Melexis Technologies NV MLX90614KSF-ABA-000-TU

Part No.:
MLX90614KSF-ABA-000-TU
Manufacturer:
Melexis Technologies NV
Category:
Analog and Digital Output
Package:
TO-39-4 Metal Can
Datasheet:
AetrixMLX90614KSF-ABA-000-TU.pdf
Description:
SENSOR DGTL -40C-125C TO39
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:2,330

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

MLX90614KSF-ABA-000-TU from Melexis is a factory-calibrated, single-zone infrared thermometer IC in TO-39 metal can package, delivering ±0.5°C accuracy from 0°C to +50°C for both ambient (Ta) and object (To) temperature, with object range spanning -70°C to +380°C and ambient range -40°C to +125°C. It integrates thermopile detector and signal-conditioning ASSP, supports SMBus digital interface and configurable PWM output, and is used in automotive blind-angle detection, thermal comfort control, and medical-grade body temperature sensing.

For engineers reviewing the MLX90614KSF-ABA-000-TU datasheet, pinout, applications, or equivalent options, key selection factors include its TO-39 package compatibility, SMBus slave address 0x5A, 10-bit PWM resolution, medical-accuracy option support, and thermal gradient compensation capability in xCx variants - all verified against Melexis Doc#3901090614 Rev 021.

Technical Context

The MLX90614KSF-ABA-000-TU implements a chopper-stabilized low-noise amplifier, 17-bit sigma-delta ADC, and programmable DSP for IR signal processing, enabling 0.02°C measurement resolution in SMBus mode. Its internal state machine controls dual-sensor readout (second sensor unimplemented in ABA variant), FIR/IIR filtering, and real-time Ta/To computation using factory-stored calibration coefficients stored in EEPROM.

Communication operates exclusively in SMBus slave mode at 10–100 kHz, with fixed 0x5A slave address (LSB programmable), POR-initiated default SMBus activation, and no sleep mode support - consistent with its Axx-series 5V supply architecture. The device uses an integrated long-wave pass optical filter (5.5–14 µm) for ambient/sunlight immunity and relies on isothermal mounting for specified accuracy.

Key Specifications

ParameterValue and Actual Design Meaning
Supply Voltage4.5–5.5 V - compatible with standard 5V systems; supports 8–16V operation via external components per Application Section 5.5
Ambient Temp Range-40°C to +125°C - validated for automotive-grade under-hood and cabin applications
Object Temp Range-70°C to +380°C - enables industrial hot-part monitoring and medical fever screening
Accuracy (Ta/To)±0.5°C from 0°C to +50°C - guaranteed only under isothermal conditions and thermal equilibrium
Output Resolution0.02°C (SMBus), 0.14°C (PWM) - SMBus delivers higher precision; PWM provides direct analog-like duty-cycle output
SMBus Address0x5A (default), LSB programmable - allows up to 127 devices on one bus with proper pull-up design
Current Consumption1.3–2.5 mA active - no sleep mode in Axx versions; not suitable for battery-critical ultra-low-power use

Pinout & Package

MLX90614KSF-ABA-000-TU is housed in an industry-standard 4-pin TO-39 metal can package with hermetically sealed IR window and integrated long-wave pass optical filter (5.5–14 µm). The metal can must connect to VSS only; no other electrical connection is permitted per Melexis EMC and isothermal guidelines.

Pin/TerminalCircuit RoleDesign Meaning
1: SCL / VzSMBus clock input / 5.7V zener clampAccepts SMBus clock; internal 5.7V zener protects against overvoltage on Axx variants
2: SDA / PWMSMBus data bidirectional / PWM outputConfigurable as open-drain SMBus data line or 10-bit free-running PWM output (default SMBus)
3: VDDPositive supply input4.5–5.5 V nominal; powers internal regulator, DSP, and EEPROM; no sleep mode support
4: VSSGround referenceSingle-point connection point for metal can; critical for thermal stability and EMC compliance

Key Features

FeatureDesign Value
Factory calibrationPre-programmed Ta/To coefficients across full operating range eliminate field calibration effort
Medical-accuracy optionSupports ±0.2°C accuracy near human body temperature when configured per medical variant specs
Customizable PWMUser-definable temperature range (-20°C to +120°C default) and resolution via EEPROM registers 0x00–0x01
Emissivity adjustmentCustomer-programmable emissivity (0.1–1.0) in EEPROM address 0x04 without black-body recalibration
Thermal relay modePWM pin reconfigurable as programmable thermostat output with user-defined To threshold and push-pull/NMOS open-drain options

Applications

Automotive Blind-Angle DetectionMedical Body Temperature Screening

Use Scenario: Detecting presence and proximity of pedestrians or vehicles outside driver's field of view using passive IR sensing mounted on side mirrors or rear pillars.

IC Role / Device Role / Timing Role: Non-contact object temperature sensor providing real-time thermal signature differentiation between ambient background and warm targets.

Use Value: Enables reliable motion-triggered alerts without radar complexity; leverages -70°C to +380°C To range and automotive-grade -40°C to +125°C Ta rating.

Use Scenario: Contactless forehead or tympanic temperature measurement in clinical triage, kiosks, or wearable health monitors.

IC Role / Device Role / Timing Role: High-accuracy IR thermometer delivering calibrated To readings with ±0.5°C (0°C–50°C) or ±0.2°C (medical variant) performance.

Use Value: Eliminates cross-contamination risk; achieves medical-grade resolution (0.02°C SMBus) and fast 250 ms valid output after POR.

Industrial Moving-Part MonitoringSmart HVAC Thermal Comfort Control

Use Scenario: Continuous surface temperature monitoring of rotating machinery, conveyor belts, or motor housings in factory automation systems.

IC Role / Device Role / Timing Role: Ambient-compensated IR sensor measuring To while rejecting self-heating effects via internal Ta compensation algorithm.

Use Value: Prevents unplanned downtime by detecting abnormal friction-induced heating; uses full -70°C to +380°C To range and robust TO-39 mechanical packaging.

Use Scenario: Occupancy-aware air conditioning control in office buildings or vehicles, adjusting setpoints based on localized human thermal presence.

IC Role / Device Role / Timing Role: Dual-role sensor measuring both ambient (Ta) and occupant-emitted (To) temperatures to infer occupancy and thermal comfort level.

Use Value: Reduces energy consumption by avoiding overcooling/heating; utilizes factory-calibrated Ta/To correlation and SMBus multi-drop capability for zone-based deployment.

Equivalent & Alternatives

The following parts are listed as comparable options for similar non-contact IR temperature sensing applications.

Alternative PartTechnical DifferenceApplication DifferenceSelection Advice
MLX90614ESF-ACC-000-TUAmbient temperature range limited to -40°C to +85°C; otherwise identical pinout, SMBus interface, and optical performanceSuitable for commercial HVAC or consumer appliances where extended ambient rating is unnecessarySelect when automotive or industrial under-hood/cabinet operation is not required - lower cost and qualification burden
AMG88338×8 thermal array (64 pixels) vs. single-point MLX90614; I²C interface; no built-in optical filter; requires external lens and calibrationEnables thermal imaging and gesture recognition; unsuitable for high-accuracy single-point spot measurementChoose for spatial temperature mapping; avoid when precise absolute To measurement or TO-39 mechanical integration is required

Compared with MLX90614ESF-ACC-000-TU, the MLX90614KSF-ABA-000-TU provides extended ambient operation critical for engine bay or industrial enclosures, while AMG8833 trades single-point accuracy for pixel-level thermal profiling - making MLX90614KSF-ABA-000-TU optimal for cost-sensitive, high-reliability spot-sensing where mechanical ruggedness and factory calibration are mandatory.

Availability

MLX90614KSF-ABA-000-TU is available at Aetrix Electronics and suitable for automotive blind-angle detection, medical body temperature screening, and industrial moving-part monitoring requiring stable component supply, long-term lifecycle continuity, and traceable sourcing.

Supply support for MLX90614KSF-ABA-000-TU includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

Melexis is a Belgian semiconductor company specializing in sensor and wireless RF ICs for automotive, industrial, and healthcare markets, with core expertise in magnetic, IR, and pressure sensing technologies.

The MLX90614 product line delivers factory-calibrated, single/dual-zone IR thermometers optimized for non-contact temperature measurement in space-constrained, thermally demanding environments - targeting automotive safety, medical diagnostics, and smart building control.

FAQ

What is the operating temperature range for MLX90614KSF-ABA-000-TU?

The MLX90614KSF-ABA-000-TU supports an ambient temperature range of -40°C to +125°C and an object temperature range of -70°C to +380°C. These ranges are validated per Melexis Doc#3901090614 Rev 021. Accuracy specifications (±0.5°C) apply only between 0°C and +50°C for both Ta and To, and require isothermal mounting conditions to maintain thermal equilibrium across the TO-39 package.

Does MLX90614KSF-ABA-000-TU support sleep mode?

No, MLX90614KSF-ABA-000-TU does not support sleep mode. As an Axx-series 5V device, it lacks the low-power sleep functionality found in Bxx (3V) variants. Its typical supply current is 1.3–2.5 mA in active operation, and power-down requires external VDD control. This is explicitly stated in Note 6 of Section 3.2.1 and confirmed in Table 7 footnotes of the official datasheet.

What is the default communication interface for MLX90614KSF-ABA-000-TU?

The factory default power-on reset (POR) setting for MLX90614KSF-ABA-000-TU is SMBus mode. Pin 2 (SDA/PWM) functions as an open-drain SMBus data line, and Pin 1 (SCL/Vz) serves as the clock input. The device operates as a slave with fixed 7-bit address 0x5A (LSB programmable), and switching to PWM mode requires EEPROM configuration via SMBus write to register 0x02.

Can MLX90614KSF-ABA-000-TU measure human body temperature accurately?

Yes, MLX90614KSF-ABA-000-TU achieves ±0.5°C accuracy from 0°C to +50°C - covering normal human body temperature (36°C–37.5°C) - when mounted under isothermal conditions. A dedicated medical-accuracy version (±0.2°C near 37°C) exists but requires specific variant ordering (e.g., MLX90614xxx-ABA-001-TU); the standard MLX90614KSF-ABA-000-TU supports this use case with proper optical path and calibration validation.

What optical filter is integrated into MLX90614KSF-ABA-000-TU?

MLX90614KSF-ABA-000-TU incorporates an integrated long-wave pass optical filter with transmission band 5.5 µm to 14 µm, blocking visible and near-infrared radiation to ensure ambient light and sunlight immunity. This filter is part of the TO-39 package assembly and is specified in Section 1 and Figure 1 of the datasheet; it is not present in xCH/xCI variants, which use uncoated silicon lenses instead.

MLX90614KSF-ABA-000-TU Specifications

Product attributes
Attribute value
Manufacturer:
Melexis Technologies NV
Series:
-
Package/Case:
TO-39-4 Metal Can
Packaging:
Tube
Product Status:
Active
Sensor Type:
Digital, Infrared (IR)
Sensing Temperature - Local:
-40°C ~ 125°C
Sensing Temperature - Remote:
-70°C ~ 380°C (IR)
Output Type:
PWM, SMBus
Voltage - Supply:
4.5V ~ 5.5V
Resolution:
16 b
Features:
Sleep Mode
Accuracy - Highest (Lowest):
±0.5°C (±4°C)
Test Condition:
0°C ~ 60°C (240°C ~ 380°C)
Operating Temperature:
-40°C ~ 125°C
Mounting Type:
Through Hole
Grade:
-
Qualification:
-
Supplier Device Package:
TO-39

MLX90614KSF-ABA-000-TU FAQ

1.How can I place an order for MLX90614KSF-ABA-000-TU through Aetrix?

Please submit a Request for Quotation (RFQ) for MLX90614KSF-ABA-000-TU on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for MLX90614KSF-ABA-000-TU reliable?

The price and inventory of MLX90614KSF-ABA-000-TU are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MLX90614KSF-ABA-000-TU is usually 5 days.

3.What payment methods are accepted for MLX90614KSF-ABA-000-TU?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MLX90614KSF-ABA-000-TU transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for MLX90614KSF-ABA-000-TU?

MLX90614KSF-ABA-000-TU orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your MLX90614KSF-ABA-000-TU order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for MLX90614KSF-ABA-000-TU?

For technical support, including MLX90614KSF-ABA-000-TU datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MLX90614KSF-ABA-000-TU requirements.

6.How does Aetrix verify that MLX90614KSF-ABA-000-TU is sourced from the original manufacturer or authorized distributors?

All MLX90614KSF-ABA-000-TU products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MLX90614KSF-ABA-000-TU meets industry standards.

7.What is the process for return or replacement of MLX90614KSF-ABA-000-TU?

All MLX90614KSF-ABA-000-TU units undergo pre-shipment inspection (PSI). If there is an issue with MLX90614KSF-ABA-000-TU, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The MLX90614KSF-ABA-000-TU part is unused and in its original packaging.

Return procedure for MLX90614KSF-ABA-000-TU:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

MLX90614KSF-ABA-000-TU Tags

  • MLX90614KSF-ABA-000-TU
  • MLX90614KSF-ABA-000-TU PDF
  • MLX90614KSF-ABA-000-TU Datasheet
  • MLX90614KSF-ABA-000-TU Specifications
  • MLX90614KSF-ABA-000-TU Images
  • Melexis Technologies NV
  • Melexis Technologies NV MLX90614KSF-ABA-000-TU
  • Buy MLX90614KSF-ABA-000-TU
  • MLX90614KSF-ABA-000-TU Price
  • MLX90614KSF-ABA-000-TU Distributor
  • MLX90614KSF-ABA-000-TU Supplier
  • MLX90614KSF-ABA-000-TU Wholesale
Related Products
MCP9700T-E/TT
MCP9700T-E/TT

Microchip Technology

MCP9700T-E/LT
MCP9700T-E/LT

Microchip Technology

MCP9701T-E/TT
MCP9701T-E/TT

Microchip Technology

MCP9701T-E/LT
MCP9701T-E/LT

Microchip Technology

TMP235A4DBZR
TMP235A4DBZR

Texas Instruments

MCP9700AT-E/TT
MCP9700AT-E/TT

Microchip Technology

MCP9700AT-E/LT
MCP9700AT-E/LT

Microchip Technology

MCP9701AT-E/LT
MCP9701AT-E/LT

Microchip Technology

MCP9701AT-E/TT
MCP9701AT-E/TT

Microchip Technology

LM335Z
LM335Z

STMicroelectronics

TMP1075NDRLR
TMP1075NDRLR

Texas Instruments

TMP1075DGKR
TMP1075DGKR

Texas Instruments

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER