Melexis Technologies NV MLX90614ESF-BBA-000-SP
- Part No.:
- MLX90614ESF-BBA-000-SP
- Manufacturer:
- Melexis Technologies NV
- Category:
- Analog and Digital Output
- Package:
- TO-39-4 Metal Can
- Datasheet:
-
MLX90614ESF-BBA-000-SP.pdf
- Description:
- SENSOR DGTL -40C-85C TO39
- Quantity:
- Payment:

- Shipping:

Inventory:3,744
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MLX90614ESF-BBA-000-SP from Melexis is a factory-calibrated, single-zone infrared thermometer IC in TO-39 package, delivering ±0.5°C accuracy (0°C to +50°C), -70°C to +380°C object temperature range, and SMBus/PWM dual-output interface for non-contact thermal sensing in automotive HVAC and medical-grade monitoring systems.
For engineers reviewing the MLX90614ESF-BBA-000-SP datasheet, pinout, applications, or equivalent options, key selection factors include its 3.0V supply operation, -40°C to +85°C ambient rating, integrated optical long-wave pass filter (5.5–14 µm), 10-bit PWM output with 0.14°C resolution, and thermal gradient compensation capability in xCx variants.
Technical Context
The MLX90614ESF-BBA-000-SP integrates a thermopile detector and signal-conditioning ASSP in one TO-39 can, using a low-noise chopper amplifier, 17-bit ADC, and DSP-based computation to derive ambient (Ta) and object (To) temperatures. Its internal FIR/IIR filtering enables configurable refresh rates and noise performance.
It operates as an SMBus slave device (default address 0x5A) with programmable EEPROM registers for emissivity (0.1–1.0), PWM range, and thermal relay thresholds. The BBA variant uses 3.0V supply, supports sleep mode (2–6 µA), and excludes zener protection on SCL - distinguishing it from Axx versions.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Supply Voltage | 2.6 V to 3.6 V - compatible with battery-powered or low-voltage regulated systems |
| Object Temp Range | -70°C to +380°C - enables industrial hot-spot detection and human body measurement |
| Ambient Temp Range | -40°C to +85°C - qualified for under-hood automotive and residential HVAC environments |
| Accuracy (Ta/To) | ±0.5°C at 0°C to +50°C - factory-calibrated and traceable, no user recalibration required |
| Output Interface | SMBus (10–100 kHz) + configurable 10-bit PWM - dual-mode flexibility for microcontroller integration or analog-like feedback |
| Optical Filter | 5.5 µm to 14 µm long-wave pass - rejects visible/NIR light, ensuring immunity to sunlight and incandescent sources |
| Power Consumption | 1.3–2.5 mA active; 2–6 µA sleep - extends battery life in portable thermal monitors |
Pinout & Package
MLX90614ESF-BBA-000-SP is housed in an industry-standard 4-pin TO-39 metal can package with hermetically sealed IR window and internal optical filter. Pin 1 (SCL/Vz) functions as SMBus clock input only (no zener - Bxx variant); Pin 2 (SDA/PWM) serves as bidirectional data line or PWM output; Pins 3 and 4 are dedicated to VDD and VSS respectively.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 | SCL input | SMBus serial clock - no internal zener diode (Bxx variant), requires external pull-up |
| 2 | SDA I/O or PWM output | Configurable bidirectional data line or open-drain/push-pull thermal relay output |
| 3 | VDD supply | 3.0 V nominal input - supports 2.6–3.6 V operation; no high-voltage adaptation needed |
| 4 | VSS ground | Reference node for all signals - metal can must connect *only* to this pin per EMC/isothermal requirements |
Key Features
| Feature | Design Value |
|---|---|
| Factory calibration | Pre-programmed Ta/To coefficients and emissivity (ε = 1.0) stored in EEPROM - eliminates field calibration effort |
| Thermal gradient compensation | Internal measurement and correction for package ΔT - improves accuracy in non-isothermal mounting conditions |
| User-programmable PWM | Two EEPROM registers define custom To range (-20°C to +120°C default) - enables direct mapping to control logic without host MCU scaling |
| Thermal relay mode | PWM pin reconfigured as programmable threshold alert - implements hardware-level freeze/boil detection without firmware polling |
| Medical-grade accuracy option | ±0.2°C at 36°C–37°C (available in specific variants) - meets clinical thermometer requirements when configured |
Applications
| Automotive HVAC Control | Medical Thermometry |
|---|---|
Use Scenario: Non-contact cabin temperature sensing for automatic climate control in passenger vehicles. IC Role / Device Role / Timing Role: Ambient temperature (Ta) measurement via internal thermistor; provides real-time feedback to HVAC ECU. Use Value: Enables precise thermal comfort regulation without air duct sensors, reducing system latency and mechanical complexity. | Use Scenario: Contactless human body temperature screening in clinical triage or wearable health monitors. IC Role / Device Role / Timing Role: Object temperature (To) measurement of forehead or tympanic region with medical-grade accuracy configuration. Use Value: Delivers ±0.2°C accuracy near 37°C when calibrated per MLX90614 medical variant specs - supports FDA-cleared applications. |
| Industrial Moving-Part Monitoring | Smart Appliance Thermal Safety |
Use Scenario: Continuous surface temperature monitoring of conveyor belts, motors, or bearings in factory automation. IC Role / Device Role / Timing Role: High-dynamic-range To measurement (-70°C to +380°C) with 250 ms output validity after power-on. Use Value: Detects abnormal heating before failure - enables predictive maintenance without physical contact or emissivity setup per target. | Use Scenario: Overheat protection in microwave ovens, coffee makers, or 3D printer hot ends. IC Role / Device Role / Timing Role: Thermal relay mode triggers hardware interrupt at user-defined To threshold (e.g., >120°C). Use Value: Provides fail-safe shutdown independent of main controller - eliminates software crash risk during thermal fault events. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar non-contact IR temperature sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MLX90614ESF-BCI-000-SP | Same TO-39 package and 3.0V supply, but features uncoated silicon lens (no long-wave pass filter) - wider spectral response (1–20 µm) | Lacks sunlight/ambient immunity - suitable only for controlled indoor environments with known emissivity targets | Select only when measuring low-emissivity metals or requiring extended spectral sensitivity beyond 14 µm |
| AMG8833 | 8×8 thermal array (64 pixels) vs. single-point MLX90614; I²C interface only; no PWM; lower accuracy (±2.5°C) | Enables thermal imaging and motion detection - not a drop-in replacement for spot temperature measurement | Choose for presence detection or spatial temperature profiling; avoid when single-point precision or hardware alerting is required |
Compared with MLX90614ESF-BBA-000-SP, the BCI variant trades ambient immunity for broader spectral coverage, while the AMG8833 shifts from precision spot sensing to low-resolution thermal imaging - neither offers pin compatibility or identical SMBus register mapping.
Availability
MLX90614ESF-BBA-000-SP is available at Aetrix Electronics and suitable for automotive HVAC control, medical thermometry, and industrial moving-part monitoring requiring stable component supply, long-term lifecycle support, and traceable sourcing.
Supply support for MLX90614ESF-BBA-000-SP includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Melexis is a Belgian semiconductor company specializing in sensor and wireless RF ICs, with core expertise in magnetic, infrared, and pressure sensing technologies for automotive and industrial markets.
The MLX90614 product line was designed specifically for high-accuracy, low-power, non-contact temperature measurement in space-constrained and thermally dynamic environments - targeting automotive, healthcare, and smart appliance applications.
FAQ
What is the operating voltage range for MLX90614ESF-BBA-000-SP?
The MLX90614ESF-BBA-000-SP operates from 2.6 V to 3.6 V, making it compatible with standard 3.0 V systems including battery-powered devices. It does not support 5 V or higher supply voltages - unlike the Axx series - and lacks the internal zener diode on the SCL pin. This voltage range ensures low-power operation while maintaining full functionality of SMBus communication and PWM output.
Does MLX90614ESF-BBA-000-SP support sleep mode?
Yes, MLX90614ESF-BBA-000-SP supports sleep mode with typical current consumption of 2–6 µA, enabled via SMBus command. This feature is exclusive to Bxx and Dxx variants (3.0 V supply) and is unavailable in Axx (5.0 V) versions. Sleep mode reduces power between measurements without losing calibration or configuration settings stored in EEPROM, making it ideal for portable thermal monitors and energy-sensitive IoT nodes.
Can MLX90614ESF-BBA-000-SP measure human body temperature accurately?
Yes, MLX90614ESF-BBA-000-SP achieves ±0.5°C accuracy from 0°C to +50°C - sufficient for general wellness screening. For clinical-grade use, Melexis offers a medical-accuracy variant (±0.2°C at 36°C–37°C) with tighter calibration; the BBA-000-SP itself is not certified to that level but can be configured with appropriate optics, distance-to-target ratio, and emissivity (ε ≈ 0.97–0.98) to meet basic regulatory requirements in Class II medical devices.
How is emissivity adjusted on MLX90614ESF-BBA-000-SP?
Emissivity is adjusted by writing a 16-bit value to EEPROM address 0x04, where decimal 65535 corresponds to ε = 1.0. The formula is dec2hex[round(65535 × ε)], supporting values from 0.1 to 1.0. This write requires SMBus access and an erase cycle prior to programming. Once set, the value persists across power cycles and affects all subsequent To calculations - enabling accurate readings on non-blackbody surfaces like skin, plastic, or painted metal without external compensation.
What is the default communication interface for MLX90614ESF-BBA-000-SP at power-on?
The MLX90614ESF-BBA-000-SP defaults to SMBus mode at power-on reset (POR), with slave address 0x5A. The PWM function is disabled until explicitly enabled via EEPROM configuration register (address 0x02). This ensures reliable initialization in multi-device SMBus systems and avoids bus contention. The transition between interfaces is software-controlled and does not require hardware reconfiguration or pin strapping.
MLX90614ESF-BBA-000-SP Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Melexis Technologies NV
- Series:
- -
- Package/Case:
- TO-39-4 Metal Can
- Packaging:
- Bulk
- Product Status:
- Active
- Sensor Type:
- Digital, Infrared (IR)
- Sensing Temperature - Local:
- -40°C ~ 85°C
- Sensing Temperature - Remote:
- -70°C ~ 380°C (IR)
- Output Type:
- PWM, SMBus
- Voltage - Supply:
- 2.6V ~ 3.6V
- Resolution:
- 16 b
- Features:
- Sleep Mode
- Accuracy - Highest (Lowest):
- ±0.5°C (±4°C)
- Test Condition:
- 0°C ~ 60°C (120°C ~ 380°C)
- Operating Temperature:
- -40°C ~ 85°C
- Mounting Type:
- Through Hole
- Grade:
- -
- Qualification:
- -
- Supplier Device Package:
- TO-39
MLX90614ESF-BBA-000-SP FAQ
1.How can I place an order for MLX90614ESF-BBA-000-SP through Aetrix?
Please submit a Request for Quotation (RFQ) for MLX90614ESF-BBA-000-SP on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MLX90614ESF-BBA-000-SP reliable?
The price and inventory of MLX90614ESF-BBA-000-SP are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MLX90614ESF-BBA-000-SP is usually 5 days.
3.What payment methods are accepted for MLX90614ESF-BBA-000-SP?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MLX90614ESF-BBA-000-SP transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MLX90614ESF-BBA-000-SP?
MLX90614ESF-BBA-000-SP orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MLX90614ESF-BBA-000-SP order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MLX90614ESF-BBA-000-SP?
For technical support, including MLX90614ESF-BBA-000-SP datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MLX90614ESF-BBA-000-SP requirements.
6.How does Aetrix verify that MLX90614ESF-BBA-000-SP is sourced from the original manufacturer or authorized distributors?
All MLX90614ESF-BBA-000-SP products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MLX90614ESF-BBA-000-SP meets industry standards.
7.What is the process for return or replacement of MLX90614ESF-BBA-000-SP?
All MLX90614ESF-BBA-000-SP units undergo pre-shipment inspection (PSI). If there is an issue with MLX90614ESF-BBA-000-SP, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MLX90614ESF-BBA-000-SP part is unused and in its original packaging.
Return procedure for MLX90614ESF-BBA-000-SP:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MLX90614ESF-BBA-000-SP Tags

-
MCP9700T-E/TT
Microchip Technology

-
MCP9700T-E/LT
Microchip Technology

-
MCP9701T-E/TT
Microchip Technology

-
MCP9701T-E/LT
Microchip Technology

-
TMP235A4DBZR
Texas Instruments

-
MCP9700AT-E/TT
Microchip Technology

-
MCP9700AT-E/LT
Microchip Technology

-
MCP9701AT-E/LT
Microchip Technology

-
MCP9701AT-E/TT
Microchip Technology
,TO-226_straightlead.jpg)
-
LM335Z
STMicroelectronics
-
TMP1075NDRLR
Texas Instruments
-
TMP1075DGKR
Texas Instruments
Tech Hub
Comparator circuit design covering voltage thresholds, input limits, open-collector outputs, LM393 wiring, op-amp differences, hysteresis, timing, window detection and practical fault diagnosis.
Schmitt triggers use separate rising and falling thresholds to stabilize slow or noisy signals. This guide covers hysteresis, 74HC14 and 74HCT14 selection, comparator calculations, RC oscillators and p…
Counterfeit components can hide behind convincing markings and passing basic function tests. This engineering reference covers source traceability, external inspection, X-ray, XRF, electrical testing, …
A practical engineering and sourcing framework covering lifecycle verification, lifetime-buy calculations, replacement qualification, supplier checks and counterfeit-risk controls.
TTL and CMOS logic families differ in thresholds, loading, output drive, power and timing. This engineering guide compares 74HC and 74HCT, calculates noise margins and checks 3.3 V/5 V compatibility.
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …