Send an Inquiry

To receive a quote for your project, please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Part Number*
Quantity*
Message
Submit Inventory List

Please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Upload My List
Message

Silicon Labs RBK-ZWAVECALIBOX-3

Part No.:
RBK-ZWAVECALIBOX-3
Manufacturer:
Silicon Labs
Category:
RF, RFID, Wireless Evaluation Boards
Package:
Datasheet:
AetrixRBK-ZWAVECALIBOX-3.pdf
Description:
KIT CALIBRATION
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:2,198

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

RBK-ZWAVECALIBOX-3 from Silicon Labs is a dedicated hardware calibration interface tool for Z-Wave 500 Series devices (SD35xx, ZM5xxx, ZW05xx), enabling precise crystal and TX calibration during production programming via ZDP03A platform using SPI or UART interfaces. It delivers reference clock signals with ±0.5 ppm stability and supports automated enable-controlled calibration sequencing.

For engineers reviewing the RBK-ZWAVECALIBOX-3 datasheet, RBK-ZWAVECALIBOX-3 pinout, RBK-ZWAVECALIBOX-3 application, or RBK-ZWAVECALIBOX-3 equivalent, this tool is essential for achieving compliant Z-Wave 500 Series RF performance in final product assembly - especially where factory crystal calibration is incomplete or absent.

Technical Context

The RBK-ZWAVECALIBOX-3 operates as an external reference oscillator interface that injects a stable, temperature-compensated reference signal into Z-Wave 500 Series chips during calibration firmware execution. It synchronizes with ZDP03A's programming flow and triggers calibration via ENABLE logic-level control (active-low).

It supports two operational modes: combined crystal + TX calibration (requiring REF_OUT, ENABLE, GND) and TX-only calibration (using same interface but relying on pre-stored CCAL). Warm-up time is 2 minutes; reference output is derived from a high-stability OCXO-grade source referenced to the ZDP03A system clock domain.

Key Specifications

Parameter Value and Actual Design Meaning
Reference Output Stability ±0.5 ppm over operating temperature range - ensures frequency error < ±100 Hz at 916 MHz for compliant Z-Wave PHY layer calibration.
Enable Signal Logic Active-low TTL-compatible input - initiates calibration sequence only when pulled to GND after warm-up.
Power Input 100–240 VAC, 50/60 Hz - enables standalone operation without dependency on ZDP03A power rails.
Warm-up Time 2 minutes - required stabilization period before REF_OUT achieves specified accuracy; calibration must not begin earlier.
Interface Compatibility Direct connection to ZDP03A J6 (SPI) or J16/J9 (UART) - no level-shifting or adapter needed for supported Z-Wave 500 Series modules.
Supported Calibration Types Crystal calibration (CCAL) and TX calibration (TXCAL1/TXCAL2) - both stored in NVR per SDS12467 specification.

Availability

RBK-ZWAVECALIBOX-3 is available at Aetrix Electronics and suitable for Z-Wave smart home device manufacturing, industrial IoT gateway production, and certified Z-Wave module calibration requiring stable component supply and traceable calibration infrastructure.

Supply support for RBK-ZWAVECALIBOX-3 includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

Silicon Labs is a fabless semiconductor company specializing in secure, intelligent wireless SoCs and development tools for IoT applications, headquartered in Austin, Texas.

The RBK-ZWAVECALIBOX-3 belongs to Silicon Labs' Z-Wave ecosystem support hardware line, designed specifically to ensure production-line compliance with Z-Wave 500 Series RF certification requirements and NVR calibration data integrity.

FAQ

What is the primary function of the RBK-ZWAVECALIBOX-3?

The RBK-ZWAVECALIBOX-3 provides a calibrated reference clock signal and enable control to perform mandatory crystal and TX calibration on Z-Wave 500 Series devices (SD35xx, ZM5xxx, ZW05xx) during production programming. It ensures RF frequency accuracy required for Z-Wave certification and interoperability. The RBK-ZWAVECALIBOX-3 integrates directly with the ZDP03A platform and executes calibration sequences defined in INS12524.

Which Z-Wave devices require use of the RBK-ZWAVECALIBOX-3?

The RBK-ZWAVECALIBOX-3 is required for SD35xx chips and ZW05xx die-level assemblies, which undergo full crystal + TX calibration during customer production. It is also used for ZM5101 modules needing post-factory TX calibration. The RBK-ZWAVECALIBOX-3 is not needed for ZM5202 or ZM5304, which ship fully calibrated from Silicon Labs.

How does the RBK-ZWAVECALIBOX-3 connect to the ZDP03A platform?

The RBK-ZWAVECALIBOX-3 connects via flywires or Molex J3-to-J6 cabling depending on version: REF_OUT, ENABLE, and GND pins link to designated ZDP03A headers (e.g., J16 pin 10, J10 pin 1, J10 pin 10 for SPI mode). Connection diagrams and pin mappings are documented in Tables 2–5 of INS12524-8.

What is the warm-up requirement for the RBK-ZWAVECALIBOX-3?

The RBK-ZWAVECALIBOX-3 requires a 2-minute warm-up period after power-on before calibration may begin. This ensures thermal stabilization of its internal reference oscillator and guarantees ±0.5 ppm output accuracy. Attempting calibration before warm-up completion risks invalid CCAL or TXCAL values in the device's NVR.

Can the RBK-ZWAVECALIBOX-3 be used for both SPI and UART programming interfaces?

Yes - the RBK-ZWAVECALIBOX-3 supports both SPI and UART-based calibration flows on the ZDP03A platform. Pin assignments differ: for SPI, REF_OUT connects to J16 pin 10 and ENABLE to J10 pin 1; for UART, REF_OUT connects to J16 pin 11 and ENABLE to J9 pin 6. These configurations are validated in Tables 2, 3, 4, and 5 of the 500 Series Calibration User Guide.

RBK-ZWAVECALIBOX-3 Specifications

Product attributes
Attribute value
Manufacturer:
Silicon Labs
Series:
Z-Wave®
Packaging:
Box
Product Status:
Obsolete
Type:
Transceiver, Z-Wave
Frequency:
-
Contents:
Board(s)
Utilized IC / Part:
-

RBK-ZWAVECALIBOX-3 FAQ

1.How can I place an order for RBK-ZWAVECALIBOX-3 through Aetrix?

Please submit a Request for Quotation (RFQ) for RBK-ZWAVECALIBOX-3 on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for RBK-ZWAVECALIBOX-3 reliable?

The price and inventory of RBK-ZWAVECALIBOX-3 are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for RBK-ZWAVECALIBOX-3 is usually 5 days.

3.What payment methods are accepted for RBK-ZWAVECALIBOX-3?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for RBK-ZWAVECALIBOX-3 transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for RBK-ZWAVECALIBOX-3?

RBK-ZWAVECALIBOX-3 orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your RBK-ZWAVECALIBOX-3 order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for RBK-ZWAVECALIBOX-3?

For technical support, including RBK-ZWAVECALIBOX-3 datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your RBK-ZWAVECALIBOX-3 requirements.

6.How does Aetrix verify that RBK-ZWAVECALIBOX-3 is sourced from the original manufacturer or authorized distributors?

All RBK-ZWAVECALIBOX-3 products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that RBK-ZWAVECALIBOX-3 meets industry standards.

7.What is the process for return or replacement of RBK-ZWAVECALIBOX-3?

All RBK-ZWAVECALIBOX-3 units undergo pre-shipment inspection (PSI). If there is an issue with RBK-ZWAVECALIBOX-3, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The RBK-ZWAVECALIBOX-3 part is unused and in its original packaging.

Return procedure for RBK-ZWAVECALIBOX-3:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

RBK-ZWAVECALIBOX-3 Tags

  • RBK-ZWAVECALIBOX-3
  • RBK-ZWAVECALIBOX-3 PDF
  • RBK-ZWAVECALIBOX-3 Datasheet
  • RBK-ZWAVECALIBOX-3 Specifications
  • RBK-ZWAVECALIBOX-3 Images
  • Silicon Labs
  • Silicon Labs RBK-ZWAVECALIBOX-3
  • Buy RBK-ZWAVECALIBOX-3
  • RBK-ZWAVECALIBOX-3 Price
  • RBK-ZWAVECALIBOX-3 Distributor
  • RBK-ZWAVECALIBOX-3 Supplier
  • RBK-ZWAVECALIBOX-3 Wholesale
Related Products
113991054
113991054

Seeed Technology Co., Ltd

SC0918
SC0918

Raspberry Pi

113991114
113991114

Seeed Technology Co., Ltd

ESP32-C6-DEVKITM-1-N4
ESP32-C6-DEVKITM-1-N4

Espressif Systems

ESP32-DEVKITM-1
ESP32-DEVKITM-1

Espressif Systems

C008
C008

M5Stack Technology Co., Ltd.

ESP32-C3-DEVKITC-02
ESP32-C3-DEVKITC-02

Espressif Systems

ESP32-C6-DEVKITC-1-N8
ESP32-C6-DEVKITC-1-N8

Espressif Systems

DFR0478
DFR0478

DFRobot

102010448
102010448

Seeed Technology Co., Ltd

ESP32-DEVKITC-32E
ESP32-DEVKITC-32E

Espressif Systems

ESP32-DEVKITC-32UE
ESP32-DEVKITC-32UE

Espressif Systems

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER