Melexis Technologies NV MLX90422GGO-ADD-030-TU
- Part No.:
- MLX90422GGO-ADD-030-TU
- Manufacturer:
- Melexis Technologies NV
- Category:
- Angle, Linear Position Measuring
- Package:
- 16-TSSOP (0.173", 4.40mm Width)
- Datasheet:
-
MLX90422GGO-ADD-030-TU.pdf
- Description:
- SENSOR MAG POS RATIO/PWM 16TSSOP
- Quantity:
- Payment:

- Shipping:

Inventory:3,358
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MLX90422GGO-ADD-030-TU from Melexis is a dual-die Triaxis® Hall-based absolute rotary position sensor IC in TSSOP-16 package, delivering SENT output per SAE J2716 APR2016, operating from −40 °C to +160 °C, with ISO 26262 ASIL B safety certification and AEC-Q100 Grade 0 qualification - used in automotive throttle and steering wheel position sensing.
For engineers reviewing the MLX90422GGO-ADD-030-TU datasheet, pinout, applications, or equivalent options, key selection factors include dual-die redundancy architecture, SENT frame timing (861–905 μs), programmable 17-point linearization, ±126 mT Z-axis magnetic sensitivity, and high-temperature operation up to +160 °C.
Technical Context
The MLX90422GGO-ADD-030-TU integrates two independent Triaxis® Hall front ends, each with dedicated VDD/VSS/VDEC pins and separate SENT outputs (OUT1/OUT2), enabling full functional redundancy for safety-critical applications. Its DSP performs real-time 3D magnetic vector processing (Bx, By, Bz) to compute absolute angular position without external magnets or gears.
It supports both synchronous (fixed-frame) and asynchronous (variable-frame) SENT modes, with configurable diagnostics including broken-wire detection on VDD/VSS, CRC error reporting, and programmable field thresholds (BTH_LOW: 2–30 mT; BTH_HIGH: 70–126 mT). The device uses internal 24 MHz main clock with ±5% tolerance and 3 μs fixed tick time.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Supply Voltage | 4.5–5.5 V - stable operation across automotive battery transients; dual-die version draws ≤17 mA total. |
| Output Protocol | SENT per SAE J2716 APR2016 - supports A.3 (H.4) format with pause pulse, 287-tick frames (861–905 μs). |
| Operating Temp | −40 °C to +160 °C - qualified for under-hood automotive use; junction limit +175 °C. |
| Magnetic Sensitivity | Bz up to ±126 mT - enables robust sensing with small, low-cost magnets in rotary configurations. |
| Accuracy | ±0.5° typical angular error - achieved via on-chip 17-point programmable linearization and IMC-enhanced signal conditioning. |
| Safety Certification | ISO 26262 ASIL B SEooC - includes watchdog timers, memory ECC, and diagnostic cycle times (DCTANA = 10.4 ms). |
| Package | TSSOP-16 (GO) - dual-die layout with isolation resistance ≥4 MΩ between dies for fault containment. |
Pinout & Package
TSSOP-16 (GO) package provides full redundancy: two independent sensor dies sharing no analog or digital resources except PCB ground plane. Requires separate decoupling capacitors per die (VDEC1/VDEC2) and isolated supply routing for highest fault tolerance.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1, 9 | VDEC1 / VDEC2 | Dedicated decoupling pins per die - must be connected to local 100 nF ceramic caps near each VDD pin. |
| 2, 10 | VSS1 / VSS2 | Independent ground returns - recommended to route separately to minimize cross-die noise coupling. |
| 3, 11 | VDD1 / VDD2 | Independent power inputs - enables supply monitoring per die and fault isolation during overvoltage events. |
| 6, 15 | OUT2 / OUT1 | Separate open-drain SENT outputs - allows dual-channel validation or fail-safe voting logic in host ECU. |
| 4, 5, 12, 13, 7, 8, 14, 16 | Test11 / Test22 / Test12 / Test21 / N.C. | Factory test pins - internally grounded in application mode; connect to PCB ground for EMC compliance. |
Key Features
| Feature | Design Value |
|---|---|
| Dual-die redundancy | Two physically independent sensor dies in one TSSOP-16 package - eliminates single-point failure risk in ASIL B systems. |
| Triaxis® 3D sensing | Simultaneous measurement of Bx, By, Bz - enables absolute angle calculation from magnet rotation without mechanical stops or calibration. |
| Programmable linearization | Up to 17-point user-defined transfer curve - compensates for non-ideal magnet fields and mechanical tolerances in production assemblies. |
| SENT diagnostics | Embedded CRC, broken-wire detection (VDD/VSS), and configurable field thresholds - reduces need for external diagnostic circuitry. |
| High-temp operation | Validated operation at +160 °C ambient - supports placement near engines, transmissions, and exhaust components. |
Applications
| Throttle Position Sensing | Steering Wheel Angle Sensing |
|---|---|
|
Use Scenario: Real-time detection of accelerator pedal rotation in gasoline/diesel powertrains with fail-operational requirements. IC Role / Device Role / Timing Role: Primary angular position sensor providing SENT output to engine control unit with <905 μs frame period and ASIL B-compliant diagnostics. Use Value: Dual-die redundancy ensures continuous operation even if one die fails, meeting OEM functional safety targets without system-level duplication. |
Use Scenario: Contactless measurement of steering column rotation for EPS assist torque calculation and ADAS lane-keeping functions. IC Role / Device Role / Timing Role: Absolute rotary sensor delivering synchronized SENT frames with <2.03 ms latency (Filter 2) and programmable 0.5° accuracy. Use Value: Eliminates potentiometer wear and contact bounce, enabling >10M-cycle lifetime and consistent performance across temperature extremes. |
| Pedal Position Sensing | Transmission Gear Selector Sensing |
|
Use Scenario: Detection of brake or clutch pedal travel in vehicles with electronic braking or automated manual transmissions. IC Role / Device Role / Timing Role: Linear-to-rotary position converter using magnet-on-shaft configuration, outputting SENT frames with user-defined 17-point transfer curve. Use Value: Programmable measurement range and linearization allow one hardware design to support multiple pedal stroke lengths across vehicle platforms. |
Use Scenario: Gear position feedback in automatic or dual-clutch transmissions where physical detents are replaced by magnetic encoding. IC Role / Device Role / Timing Role: Redundant absolute position sensor interfacing with transmission control module via SENT, supporting safe default states on fault detection. Use Value: Dual-die architecture enables voting logic to distinguish true gear misalignment from transient sensor faults, reducing false shift inhibition. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar absolute rotary position sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MLX90421GGO-ADD-030-TU | Single-die variant in same TSSOP-16 package - lacks dual-die redundancy and inter-die isolation. | Not suitable for ASIL B systems requiring hardware redundancy; lower cost for non-safety-critical throttle sensors. | Select when functional safety certification is not required and BOM cost reduction is prioritized over fault tolerance. |
| AMS AS5055A-BQFT | Single-die Hall-based encoder with SPI/I²C output - no SENT support, no ASIL B certification, max temp +125 °C. | Limited to non-automotive industrial position sensing; requires external microcontroller for SENT conversion. | Choose only for cost-sensitive, non-automotive applications where SENT interface and high-temp operation are unnecessary. |
Compared with MLX90422GGO-ADD-030-TU, the MLX90421GGO-ADD-030-TU reduces system-level safety mechanisms but increases risk of undetected latent faults, while the AMS AS5055A-BQFT requires additional signal conditioning and fails to meet automotive thermal or protocol requirements - making MLX90422GGO-ADD-030-TU the only drop-in solution for ASIL B rotary sensing at +160 °C.
Availability
MLX90422GGO-ADD-030-TU is available at Aetrix Electronics and suitable for automotive throttle position sensing, steering angle measurement, and transmission gear selector applications requiring stable component supply, long-term lifecycle assurance, and traceable sourcing for Tier 1 suppliers.
Supply support for MLX90422GGO-ADD-030-TU includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Melexis is a Belgian semiconductor company specializing in magnetic sensing, infrared thermometry, and automotive ICs, with design centers in Europe and manufacturing partnerships in Asia.
The MLX90422 product line delivers Triaxis®-based absolute position sensing for ASIL B automotive systems, targeting applications where contactless, high-accuracy, and high-temperature operation are mandatory - such as drive-by-wire and x-by-wire subsystems.
FAQ
What is the maximum ambient temperature rating for MLX90422GGO-ADD-030-TU?
The MLX90422GGO-ADD-030-TU is rated for continuous operation from −40 °C to +160 °C ambient temperature, with junction temperature limited to +175 °C. It supports short-duration exposure up to +180 °C in SMP/DMP packages, but the TSSOP-16 (GO) variant is validated only to +160 °C per AEC-Q100 Grade 0 specification. This makes MLX90422GGO-ADD-030-TU suitable for under-hood automotive locations including throttle bodies and transmission housings.
Does MLX90422GGO-ADD-030-TU support both synchronous and asynchronous SENT modes?
Yes, MLX90422GGO-ADD-030-TU supports both modes. In default factory configuration, it operates in synchronous SENT mode with fixed 287-tick frames (861–905 μs), where angle acquisition is aligned to frame start. It can be reprogrammed to asynchronous mode with variable frame length (up to 270 ticks), enabling lower average latency (as low as 0.83 ms) at the cost of jitter. Both modes comply with SAE J2716 APR2016 and retain full diagnostic coverage - a key capability of MLX90422GGO-ADD-030-TU.
How does the dual-die architecture of MLX90422GGO-ADD-030-TU improve functional safety?
The MLX90422GGO-ADD-030-TU implements physically independent sensor dies with separate power, ground, decoupling, and output pins - achieving ≥4 MΩ isolation resistance between dies. This architecture enables cross-checking of SENT outputs, detection of die-specific faults (e.g., broken wire, magnetic saturation), and continued operation after single-die failure. As a result, MLX90422GGO-ADD-030-TU meets ISO 26262 ASIL B as a Safety Element out of Context, eliminating need for external redundancy in the ECU.
Can MLX90422GGO-ADD-030-TU be programmed for linear position sensing?
Yes, MLX90422GGO-ADD-030-TU supports both angular rotary and linear position modes via end-user programming. In linear mode, it calculates position from magnetic field gradients along one axis (e.g., Bx or By), using the same Triaxis® front end and 17-point programmable transfer characteristic. The device's magnetic specification confirms usable flux density norms down to 10 mT in X-Y mode - enabling compact, low-cost linear implementations such as ride height or suspension travel sensors without modifying MLX90422GGO-ADD-030-TU hardware.
What are the key electrical requirements for the SENT output of MLX90422GGO-ADD-030-TU?
The MLX90422GGO-ADD-030-TU SENT outputs (OUT1/OUT2) are open-drain with 0.5 V low-state voltage at 0.52 mA load and 4.1 V high-state voltage at 0.10 mA load. It requires an external pull-up resistor (10–55 kΩ) to Vext = VDD, and supports SENT frame timing with 3 μs fixed tick time, 287-tick frames, and pause pulses. These parameters ensure compatibility with standard automotive SENT receivers and eliminate need for level-shifting or timing recalibration - a core design feature of MLX90422GGO-ADD-030-TU.
MLX90422GGO-ADD-030-TU Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Melexis Technologies NV
- Package/Case:
- 16-TSSOP (0.173", 4.40mm Width)
- Series:
- -
- Packaging:
- Tube
- Product Status:
- Active
- Programmable:
- -
- For Measuring:
- Linear, Rotary Position
- Technology:
- Hall Effect
- Rotation Angle - Electrical, Mechanical:
- 0° ~ 360°, Continuous
- Linear Range:
- -
- Output:
- SENT
- Output Signal:
- Programmable
- Actuator Type:
- External Magnet, Not Included
- Linearity:
- ±1°
- Resistance:
- -
- Resistance Tolerance:
- -
- Voltage - Supply:
- 4.5V ~ 5.5V
- Mounting Type:
- Surface Mount
- Termination Style:
- Gull Wing
- Operating Temperature:
- -40°C ~ 160°C
- Grade:
- -
- Qualification:
- -
- Supplier Device Package:
- 16-TSSOP
MLX90422GGO-ADD-030-TU FAQ
1.How can I place an order for MLX90422GGO-ADD-030-TU through Aetrix?
Please submit a Request for Quotation (RFQ) for MLX90422GGO-ADD-030-TU on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MLX90422GGO-ADD-030-TU reliable?
The price and inventory of MLX90422GGO-ADD-030-TU are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MLX90422GGO-ADD-030-TU is usually 5 days.
3.What payment methods are accepted for MLX90422GGO-ADD-030-TU?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MLX90422GGO-ADD-030-TU transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MLX90422GGO-ADD-030-TU?
MLX90422GGO-ADD-030-TU orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MLX90422GGO-ADD-030-TU order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MLX90422GGO-ADD-030-TU?
For technical support, including MLX90422GGO-ADD-030-TU datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MLX90422GGO-ADD-030-TU requirements.
6.How does Aetrix verify that MLX90422GGO-ADD-030-TU is sourced from the original manufacturer or authorized distributors?
All MLX90422GGO-ADD-030-TU products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MLX90422GGO-ADD-030-TU meets industry standards.
7.What is the process for return or replacement of MLX90422GGO-ADD-030-TU?
All MLX90422GGO-ADD-030-TU units undergo pre-shipment inspection (PSI). If there is an issue with MLX90422GGO-ADD-030-TU, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MLX90422GGO-ADD-030-TU part is unused and in its original packaging.
Return procedure for MLX90422GGO-ADD-030-TU:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MLX90422GGO-ADD-030-TU Tags

-
TLV493DA1B6HTSA2
Infineon Technologies
-
EVW-AE4001B14
Panasonic Electronic Components

-
3382G-1-103G
Bourns Inc.

-
TLE5501E0001XUMA1
Infineon Technologies

-
HAL830UT-A
TDK-Micronas GmbH

-
TLE5009E1000FUMA1
Infineon Technologies

-
TLE5501E0002XUMA1
Infineon Technologies

-
HAL3725DJ-A
TDK-Micronas GmbH

-
HAL3727DJ-A
TDK-Micronas GmbH
-
HMC1501-TR
Honeywell Aerospace
-
HMC1512-TR
Honeywell Aerospace

-
AAS33001LLEATR-5
Allegro MicroSystems
Tech Hub
Comparator circuit design covering voltage thresholds, input limits, open-collector outputs, LM393 wiring, op-amp differences, hysteresis, timing, window detection and practical fault diagnosis.
Schmitt triggers use separate rising and falling thresholds to stabilize slow or noisy signals. This guide covers hysteresis, 74HC14 and 74HCT14 selection, comparator calculations, RC oscillators and p…
Counterfeit components can hide behind convincing markings and passing basic function tests. This engineering reference covers source traceability, external inspection, X-ray, XRF, electrical testing, …
A practical engineering and sourcing framework covering lifecycle verification, lifetime-buy calculations, replacement qualification, supplier checks and counterfeit-risk controls.
TTL and CMOS logic families differ in thresholds, loading, output drive, power and timing. This engineering guide compares 74HC and 74HCT, calculates noise margins and checks 3.3 V/5 V compatibility.
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …