Vishay Semiconductor Opto Division TLUR2400
- Part No.:
- TLUR2400
- Manufacturer:
- Vishay Semiconductor Opto Division
- Category:
- LED Indication - Discrete
- Package:
- Radial
- Datasheet:
-
TLUR2400.pdf
- Description:
- LED RED DIFFUSED 1.8MM T/H
- Quantity:
- Payment:

- Shipping:

Inventory:4,612
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
TLUR2400 from Vishay Semiconductors is a red visible-light LED in a 1.8 mm tinted diffused miniplast package, with dominant wavelength 630 nm, luminous intensity 4–15 mcd at 10 mA, forward voltage 2–3 V at 20 mA, and ±20° viewing angle. It is rated for DC and pulsed operation up to 20 mA continuous forward current and used for status indication in industrial control panels and consumer device interfaces.
For engineers reviewing the TLUR2400 datasheet, TLUR2400 pinout, TLUR2400 application, or TLUR2400 equivalent, key selection factors include luminous intensity binning (P–R groups), thermal resistance (450 K/W), reverse voltage limit (6 V), junction temperature rating (100 °C), and compatibility with 2.54 mm pitch stackable mounting.
Technical Context
The TLUR2400 is a GaAsP-on-GaP heterostructure LED optimized for high-efficiency red emission at 630 nm dominant wavelength and 640 nm peak wavelength. Its 1.8 mm miniplast package features tinted diffused epoxy for uniform angular output and ±20° half-intensity angle.
It operates within -40 to +100 °C ambient range, supports 25 ms pulse testing for luminous intensity, and is categorized into discrete luminous intensity bins (P, Q, R) - with TLUR2400 specifically assigned to P (4–8 mcd) and Q (6.3–12.5 mcd) groups per shipment bag.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Dominant wavelength | 630 nm - defines human-perceived red color tone for consistent visual signaling |
| Luminous intensity | 4–15 mcd at 10 mA - determines visibility under standard drive conditions |
| Forward voltage | 2–3 V at 20 mA - sets minimum supply headroom and series resistor sizing |
| Viewing angle | ±20° - defines beam spread for localized vs. wide-area indication |
| Junction-to-ambient thermal resistance | 450 K/W - limits power dissipation to 60 mW at Tamb ≤ 55 °C |
| Absolute max forward current | 20 mA DC - defines continuous drive ceiling without degradation |
| Reverse voltage rating | 6 V - constrains allowable reverse bias in multiplexed or AC-coupled circuits |
Pinout & Package
Package: 1.8 mm diameter miniplast (tinted diffused epoxy), radial leaded, cathode-indicated by flat side and shorter lead.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| Anode (longer lead) | Positive current entry | Must be biased ≥2 V above cathode to emit light; polarity-sensitive in PCB layout |
| Cathode (shorter lead, flat side) | Current return path | Connected to ground or low-side switch; identifies orientation during automated placement |
Key Features
| Feature | Design Value |
|---|---|
| DC and pulse operation support | Rated for continuous 20 mA or short pulses (≤25 ms), enabling flexible drive schemes including multiplexing |
| Luminous intensity binning | Shipped in single brightness groups (P/Q/R) per bag - ensures consistent visual output across production batches |
| End-to-end stackable design | 0.1" (2.54 mm) center-to-center spacing - simplifies dense indicator arrays on control panels and dashboards |
| Tinted diffused miniplast package | Uniform Lambertian emission profile with ±20° half-angle - eliminates hot spots and improves readability at off-axis angles |
Applications
| Industrial Control Panel Indicators | Consumer Appliance Status Lights |
|---|---|
Use Scenario: LED mounted on PLC I/O module front panel to indicate input activation or fault condition. IC Role / Device Role / Timing Role: Discrete optical indicator providing real-time visual feedback of digital signal state. Use Value: High-visibility red emission at 630 nm ensures recognition under factory lighting; ±20° viewing angle matches operator line-of-sight geometry. | Use Scenario: Power-on and cycle-complete indicators on microwave oven or washing machine control board. IC Role / Device Role / Timing Role: Human-interface status emitter driven directly from microcontroller GPIO pins. Use Value: 2–3 V forward voltage enables direct 3.3 V or 5 V MCU drive with minimal series resistance; 100 °C operating range withstands enclosure heat buildup. |
| Test Equipment Power-On LEDs | Medical Device Ready Indicators |
Use Scenario: "Power Applied" indicator on bench multimeter or oscilloscope front bezel. IC Role / Device Role / Timing Role: Steady-state visual confirmation of main power rail presence. Use Value: 450 K/W thermal resistance allows reliable operation without heatsinking in compact enclosures; 60 mW power dissipation limit aligns with low-power design targets. | Use Scenario: "System Ready" light on patient monitor or infusion pump interface. IC Role / Device Role / Timing Role: Safety-critical status indicator requiring stable luminance over lifetime. Use Value: Luminous intensity binning (P/Q groups) ensures consistent brightness across units; -40 to +100 °C operating range supports clinical and transport environments. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar red LED indicator applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| TLUR2401 | Higher luminous intensity (4–32 mcd vs. 4–15 mcd); same package, wavelength, and electrical specs | Better suited for high-ambient-light environments where higher brightness is required | Select TLUR2401 when >15 mcd typical output is needed; TLUR2400 remains optimal for lower-power or glare-sensitive use cases |
| TLHR5400 | Same 1.8 mm miniplast package, but hyper-red (650 nm), higher VF (2.4–3.4 V), and wider viewing angle (±30°) | Used where deeper red hue or broader coverage is prioritized over exact 630 nm match | Choose TLHR5400 only if spectral shift or angular spread is acceptable; not a direct replacement for 630 nm-critical designs |
Compared with TLUR2401 and TLHR5400, the TLUR2400 provides the most tightly controlled 630 nm red output with moderate intensity and narrow viewing angle - making it ideal for applications demanding color consistency and directional visibility without overdriving.
Availability
TLUR2400 is available at Aetrix Electronics and suitable for industrial control panels, consumer appliance interfaces, test equipment status displays, and medical device ready indicators requiring stable component supply and consistent luminous intensity binning.
Supply support for TLUR2400 includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Vishay Semiconductors is a global leader in discrete semiconductors and passive components, specializing in high-reliability optoelectronics, power MOSFETs, diodes, and resistive sensors.
The TLUR2400 belongs to Vishay's standard miniplast LED product line, engineered for cost-effective, high-volume visual indication in industrial, automotive, and consumer electronics where consistent color, stable intensity, and mechanical stackability are essential.
FAQ
What is the dominant wavelength of the TLUR2400?
The TLUR2400 has a dominant wavelength of 630 nm, which produces a standard red emission perceptible to the human eye under typical ambient lighting. This value is measured at 10 mA forward current and is consistent across all TLUR2400 units regardless of luminous intensity bin (P, Q, or R). The 630 nm specification makes the TLUR2400 suitable for applications requiring precise red color matching, such as safety-critical status indicators and industrial HMI panels.
What luminous intensity range does the TLUR2400 cover?
The TLUR2400 delivers a luminous intensity of 4–15 mcd at 10 mA, with units binned into P (4–8 mcd) and Q (6.3–12.5 mcd) groups. Each shipping bag contains only one brightness group to ensure visual consistency across assemblies. The TLUR2400 does not extend to the R (10–20 mcd) or higher bins - those are reserved for the TLUR2401 variant. This controlled binning supports repeatable optical performance in volume manufacturing.
Can the TLUR2400 be used in pulsed operation?
Yes, the TLUR2400 is explicitly rated for both DC and pulse operation. Luminous intensity is tested using a 25 ms current pulse, and the device supports surge forward current up to 0.5 A for tp ≤ 10 μs. For multiplexed display applications, designers must ensure average power dissipation stays within 60 mW and junction temperature remains below 100 °C. Pulse operation preserves LED lifetime while enabling dynamic brightness control without external drivers.
What is the maximum forward current rating for the TLUR2400?
The absolute maximum DC forward current for the TLUR2400 is 20 mA at Tamb ≤ 55 °C. Exceeding this value risks accelerated degradation or thermal runaway due to its 450 K/W junction-to-ambient thermal resistance. At elevated ambient temperatures, derating is required - e.g., ~15 mA at 85 °C. The TLUR2400 is not rated for continuous operation above 20 mA, and surge current (0.5 A) is strictly limited to ≤10 μs pulses.
Is the TLUR2400 compatible with automated PCB assembly?
Yes, the TLUR2400 is designed for automated placement with its standardized 1.8 mm miniplast package, radial leads, and clear cathode identification via flat side and shorter lead. Tape-and-reel packaging (2000 units per reel, AS12 orientation code) supports pick-and-place machines. The 2.54 mm center-to-center stackable footprint also aligns with common SMT feeder pitch requirements, enabling high-density indicator arrays without manual rework.
TLUR2400 Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Vishay Semiconductor Opto Division
- Series:
- -
- Package/Case:
- Radial
- Packaging:
- Bulk
- Product Status:
- Active
- Color:
- Red
- Configuration:
- Standard
- Lens Color:
- -
- Lens Transparency:
- Diffused
- Millicandela Rating:
- 15mcd
- Lens Style:
- Round with Domed Top
- Lens Size:
- -
- Voltage - Forward (Vf) (Typ):
- 2V
- Current - Test:
- 10mA
- Viewing Angle:
- 40°
- Mounting Type:
- Through Hole
- Wavelength - Dominant:
- 630nm
- Wavelength - Peak:
- 640nm
- Features:
- -
- Grade:
- -
- Qualification:
- -
- Supplier Device Package:
- 1.8mm Miniplast
- Size / Dimension:
- -
TLUR2400 FAQ
1.How can I place an order for TLUR2400 through Aetrix?
Please submit a Request for Quotation (RFQ) for TLUR2400 on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for TLUR2400 reliable?
The price and inventory of TLUR2400 are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for TLUR2400 is usually 5 days.
3.What payment methods are accepted for TLUR2400?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for TLUR2400 transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for TLUR2400?
TLUR2400 orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your TLUR2400 order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for TLUR2400?
For technical support, including TLUR2400 datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your TLUR2400 requirements.
6.How does Aetrix verify that TLUR2400 is sourced from the original manufacturer or authorized distributors?
All TLUR2400 products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that TLUR2400 meets industry standards.
7.What is the process for return or replacement of TLUR2400?
All TLUR2400 units undergo pre-shipment inspection (PSI). If there is an issue with TLUR2400, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The TLUR2400 part is unused and in its original packaging.
Return procedure for TLUR2400:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
TLUR2400 Tags

-
LTST-C281KRKT
Lite-On Inc.

-
150060GS75000
Würth Elektronik

-
150060VS75000
Würth Elektronik

-
150060AS75000
Würth Elektronik

-
150060YS75000
Würth Elektronik

-
150060SS75000
Würth Elektronik

-
150060BS75000
Würth Elektronik

-
151031VS06000
Würth Elektronik

-
151033RS03000
Würth Elektronik

-
150080BS75000
Würth Elektronik

-
150080GS75000
Würth Elektronik

-
150141GS73100
Würth Elektronik
Tech Hub
Comparator circuit design covering voltage thresholds, input limits, open-collector outputs, LM393 wiring, op-amp differences, hysteresis, timing, window detection and practical fault diagnosis.
Schmitt triggers use separate rising and falling thresholds to stabilize slow or noisy signals. This guide covers hysteresis, 74HC14 and 74HCT14 selection, comparator calculations, RC oscillators and p…
Counterfeit components can hide behind convincing markings and passing basic function tests. This engineering reference covers source traceability, external inspection, X-ray, XRF, electrical testing, …
A practical engineering and sourcing framework covering lifecycle verification, lifetime-buy calculations, replacement qualification, supplier checks and counterfeit-risk controls.
TTL and CMOS logic families differ in thresholds, loading, output drive, power and timing. This engineering guide compares 74HC and 74HCT, calculates noise margins and checks 3.3 V/5 V compatibility.
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
