × 3 mm, 0.75 mm pitch) with exposed thermal pad. Pin 1 is marked by a dot; pins are numbered counter-clockwise starting from top-left corner.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| VDD | Power supply input | Connects to 3.5–32 V rail; internal regulator powers logic and sensor |
| GND | Ground reference | Common return for power, logic, and motor phases |
| OUTP | High-side output | Drives one motor phase; rated for 2.2 A continuous, 3.5 A peak |
| OUTN | Low-side output | Drives complementary motor phase; matched to OUTP for balanced commutation |
| HALL | Hall sensor output | Internal analog Hall signal - used for sensor-based commutation timing |
| FG/RD | Open-drain diagnostic | Configurable as tachometer (FG) or rotor lock flag (RD); pull-up required |
| PWM | Speed control input | Accepts 1–100 kHz PWM signal for open/closed-loop speed setting |
| SCL / SDA | I²C interface | Enable configuration of protections, commutation mode, and diagnostics |
| EN | Enable input | Active-high logic input; disables outputs and enters standby mode when low |
| EPAD | Thermal pad | Must be soldered to PCB copper pour for thermal dissipation and EMI reduction |
Key Features
| Feature | Design Value |
|---|---|
| All-in-one BLDC driver + Hall sensor | Eliminates need for external position sensor and gate drivers - reduces component count by ≥4 devices |
| Adaptive commutation | Dynamically optimizes switching timing across 0–100% speed range to maintain >85% efficiency and <35 dB(A) acoustic noise |
| Programmable locked rotor protection | Customizable timeout and current threshold prevent coil burnout during stall conditions in pump startup or clogged filter scenarios |
| I²C + PWM dual control interface | Enables factory programming of parameters and runtime speed adjustment without hardware changes |
| UL/VDE/CE-ready certification support | Meets creepage/clearance, thermal, and fault-response requirements for Class II consumer appliances |
Applications
| Robotic Vacuum Cleaner | Condenser Dryer Drain Pump |
|---|---|
Use Scenario: Continuous suction motor operation under variable dust-load and battery voltage drop (24–29 V). IC Role / Device Role / Timing Role: Single-coil BLDC driver with closed-loop speed regulation and stall detection. Use Value: Maintains constant airflow despite voltage sag and load variation; programmable LRP prevents motor damage during brush entanglement. | Use Scenario: Intermittent high-torque pumping in compact condenser dryers with 28 V supply and space-constrained PCB layout. IC Role / Device Role / Timing Role: Integrated fan/pump driver with adaptive commutation and thermal-aware shutdown. Use Value: Delivers 2.2 A peak current in <1 mm height package; TSD and OVP ensure compliance with IEC 60335-1 safety standards. |
| Smart Window Air Conditioner | Toilet Flush Pump |
Use Scenario: Indoor unit blower requiring quiet operation (<38 dB(A)) and precise airflow control across ambient temperatures from 15 °C to 45 °C. IC Role / Device Role / Timing Role: Low-noise BLDC driver with closed-loop speed feedback and I²C-configurable commutation profile. Use Value: Adaptive commutation reduces acoustic noise by ≥8 dB vs fixed-timing drivers; ±1.5% speed accuracy ensures consistent thermal performance. | Use Scenario: Compact, high-reliability flush pump operating from 24 V bus in residential smart bathroom systems with frequent short-cycle duty. IC Role / Device Role / Timing Role: Programmable pump driver with FG output for flow verification and OCP-triggered retry logic. Use Value: FG/RD pin provides real-time rotor status to MCU; programmable OCP avoids nuisance trips during cold-start inrush. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar single-coil BLDC fan and pump driver applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| DRV10983ZRTJR | Requires external Hall sensor; no integrated sensor or I²C interface; fixed commutation timing | Lacks closed-loop speed accuracy and programmable diagnostics; suited for cost-sensitive, lower-noise-tolerance fans | Choose DRV10983ZRTJR only if sensor integration and field-programmability are not required |
| MP6532GQ-Z | Supports only open-loop control; no closed-loop speed regulation or FG/RD diagnostics; 1.8 A max current | Targeted at basic 12 V fans without acoustic or reliability requirements; no LRP or OVP programming | MP6532GQ-Z fits simple cooling needs but cannot replace MLX90412KLW-BAA-022-SP in closed-loop or safety-critical pump applications |
Compared with DRV10983ZRTJR and MP6532GQ-Z, the MLX90412KLW-BAA-022-SP delivers unique value through on-die Hall sensing, ±1.5% closed-loop speed control, and I²C-configurable protections - enabling faster time-to-market for smart appliance developers needing certified, low-noise, and field-adaptable motor control.
Availability
MLX90412KLW-BAA-022-SP is available at Aetrix Electronics and suitable for robotic vacuum cleaners, condenser dryer drain pumps, and smart window air conditioners requiring stable component supply, long-term lifecycle support, and certified motor control functionality.
Supply support for MLX90412KLW-BAA-022-SP includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Melexis is a Belgian semiconductor company specializing in sensor and driver ICs for automotive, industrial, and consumer applications, with core expertise in magnetic sensing and motor control.
The MLX90412-K product line delivers fully integrated, programmable BLDC drivers for smart thermal and fluid-handling systems - targeting noise-sensitive, safety-compliant, and rapidly configurable consumer appliances.
FAQ
What is the maximum continuous motor current supported by the MLX90412KLW-BAA-022-SP?
The MLX90412KLW-BAA-022-SP supports up to 2.2 A continuous motor current, enabling safe operation of BLDC loads up to 35 W at 24 V. This rating assumes proper PCB thermal design with the exposed pad soldered to a ≥200 mm² copper pour. Peak current capability reaches 3.5 A for short durations under defined thermal conditions.
Does the MLX90412KLW-BAA-022-SP require an external Hall-effect sensor?
No, the MLX90412KLW-BAA-022-SP integrates a high-sensitivity Hall-effect sensor on-die, eliminating the need for external position sensing components. This internal sensor provides the rotor position feedback required for sensor-based commutation and closed-loop speed control - a key differentiator from competing drivers like the DRV10983ZRTJR.
Can the MLX90412KLW-BAA-022-SP operate in both open-loop and closed-loop speed control modes?
Yes, the MLX90412KLW-BAA-022-SP supports both modes: open-loop via PWM input (1–100 kHz), and closed-loop using internal speed feedback with ±1.5% accuracy. Closed-loop mode reduces design effort for fan/pump tooling adjustments and improves response to end-customer performance requests without hardware changes.
What certifications does the MLX90412KLW-BAA-022-SP support out of the box?
The MLX90412KLW-BAA-022-SP is UL/VDE/CE ready, meeting critical safety requirements for consumer appliances including creepage/clearance distances, thermal shutdown behavior, and fault response timing. Its JEDEC-qualified DFN10 package further supports automated optical inspection and high-yield manufacturing in certified production lines.
How is diagnostic feedback provided by the MLX90412KLW-BAA-022-SP?
The MLX90412KLW-BAA-022-SP provides diagnostics via its open-drain FG/RD pin, configurable as either a tachometer output (FG) or rotor lock flag (RD). Configuration is done via I²C, allowing dynamic reassignment during system operation - for example, switching from speed monitoring to stall detection during pump priming sequences.
MLX90412KLW-BAA-022-SP Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Melexis Technologies NV
- Series:
- -
- Package/Case:
- 10-DFN Exposed Pad
- Packaging:
- Tube
- Product Status:
- Not For New Designs
- Motor Type - Stepper:
- -
- Motor Type - AC, DC:
- -
- Function:
- Driver - Fully Integrated, Control and Power Stage
- Output Configuration:
- -
- Interface:
- I2C, PWM
- Technology:
- -
- Step Resolution:
- -
- Applications:
- Fan Motor Driver
- Current - Output:
- 2.2A
- Voltage - Supply:
- 3.5V ~ 32V
- Voltage - Load:
- -
- Operating Temperature:
- -
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Surface Mount, Wettable Flank
- Supplier Device Package:
- 10-DFN (3x3)
MLX90412KLW-BAA-022-SP FAQ
1.How can I place an order for MLX90412KLW-BAA-022-SP through Aetrix?
Please submit a Request for Quotation (RFQ) for MLX90412KLW-BAA-022-SP on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MLX90412KLW-BAA-022-SP reliable?
The price and inventory of MLX90412KLW-BAA-022-SP are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MLX90412KLW-BAA-022-SP is usually 5 days.
3.What payment methods are accepted for MLX90412KLW-BAA-022-SP?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MLX90412KLW-BAA-022-SP transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MLX90412KLW-BAA-022-SP?
MLX90412KLW-BAA-022-SP orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MLX90412KLW-BAA-022-SP order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MLX90412KLW-BAA-022-SP?
For technical support, including MLX90412KLW-BAA-022-SP datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MLX90412KLW-BAA-022-SP requirements.
6.How does Aetrix verify that MLX90412KLW-BAA-022-SP is sourced from the original manufacturer or authorized distributors?
All MLX90412KLW-BAA-022-SP products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MLX90412KLW-BAA-022-SP meets industry standards.
7.What is the process for return or replacement of MLX90412KLW-BAA-022-SP?
All MLX90412KLW-BAA-022-SP units undergo pre-shipment inspection (PSI). If there is an issue with MLX90412KLW-BAA-022-SP, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MLX90412KLW-BAA-022-SP part is unused and in its original packaging.
Return procedure for MLX90412KLW-BAA-022-SP:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MLX90412KLW-BAA-022-SP Tags
-
DRV2603RUNR
Texas Instruments

-
DRV8837CDSGR
Texas Instruments

-
DRV8837DSGR
Texas Instruments

-
DRV8838DSGR
Texas Instruments

-
DRV8839DSSR
Texas Instruments

-
EMC2301-1-ACZL-TR
Microchip Technology

-
DRV8231ADSGR
Texas Instruments

-
EMC2302-2-AIZL-TR
Microchip Technology

-
DRV8800PWPR
Texas Instruments

-
DRV8835DSSR
Texas Instruments

-
EMC2303-1-KP-TR
Microchip Technology

-
DRV8876PWPR
Texas Instruments
Tech Hub
Comparator circuit design covering voltage thresholds, input limits, open-collector outputs, LM393 wiring, op-amp differences, hysteresis, timing, window detection and practical fault diagnosis.
Schmitt triggers use separate rising and falling thresholds to stabilize slow or noisy signals. This guide covers hysteresis, 74HC14 and 74HCT14 selection, comparator calculations, RC oscillators and p…
Counterfeit components can hide behind convincing markings and passing basic function tests. This engineering reference covers source traceability, external inspection, X-ray, XRF, electrical testing, …
A practical engineering and sourcing framework covering lifecycle verification, lifetime-buy calculations, replacement qualification, supplier checks and counterfeit-risk controls.
TTL and CMOS logic families differ in thresholds, loading, output drive, power and timing. This engineering guide compares 74HC and 74HCT, calculates noise margins and checks 3.3 V/5 V compatibility.
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …