Elettrotek Kabel North America 39330CEX042A26
- Part No.:
- 39330CEX042A26
- Manufacturer:
- Elettrotek Kabel North America
- Category:
- Multiple Conductor Cables
- Package:
- Datasheet:
-
39330CEX042A26.pdf
- Description:
- PROFINET CABLE 682 UL CAT 5E 300
- Quantity:
- Payment:

- Shipping:

Inventory:27,107
Please send an inquiry. Send us your inquiry, and we will respond immediately.
39330CEX042A26 Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Elettrotek Kabel North America
- Series:
- -
- Packaging:
- Spool
- Product Status:
- Active
- Cable Type:
- Multi-Pair, Cat5e
- Number of Conductors:
- 8 (4 Pair)
- Wire Gauge:
- 26 AWG
- Conductor Strand:
- -
- Conductor Material:
- Copper, Tinned
- Jacket (Insulation) Material:
- Polyurethane (PU)
- Jacket (Insulation) Diameter:
- 0.287" (7.29mm)
- Shield Type:
- Foil, Braid
- Length:
- Enter Number of Feet in Order Quantity
- Jacket Color:
- Green
- Ratings:
- AWM Style 10493-20233
- Features:
- Flame Retardant, Halogen-Free, Mud Resistant, Oil Resistant, UV Resistant
- Voltage:
- 350 V
- Operating Temperature:
- -30°C ~ 70°C
- Usage:
- Industrial, Data
- Jacket (Insulation) Thickness:
- -
- Conductor Insulation:
- Polypropylene (PP)
- Size / Dimension:
- -
39330CEX042A26 FAQ
1.How can I place an order for 39330CEX042A26 through Aetrix?
Please submit a Request for Quotation (RFQ) for 39330CEX042A26 on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for 39330CEX042A26 reliable?
The price and inventory of 39330CEX042A26 are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for 39330CEX042A26 is usually 5 days.
3.What payment methods are accepted for 39330CEX042A26?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for 39330CEX042A26 transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for 39330CEX042A26?
39330CEX042A26 orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your 39330CEX042A26 order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for 39330CEX042A26?
For technical support, including 39330CEX042A26 datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your 39330CEX042A26 requirements.
6.How does Aetrix verify that 39330CEX042A26 is sourced from the original manufacturer or authorized distributors?
All 39330CEX042A26 products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that 39330CEX042A26 meets industry standards.
7.What is the process for return or replacement of 39330CEX042A26?
All 39330CEX042A26 units undergo pre-shipment inspection (PSI). If there is an issue with 39330CEX042A26, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The 39330CEX042A26 part is unused and in its original packaging.
Return procedure for 39330CEX042A26:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
39330CEX042A26 Tags

-
E1004S.41.10
Prysmian Group

-
E1004S.30.10
Prysmian Group

-
5300UG 009U500
Belden Inc.
-
C1357.41.90
Prysmian Group
-
E1006S.30.10
Prysmian Group

-
5502FE 008U500
Belden Inc.

-
5300UG 008U500
Belden Inc.

-
E3042S.41.86
Prysmian Group

-
5402UE 008U1000
Belden Inc.

-
21458-22-2-0500-0104-1-TS
CNC Tech

-
5300UE 0081000
Belden Inc.

-
5400FE 0081000
Belden Inc.
Tech Hub
Engineering guide to output capacitor selection for ASIC Vcore rails, covering bulk capacitors, polymer capacitors, MLCC decoupling, DC bias, ESR, ESL, placement, transient response and substitution ri…
Engineering guide to high-current ASIC Vcore rails, covering 12-phase buck architecture, PMBus control, dynamic load testing, output capacitor networks, smart power stage selection, thermal design and …
Voltage regulator guide covering linear, LDO, 7805, Zener, adjustable, buck, VRM and alternator regulators, with design checks, testing methods, troubleshooting and datasheet-based selection.
Amplifier guide covering voltage, current and power amplification, gain, feedback, amplifier classes, audio and RF applications, op-amp circuits, transimpedance amplifiers, datasheet selection and trou…
Machine vision system guide covering components, inspection workflow, camera and lens selection, FOV, pixel resolution, motion blur, strobe lighting, bandwidth, 2D/3D vision, integration, troubleshooti…
Electronic devices and circuits guide covering passive components, semiconductors, analog and digital circuits, circuit theory, practical calculations, troubleshooting, datasheet selection, and learnin…
Oil pressure sensor diagnosis covering symptoms, location, testing, replacement, socket access, common failure cases, and the electronic signal path between the pressure sensor, wiring, ECU and gauge s…
MLCC ESR, impedance and self-resonant frequency in decoupling networks. Covers PDN behavior, frequency response, measurement methods, failure cases and practical capacitor selection for power integrity…
An actuator converts a control signal and energy source into mechanical motion. This guide explains actuator types, working principles, electric and linear actuators, automotive use cases, troubleshoot…
A potentiometer is a three-terminal adjustable resistor used for voltage division, analog control, calibration and signal adjustment. This guide explains wiring, symbols, types, 10k values, digital pot…

