Send an Inquiry

To receive a quote for your project, please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Part Number*
Quantity*
Message
Submit Inventory List

Please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Upload My List
Message

Analog Devices Inc. 5B35-05

Part No.:
5B35-05
Manufacturer:
Analog Devices Inc.
Category:
Sensor, Transducer Amplifiers
Package:
Datasheet:
Aetrix5B35-05.pdf
Description:
MODULE ISOL 4-WIRE RTD-IN LIN
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:1,854

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

5B35-05 from Analog Devices is a single-channel, isolated, linearized 4-wire RTD input signal conditioner with -100°C to +200°C input range, 0 V to +5 V output, ±0.60°C accuracy, 4 Hz bandwidth, and 1500 Vrms input-to-output isolation. It performs excitation, amplification, filtering, and isolation for platinum RTDs in industrial temperature monitoring systems.

For engineers reviewing the 5B35-05 datasheet, 5B35-05 pinout, 5B35-05 application, or 5B35-05 equivalent, key selection factors include its four-wire RTD linearization accuracy, true three-port isolation rating, 240 Vrms input terminal withstand, chopper-stabilized low-drift amplification, and hot-swappable 5B Series compatibility.

Technical Context

The 5B35-05 uses a precision 0.25 mA current source for 100 Ω Pt (α = 0.00385) excitation, with separate sense leads eliminating lead resistance error. Its chopper-stabilized differential amplifier delivers ±0.01°C/°C input offset drift and ±30 ppm/°C gain drift.

True three-port isolation separates field-side input, system-side output, and power domains-rated at 1500 Vrms (input–output and input–power) and 250 Vrms (output–power). A five-pole Butterworth filter provides 116 dB normal-mode rejection at 60 Hz and limits output noise to 100 µVrms (100 kHz BW).

Key Specifications

ParameterValue and Actual Design Meaning
Input Range-100°C to +200°C for 100 Ω Pt RTD (α = 0.00385)
Output Range0 V to +5 V, compatible with standard ADC inputs and PLC analog inputs
Accuracy±0.60°C total error including conformity, repeatability, and hysteresis
Isolation Rating1500 Vrms continuous between input/output and input/power; enables safe operation in Class 1 Div 2 hazardous locations
Bandwidth4 Hz (-3 dB), optimized for stable temperature measurement with high noise rejection
Excitation Current0.25 mA constant-current source, minimizing self-heating error in RTD sensing
Lead Resistance Effect±0.00001°C/Ω - negligible error even with long 4-wire runs

Pinout & Package

Package: 2.275" × 2.375" × 0.595" (57.8 mm × 59.1 mm × 15.1 mm) potted module with standardized 5B Series footprint and screw-terminal field connections.

Pin/TerminalCircuit RoleDesign Meaning
1: -EXCRTD excitation returnLow-side current sink for 0.25 mA excitation; connects to RTD leg opposite +EXC
2: LODifferential input lowHigh-impedance sense node for RTD voltage; no excitation current flows here
3: HIDifferential input highHigh-impedance sense node for RTD voltage; completes 4-wire Kelvin measurement
4: +EXCRTD excitation sourceConstant-current source output delivering 0.25 mA to RTD; referenced to -EXC

Key Features

FeatureDesign Value
Four-wire RTD linearizationHardware-based linearization over full -100°C to +200°C range eliminates need for software correction
True three-port isolationIndependent isolation barriers between input/output/power enable safe grounding schemes and prevent ground loops
240 Vrms input protectionWithstands continuous overvoltage on field terminals without damage or calibration shift
Hot-swappable 5B Series compatibilityInterchangeable with all 5B modules on same backplane without powering down or rewiring
Factory Mutual & CSA certificationApproved for Class 1, Division 2, Groups A/B/C/D - suitable for nonincendive use in hazardous areas

Applications

Industrial Temperature MonitoringHazardous Area Process Control

Use Scenario: Continuous monitoring of reactor vessel temperature using 100 Ω Pt RTD in chemical processing plant.

IC Role / Device Role / Timing Role: Isolated linearized RTD signal conditioner converting resistance to calibrated 0–5 V analog output.

Use Value: Delivers ±0.60°C accuracy across -100°C to +200°C while rejecting 60 Hz noise by 116 dB and surviving 240 Vrms transients.

Use Scenario: Temperature supervision in solvent storage tanks where flammable vapors may be present under fault conditions.

IC Role / Device Role / Timing Role: Intrinsically safe signal interface providing FM/CSA-certified isolation and nonincendive operation.

Use Value: Meets Class 1 Div 2 requirements with 1500 Vrms input–output isolation and no requirement for explosion-proof enclosures.

PLC Analog Input ConditioningMulti-Channel RTD Data Acquisition

Use Scenario: Retrofitting legacy PLCs with unconditioned analog inputs to accept 4-wire RTD signals from HVAC chillers.

IC Role / Device Role / Timing Role: Signal conditioner bridging field RTD sensors to PLC's 0–5 V ADC input with galvanic isolation.

Use Value: Eliminates external signal conditioning hardware; 25 Ω output impedance drives long cables into PLC input capacitance without instability.

Use Scenario: High-density data acquisition system using 5B backplane with multiple 5B35 variants for different RTD ranges.

IC Role / Device Role / Timing Role: Hot-swappable channel module enabling flexible configuration of -100°C to +200°C, 0–100°C, and 0–600°C RTD inputs on one chassis.

Use Value: Mix-and-match capability allows precise range matching per sensor without custom firmware or calibration tables.

Equivalent & Alternatives

The following parts are listed as comparable options for similar RTD signal conditioning applications.

Alternative PartTechnical DifferenceApplication DifferenceSelection Advice
ADAM-4017+ (Advantech)8-channel Ethernet-connected RTD module; no transformer isolation; 16-bit resolution; software linearization requiredDesigned for networked SCADA systems rather than direct PLC/analog input interfacingSelect when centralized remote monitoring via TCP/IP is needed, not local analog output
ISO5852S (Texas Instruments)Single-chip isolated amplifier with 1500 Vrms rating but no built-in RTD excitation or linearization; requires external circuitryTargeted at custom-designed signal chains, not drop-in replacement for plug-in modulesSelect only when designing fully custom isolated analog front-end with discrete RTD biasing and computation

Compared with ADAM-4017+ and ISO5852S, the 5B35-05 delivers factory-calibrated linearized analog output with integrated excitation and certified hazardous-area approval-requiring no software configuration or external components for immediate deployment in industrial control cabinets.

Availability

5B35-05 is available at Aetrix Electronics and suitable for industrial temperature monitoring, hazardous area process control, and PLC analog input conditioning requiring stable component supply, long-term lifecycle support, and certified safety compliance.

Supply support for 5B35-05 includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

Analog Devices is a global semiconductor company specializing in high-performance analog, mixed-signal, and digital signal processing technologies for industrial, automotive, and communications markets.

The 5B Series was designed as a family of rugged, plug-in signal conditioners for industrial measurement and control-delivering transformer-isolated, linearized analog outputs with FM/CSA certification and hot-swap capability in compact potted modules.

FAQ

What is the input RTD type and alpha coefficient supported by the 5B35-05?

The 5B35-05 is configured for 100 Ω platinum RTDs with temperature coefficient α = 0.00385. It uses a 0.25 mA precision excitation current and hardware linearization optimized specifically for this RTD type across the -100°C to +200°C range. The 5B35-05 does not support copper or nickel RTDs-those require other models like 5B35-C-01 or 5B35-N-01.

Does the 5B35-05 require external power supply filtering or decoupling?

No, the 5B35-05 operates from a +5 V dc ±5% supply and includes internal regulation and filtering. Its specified power supply sensitivity is ±0.2°C/% of Vs, and it draws only 15 mA. External bulk capacitance is unnecessary unless shared with noisy digital circuits; the module itself meets EN50082-1 EMC immunity requirements up to 10 V/m at 1 GHz.

Can the 5B35-05 be used with 3-wire or 2-wire RTDs?

No-the 5B35-05 is strictly a 4-wire RTD input module. Its pinout (HI, LO, +EXC, -EXC) and internal architecture assume Kelvin sensing with separate excitation and sense paths. Using it with 3-wire or 2-wire RTDs introduces uncorrected lead resistance errors and violates its calibration. For 3-wire applications, consider the 5B34 series instead.

What is the maximum allowable lead resistance for accurate operation of the 5B35-05?

The 5B35-05 exhibits ±0.00001°C/Ω lead resistance effect for 100 Ω Pt RTDs. This means 100 Ω of total lead resistance contributes only ±0.001°C error-well within its ±0.60°C total accuracy spec. Practically, lead resistances up to several kΩ introduce negligible error, making it suitable for installations with long sensor cable runs without recalibration.

Is the 5B35-05 compatible with all 5B Series backplanes and mounting sockets?

Yes-the 5B35-05 shares identical mechanical dimensions (2.275" × 2.375" × 0.595"), pinout, and electrical interface with all standard 5B Series modules. It is fully hot-swappable on any 5B backplane-including those with cold-junction compensation for thermocouples-and requires no configuration jumpers or DIP switches for operation.

5B35-05 Specifications

Product attributes
Attribute value
Manufacturer:
Analog Devices Inc.
Series:
-
Packaging:
Bulk
Product Status:
Obsolete
Amplifier Type:
-
Voltage - Supply:
-
Output Type:
-
Current - Supply:
-
Operating Temperature:
-
Mounting Type:
-

5B35-05 FAQ

1.How can I place an order for 5B35-05 through Aetrix?

Please submit a Request for Quotation (RFQ) for 5B35-05 on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for 5B35-05 reliable?

The price and inventory of 5B35-05 are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for 5B35-05 is usually 5 days.

3.What payment methods are accepted for 5B35-05?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for 5B35-05 transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for 5B35-05?

5B35-05 orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your 5B35-05 order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for 5B35-05?

For technical support, including 5B35-05 datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your 5B35-05 requirements.

6.How does Aetrix verify that 5B35-05 is sourced from the original manufacturer or authorized distributors?

All 5B35-05 products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that 5B35-05 meets industry standards.

7.What is the process for return or replacement of 5B35-05?

All 5B35-05 units undergo pre-shipment inspection (PSI). If there is an issue with 5B35-05, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The 5B35-05 part is unused and in its original packaging.

Return procedure for 5B35-05:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

5B35-05 Tags

  • 5B35-05
  • 5B35-05 PDF
  • 5B35-05 Datasheet
  • 5B35-05 Specifications
  • 5B35-05 Images
  • Analog Devices Inc.
  • Analog Devices Inc. 5B35-05
  • Buy 5B35-05
  • 5B35-05 Price
  • 5B35-05 Distributor
  • 5B35-05 Supplier
  • 5B35-05 Wholesale
Related Products
SEN-13879
SEN-13879

SparkFun Electronics

GA-311
GA-311

Panasonic Industrial Automation Sales

E32-T11N 2M
E32-T11N 2M

Omron Automation and Safety

FX-501P
FX-501P

Panasonic Industrial Automation Sales

FX-501
FX-501

Panasonic Industrial Automation Sales

E3X-HD44
E3X-HD44

Omron Automation and Safety

E3X-HD41 2M
E3X-HD41 2M

Omron Automation and Safety

FX-502
FX-502

Panasonic Industrial Automation Sales

ASTC0000
ASTC0000

Red Lion Controls

E3X-HD11 2M
E3X-HD11 2M

Omron Automation and Safety

E3NX-MA11
E3NX-MA11

Omron Automation and Safety

ESPICO-ALL
ESPICO-ALL

PalmSens BV

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER