Analog Devices Inc. 5B35-04-NI
- Part No.:
- 5B35-04-NI
- Manufacturer:
- Analog Devices Inc.
- Category:
- Sensor, Transducer Amplifiers
- Package:
- Datasheet:
-
5B35-04-NI.pdf
- Description:
- MODULE
- Quantity:
- Payment:

- Shipping:

Inventory:2,289
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
5B35-04-NI from Analog Devices is a single-channel, isolated, linearized 4-wire RTD input signal conditioner for platinum RTDs (α = 0.00385), supporting 0°C to +600°C range with ±0.78°C accuracy, 0–5 V output, 1500 Vrms input-output isolation, and 4 Hz bandwidth. It delivers precision temperature measurement in hazardous industrial environments requiring nonincendive operation.
For engineers reviewing the 5B35-04-NI datasheet, 5B35-04-NI pinout, 5B35-04-NI application, or 5B35-04-NI equivalent, key selection criteria include its four-wire RTD excitation (0.25 mA), true three-port isolation, chopper-stabilized amplifier (+0.01°C/°C offset drift), 190 dB CMR (180 dB for Model -04), and FM/CSA Class 1 Division 2 certification.
Technical Context
The 5B35-04-NI implements transformer-coupled, three-port isolation (input/output/power) with proprietary modulation/demodulation for linear signal recovery. Its differential input eliminates field-side grounding needs, while a low-drift chopper-stabilized amplifier enables high-accuracy RTD measurement with minimal self-heating error.
It integrates a five-pole Butterworth filter (4 Hz –3 dB bandwidth), delivering 116 dB normal-mode rejection at 60 Hz and 108 dB at 50 Hz. Input protection withstands 240 Vrms continuously, and the series output switch supports active-low enable control with 6 µs selection time.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Input Range | 0°C to +600°C for 100 Ω Pt RTD (α = 0.00385) |
| Output Range | 0 V to +5 V, compatible with standard ADC inputs and PLC analog inputs |
| Accuracy | ±0.78°C total error including conformity, repeatability, and hysteresis |
| Isolation Rating | 1500 Vrms between input/output and input/power; 250 Vrms between output/power |
| Bandwidth | 4 Hz –3 dB, optimized for slow-varying industrial temperature signals |
| RTD Excitation | 0.25 mA constant current, minimizing self-heating error in platinum RTDs |
| CMR @ 50/60 Hz | 180 dB (1 kΩ source imbalance), rejecting ground-loop interference in noisy plants |
Pinout & Package
Package: 2.275" × 2.375" × 0.595" (57.8 mm × 59.1 mm × 15.1 mm) potted module with standardized 5B Series footprint and screw-terminal field connections.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1: –EXC | RTD excitation return | Negative terminal of precision 0.25 mA current source for 4-wire RTD configuration |
| 2: LO | Differential input low | Low-side voltage sense lead; carries no excitation current, eliminating lead-resistance error |
| 3: HI | Differential input high | High-side voltage sense lead; measures RTD voltage drop without excitation current path |
| 4: +EXC | RTD excitation supply | Positive terminal of precision 0.25 mA current source; powers RTD element directly |
Key Features
| Feature | Design Value |
|---|---|
| True three-port isolation | Independent galvanic separation of input, output, and power domains prevents ground loops and enables safe operation in Class 1 Div 2 hazardous areas |
| Four-wire RTD support with low-excitation current | 0.25 mA excitation minimizes self-heating error (<0.00001°C/Ω lead resistance effect) for high-accuracy Pt100 measurements |
| Chopper-stabilized amplifier | +0.01°C/°C input offset drift ensures stable calibration over –40°C to +85°C operating range |
| Integrated 4 Hz filtering | Five-pole Butterworth response rejects 50/60 Hz line noise by ≥108 dB, critical for factory-floor installations |
| Hot-swappable design | Compatible with all 5B Series backplanes; insertion/removal requires no system power-down or rewiring |
Applications
| Industrial Temperature Monitoring | Hazardous Area Process Control |
|---|---|
Use Scenario: Continuous monitoring of reactor vessel temperature in chemical processing plants where ambient temperatures range from –20°C to +70°C. IC Role / Device Role / Timing Role: Isolated RTD signal conditioner converting Pt100 resistance to calibrated 0–5 V analog output for PLC acquisition. Use Value: ±0.78°C accuracy and 1500 Vrms isolation ensure reliable readings despite EMI from nearby VFDs and compliance with FM/CSA Class 1 Div 2 requirements. | Use Scenario: Temperature supervision of fuel storage tanks in oil refineries where flammable vapors may be present under fault conditions. IC Role / Device Role / Timing Role: Nonincendive signal conditioner providing intrinsically safe interface between field RTDs and control room DCS. Use Value: Certified FM/CSA Class 1 Div 2 operation eliminates need for explosion-proof enclosures; 240 Vrms input protection guards against surge events. |
| High-Accuracy Furnace Calibration | Multi-Sensor Industrial Data Acquisition |
Use Scenario: Lab-grade calibration of industrial furnaces using multiple 4-wire Pt100 sensors across 0–600°C range. IC Role / Device Role / Timing Role: Linearized RTD conditioner delivering traceable 0–5 V output with <0.05% span conformity error. Use Value: Conformity error ±0.05% span and <0.003% gain drift/°C enable repeatable calibration without frequent recalibration. | Use Scenario: Modular DAQ system integrating diverse sensor types (RTDs, thermocouples, voltage) on shared 5B Series backplane. IC Role / Device Role / Timing Role: Mix-and-match plug-in module enabling flexible channel configuration without custom PCB design. Use Value: Identical mechanical footprint and pinout allow hot-swapping 5B35-04-NI alongside 5B30, 5B40, or 5B08 modules in same chassis. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar RTD signal conditioning applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| ADAM-4019+ (Advantech) | 8-channel, Ethernet-connected, software-configurable RTD input; no transformer isolation; 3000 Vdc isolation via optocouplers | Designed for distributed remote I/O systems; requires network infrastructure and driver software | Choose when centralized Ethernet-based monitoring is preferred over modular backplane integration |
| ISO5852S (Texas Instruments) | Single-channel, reinforced isolation (5 kVrms), but requires external RTD excitation and linearization circuitry | Targeted at custom-designed isolated analog front-ends; not a complete plug-in solution | Choose when board-level integration and maximum isolation voltage outweigh need for turnkey signal conditioning |
Compared with ADAM-4019+ and ISO5852S, the 5B35-04-NI provides a fully integrated, certified, hot-swappable module with built-in excitation, linearization, filtering, and three-port isolation - eliminating external components and qualification effort required for field-deployable industrial systems.
Availability
5B35-04-NI is available at Aetrix Electronics and suitable for industrial temperature monitoring, hazardous area process control, and high-accuracy furnace calibration requiring stable component supply and long-term lifecycle support.
Supply support for 5B35-04-NI includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Analog Devices is a global semiconductor leader specializing in high-performance analog, mixed-signal, and digital signal processing technologies for precision measurement and industrial control.
The 5B Series was designed specifically for rugged industrial signal conditioning - delivering transformer-isolated, plug-in modules that meet FM/CSA Class 1 Div 2 and EN50082-1/EN50081-2 standards without custom engineering.
FAQ
What is the RTD type and temperature range supported by the 5B35-04-NI?
The 5B35-04-NI is configured for 100 Ω platinum RTDs with α = 0.00385 and supports a linearized input range of 0°C to +600°C. It delivers a corresponding 0–5 V output with ±0.78°C total accuracy. The "NI" suffix denotes nonincendive certification per FM/CSA Class 1 Division 2 requirements, confirming suitability for hazardous locations where flammable gases may be present only under fault conditions.
Does the 5B35-04-NI require external excitation or linearization circuitry?
No, the 5B35-04-NI includes an integrated 0.25 mA precision current source for RTD excitation and full hardware-based linearization. Its chopper-stabilized amplifier and calibrated analog signal path eliminate the need for external op-amps, ADCs, or microcontroller-based compensation algorithms. This makes the 5B35-04-NI a complete, drop-in signal conditioning solution - unlike discrete isolators such as ISO5852S which require external circuitry.
What isolation ratings apply to the 5B35-04-NI, and how are they implemented?
The 5B35-04-NI provides true three-port isolation: 1500 Vrms between input and output, 1500 Vrms between input and power, and 250 Vrms between output and power. This is achieved via transformer coupling with proprietary modulation, not optocouplers. The isolation architecture eliminates ground loops and enables floating field-side inputs - a key requirement for accurate 4-wire RTD measurements in electrically noisy industrial environments.
Can the 5B35-04-NI be used with other 5B Series modules on the same backplane?
Yes, the 5B35-04-NI is fully mix-and-match and hot-swappable with all standard 5B Series modules (e.g., 5B30 thermocouple, 5B40 voltage, 5B08 current input). All modules share identical mechanical dimensions (2.275" × 2.375" × 0.595"), pinout, and mounting interface. No PCB redesign or wiring changes are needed when substituting or adding modules - a core design advantage of the 5B platform.
What certifications does the 5B35-04-NI hold for industrial use?
The 5B35-04-NI is certified by Factory Mutual (FM) and the Canadian Standards Association (CSA) for Class 1, Division 2, Groups A, B, C, and D - confirming its nonincendive operation in hazardous locations. It also complies with EN50082-1 (immunity) and EN50081-2 (emissions) for electromagnetic compatibility in heavy industrial settings. These certifications are integral to the 5B35-04-NI's qualification - not optional add-ons - and are validated per the module's potted construction and isolation architecture.
5B35-04-NI Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Analog Devices Inc.
- Series:
- -
- Packaging:
- Tray
- Product Status:
- Obsolete
- Amplifier Type:
- Analog Output
- Voltage - Supply:
- 4.75V ~ 5.25V
- Output Type:
- Analog
- Current - Supply:
- 15 mA
- Operating Temperature:
- -40°C ~ 85°C
- Mounting Type:
- Surface Mount
5B35-04-NI FAQ
1.How can I place an order for 5B35-04-NI through Aetrix?
Please submit a Request for Quotation (RFQ) for 5B35-04-NI on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for 5B35-04-NI reliable?
The price and inventory of 5B35-04-NI are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for 5B35-04-NI is usually 5 days.
3.What payment methods are accepted for 5B35-04-NI?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for 5B35-04-NI transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for 5B35-04-NI?
5B35-04-NI orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your 5B35-04-NI order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for 5B35-04-NI?
For technical support, including 5B35-04-NI datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your 5B35-04-NI requirements.
6.How does Aetrix verify that 5B35-04-NI is sourced from the original manufacturer or authorized distributors?
All 5B35-04-NI products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that 5B35-04-NI meets industry standards.
7.What is the process for return or replacement of 5B35-04-NI?
All 5B35-04-NI units undergo pre-shipment inspection (PSI). If there is an issue with 5B35-04-NI, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The 5B35-04-NI part is unused and in its original packaging.
Return procedure for 5B35-04-NI:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
5B35-04-NI Tags

-
SEN-13879
SparkFun Electronics

-
GA-311
Panasonic Industrial Automation Sales

-
E32-T11N 2M
Omron Automation and Safety

-
FX-501P
Panasonic Industrial Automation Sales

-
FX-501
Panasonic Industrial Automation Sales

-
E3X-HD44
Omron Automation and Safety

-
E3X-HD41 2M
Omron Automation and Safety

-
FX-502
Panasonic Industrial Automation Sales

-
ASTC0000
Red Lion Controls

-
E3X-HD11 2M
Omron Automation and Safety

-
E3NX-MA11
Omron Automation and Safety

-
ESPICO-ALL
PalmSens BV
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…