Send an Inquiry

To receive a quote for your project, please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Part Number*
Quantity*
Message
Submit Inventory List

Please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Upload My List
Message

Analog Devices Inc. 5B35-N-01

Part No.:
5B35-N-01
Manufacturer:
Analog Devices Inc.
Category:
Sensor, Transducer Amplifiers
Package:
Datasheet:
Aetrix5B35-N-01.pdf
Description:
MODULE ISOL 4-WIRE RTD-IN LIN
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:4,846

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

5B35-N-01 from Analog Devices is a single-channel isolated linearized 4-wire RTD input signal conditioner for nickel (120 Ω, α = 0.00672) sensors, delivering 0 V to +5 V output with ±0.40°C accuracy over 0°C to +300°C, 1500 Vrms input-output isolation, and 4 Hz bandwidth. It performs excitation, amplification, filtering, and linearization in industrial measurement systems.

For engineers reviewing the 5B35-N-01 datasheet, 5B35-N-01 pinout, 5B35-N-01 application, or 5B35-N-01 equivalent, key selection factors include its 120 Ω nickel RTD support, true three-port isolation, chopper-stabilized low-drift amplification (+0.01°C/°C offset drift), 240 Vrms input protection, and hot-swappable 5B Series compatibility.

Technical Context

The 5B35-N-01 uses transformer-coupled true three-port isolation (input/output/power), with proprietary modulation/demodulation for linear signal recovery. Its chopper-stabilized differential amplifier enables low-excitation-current operation (0.25 mA) to minimize RTD self-heating error.

It integrates a five-pole Butterworth filter (4 Hz –3 dB bandwidth), achieving 116 dB normal-mode rejection at 60 Hz and delivering 100 µVrms output noise in 100 kHz bandwidth. Input protection withstands 240 Vrms continuously and meets ANSI/IEEE C37.90.1-1989 transient standards.

Key Specifications

ParameterValue and Actual Design Meaning
Input Type4-wire 120 Ω nickel RTD (α = 0.00672), 0°C to +300°C range
Output Signal0 V to +5 V linearized voltage, compatible with standard ADC inputs
Accuracy±0.40°C total error including conformity, repeatability, and hysteresis
Isolation Rating1500 Vrms between input–output and input–power; 250 Vrms output–power
Bandwidth4 Hz –3 dB, optimized for stable temperature measurement with high noise rejection
Excitation Current0.25 mA precision current source, minimizing RTD self-heating error
Lead Resistance Effect±0.00001°C/Ω - negligible error from long sensor leads in 4-wire configuration

Pinout & Package

Package: 2.275" × 2.375" × 0.595" (57.8 mm × 59.1 mm × 15.1 mm) potted module with standardized 5B Series footprint and screw-terminal field-side interface.

Pin/TerminalCircuit RoleDesign Meaning
1: –EXCRTD excitation returnNegative terminal of 0.25 mA excitation current source; connects to one RTD leg
2: LODifferential input lowLow-side voltage sense terminal; carries no excitation current, enabling lead resistance cancellation
3: HIDifferential input highHigh-side voltage sense terminal; measures RTD voltage drop without excitation current path
4: +EXCRTD excitation supplyPositive terminal of 0.25 mA excitation current source; connects to opposite RTD leg

Key Features

FeatureDesign Value
True three-port isolationIndependent galvanic separation of input, output, and power domains eliminates ground loops and enables floating field-side measurement
Chopper-stabilized amplification+0.01°C/°C input offset drift ensures stable calibration across –40°C to +85°C operating range
Optimized 4 Hz filteringFive-pole Butterworth response rejects 50/60 Hz line noise by ≥108 dB while preserving step response (100 ms rise time)
240 Vrms input protectionWithstands continuous overvoltage on field terminals without damage, shielding downstream data acquisition circuitry
Hot-swappable 5B Series compatibilityIdentical mechanical footprint and pinout allows replacement or reconfiguration without powering down backplane or disturbing wiring

Applications

Industrial Temperature MonitoringHazardous Area Signal Conditioning

Use Scenario: Continuous monitoring of nickel RTD sensors in chemical reactor vessels operating from 0°C to 300°C.

IC Role / Device Role / Timing Role: Isolated linearized analog front-end converting RTD resistance to calibrated 0–5 V signal for PLC analog input modules.

Use Value: Eliminates lead-wire error via 4-wire sensing and prevents ground-loop-induced drift using 1500 Vrms isolation.

Use Scenario: Signal conditioning for nickel RTDs in Class 1, Division 2, Groups A–D hazardous locations per FM/CSA certification.

IC Role / Device Role / Timing Role: Nonincendive field-side interface providing intrinsic safety compliance without external barriers or enclosures.

Use Value: Certified operation in flammable gas environments under fault conditions, enabled by transformer isolation and 240 Vrms input withstand.

High-Accuracy Process ControlEMI-Robust Data Acquisition

Use Scenario: Closed-loop temperature control in pharmaceutical batch processing requiring ±0.40°C sensor accuracy and long-term stability.

IC Role / Device Role / Timing Role: Precision linearization and drift-compensated amplification stage preceding PID controller input.

Use Value: Conformity error limited to ±0.05% span and gain drift of ±0.003%/°C ensure consistent setpoint tracking across ambient temperature swings.

Use Scenario: Analog signal capture in factory-floor SCADA systems exposed to 400 MHz, 5 W RF fields at 3 ft distance.

IC Role / Device Role / Timing Role: EMI-hardened front-end suppressing RFI-induced errors to <±0.5% full scale per EN50082-1 compliance.

Use Value: Maintains measurement integrity without additional shielding or filtering due to integrated transformer isolation and 190 dB CMR at 50/60 Hz.

Equivalent & Alternatives

The following parts are listed as comparable options for similar RTD signal conditioning applications.

Alternative PartTechnical DifferenceApplication DifferenceSelection Advice
5B35-01100 Ω platinum RTD (α = 0.00385), –100°C to +100°C range, ±0.26°C accuracyLower temperature range and higher base accuracy; optimized for Pt100 in HVAC and lab instrumentationSelect when using standard platinum RTDs and tighter accuracy is required below 100°C
5B35-04100 Ω platinum RTD, 0°C to +600°C range, ±0.78°C accuracy, higher excitation current toleranceExtended high-temperature capability; suited for kiln and furnace monitoring where nickel RTDs saturateSelect for >300°C measurements where 120 Ω nickel is unsuitable and Pt100 is preferred

Compared with 5B35-01 and 5B35-04, the 5B35-N-01 uniquely supports 120 Ω nickel RTDs up to +300°C with balanced accuracy and isolation-making it optimal for mid-range industrial processes where nickel's positive α and cost advantage outweigh platinum's extended range.

Availability

5B35-N-01 is available at Aetrix Electronics and suitable for industrial temperature monitoring, hazardous area signal conditioning, and high-accuracy process control requiring stable component supply, long-lifecycle availability, and certified isolation performance.

Supply support for 5B35-N-01 includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

Analog Devices is a global semiconductor company specializing in high-performance analog, mixed-signal, and digital signal processing technologies for precision measurement and industrial control.

The 5B Series was designed specifically for rugged industrial signal conditioning-delivering transformer-isolated, linearized, and protected analog I/O in compact, hot-swappable modules for PLC, DCS, and data acquisition systems.

FAQ

What RTD type and temperature range does the 5B35-N-01 support?

The 5B35-N-01 supports 120 Ω nickel RTDs with temperature coefficient α = 0.00672 across 0°C to +300°C. It delivers a linearized 0 V to +5 V output with ±0.40°C total accuracy. The module uses dedicated 0.25 mA excitation and four-wire sensing to eliminate lead resistance error-making it distinct from platinum or copper variants in the 5B35 family.

Does the 5B35-N-01 provide galvanic isolation, and what are its ratings?

Yes, the 5B35-N-01 provides true three-port galvanic isolation: 1500 Vrms between input–output and input–power, and 250 Vrms between output–power. This isolation is transformer-based with proprietary modulation, enabling safe interfacing between hazardous field-side sensors and grounded control system electronics without shared ground references.

How does the 5B35-N-01 handle noise and electromagnetic interference?

The 5B35-N-01 integrates a five-pole Butterworth filter with 4 Hz –3 dB bandwidth, achieving 116 dB normal-mode rejection at 60 Hz and 190 dB common-mode rejection at 50/60 Hz. Tested per EN50082-1, it maintains <±0.5% span error under 400 MHz, 5 W RF fields at 3 ft-ensuring reliable operation in electrically noisy industrial environments without external filtering.

Can the 5B35-N-01 be used in hazardous locations, and what certifications apply?

Yes, the 5B35-N-01 is certified by Factory Mutual (FM) and CSA for Class 1, Division 2, Groups A, B, C, and D-meaning it is approved for use where flammable gases may exist only under fault conditions. Its nonincendive design requires no special enclosures, relying on intrinsic energy limitation and isolation to prevent ignition in hazardous areas.

What are the power requirements and thermal specifications for the 5B35-N-01?

The 5B35-N-01 operates from +5 V dc ±5% and draws 15 mA typical supply current. It maintains rated performance from –40°C to +85°C ambient, with input offset drift of ±0.01°C/°C and gain drift of ±0.003% of reading/°C. Power supply sensitivity is ±0.2°C/% of Vs, ensuring stable output even with minor rail variations.

5B35-N-01 Specifications

Product attributes
Attribute value
Manufacturer:
Analog Devices Inc.
Series:
-
Packaging:
Bulk
Product Status:
Obsolete
Amplifier Type:
-
Voltage - Supply:
-
Output Type:
-
Current - Supply:
-
Operating Temperature:
-
Mounting Type:
-

5B35-N-01 FAQ

1.How can I place an order for 5B35-N-01 through Aetrix?

Please submit a Request for Quotation (RFQ) for 5B35-N-01 on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for 5B35-N-01 reliable?

The price and inventory of 5B35-N-01 are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for 5B35-N-01 is usually 5 days.

3.What payment methods are accepted for 5B35-N-01?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for 5B35-N-01 transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for 5B35-N-01?

5B35-N-01 orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your 5B35-N-01 order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for 5B35-N-01?

For technical support, including 5B35-N-01 datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your 5B35-N-01 requirements.

6.How does Aetrix verify that 5B35-N-01 is sourced from the original manufacturer or authorized distributors?

All 5B35-N-01 products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that 5B35-N-01 meets industry standards.

7.What is the process for return or replacement of 5B35-N-01?

All 5B35-N-01 units undergo pre-shipment inspection (PSI). If there is an issue with 5B35-N-01, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The 5B35-N-01 part is unused and in its original packaging.

Return procedure for 5B35-N-01:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

5B35-N-01 Tags

  • 5B35-N-01
  • 5B35-N-01 PDF
  • 5B35-N-01 Datasheet
  • 5B35-N-01 Specifications
  • 5B35-N-01 Images
  • Analog Devices Inc.
  • Analog Devices Inc. 5B35-N-01
  • Buy 5B35-N-01
  • 5B35-N-01 Price
  • 5B35-N-01 Distributor
  • 5B35-N-01 Supplier
  • 5B35-N-01 Wholesale
Related Products
SEN-13879
SEN-13879

SparkFun Electronics

GA-311
GA-311

Panasonic Industrial Automation Sales

E32-T11N 2M
E32-T11N 2M

Omron Automation and Safety

FX-501P
FX-501P

Panasonic Industrial Automation Sales

FX-501
FX-501

Panasonic Industrial Automation Sales

E3X-HD44
E3X-HD44

Omron Automation and Safety

E3X-HD41 2M
E3X-HD41 2M

Omron Automation and Safety

FX-502
FX-502

Panasonic Industrial Automation Sales

ASTC0000
ASTC0000

Red Lion Controls

E3X-HD11 2M
E3X-HD11 2M

Omron Automation and Safety

E3NX-MA11
E3NX-MA11

Omron Automation and Safety

ESPICO-ALL
ESPICO-ALL

PalmSens BV

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER