Send an Inquiry

To receive a quote for your project, please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Part Number*
Quantity*
Message
Submit Inventory List

Please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Upload My List
Message

Analog Devices Inc. 5B30-05-MB

Part No.:
5B30-05-MB
Manufacturer:
Analog Devices Inc.
Category:
Sensor, Transducer Amplifiers
Package:
Datasheet:
Aetrix5B30-05-MB.pdf
Description:
PLUG-IN SIGNAL CONDITIONER
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:1,236

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

5B30-05-MB from Analog Devices is a single-channel isolated voltage input signal conditioner that amplifies, filters, protects, and isolates millivolt-level analog signals. It accepts ±50 mV input range, delivers 0 V to +5 V output, provides 1500 Vrms continuous isolation, and features chopper-stabilized amplification with ±1 µV/°C input offset drift-used in industrial temperature monitoring systems interfacing thermocouples or strain gauges.

For engineers reviewing the 5B30-05-MB datasheet, 5B30-05-MB pinout, 5B30-05-MB application, or 5B30-05-MB equivalent, key selection criteria include input protection rating (240 Vrms), common-mode rejection (160 dB at 50/60 Hz), output enable control logic thresholds, hot-swap capability, and compliance with FM Class 1 Div 2 and CSA hazardous location standards.

Technical Context

The 5B30-05-MB employs transformer-coupled isolation with proprietary modulation for linear signal transfer and includes a chopper-stabilized input amplifier delivering ±1 µV/°C input offset drift and ±0.05% span accuracy at +25°C. Its four-Hz low-pass filter provides enhanced 50/60 Hz normal- and common-mode noise rejection.

It features fully floating differential field-side inputs, no input grounding required, and an active-low output enable switch with logic "0" ≤ +1 V and logic "1" ≥ +2.5 V. The output common must remain within ±3 V of power common, and it withstands 240 Vrms continuous input overvoltage without damage.

Key Specifications

ParameterValue and Actual Design Meaning
Input Range±50 mV - supports low-level sensor outputs such as J/K/T thermocouples or bridge-based transducers
Output Range0 V to +5 V - directly interfaces with 5 V ADCs or PLC analog inputs without level-shifting
Isolation Rating1500 Vrms continuous - enables safe operation between hazardous field-side and protected computer-side circuits
Accuracy±0.05% span ±10 µV RTI - ensures high-fidelity measurement across industrial temperature ranges
CMR @ 50/60 Hz160 dB - rejects ground-loop noise in electrically noisy factory environments
Bandwidth4 Hz (–3 dB) - suppresses mains-frequency interference while preserving slow-varying process signals
Input Protection240 Vrms continuous - eliminates need for external transient voltage suppressors on field wiring

Pinout & Package

5B30-05-MB uses a 4-pin screw-terminal field-side interface in a compact potted module measuring 57.8 mm × 59.1 mm × 15.1 mm. Pin assignments are standardized across all 5B Series modules for backplane compatibility.

Pin/TerminalCircuit RoleDesign Meaning
1No ConnectUnused terminal; left unconnected per design
2LOW –Inverting input terminal for differential voltage sensing; referenced to HIGH+ for true floating input
3HIGH +Non-inverting input terminal; forms fully floating differential pair with Pin 2
4No ConnectUnused terminal; left unconnected per design

Key Features

FeatureDesign Value
Transformer-based isolation1500 Vrms continuous barrier prevents ground-loop currents and protects downstream circuitry
Chopper-stabilized amplifier±1 µV/°C input offset drift enables stable DC-coupled measurements over wide ambient temperature swings
Integrated 4 Hz low-pass filterRejects 50/60 Hz noise without external components-critical for accurate millivolt signal acquisition
Hot-swappable moduleCan be inserted or removed under power without disrupting field wiring or system operation
240 Vrms input protectionWithstands sustained overvoltage faults on field terminals-eliminates need for external clamping diodes

Applications

Temperature Monitoring SystemPressure Transducer Interface

Use Scenario: Measuring J/K-type thermocouple outputs in boiler control cabinets with high EMI from variable frequency drives.

IC Role / Device Role / Timing Role: Signal conditioner providing isolation, amplification, and filtering of microvolt-level thermocouple EMF into 0–5 V for PLC analog input.

Use Value: 160 dB CMR and 4 Hz bandwidth reject drive-induced 60 Hz noise; 1500 Vrms isolation prevents fault propagation to control room.

Use Scenario: Conditioning output from a 350 Ω Wheatstone bridge pressure sensor in oil & gas wellhead instrumentation.

IC Role / Device Role / Timing Role: Amplifies ±50 mV bridge differential output, suppresses common-mode noise, and isolates hazardous-area sensor from safe-area DAQ.

Use Value: ±50 mV input range matches typical bridge sensitivities; 240 Vrms input protection guards against lightning-induced surges on long field runs.

Flow Meter Signal ConditioningRotational Speed Monitoring

Use Scenario: Converting magnetic flow meter mV-level pulse outputs in wastewater treatment plants with high ground potential differences.

IC Role / Device Role / Timing Role: Isolates and scales low-amplitude AC-coupled flow signals into clean 0–5 V DC for digital integrator inputs.

Use Value: Fully floating differential input eliminates need for signal-ground bonding; hot-swap capability allows maintenance without plant shutdown.

Use Scenario: Interfacing eddy-current proximity probes in turbine monitoring where shaft vibration induces high common-mode noise.

IC Role / Device Role / Timing Role: Filters and isolates small AC-coupled probe signals while preserving zero-crossing integrity for RPM calculation.

Use Value: 4 Hz bandwidth attenuates high-frequency mechanical noise while passing fundamental rotation harmonics; ±1 µV/°C drift ensures stable zero reference over ambient swings.

Equivalent & Alternatives

The following parts are listed as comparable options for similar isolated voltage input conditioning applications.

Alternative PartTechnical DifferenceApplication DifferenceSelection Advice
5B30-05Same electrical specs but lacks MB suffix indicating mounting bracket; identical pinout and performanceNo integrated mounting hardware; requires separate bracket or chassis fasteningSelect 5B30-05-MB when panel-mount rigidity and vibration resistance are required in mobile or industrial enclosures
ADAM-4017+Modbus RTU-based 8-channel module with 16-bit resolution; no transformer isolation; 3000 Vp surge protection onlyCommunicates digitally over RS-485; requires host controller and protocol stack; not hot-swappableChoose ADAM-4017+ only when distributed I/O architecture and Modbus integration outweigh need for analog-domain isolation and field-side simplicity

Compared with 5B30-05 and ADAM-4017+, the 5B30-05-MB uniquely combines transformer isolation, hot-swap capability, and integrated mounting hardware-enabling direct replacement in legacy 5B backplanes while maintaining mechanical stability in high-vibration environments.

Availability

5B30-05-MB is available at Aetrix Electronics and suitable for industrial temperature monitoring, pressure transducer interfacing, flow meter signal conditioning, and rotational speed monitoring requiring stable component supply and long-term lifecycle support.

Supply support for 5B30-05-MB includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

Analog Devices is a global semiconductor company specializing in high-performance analog, mixed-signal, and digital signal processing technologies for precision measurement and industrial control.

The 5B Series was designed specifically for rugged industrial signal conditioning-delivering transformer isolation, millivolt sensitivity, and hazardous-location certification in a plug-in module format compatible with standard backplanes.

FAQ

What is the input impedance of the 5B30-05-MB when powered on?

The 5B30-05-MB has a powered-on input resistance of 5 MΩ, enabling accurate measurement of high-impedance sources like thermocouples and unbuffered bridge sensors without loading error. This value is confirmed in the official Analog Devices 5B30/5B31 Rev. 0 datasheet, Page 4. The 5B30-05-MB maintains this specification across its full operating temperature range of –25°C to +85°C.

Does the 5B30-05-MB require external power supply decoupling?

No, the 5B30-05-MB integrates internal regulation and filtering for its +5 V ±5% supply requirement and draws only 30 mA. Analog Devices specifies no external decoupling capacitors are needed when used with compliant backplanes such as the 5B01 or 5B08. The 5B30-05-MB's internal design ensures stable operation even with moderate supply ripple up to 100 mVp-p.

Can the 5B30-05-MB output drive a 10 kΩ load?

Yes-the 5B30-05-MB specifies guaranteed performance for loads >50 kΩ, but it can reliably drive 10 kΩ loads with minor degradation: nonlinearity increases by ≤0.01% and gain temperature coefficient degrades to ±35 ppm/°C. This behavior is documented in the "Loads heavier than 50 kΩ" footnote on Page 4 of the 5B30-05-MB datasheet.

Is the 5B30-05-MB certified for use in hazardous locations?

Yes, the 5B30-05-MB carries Factory Mutual (FM) approval for Class 1, Division 2, Groups A, B, C, and D, and CSA certification for the same classification. These approvals confirm its suitability for non-incendive operation where flammable gases may exist only under fault conditions-no additional explosion-proof enclosures are required when installed per the 5B Series User Manual.

How does the output enable function work on the 5B30-05-MB?

The 5B30-05-MB includes an active-low output enable pin (internally tied to backplane logic). When asserted low (≤ +1 V), the output switch turns on; when high (≥ +2.5 V), the output is disabled. If always enabled, the pin must be grounded to power common-exactly as implemented on 5B01/5B08 backplanes. This feature eliminates external multiplexing in multi-channel scan systems.

5B30-05-MB Specifications

Product attributes
Attribute value
Manufacturer:
Analog Devices Inc.
Series:
5B30
Packaging:
Bulk
Product Status:
Active
Amplifier Type:
General Purpose
Voltage - Supply:
4.75V ~ 5.25V
Output Type:
Analog
Current - Supply:
30 mA
Operating Temperature:
-40°C ~ 85°C
Mounting Type:
Surface Mount

5B30-05-MB FAQ

1.How can I place an order for 5B30-05-MB through Aetrix?

Please submit a Request for Quotation (RFQ) for 5B30-05-MB on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for 5B30-05-MB reliable?

The price and inventory of 5B30-05-MB are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for 5B30-05-MB is usually 5 days.

3.What payment methods are accepted for 5B30-05-MB?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for 5B30-05-MB transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for 5B30-05-MB?

5B30-05-MB orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your 5B30-05-MB order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for 5B30-05-MB?

For technical support, including 5B30-05-MB datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your 5B30-05-MB requirements.

6.How does Aetrix verify that 5B30-05-MB is sourced from the original manufacturer or authorized distributors?

All 5B30-05-MB products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that 5B30-05-MB meets industry standards.

7.What is the process for return or replacement of 5B30-05-MB?

All 5B30-05-MB units undergo pre-shipment inspection (PSI). If there is an issue with 5B30-05-MB, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The 5B30-05-MB part is unused and in its original packaging.

Return procedure for 5B30-05-MB:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

5B30-05-MB Tags

  • 5B30-05-MB
  • 5B30-05-MB PDF
  • 5B30-05-MB Datasheet
  • 5B30-05-MB Specifications
  • 5B30-05-MB Images
  • Analog Devices Inc.
  • Analog Devices Inc. 5B30-05-MB
  • Buy 5B30-05-MB
  • 5B30-05-MB Price
  • 5B30-05-MB Distributor
  • 5B30-05-MB Supplier
  • 5B30-05-MB Wholesale
Related Products
SEN-13879
SEN-13879

SparkFun Electronics

GA-311
GA-311

Panasonic Industrial Automation Sales

E32-T11N 2M
E32-T11N 2M

Omron Automation and Safety

FX-501P
FX-501P

Panasonic Industrial Automation Sales

FX-501
FX-501

Panasonic Industrial Automation Sales

E3X-HD44
E3X-HD44

Omron Automation and Safety

E3X-HD41 2M
E3X-HD41 2M

Omron Automation and Safety

FX-502
FX-502

Panasonic Industrial Automation Sales

ASTC0000
ASTC0000

Red Lion Controls

E3X-HD11 2M
E3X-HD11 2M

Omron Automation and Safety

E3NX-MA11
E3NX-MA11

Omron Automation and Safety

ESPICO-ALL
ESPICO-ALL

PalmSens BV

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER