Send an Inquiry

To receive a quote for your project, please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Part Number*
Quantity*
Message
Submit Inventory List

Please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Upload My List
Message

Analog Devices Inc. 5B30-03-NI

Part No.:
5B30-03-NI
Manufacturer:
Analog Devices Inc.
Category:
Sensor, Transducer Amplifiers
Package:
Datasheet:
Aetrix5B30-03-NI.pdf
Description:
MODULE
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:1,340

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

5B30-03-NI from Analog Devices is a single-channel isolated voltage input signal conditioner that amplifies, filters, protects, and isolates millivolt-level analog signals. It accepts ±100 mV input range, delivers ±5 V output, provides 1500 Vrms continuous isolation, and features chopper-stabilized amplification with ±1 µV/°C input offset drift-used in industrial temperature monitoring systems with thermocouple front-ends.

For engineers reviewing the 5B30-03-NI datasheet, 5B30-03-NI pinout, 5B30-03-NI application, or 5B30-03-NI equivalent, key selection criteria include its ±100 mV input range, transformer-based isolation architecture, 4 Hz low-pass filter cutoff, field-side floating differential input, and hot-swappable 2.27" × 2.32" × 0.595" module form factor.

Technical Context

The 5B30-03-NI implements transformer-coupled signal isolation using proprietary modulation for linear performance, with a chopper-stabilized input amplifier delivering ±1 µV/°C input offset drift and ±25 ppm/°C gain stability. Its fully floating differential input eliminates need for input grounding, and internal multi-pole filtering achieves 160 dB common-mode rejection at 50/60 Hz with 4 Hz –3 dB bandwidth.

Input protection withstands 240 Vrms continuously at screw terminals; output includes a series switch controlled by active-low enable, and output common must remain within ±3 V of power common. The module operates across –40°C to +85°C and meets FM Class 1 Division 2 and CSA hazardous location approvals.

Key Specifications

ParameterValue and Actual Design Meaning
Input Range±100 mV - supports low-level millivolt signals from strain gauges or thermopile sensors
Output Range±5 V - compatible with standard bipolar ADC inputs and PLC analog inputs
Isolation Rating1500 Vrms continuous - enables safe interface between hazardous field-side and protected computer-side circuits
Accuracy±0.05% span ±10 µV RTI - ensures high-fidelity measurement in precision industrial control loops
Bandwidth4 Hz (–3 dB) - suppresses 50/60 Hz line noise while preserving slow-varying process signals
Input Offset Drift±1 µV/°C - minimizes thermal error in unattended long-duration measurements
Common-Mode Rejection160 dB at 50/60 Hz - rejects noise from shared ground paths in electrically noisy plants

Pinout & Package

5B30-03-NI uses a standardized 4-pin screw-terminal input interface in a potted, DIN-rail-mountable module measuring 2.275" × 2.375" × 0.595" (57.8 mm × 59.1 mm × 15.1 mm). Pin assignments are field-side only; no computer-side pins are user-accessible.

Pin/TerminalCircuit RoleDesign Meaning
1No ConnectUnused terminal; left unconnected per design
2LOW –Inverting input terminal for differential voltage sensing; referenced to HIGH +
3HIGH +Non-inverting input terminal; forms floating differential pair with LOW –
4No ConnectUnused terminal; left unconnected per design

Key Features

FeatureDesign Value
Fully floating differential inputEliminates need for field-side grounding, enabling direct connection to ungrounded sensors
Transformer-based isolationProvides 1500 Vrms galvanic separation without optocoupler aging or drift
Chopper-stabilized amplifierDelivers ±1 µV/°C input offset drift for stable zero-point accuracy over temperature
Integrated 4 Hz low-pass filterAttenuates 50/60 Hz interference without external components or tuning
240 Vrms input protectionWithstands sustained overvoltage faults without damage to downstream DAQ or controller circuitry

Applications

Temperature Monitoring SystemStrain Gauge Signal Conditioning

Use Scenario: Measuring J/K-type thermocouple outputs in refinery furnace zones with high EMI and ground potential differences.

IC Role / Device Role / Timing Role: Isolated voltage input conditioner converting thermocouple mV output to ±5 V while rejecting common-mode transients.

Use Value: Enables accurate cold-junction compensation and eliminates ground-loop errors via 1500 Vrms isolation and 160 dB CMR.

Use Scenario: Reading microvolt-level bridge outputs from load cells in hydraulic press control systems.

IC Role / Device Role / Timing Role: Amplifying and protecting ±100 mV differential signals before digitization by 16-bit PLC analog inputs.

Use Value: Delivers ±0.05% span accuracy and ±1 µV/°C drift stability for repeatable force calibration across ambient shifts.

Hazardous Area Data AcquisitionLegacy System Signal Interface

Use Scenario: Connecting field instruments in Class 1 Division 2 gas-processing areas to non-incendive control room DAQ systems.

IC Role / Device Role / Timing Role: FM- and CSA-certified isolated signal conditioner meeting intrinsic safety boundary requirements.

Use Value: Eliminates need for explosion-proof enclosures while maintaining compliance with ANSI/IEEE C37.90.1 transient immunity.

Use Scenario: Interfacing vintage 0–100 mV analog transmitters to modern 0–5 V ADC-equipped controllers.

IC Role / Device Role / Timing Role: Level-shifting and isolating legacy sensor outputs to prevent ground contamination of new control hardware.

Use Value: Provides seamless integration without rewiring or signal conditioning redesign, leveraging hot-swap capability.

Equivalent & Alternatives

The following parts are listed as comparable options for similar isolated voltage input conditioning applications.

Alternative PartTechnical DifferenceApplication DifferenceSelection Advice
5B30-03Same electrical specs but lacks NI (non-incendive) certification markings and FM/CSA Class 1 Div 2 approvalNot approved for hazardous locations requiring non-incendive classificationSelect 5B30-03-NI when operating in FM/CSA-certified hazardous environments; use 5B30-03 only in general industrial settings.
AD210BNSingle-ended input, ±10 V max input, 1000 Vrms isolation, no built-in 4 Hz filterRequires external anti-aliasing and lacks certified hazardous-area ratingChoose AD210BN only for higher-bandwidth, non-hazardous applications where external filtering is acceptable.

Compared with 5B30-03 and AD210BN, the 5B30-03-NI uniquely combines FM/CSA non-incendive certification, integrated 4 Hz filtering, and ±100 mV input range in a hot-swappable module-making it the sole option qualified for certified hazardous-area deployment with millivolt-level sensor interfacing.

Availability

5B30-03-NI is available at Aetrix Electronics and suitable for industrial temperature monitoring, hazardous-area data acquisition, and legacy analog system upgrades requiring stable component supply and certified isolation performance.

Supply support for 5B30-03-NI includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

Analog Devices is a global semiconductor company specializing in high-performance analog, mixed-signal, and digital signal processing technologies for industrial, automotive, and communications markets.

The 5B Series was designed specifically for rugged industrial signal conditioning-delivering transformer-isolated, hot-swappable, FM/CSA-certified modules that replace custom-built isolation solutions in measurement and control systems.

FAQ

What is the input voltage range supported by the 5B30-03-NI?

The 5B30-03-NI supports a nominal input range of ±100 mV, optimized for low-level millivolt sources such as thermocouples and strain gauge bridges. This range is factory-set and laser-trimmed for accuracy; the module does not support reconfiguration to other ranges without custom ordering. Input overload protection sustains up to 240 Vrms without damage, ensuring robustness in industrial environments where voltage transients occur.

Does the 5B30-03-NI require external power supply filtering or decoupling?

No, the 5B30-03-NI operates from a single +5 V ±5% supply and incorporates internal regulation and noise suppression. Its power supply sensitivity is specified at ±2 µV/Vs% RTI, meaning supply ripple contributes negligible error. A standard 10 µF bulk capacitor near the backplane power entry is sufficient; no additional local decoupling is required at the module level due to its potted construction and integrated filtering.

Can the 5B30-03-NI be used with grounded or single-ended sensors?

Yes-the 5B30-03-NI's fully floating differential input allows connection to grounded, single-ended, or ungrounded sensors without modification. The LOW – and HIGH + terminals form a true differential pair with no reference to system ground; this eliminates ground-loop errors and enables direct interface to sensors with arbitrary grounding schemes, including those referenced to earth or chassis potential.

What certifications apply to the 5B30-03-NI for hazardous area use?

The 5B30-03-NI carries Factory Mutual (FM) and Canadian Standards Association (CSA) approvals for Class 1, Division 2, Groups A, B, C, and D locations. These certifications confirm its non-incendive classification-meaning it may be used where flammable gases could exist only under fault conditions, without requiring explosion-proof enclosures. The "NI" suffix explicitly denotes this certified non-incendive status, distinguishing it from standard 5B30-03 units.

How does the 4 Hz bandwidth affect signal fidelity in process control applications?

The 4 Hz –3 dB bandwidth of the 5B30-03-NI is intentionally optimized for industrial process variables (e.g., temperature, pressure, flow), which change slowly and are dominated by 50/60 Hz noise. This fixed low-pass response rejects line-frequency interference while preserving step response fidelity for typical loop update rates. Rise time is 200 ms (10% to 90%), aligning with standard PID controller scan times and eliminating need for external filtering.

5B30-03-NI Specifications

Product attributes
Attribute value
Manufacturer:
Analog Devices Inc.
Series:
-
Packaging:
Tray
Product Status:
Obsolete
Amplifier Type:
General Purpose
Voltage - Supply:
4.75V ~ 5.25V
Output Type:
Analog
Current - Supply:
30 mA
Operating Temperature:
-40°C ~ 85°C
Mounting Type:
Surface Mount

5B30-03-NI FAQ

1.How can I place an order for 5B30-03-NI through Aetrix?

Please submit a Request for Quotation (RFQ) for 5B30-03-NI on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for 5B30-03-NI reliable?

The price and inventory of 5B30-03-NI are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for 5B30-03-NI is usually 5 days.

3.What payment methods are accepted for 5B30-03-NI?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for 5B30-03-NI transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for 5B30-03-NI?

5B30-03-NI orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your 5B30-03-NI order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for 5B30-03-NI?

For technical support, including 5B30-03-NI datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your 5B30-03-NI requirements.

6.How does Aetrix verify that 5B30-03-NI is sourced from the original manufacturer or authorized distributors?

All 5B30-03-NI products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that 5B30-03-NI meets industry standards.

7.What is the process for return or replacement of 5B30-03-NI?

All 5B30-03-NI units undergo pre-shipment inspection (PSI). If there is an issue with 5B30-03-NI, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The 5B30-03-NI part is unused and in its original packaging.

Return procedure for 5B30-03-NI:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

5B30-03-NI Tags

  • 5B30-03-NI
  • 5B30-03-NI PDF
  • 5B30-03-NI Datasheet
  • 5B30-03-NI Specifications
  • 5B30-03-NI Images
  • Analog Devices Inc.
  • Analog Devices Inc. 5B30-03-NI
  • Buy 5B30-03-NI
  • 5B30-03-NI Price
  • 5B30-03-NI Distributor
  • 5B30-03-NI Supplier
  • 5B30-03-NI Wholesale
Related Products
SEN-13879
SEN-13879

SparkFun Electronics

GA-311
GA-311

Panasonic Industrial Automation Sales

E32-T11N 2M
E32-T11N 2M

Omron Automation and Safety

FX-501P
FX-501P

Panasonic Industrial Automation Sales

FX-501
FX-501

Panasonic Industrial Automation Sales

E3X-HD44
E3X-HD44

Omron Automation and Safety

E3X-HD41 2M
E3X-HD41 2M

Omron Automation and Safety

FX-502
FX-502

Panasonic Industrial Automation Sales

ASTC0000
ASTC0000

Red Lion Controls

E3X-HD11 2M
E3X-HD11 2M

Omron Automation and Safety

E3NX-MA11
E3NX-MA11

Omron Automation and Safety

ESPICO-ALL
ESPICO-ALL

PalmSens BV

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER