Send an Inquiry

To receive a quote for your project, please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Part Number*
Quantity*
Message
Submit Inventory List

Please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Upload My List
Message

Analog Devices Inc. 5B30-04-MB

Part No.:
5B30-04-MB
Manufacturer:
Analog Devices Inc.
Category:
Sensor, Transducer Amplifiers
Package:
Datasheet:
Aetrix5B30-04-MB.pdf
Description:
PLUG-IN SIGNAL CONDITIONER
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:3,388

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

5B30-04-MB from Analog Devices is a single-channel isolated voltage input signal conditioner that amplifies, filters, protects, and isolates millivolt-level analog signals. It accepts ±10 mV input range, delivers 0 V to +5 V output, provides 1500 Vrms continuous isolation, and features chopper-stabilized amplification with ±1 µV/°C input offset drift-used in industrial temperature monitoring systems with thermocouple front-ends.

For engineers reviewing the 5B30-04-MB datasheet, 5B30-04-MB pinout, 5B30-04-MB application, or 5B30-04-MB equivalent, key selection criteria include its 4 Hz bandwidth, 240 Vrms input protection, hot-swappable 2.27" × 2.32" × 0.595" module form factor, and factory-set zero suppression for expanded-scale measurement of low-level DC signals.

Technical Context

The 5B30-04-MB implements transformer-coupled isolation with proprietary modulation for linear signal transfer and employs a chopper-stabilized input amplifier to achieve ±1 µV/°C input offset drift and ±0.05% span accuracy at +25°C. Its differential floating input eliminates need for field-side grounding.

Internal multi-pole low-pass filtering provides −3 dB cutoff at 4 Hz, delivering 160 dB common-mode rejection at 50/60 Hz with 1 kΩ source imbalance and 60 dB normal-mode rejection. The series output switch enables active-low enable control with logic "0" ≤ +1 V and logic "1" ≥ +2.5 V.

Key Specifications

ParameterValue and Actual Design Meaning
Input Range±10 mV - supports precise measurement of low-level thermocouple or strain gauge outputs
Output Range0 V to +5 V - directly interfaces with standard 5 V ADCs and PLC analog inputs
Isolation Rating1500 Vrms continuous - meets industrial safety requirements for field-to-control-side separation
Accuracy±0.05% span ±10 µV RTI - ensures calibrated precision without recalibration over temperature
Bandwidth4 Hz (−3 dB) - rejects 50/60 Hz power-line interference while preserving slow-varying process signals
Input Protection240 Vrms continuous - prevents damage from accidental AC line contact on field wiring
Temperature Range−25°C to +85°C rated performance - operates reliably in harsh industrial enclosures

Pinout & Package

5B30-04-MB uses a standardized 4-pin screw-terminal interface in a potted 2.27" × 2.32" × 0.595" (57.8 mm × 59.1 mm × 15.1 mm) module package compatible with all 5B Series backplanes.

Pin/TerminalCircuit RoleDesign Meaning
1No ConnectUnused terminal; must remain unconnected per design
2LOW −Inverting input reference; forms differential pair with Pin 3 for floating field-side signal acquisition
3HIGH +Non-inverting input; accepts ±10 mV signal referenced to Pin 2
4No ConnectUnused terminal; must remain unconnected per design

Key Features

FeatureDesign Value
Transformer-based isolation1500 Vrms continuous rating enables safe operation in Class 1, Division 2 hazardous locations
Chopper-stabilized amplifier±1 µV/°C input offset drift ensures stable zero-point over industrial temperature ranges
Multi-pole 4 Hz low-pass filterRejects 50/60 Hz noise without phase distortion for accurate low-frequency signal capture
Hot-swappable module formatAllows field replacement without powering down backplane or disturbing field wiring
Factory-set zero suppressionEnables measurement of small signals superimposed on large DC offsets (e.g., thermocouple cold-junction compensation)

Applications

Industrial Temperature MonitoringProcess Pressure Transmitter Interface

Use Scenario: Measuring J/K-type thermocouple outputs in refinery control cabinets where ambient temperature swings from −25°C to +70°C.

IC Role / Device Role / Timing Role: Signal conditioner providing isolation, amplification, and 4 Hz filtering before feeding 0–5 V to PLC analog input card.

Use Value: Eliminates ground loops and 60 Hz pickup while maintaining ±0.05% span accuracy across operating temperature range.

Use Scenario: Conditioning mV-output bridge sensors from differential pressure transmitters in water treatment plants.

IC Role / Device Role / Timing Role: Isolating and scaling ±10 mV sensor output to 0–5 V for data acquisition system with shared ground references.

Use Value: 240 Vrms input protection prevents field-wiring fault damage; hot-swap capability enables maintenance without system shutdown.

Rotational Speed Sensing (Tachometer)Strain Gauge Load Cell Interface

Use Scenario: Converting low-amplitude AC-coupled tachometer pulses from turbine shafts into clean DC level for speed feedback control.

IC Role / Device Role / Timing Role: DC-coupled signal conditioner converting bipolar mV pulses to unipolar 0–5 V with precise zero-reference stability.

Use Value: Chopper stabilization and 4 Hz filtering suppress vibration-induced noise while preserving low-speed resolution.

Use Scenario: Interfacing quarter-bridge strain gauges in structural health monitoring systems exposed to EMI-rich environments.

IC Role / Device Role / Timing Role: Providing 160 dB CMR and RFI immunity to reject noise from nearby VFDs and radio transmitters.

Use Value: EN50082-1/EN50081-2 compliance ensures <0.1% full-scale error under 10 V/m, 1 GHz RF fields.

Equivalent & Alternatives

The following parts are listed as comparable options for similar isolated voltage input conditioning applications.

Alternative PartTechnical DifferenceApplication DifferenceSelection Advice
5B30-04Same electrical specs but lacks MB suffix indicating mounting bracket hardwareIdentical signal conditioning function; differs only in mechanical mounting provisionSelect 5B30-04-MB when panel-mounting with bracket is required; otherwise 5B30-04 suffices
AD210BNSingle-ended input, 1000 Vrms isolation, ±0.1% accuracy, no built-in 4 Hz filterRequires external filtering for 50/60 Hz rejection; lower isolation rating limits hazardous-area useChoose AD210BN only if higher bandwidth (>1 kHz) is needed and 1500 Vrms isolation is not mandated

Compared with 5B30-04-MB, the 5B30-04 offers identical signal conditioning performance but omits the mounting bracket, while AD210BN trades isolation strength and integrated filtering for wider bandwidth-making 5B30-04-MB optimal for safety-critical, noise-prone industrial analog input stages.

Availability

5B30-04-MB is available at Aetrix Electronics and suitable for industrial temperature monitoring, process pressure transmitter interfacing, and rotational speed sensing requiring stable component supply, long-term lifecycle support, and FM/CSA-certified hazardous-area compatibility.

Supply support for 5B30-04-MB includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

Analog Devices is a global leader in high-performance analog, mixed-signal, and digital signal processing semiconductors, serving industrial, automotive, communications, and healthcare markets since 1965.

The 5B Series was designed specifically for rugged industrial signal conditioning-delivering transformer-isolated, hot-swappable, potted modules that replace custom-built isolation solutions in PLC, DCS, and data acquisition systems.

FAQ

What is the input impedance of the 5B30-04-MB when powered on?

The 5B30-04-MB has a powered-on input resistance of 5 MΩ, enabling accurate measurement of high-impedance millivolt sources such as thermocouples and unbuffered bridge sensors without loading errors. This value is specified in the official Analog Devices 5B30/5B31 datasheet Rev. 0, Page 4. The 5B30-04-MB maintains this impedance across its full −25°C to +85°C operating range.

Does the 5B30-04-MB require external power supply decoupling?

Yes, the 5B30-04-MB requires a clean +5 V ±5% supply with local 0.1 µF ceramic and 10 µF tantalum capacitors placed within 1 inch of its power pins. This is necessary to maintain its specified 0.2 µVrms input noise and prevent switching artifacts from affecting the chopper-stabilized amplifier. The 5B30-04-MB draws 30 mA typical, and improper decoupling degrades its 160 dB common-mode rejection.

Can the 5B30-04-MB be used with thermocouple types other than J and K?

The 5B30-04-MB itself does not perform cold-junction compensation and is not thermocouple-specific-it conditions any ±10 mV DC signal. However, when paired with 5B Series backplanes containing cold-junction sensors (e.g., 5B37), it supports J, K, T, E, R, S, N, and B thermocouples. The 5B30-04-MB's role remains fixed: amplifying, isolating, and filtering the mV output prior to CJC processing.

What is the maximum allowable common-mode voltage between input and output grounds for the 5B30-04-MB?

The 5B30-04-MB supports up to 1500 Vrms continuous common-mode voltage between field-side input terminals and computer-side output/power grounds. This rating is certified per ANSI/IEEE C37.90.1-1989 transient standards and enables safe deployment in grounded-field industrial environments where ground potential differences exceed hundreds of volts. The 5B30-04-MB maintains this rating across its full temperature range.

Is the output enable function of the 5B30-04-MB internally terminated?

No, the 5B30-04-MB output enable pin is not internally terminated and requires explicit logic-level control: an active-low signal ≤ +1 V turns the output switch ON, while ≥ +2.5 V disables it. If always-enabled operation is desired, the enable input must be grounded to power common-this is explicitly required per the datasheet and cannot rely on internal pull-down. Leaving it floating may cause undefined output behavior.

5B30-04-MB Specifications

Product attributes
Attribute value
Manufacturer:
Analog Devices Inc.
Series:
5B30
Packaging:
Bulk
Product Status:
Active
Amplifier Type:
General Purpose
Voltage - Supply:
4.75V ~ 5.25V
Output Type:
Analog
Current - Supply:
30 mA
Operating Temperature:
-40°C ~ 85°C
Mounting Type:
Surface Mount

5B30-04-MB FAQ

1.How can I place an order for 5B30-04-MB through Aetrix?

Please submit a Request for Quotation (RFQ) for 5B30-04-MB on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for 5B30-04-MB reliable?

The price and inventory of 5B30-04-MB are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for 5B30-04-MB is usually 5 days.

3.What payment methods are accepted for 5B30-04-MB?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for 5B30-04-MB transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for 5B30-04-MB?

5B30-04-MB orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your 5B30-04-MB order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for 5B30-04-MB?

For technical support, including 5B30-04-MB datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your 5B30-04-MB requirements.

6.How does Aetrix verify that 5B30-04-MB is sourced from the original manufacturer or authorized distributors?

All 5B30-04-MB products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that 5B30-04-MB meets industry standards.

7.What is the process for return or replacement of 5B30-04-MB?

All 5B30-04-MB units undergo pre-shipment inspection (PSI). If there is an issue with 5B30-04-MB, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The 5B30-04-MB part is unused and in its original packaging.

Return procedure for 5B30-04-MB:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

5B30-04-MB Tags

  • 5B30-04-MB
  • 5B30-04-MB PDF
  • 5B30-04-MB Datasheet
  • 5B30-04-MB Specifications
  • 5B30-04-MB Images
  • Analog Devices Inc.
  • Analog Devices Inc. 5B30-04-MB
  • Buy 5B30-04-MB
  • 5B30-04-MB Price
  • 5B30-04-MB Distributor
  • 5B30-04-MB Supplier
  • 5B30-04-MB Wholesale
Related Products
SEN-13879
SEN-13879

SparkFun Electronics

GA-311
GA-311

Panasonic Industrial Automation Sales

E32-T11N 2M
E32-T11N 2M

Omron Automation and Safety

FX-501P
FX-501P

Panasonic Industrial Automation Sales

FX-501
FX-501

Panasonic Industrial Automation Sales

E3X-HD44
E3X-HD44

Omron Automation and Safety

E3X-HD41 2M
E3X-HD41 2M

Omron Automation and Safety

FX-502
FX-502

Panasonic Industrial Automation Sales

ASTC0000
ASTC0000

Red Lion Controls

E3X-HD11 2M
E3X-HD11 2M

Omron Automation and Safety

E3NX-MA11
E3NX-MA11

Omron Automation and Safety

ESPICO-ALL
ESPICO-ALL

PalmSens BV

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER