Analog Devices Inc. 5B34-02-CY
- Part No.:
- 5B34-02-CY
- Manufacturer:
- Analog Devices Inc.
- Category:
- Sensor, Transducer Amplifiers
- Package:
- Datasheet:
-
5B34-02-CY.pdf
- Description:
- ISOLATED LINEARIZED RTD INPUT
- Quantity:
- Payment:

- Shipping:

Inventory:4,177
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
5B34-02-CY from Analog Devices is an isolated linearized RTD input signal conditioner for 2- and 3-wire platinum RTDs, providing 0 V to +5 V output, ±0.13°C accuracy over 0°C to +100°C, 1500 Vrms isolation, and 240 Vrms input protection-used in industrial temperature monitoring systems with hazardous-area compliance.
For engineers reviewing the 5B34-02-CY datasheet, 5B34-02-CY pinout, 5B34-02-CY application, or 5B34-02-CY equivalent, key selection considerations include its fixed 0°C–100°C input range, laser-trimmed linearization for Pt-100 (α = 0.00385), chopper-stabilized <1 µV/°C drift, 4 Hz bandwidth, and hot-swappable 5B-series mechanical compatibility.
Technical Context
The 5B34-02-CY implements transformer-coupled isolation with proprietary modulation for stable linear signal transfer, using dual matched current sources (0.25 mA) to cancel lead resistance in 3-wire RTDs and laser-trimmed feedback linearization for Pt-100 conformity error ≤±0.05% span.
Its differential chopper-stabilized amplifier delivers ±0.02°C/°C input offset drift and ±20 µV/°C output offset drift, while internal multi-pole low-pass filtering achieves 160 dB CMR at 50/60 Hz and 4 Hz –3 dB bandwidth-optimized for noisy industrial environments where high common-mode rejection and low self-heating (<0.25 mA excitation) are critical.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Input Range | 0°C to +100°C for 100 Ω platinum RTD (α = 0.00385) |
| Output Range | 0 V to +5 V, compatible with standard ADC inputs and PLC analog modules |
| Accuracy | ±0.13°C total error over full range, including linearity, hysteresis, and repeatability |
| Isolation Rating | 1500 Vrms continuous input-to-output isolation, enabling safe interface between field and control sides |
| Bandwidth | 4 Hz –3 dB cutoff, rejecting 50/60 Hz power-line interference and high-frequency noise |
| Excitation Current | 0.25 mA constant-current source, minimizing RTD self-heating to preserve measurement fidelity |
| Lead Resistance Rejection | ±0.02°C/Ω for 2- or 3-wire configurations, enabling accurate compensation without 4-wire wiring |
Pinout & Package
Package: 2.275" × 2.375" × 0.595" (57.8 mm × 59.1 mm × 15.1 mm) potted module with standardized 5B-series footprint and screw-terminal field connections.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 | NC | No connection; unused pin per functional design |
| 2 | LO | Low-side RTD terminal; connects to RTD return/low leg in 2-/3-wire configuration |
| 3 | HI | High-side RTD terminal; carries excitation current and senses RTD voltage drop |
| 4 | RETURN | Output reference common; must be held within ±3 V of power common for valid operation |
Key Features
| Feature | Design Value |
|---|---|
| Laser-trimmed linearization | Eliminates external software correction for Pt-100 across 0°C–100°C, reducing system calibration burden |
| Dual current-source lead cancellation | Enables accurate 3-wire RTD measurement without manual lead-resistance subtraction |
| Chopper-stabilized amplifier | Delivers <1 µV/°C input offset drift, ensuring long-term stability in unregulated ambient conditions |
| Transformer-based isolation | Provides galvanic separation meeting FM Class 1 Div 2 and CSA approvals for hazardous locations |
| Hot-swappable mechanical format | Allows live replacement in 5B backplanes without powering down system or disturbing field wiring |
Applications
| Process Temperature Monitoring | PLC Analog Input Conditioning |
|---|---|
Use Scenario: Continuous monitoring of reactor vessel temperature in chemical processing plants with explosive gas risk. IC Role / Device Role / Timing Role: Isolated RTD signal conditioner converting Pt-100 resistance to 0–5 V for downstream DCS acquisition. Use Value: Enables direct integration into FM/CSA-certified control cabinets without additional barrier or isolation hardware. | Use Scenario: Retrofitting legacy PLCs with analog inputs lacking built-in RTD linearization or isolation. IC Role / Device Role / Timing Role: Standalone front-end module providing calibrated, filtered, and isolated voltage output for PLC AI channels. Use Value: Eliminates need for custom firmware linearization and reduces susceptibility to ground-loop-induced 50/60 Hz noise. |
| Hazardous Area Sensor Interface | Industrial Data Acquisition Front-End |
Use Scenario: Connecting RTD sensors in oil & gas refinery zones where flammable vapors may exist under fault conditions. IC Role / Device Role / Timing Role: Non-incendive signal conditioner certified for Class 1, Division 2, Groups A–D locations. Use Value: Meets intrinsic safety requirements without requiring explosion-proof enclosures or field barriers. | Use Scenario: High-accuracy temperature logging in environmental test chambers with EMI-rich motor drive environments. IC Role / Device Role / Timing Role: Low-drift, 4 Hz bandwidth conditioner suppressing RFI/EMI up to 1 GHz at 10 V/m field strength. Use Value: Maintains <0.1% FS error under severe electromagnetic interference, per EN50082-1 compliance. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar isolated RTD signal conditioning applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| 5B34-02 | No "CY" suffix; identical electrical specs and pinout, but lacks CSA/FM certification markings required for North American hazardous-area use | Approved only for general industrial use-not rated for Class 1 Div 2 locations | Select 5B34-02-CY when CSA/FM certification is mandatory; otherwise 5B34-02 offers same performance at lower cost |
| ADAM-4017+ | Modbus RTU-based 8-channel RTD input module with onboard microcontroller, no transformer isolation, 1500 Vdc isolation via optocouplers | Requires host communication stack and external power; not hot-swappable or potted | Choose ADAM-4017+ for distributed I/O networks needing Modbus connectivity; choose 5B34-02-CY for plug-in, analog-output, certified isolation |
Compared with 5B34-02 and ADAM-4017+, the 5B34-02-CY uniquely combines factory-certified hazardous-area approval, analog 0–5 V output, hot-swap capability, and transformer-based isolation-making it optimal for safety-critical, analog-centric control systems where certification and mechanical interoperability are non-negotiable.
Availability
5B34-02-CY is available at Aetrix Electronics and suitable for industrial temperature monitoring, hazardous-area sensor interfacing, and PLC analog input conditioning requiring stable component supply and long-term lifecycle support.
Supply support for 5B34-02-CY includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Analog Devices is a global semiconductor leader specializing in high-performance analog, mixed-signal, and digital signal processing technologies for precision measurement and industrial control.
The 5B Series was designed specifically for rugged industrial signal conditioning-delivering transformer-isolated, linearized, and protected analog interfaces for RTDs, thermocouples, and voltage/current signals in hazardous and electrically noisy environments.
FAQ
What is the exact RTD type and alpha coefficient supported by the 5B34-02-CY?
The 5B34-02-CY is configured for 100 Ω platinum RTDs with α = 0.00385, covering the 0°C to +100°C range. It does not support other RTD types (e.g., Ni or Cu) or alternate alpha values (e.g., 0.003916) unless custom-trimmed. The "-02" suffix explicitly denotes this Pt-100/0.00385 calibration, and the "CY" suffix confirms CSA/FM certification for that configuration.
Does the 5B34-02-CY require external power supply regulation?
No-the 5B34-02-CY operates from a nominal +5 V dc supply with ±5% tolerance and includes internal regulation. Its power supply sensitivity is specified as ±0.05°C/V for Pt RTDs, meaning output error remains within specification across the full supply range. No external regulator is needed, simplifying system-level power design.
Can the 5B34-02-CY be used with 4-wire RTDs?
No-the 5B34-02-CY supports only 2- and 3-wire RTD configurations. True 4-wire RTD measurements require the dedicated 5B35 model, which provides separate force-and-sense paths. Using a 4-wire RTD with the 5B34-02-CY will result in inaccurate readings due to uncancelled lead resistance and improper excitation routing.
What is the maximum continuous common-mode voltage the 5B34-02-CY can withstand?
The 5B34-02-CY withstands 1500 Vrms continuous common-mode voltage between input and output circuits. This rating is verified per ANSI/IEEE C37.90.1-1989 transient standards and enables safe operation in high-noise plant environments where ground potential differences exceed hundreds of volts.
Is the 5B34-02-CY compatible with all 5B-series backplanes?
Yes-the 5B34-02-CY shares identical mechanical dimensions, pinout, and hot-swap logic with all standard 5B-series modules. It mates seamlessly with 5B01, 5B08, and other FM/CSA-approved backplanes, and requires no firmware or configuration changes when inserted or replaced in-service.
5B34-02-CY Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Analog Devices Inc.
- Series:
- -
- Packaging:
- Bulk
- Product Status:
- Active
- Amplifier Type:
- Analog Output
- Voltage - Supply:
- 4.75V ~ 5.25V
- Output Type:
- Analog
- Current - Supply:
- 30 mA
- Operating Temperature:
- -40°C ~ 85°C
- Mounting Type:
- Surface Mount
5B34-02-CY FAQ
1.How can I place an order for 5B34-02-CY through Aetrix?
Please submit a Request for Quotation (RFQ) for 5B34-02-CY on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for 5B34-02-CY reliable?
The price and inventory of 5B34-02-CY are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for 5B34-02-CY is usually 5 days.
3.What payment methods are accepted for 5B34-02-CY?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for 5B34-02-CY transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for 5B34-02-CY?
5B34-02-CY orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your 5B34-02-CY order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for 5B34-02-CY?
For technical support, including 5B34-02-CY datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your 5B34-02-CY requirements.
6.How does Aetrix verify that 5B34-02-CY is sourced from the original manufacturer or authorized distributors?
All 5B34-02-CY products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that 5B34-02-CY meets industry standards.
7.What is the process for return or replacement of 5B34-02-CY?
All 5B34-02-CY units undergo pre-shipment inspection (PSI). If there is an issue with 5B34-02-CY, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The 5B34-02-CY part is unused and in its original packaging.
Return procedure for 5B34-02-CY:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
5B34-02-CY Tags

-
SEN-13879
SparkFun Electronics

-
GA-311
Panasonic Industrial Automation Sales

-
E32-T11N 2M
Omron Automation and Safety

-
FX-501P
Panasonic Industrial Automation Sales

-
FX-501
Panasonic Industrial Automation Sales

-
E3X-HD44
Omron Automation and Safety

-
E3X-HD41 2M
Omron Automation and Safety

-
FX-502
Panasonic Industrial Automation Sales

-
ASTC0000
Red Lion Controls

-
E3X-HD11 2M
Omron Automation and Safety

-
E3NX-MA11
Omron Automation and Safety

-
ESPICO-ALL
PalmSens BV
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…