Melexis Technologies NV MLX90614ESF-BCK-000-SP

Part No.:
MLX90614ESF-BCK-000-SP
Manufacturer:
Melexis Technologies NV
Category:
Analog and Digital Output
Package:
TO-39-4 Metal Can
Datasheet:
AetrixMLX90614ESF-BCK-000-SP.pdf
Description:
SENSOR TEMP 1PIXEL 3V 13FOV TO39
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:1,197

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

MLX90614ESF-BCK-000-SP from Melexis is a factory-calibrated, single-zone infrared thermometer IC in TO-39 metal can package, delivering ±0.5°C accuracy for ambient and object temperature over 0°C–50°C, 0.02°C measurement resolution in SMBus mode, and dual-output capability via SMBus or configurable 10-bit PWM - used in automotive blind-angle detection, thermal comfort control, and medical-grade body temperature sensing.

For engineers reviewing the MLX90614ESF-BCK-000-SP datasheet, pinout, applications, or equivalent options, key selection factors include its -40°C to +125°C operating ambient range, 3.0V supply compatibility, SMBus slave address 0x5A, integrated optical long-wave pass filter (5.5–14 µm), and thermal gradient compensation in Cx variants - critical for non-contact industrial and automotive thermal monitoring where isothermal mounting is constrained.

Technical Context

The MLX90614ESF-BCK-000-SP integrates a thermopile detector and signal-conditioning ASSP in one TO-39 package, using a low-noise chopper amplifier, 17-bit sigma-delta ADC, and programmable DSP to compute ambient (Ta) and object (To) temperatures with 0.01°C internal resolution. Its factory calibration covers Ta from -40°C to +125°C and To from -70°C to +380°C.

It supports two digital interfaces: SMBus (default power-on mode, 10–100 kHz, slave address 0x5A) and user-configurable 10-bit PWM (1.024 ms period, 0.14°C resolution in default -20°C to +120°C range). Sleep mode draws 2–6 µA and is enabled only on 3.0V Bxx variants like this part - not available on 5.0V Axx versions.

Key Specifications

ParameterValue and Actual Design Meaning
Supply Voltage2.6 V to 3.6 V - compatible with battery-powered or regulated 3.0 V systems; no external regulator needed.
Ambient Temp Range-40°C to +125°C - supports under-hood automotive and industrial environments without derating.
Object Temp Range-70°C to +380°C - enables wide-range non-contact monitoring of cold surfaces or hot machinery components.
Accuracy (Ta/To)±0.5°C at 0°C–50°C - guaranteed under isothermal conditions; enables clinical-grade thermal comfort control.
Output Resolution0.02°C (SMBus), 0.14°C (PWM default) - high-resolution digital output eliminates need for external ADC in precision applications.
SMBus Address0x5A (7-bit) - fixed slave address simplifies multi-sensor bus configuration with up to 127 devices.
Power Consumption1.3–2.5 mA active, 2–6 µA sleep - enables always-on thermal sensing in energy-constrained IoT and portable medical devices.

Pinout & Package

MLX90614ESF-BCK-000-SP uses the industry-standard 4-pin TO-39 metal can package (SF code), with hermetically sealed IR window and integrated long-wave pass optical filter (5.5–14 µm). The metal can must connect only to VSS for EMC and thermal stability; no other electrical connection is permitted.

Pin/TerminalCircuit RoleDesign Meaning
1: SCL / VzSMBus clock input / Zener clampAccepts 10–100 kHz SMBus clock; includes 5.7 V zener for overvoltage protection on Axx variants - not present on Bxx (3.0 V) variants like this part.
2: SDA / PWMBi-directional data I/O or PWM outputConfigurable as SMBus data line (open-drain) or 10-bit PWM output; defaults to SMBus after POR; supports thermal relay mode.
3: VDDPositive supply3.0 V nominal input (2.6–3.6 V range); powers internal regulator, DSP, and EEPROM; enables sleep mode entry.
4: VSSGround referencePrimary ground return; sole electrical connection allowed to TO-39 metal can - mandatory for thermal equilibrium and EMC compliance.

Key Features

FeatureDesign Value
Factory calibrationPre-programmed Ta/To coefficients stored in EEPROM eliminate field calibration; valid across full -40°C to +125°C ambient range.
Thermal gradient compensationInternal TGC (Temperature Gradient Compensation) logic reduces error from package thermal gradients - critical for compact enclosures with nearby heat sources.
User-programmable emissivityEmissivity value (0.1–1.0) stored in EEPROM address 0x04; allows accurate readings on non-blackbody surfaces (e.g., plastic, painted metal) without recalibration.
Configurable PWM outputTwo EEPROM registers (0x00–0x01) define custom To range and resolution; enables direct interface to microcontrollers lacking SMBus hardware.
Thermal relay functionPWM pin reconfigurable as open-drain thermal alert output; user-defined threshold triggers interrupt-capable thermostatic response without host CPU polling.

Applications

Automotive Blind-Angle DetectionMedical Body Temperature Screening

Use Scenario: Detecting presence and proximity of pedestrians or vehicles outside driver's field of view using passive IR sensing mounted in side mirrors or rear bumper.

IC Role / Device Role / Timing Role: Non-contact object temperature sensor measuring thermal signature of human bodies or vehicle exhausts within 35° FOV.

Use Value: Enables reliable detection at ambient extremes (-40°C to +125°C) with ±0.5°C accuracy - sufficient to distinguish human thermal mass from background clutter.

Use Scenario: Contactless forehead or tympanic temperature measurement in clinical triage, wearable health monitors, or kiosk-based fever screening.

IC Role / Device Role / Timing Role: High-resolution IR thermometer providing calibrated To output via SMBus for real-time display or cloud upload.

Use Value: 0.02°C resolution and medical-grade accuracy option support FDA-compliant thermal assessment without skin contact or consumables.

Industrial Moving-Part MonitoringSmart HVAC Thermal Comfort Control

Use Scenario: Continuous temperature surveillance of conveyor belts, motors, or bearings in manufacturing lines to prevent overheating failures.

IC Role / Device Role / Timing Role: Standalone IR sensor interfaced via PWM to PLC analog inputs or SMBus to embedded controller for predictive maintenance logging.

Use Value: -70°C to +380°C object range captures both cryogenic cooling and high-temp friction events; 250 ms output validity ensures timely fault response.

Use Scenario: Zone-based air conditioning control in vehicles or buildings using cabin/object temperature feedback to modulate blower speed and air mix.

IC Role / Device Role / Timing Role: Ambient (Ta) and surface (To) temperature sensor feeding closed-loop HVAC algorithm with thermal gradient compensation.

Use Value: Dual Ta/To outputs and TGC enable stable setpoint control even near dashboard heaters or sunlit windows - reducing occupant discomfort complaints by >30% in validation studies.

Equivalent & Alternatives

The following parts are listed as comparable options for similar non-contact IR temperature sensing applications.

Alternative PartTechnical DifferenceApplication DifferenceSelection Advice
MLX90614ESF-BCI-000-TUSame TO-39 package and 3.0 V supply, but features uncoated silicon lens (no long-wave pass filter); wider spectral response (1–14 µm) increases ambient light sensitivity.Preferred for indoor lab environments with controlled lighting; unsuitable for direct sunlight or automotive exterior use due to visible/NIR interference.Select when spectral flexibility outweighs ambient immunity; verify optical path shielding if used outdoors.
AMG88338×8 thermal array (64 pixels) vs. single-point MLX90614; I²C interface only; lower accuracy (±2.5°C); requires external optics and calibration.Used for thermal imaging (presence detection, gesture control), not precision spot measurement; needs host processor for pixel processing.Choose for spatial thermal mapping; avoid when single-point accuracy, SMBus compatibility, or drop-in replacement is required.

Compared with MLX90614ESF-BCK-000-SP, the BCJ variant trades optical filtering for broader spectrum response - limiting outdoor reliability - while the AMG8833 provides imaging capability at the cost of accuracy, interface simplicity, and calibration stability, making it unsuitable as a functional substitute in precision thermometry applications.

Availability

MLX90614ESF-BCK-000-SP is available at Aetrix Electronics and suitable for automotive blind-spot detection, medical-grade body temperature screening, and industrial moving-part thermal monitoring requiring stable component supply across extended temperature ranges and long product lifecycles.

Supply support for MLX90614ESF-BCK-000-SP includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

Melexis is a Belgian semiconductor company specializing in sensor and wireless RF ICs for automotive, industrial, and consumer markets, with ISO/TS 16949 certification and AEC-Q100 qualified products.

The MLX90614 product line delivers factory-calibrated IR thermometry for non-contact temperature measurement in space-constrained, thermally dynamic environments - designed specifically for automotive, healthcare, and smart building applications demanding high accuracy without system-level calibration.

FAQ

What is the operating voltage range for MLX90614ESF-BCK-000-SP?

The MLX90614ESF-BCK-000-SP operates from 2.6 V to 3.6 V, optimized for 3.0 V systems such as battery-powered medical devices or automotive body controllers. It does not support 5.0 V operation - that variant is designated MLX90614Axx. Exceeding 3.6 V may cause permanent damage per absolute maximum ratings.

Does MLX90614ESF-BCK-000-SP support sleep mode?

Yes, MLX90614ESF-BCK-000-SP supports sleep mode with 2–6 µA typical current draw, activated via SMBus command or hardware reset sequence. Sleep mode is exclusive to 3.0 V Bxx variants like this part and is not available on 5.0 V Axx versions. Wake-up time is 33 ms after SDA low pulse.

What is the field of view (FOV) of MLX90614ESF-BCK-000-SP?

The MLX90614ESF-BCK-000-SP has a 35° full-angle field of view, defined by its integrated silicon lens and TO-39 package geometry. This FOV is fixed per variant and cannot be altered mechanically or electrically. Accuracy specifications assume uniform target filling the entire FOV; partial coverage introduces measurement uncertainty.

Can MLX90614ESF-BCK-000-SP measure human body temperature accurately?

Yes, MLX90614ESF-BCK-000-SP achieves ±0.5°C accuracy in the 0°C–50°C range - covering human body temperature (35°C–42°C) - when mounted under isothermal conditions and with proper emissivity setting (ε ≈ 0.97–0.98 for skin). For regulatory-grade clinical use, Melexis offers a dedicated medical accuracy version (±0.2°C), but MLX90614ESF-BCK-000-SP meets general wellness screening requirements.

How is emissivity configured on MLX90614ESF-BCK-000-SP?

Emissivity is stored as a 16-bit value in EEPROM address 0x04, with factory default 0xFFFF (ε = 1.0). Users write scaled integer values using SMBus: ε = round(65535 × desired_emissivity), e.g., 0xF5AD for ε = 0.95. Write requires prior erase; no black-body recalibration is needed, and changes persist across power cycles.

MLX90614ESF-BCK-000-SP Specifications

Product attributes
Attribute value
Manufacturer:
Melexis Technologies NV
Series:
-
Package/Case:
TO-39-4 Metal Can
Packaging:
Tube
Product Status:
Active
Sensor Type:
Digital, Infrared (IR)
Sensing Temperature - Local:
-40°C ~ 85°C
Sensing Temperature - Remote:
-70°C ~ 380°C (IR)
Output Type:
PWM, SMBus
Voltage - Supply:
2.6V ~ 3.6V
Resolution:
0.02°C
Features:
Sleep Mode
Accuracy - Highest (Lowest):
±0.5°C
Test Condition:
0°C ~ 50°C
Operating Temperature:
-40°C ~ 85°C (TA)
Mounting Type:
Through Hole
Grade:
-
Qualification:
-
Supplier Device Package:
TO-39

MLX90614ESF-BCK-000-SP FAQ

1.How can I place an order for MLX90614ESF-BCK-000-SP through Aetrix?

Please submit a Request for Quotation (RFQ) for MLX90614ESF-BCK-000-SP on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for MLX90614ESF-BCK-000-SP reliable?

The price and inventory of MLX90614ESF-BCK-000-SP are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MLX90614ESF-BCK-000-SP is usually 5 days.

3.What payment methods are accepted for MLX90614ESF-BCK-000-SP?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MLX90614ESF-BCK-000-SP transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for MLX90614ESF-BCK-000-SP?

MLX90614ESF-BCK-000-SP orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your MLX90614ESF-BCK-000-SP order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for MLX90614ESF-BCK-000-SP?

For technical support, including MLX90614ESF-BCK-000-SP datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MLX90614ESF-BCK-000-SP requirements.

6.How does Aetrix verify that MLX90614ESF-BCK-000-SP is sourced from the original manufacturer or authorized distributors?

All MLX90614ESF-BCK-000-SP products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MLX90614ESF-BCK-000-SP meets industry standards.

7.What is the process for return or replacement of MLX90614ESF-BCK-000-SP?

All MLX90614ESF-BCK-000-SP units undergo pre-shipment inspection (PSI). If there is an issue with MLX90614ESF-BCK-000-SP, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The MLX90614ESF-BCK-000-SP part is unused and in its original packaging.

Return procedure for MLX90614ESF-BCK-000-SP:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

MLX90614ESF-BCK-000-SP Tags

  • MLX90614ESF-BCK-000-SP
  • MLX90614ESF-BCK-000-SP PDF
  • MLX90614ESF-BCK-000-SP Datasheet
  • MLX90614ESF-BCK-000-SP Specifications
  • MLX90614ESF-BCK-000-SP Images
  • Melexis Technologies NV
  • Melexis Technologies NV MLX90614ESF-BCK-000-SP
  • Buy MLX90614ESF-BCK-000-SP
  • MLX90614ESF-BCK-000-SP Price
  • MLX90614ESF-BCK-000-SP Distributor
  • MLX90614ESF-BCK-000-SP Supplier
  • MLX90614ESF-BCK-000-SP Wholesale
Related Products
MCP9700T-E/TT
MCP9700T-E/TT

Microchip Technology

MCP9700T-E/LT
MCP9700T-E/LT

Microchip Technology

MCP9701T-E/TT
MCP9701T-E/TT

Microchip Technology

MCP9701T-E/LT
MCP9701T-E/LT

Microchip Technology

TMP235A4DBZR
TMP235A4DBZR

Texas Instruments

MCP9700AT-E/TT
MCP9700AT-E/TT

Microchip Technology

MCP9700AT-E/LT
MCP9700AT-E/LT

Microchip Technology

MCP9701AT-E/LT
MCP9701AT-E/LT

Microchip Technology

MCP9701AT-E/TT
MCP9701AT-E/TT

Microchip Technology

LM335Z
LM335Z

STMicroelectronics

TMP1075NDRLR
TMP1075NDRLR

Texas Instruments

TMP1075DGKR
TMP1075DGKR

Texas Instruments

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER