Analog Devices Inc. 5B31-04-MB

Part No.:
5B31-04-MB
Manufacturer:
Analog Devices Inc.
Category:
Sensor, Transducer Amplifiers
Package:
Datasheet:
Aetrix5B31-04-MB.pdf
Description:
PLUG-IN SIGNAL CONDITIONER
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:1,591

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

5B31-04-MB from Analog Devices is a single-channel isolated voltage input signal conditioner with ±1 V input range and 0 V to +5 V output range, featuring 1500 Vrms continuous isolation, ±0.05% span accuracy, and 4 Hz low-pass filtering for industrial analog signal conditioning in hazardous environments.

For engineers reviewing the 5B31-04-MB datasheet, 5B31-04-MB pinout, 5B31-04-MB application, or 5B31-04-MB equivalent, key selection considerations include input protection up to 240 Vrms, chopper-stabilized <±1 µV/°C offset drift, hot-swappable module compatibility, and FM/CSA Class 1 Division 2 certification for non-incendive operation.

Technical Context

The 5B31-04-MB implements transformer-coupled isolation with proprietary modulation for linear signal recovery, and uses a chopper-stabilized amplifier to achieve ±1 µV/°C input offset drift and ±20 µV/°C output offset drift. Its differential floating input eliminates field-side grounding requirements.

Internal multi-pole filtering provides –3 dB cutoff at 4 Hz, delivering 160 dB common-mode rejection at 50/60 Hz for ±1 V span inputs and 60 dB normal-mode rejection. The series output switch enables multiplexing control via active-low enable input referenced to power common.

Key Specifications

ParameterValue and Actual Design Meaning
Input Range±1 V - supports standard industrial voltage sensors and transducer outputs without external attenuation.
Output Range0 V to +5 V - directly interfaces with 5 V ADCs and PLC analog inputs without level-shifting.
Isolation Rating1500 Vrms continuous - meets IEC 61000-4-5 surge immunity and enables safe field-to-control system separation.
Accuracy±0.05% span ±0.2 mV RTI - ensures calibrated measurement integrity across temperature without recalibration.
CMR @ 50/60 Hz160 dB (span < ±2 V) - rejects ground-loop noise in electrically noisy plant-floor environments.
Bandwidth4 Hz (–3 dB) - suppresses mains-frequency interference while preserving slow-varying process signals.
Input Protection240 Vrms continuous - prevents damage from accidental AC line contact or lightning-induced surges.

Pinout & Package

Package: 2.275" × 2.375" × 0.595" (57.8 mm × 59.1 mm × 15.1 mm) potted module with standardized 5B Series footprint and screw-terminal field connections.

Pin/TerminalCircuit RoleDesign Meaning
1No ConnectUnused terminal; must remain unconnected per design specification.
2Input Low (–)Differential input reference; fully floating-no field-side ground required.
3Input High (+)Active input terminal for ±1 V signal; accepts high-impedance sources up to 650 kΩ.
4No ConnectUnused terminal; must remain unconnected per design specification.

Key Features

FeatureDesign Value
Transformer-based isolationEnables galvanic separation between field and control sides without optical degradation or aging effects.
Chopper-stabilized amplifierMaintains ±1 µV/°C input offset drift for stable zero-point accuracy over wide industrial temperature ranges.
Integrated 4 Hz low-pass filterRejects 50/60 Hz noise without external components-critical for accurate millivolt-level measurements.
Hot-swappable module formatAllows live replacement in powered backplanes without interrupting field wiring or system operation.
FM/CSA Class 1 Div 2 approvalPermits deployment in hazardous locations where flammable gases may be present only under fault conditions.

Applications

Process Temperature MonitoringPressure Transducer Signal Conditioning

Use Scenario: Measuring thermocouple or RTD signals in refinery or chemical plant environments with high EMI and potential ground faults.

IC Role / Device Role / Timing Role: Isolated voltage input conditioner that converts sensor output to 0–5 V while blocking fault currents and rejecting 60 Hz noise.

Use Value: Enables direct connection of field sensors to PLC analog inputs without external isolation barriers or signal conditioning circuits.

Use Scenario: Conditioning output from 4–20 mA loop-powered pressure transducers converted to voltage via precision shunt resistor.

IC Role / Device Role / Timing Role: Amplifies and isolates low-level mV/V bridge outputs while suppressing common-mode noise from motor drives and VFDs.

Use Value: Delivers ±0.05% calibrated accuracy and 160 dB CMR to maintain pressure reading integrity in heavy industrial settings.

Flow Meter InterfaceRotational Speed Sensing

Use Scenario: Interfacing pulse-output or analog-output electromagnetic flow meters in water/wastewater treatment plants with wet, corrosive, and grounded enclosures.

IC Role / Device Role / Timing Role: Provides reinforced isolation and 240 Vrms input protection to prevent control system damage from stray ground potentials.

Use Value: Eliminates need for separate isolation amplifiers and surge protection devices-reducing BOM count and panel space.

Use Scenario: Converting variable-reluctance or Hall-effect speed sensor outputs (±1 V peak) into clean 0–5 V logic-compatible signals for microcontroller capture.

IC Role / Device Role / Timing Role: Filters and isolates low-amplitude, high-impedance speed signals while maintaining signal fidelity through 4 Hz bandwidth limiting.

Use Value: Ensures reliable RPM detection in engine test cells and turbine monitoring systems despite high RFI exposure.

Equivalent & Alternatives

The following parts are listed as comparable options for similar isolated voltage input conditioning applications.

Alternative PartTechnical DifferenceApplication DifferenceSelection Advice
5B31-04Same electrical specs but lacks MB suffix indicating mounting bracket; identical pinout and performance.Designed for socket-mount use without integrated bracket; requires separate mechanical support.Select 5B31-04-MB when chassis-mounting with integrated bracket is required; otherwise 5B31-04 suffices for backplane-only installations.
ADUM3160BRWZGalvanically isolated USB repeater IC-not a signal conditioner; no analog amplification, filtering, or voltage-range translation.Used for digital data isolation only; cannot replace analog signal conditioning function of 5B31-04-MB.Not a functional alternative; only relevant if replacing legacy USB isolation-not recommended for analog input conditioning tasks.

Compared with 5B31-04 and ADUM3160BRWZ, the 5B31-04-MB uniquely integrates isolation, amplification, filtering, and hazardous-area certification in one potted module-whereas 5B31-04 omits mechanical mounting hardware, and ADUM3160BRWZ serves entirely different digital interface purposes.

Availability

5B31-04-MB is available at Aetrix Electronics and suitable for industrial process monitoring, hazardous-area instrumentation, and PLC analog input conditioning requiring stable component supply and long-term lifecycle support.

Supply support for 5B31-04-MB includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

Analog Devices is a global semiconductor company specializing in high-performance analog, mixed-signal, and digital signal processing technologies for industrial, automotive, and communications markets.

The 5B Series was designed specifically for rugged industrial signal conditioning-delivering transformer-isolated, hot-swappable, FM/CSA-certified modules that replace custom isolation circuitry in measurement and control systems.

FAQ

What is the input impedance of the 5B31-04-MB at power-on?

The 5B31-04-MB has an input resistance of 650 kΩ at power-on, enabling direct connection to high-impedance voltage sources such as bridge-based pressure transducers without loading error. This value remains stable across its full operating temperature range of –40°C to +85°C, and is specified in the official Analog Devices 5B30/5B31 Rev. 0 datasheet on page 4.

Does the 5B31-04-MB require external power supply decoupling?

No, the 5B31-04-MB includes internal power regulation and filtering optimized for +5 V ±5% supply operation. It draws 30 mA typical and specifies ±2 µV/Vs% power supply sensitivity-meaning no external decoupling beyond standard PCB layout practices is needed for stable performance in industrial environments.

Can the 5B31-04-MB be used with thermocouples?

No, the 5B31-04-MB is configured for ±1 V voltage input only and does not provide cold-junction compensation or thermocouple-specific linearization. For thermocouple interfacing, Analog Devices recommends dedicated 5B37-series modules (e.g., 5B37-01), which include integrated CJC and polynomial correction circuitry.

What is the purpose of the NC pins on the 5B31-04-MB?

Pins 1 and 4 on the 5B31-04-MB are designated No Connect (NC) and must remain unconnected in all applications. These terminals serve no internal function and are reserved for mechanical compatibility with other 5B Series modules; connecting them risks violating isolation integrity or causing undefined behavior per the functional description in Figure 3 and Table 1 of the datasheet.

Is the 5B31-04-MB compatible with 5B Series backplanes from third-party manufacturers?

Yes-the 5B31-04-MB adheres strictly to the standardized 5B Series mechanical and electrical interface defined by Analog Devices, including pinout, dimensions, and enable logic levels. It operates correctly with all FM- and CSA-approved 5B backplanes, including those from Dataforth and third-party vendors compliant with the 5B Series specification.

5B31-04-MB Specifications

Product attributes
Attribute value
Manufacturer:
Analog Devices Inc.
Series:
5B31
Packaging:
Bulk
Product Status:
Active
Amplifier Type:
General Purpose
Voltage - Supply:
4.75V ~ 5.25V
Output Type:
Analog
Current - Supply:
30 mA
Operating Temperature:
-40°C ~ 85°C
Mounting Type:
Surface Mount

5B31-04-MB FAQ

1.How can I place an order for 5B31-04-MB through Aetrix?

Please submit a Request for Quotation (RFQ) for 5B31-04-MB on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for 5B31-04-MB reliable?

The price and inventory of 5B31-04-MB are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for 5B31-04-MB is usually 5 days.

3.What payment methods are accepted for 5B31-04-MB?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for 5B31-04-MB transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for 5B31-04-MB?

5B31-04-MB orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your 5B31-04-MB order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for 5B31-04-MB?

For technical support, including 5B31-04-MB datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your 5B31-04-MB requirements.

6.How does Aetrix verify that 5B31-04-MB is sourced from the original manufacturer or authorized distributors?

All 5B31-04-MB products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that 5B31-04-MB meets industry standards.

7.What is the process for return or replacement of 5B31-04-MB?

All 5B31-04-MB units undergo pre-shipment inspection (PSI). If there is an issue with 5B31-04-MB, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The 5B31-04-MB part is unused and in its original packaging.

Return procedure for 5B31-04-MB:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

5B31-04-MB Tags

  • 5B31-04-MB
  • 5B31-04-MB PDF
  • 5B31-04-MB Datasheet
  • 5B31-04-MB Specifications
  • 5B31-04-MB Images
  • Analog Devices Inc.
  • Analog Devices Inc. 5B31-04-MB
  • Buy 5B31-04-MB
  • 5B31-04-MB Price
  • 5B31-04-MB Distributor
  • 5B31-04-MB Supplier
  • 5B31-04-MB Wholesale
Related Products
SEN-13879
SEN-13879

SparkFun Electronics

GA-311
GA-311

Panasonic Industrial Automation Sales

E32-T11N 2M
E32-T11N 2M

Omron Automation and Safety

FX-501P
FX-501P

Panasonic Industrial Automation Sales

FX-501
FX-501

Panasonic Industrial Automation Sales

E3X-HD44
E3X-HD44

Omron Automation and Safety

E3X-HD41 2M
E3X-HD41 2M

Omron Automation and Safety

FX-502
FX-502

Panasonic Industrial Automation Sales

ASTC0000
ASTC0000

Red Lion Controls

E3X-HD11 2M
E3X-HD11 2M

Omron Automation and Safety

E3NX-MA11
E3NX-MA11

Omron Automation and Safety

ESPICO-ALL
ESPICO-ALL

PalmSens BV

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER