Analog Devices Inc. 5B40-05-MB
- Part No.:
- 5B40-05-MB
- Manufacturer:
- Analog Devices Inc.
- Category:
- Sensor, Transducer Amplifiers
- Package:
- Datasheet:
-
5B40-05-MB.pdf
- Description:
- PLUG-IN SIGNAL CONDITIONER
- Quantity:
- Payment:

- Shipping:

Inventory:2,070
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
5B40-05-MB from Analog Devices is a single-channel isolated analog input signal conditioner designed for industrial voltage measurement. It accepts ±50 mV input, delivers 0 V to +5 V output, provides 10 kHz bandwidth, 1500 Vrms isolation, and withstands 240 Vrms continuous input overvoltage-used in plastic injection molding pressure monitoring and crash-test strain sensing.
For engineers reviewing the 5B40-05-MB datasheet, 5B40-05-MB pinout, 5B40-05-MB application, or 5B40-05-MB equivalent, key selection criteria include input range compatibility (±50 mV), unipolar 0–5 V output requirement, transformer-based isolation integrity, hot-swap capability in 5B-series backplanes, and compliance with FM/CSA Class 1 Div 2 hazardous location standards.
Technical Context
The 5B40-05-MB implements chopper-stabilized amplification with laser-trimmed zero-scale offset subtraction, enabling precise expanded-scale measurements of small differential signals. Its input stage includes a single-pole anti-aliasing filter and 200 MΩ powered-on input resistance, while the output stage uses a three-pole low-pass filter to optimize noise performance at 10 kHz bandwidth.
Transformer-coupled isolation employs a proprietary modulation/demodulation scheme ensuring linear signal transfer without grounding constraints on the field side. The differential input is fully floating, and the output common must remain within ±3 V of power common-critical for maintaining accuracy in noisy industrial environments.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Input Range | ±50 mV - supports high-resolution measurement of low-level millivolt signals such as thermopile or strain gauge outputs. |
| Output Range | 0 V to +5 V - directly interfaces with standard ADC inputs requiring unipolar reference-compatible signaling. |
| Bandwidth (–3 dB) | 10 kHz - enables accurate capture of rapidly varying transients like bearing vibration pre-failure signatures. |
| Isolation Rating | 1500 Vrms continuous - protects downstream PLCs and data acquisition systems from field-side fault voltages. |
| Input Overvoltage Withstand | 240 Vrms - eliminates need for external transient protection circuitry at screw-terminal inputs. |
| Accuracy (25°C) | ±0.05% Span ±10 µV RTI - ensures calibrated precision across full scale without recalibration in stable environments. |
| CMR (50/60 Hz) | 100 dB @ 1 kΩ imbalance - rejects common-mode interference from AC-powered machinery and motor drives. |
Pinout & Package
5B40-05-MB uses a standardized 2.275" × 2.375" × 0.595" (57.8 mm × 59.1 mm × 15.1 mm) potted module package compatible with all 5B-series backplanes and sockets. Input connections are made via screw terminals labeled HI and LO; no PCB-mounted pins are present.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| HI | Field-Side Input High | Differential positive input terminal; accepts up to ±50 mV referenced to LO; fully floating with respect to system ground. |
| LO | Field-Side Input Low | Differential negative input terminal; completes input path; enables true differential measurement without shared ground. |
Key Features
| Feature | Design Value |
|---|---|
| Transformer-Based Isolation | 1500 Vrms continuous rating with proprietary modulation ensures long-term stability and immunity to EMI-induced drift. |
| Chopper-Stabilized Amplifier | ±1 µV/°C input offset drift enables stable DC-coupled measurement over industrial temperature ranges (–25°C to +85°C). |
| Hot-Swappable Module | Plug-and-play replacement in live 5B backplanes without interrupting field wiring or system power-reduces maintenance downtime. |
| Integrated Anti-Aliasing Filter | Single-pole input filter combined with three-pole output filter achieves optimal SNR for sub-millivolt signal recovery in electrically noisy plants. |
| FM/CSA Hazardous Location Approval | Class 1, Division 2, Groups A, B, C, D certification permits deployment in areas where flammable gas may exist only under fault conditions. |
Applications
| Plastic Injection Molding Pressure Monitoring | Automotive Crash-Test Strain Sensing |
|---|---|
Use Scenario: Real-time cavity pressure measurement during rapid mold-fill cycles with high dv/dt transients. IC Role / Device Role / Timing Role: Isolated signal conditioner converting piezoresistive sensor mV output to noise-immune 0–5 V for DAQ sampling. Use Value: 10 kHz bandwidth captures pressure spikes <100 µs wide; 240 Vrms input protection prevents damage from solenoid switching transients. | Use Scenario: Dynamic strain measurement on vehicle chassis during controlled impact testing. IC Role / Device Role / Timing Role: High-fidelity front-end amplifier and isolator for foil strain gauges mounted on structural members. Use Value: ±50 mV input range matches typical gauge bridge outputs; 100 dB CMR rejects ignition noise and alternator ripple. |
| Bearing Vibration Pre-Failure Detection | Industrial Thermopile Temperature Profiling |
Use Scenario: Continuous monitoring of high-frequency vibration harmonics preceding mechanical failure in rotating equipment. IC Role / Device Role / Timing Role: Wide-bandwidth isolated interface between accelerometer and control system ADC. Use Value: 10 kHz flat response preserves spectral content up to 5th harmonic of 2 kHz rotation; chopper stabilization minimizes baseline drift during extended runs. | Use Scenario: Non-contact surface temperature mapping using thermopile arrays in furnace or kiln control systems. IC Role / Device Role / Timing Role: Precision millivolt-range conditioner for thermopile sensors with ambient-referenced zero suppression. Use Value: Laser-trimmed zero-offset allows suppression of large ambient offset (e.g., 20 mV) while resolving <100 µV changes in target radiation. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar isolated analog input conditioning applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| 5B40-05 | No mounting bracket; same electrical specs and pinout as 5B40-05-MB. | Requires separate mechanical mounting; not pre-assembled for panel or DIN-rail use. | Select 5B40-05-MB when integrated bracket simplifies installation in control cabinets or field enclosures. |
| 5B41-05 | Wider ±5 V input range; identical 0–5 V output; higher input bias current (±0.2 nA vs. ±3 nA) and lower CMR (90 dB). | Suitable for higher-level industrial voltage signals but less optimal for sub-50 mV sensor outputs. | Choose 5B40-05-MB for millivolt-range sensors; select 5B41-05 only if input exceeds ±50 mV and CMR >90 dB is acceptable. |
Compared with 5B40-05 and 5B41-05, the 5B40-05-MB offers identical signal conditioning performance with factory-integrated mechanical mounting-eliminating assembly steps while preserving hot-swap compatibility and hazardous-area certifications required in OEM control systems.
Availability
5B40-05-MB is available at Aetrix Electronics and suitable for industrial signal isolation, plastic molding machine monitoring, and automotive test cell instrumentation requiring stable component supply across multi-year production programs.
Supply support for 5B40-05-MB includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Analog Devices is a global semiconductor company specializing in high-performance analog, mixed-signal, and digital signal processing technologies for precision measurement and industrial control.
The 5B Series was engineered specifically for rugged industrial signal conditioning-delivering transformer isolation, calibrated accuracy, and hot-swap readiness in compact potted modules approved for hazardous locations.
FAQ
What is the input voltage range supported by the 5B40-05-MB?
The 5B40-05-MB supports an input range of ±50 mV, optimized for low-level millivolt signals from strain gauges, thermopiles, and other precision sensors. This range is factory-set and cannot be adjusted in-field. The module's chopper-stabilized amplifier and laser-trimmed offset enable accurate zero-suppression, allowing users to resolve small signal variations even when a large ambient offset is present. All specifications-including accuracy and bandwidth-are guaranteed only within this defined ±50 mV span.
Does the 5B40-05-MB require external power supply filtering or decoupling?
No, the 5B40-05-MB operates from a single +5 V ±5% supply and draws 30 mA; its internal design includes robust power supply rejection (±2 µV/Vs%) and built-in filtering that meets EN50082-1 EMC requirements. External decoupling is unnecessary when installed per the 5B Series User Manual. The module has been validated to maintain <0.1% full-scale error under 10 V/m RFI fields up to 1 GHz, confirming its self-contained immunity without added components.
Can the 5B40-05-MB be used in Class 1, Division 2 hazardous locations?
Yes, the 5B40-05-MB is certified by Factory Mutual (FM) and the Canadian Standards Association (CSA) for Class 1, Division 2, Groups A, B, C, and D. These approvals confirm it is "nonincendive"-safe for use where flammable gases may exist only under fault conditions-without requiring explosion-proof enclosures. The certification applies to the complete potted module including its mounting bracket, and remains valid when installed in approved 5B-series backplanes with proper field wiring practices.
How does the 5B40-05-MB handle common-mode voltage on its input?
The 5B40-05-MB features a fully floating differential input with 1500 Vrms continuous input-to-output common-mode voltage rating and 100 dB CMR at 50/60 Hz with 1 kΩ source imbalance. Its transformer isolation eliminates ground loops, and the input circuitry withstands up to 240 Vrms continuously without damage. This makes the 5B40-05-MB suitable for measuring signals referenced to noisy or elevated potentials-such as motor phase currents or grounded thermocouple junctions-without signal corruption or component stress.
Is the 5B40-05-MB compatible with standard 5B-series backplanes?
Yes, the 5B40-05-MB shares identical mechanical dimensions (2.275" × 2.375" × 0.595"), pinout, and hot-swap functionality with all 5B Series modules. It mates seamlessly with 5B01, 5B08, and other FM/CSA-approved backplanes featuring screw-terminal field connections. No firmware, configuration, or jumper settings are required-the 5B40-05-MB operates immediately upon insertion, delivering calibrated 0–5 V output with no setup delay or calibration routine needed.
5B40-05-MB Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Analog Devices Inc.
- Series:
- -
- Packaging:
- Bulk
- Product Status:
- Active
- Amplifier Type:
- General Purpose
- Voltage - Supply:
- 4.75V ~ 5.25V
- Output Type:
- Analog
- Current - Supply:
- 30 mA
- Operating Temperature:
- -40°C ~ 85°C
- Mounting Type:
- Surface Mount
5B40-05-MB FAQ
1.How can I place an order for 5B40-05-MB through Aetrix?
Please submit a Request for Quotation (RFQ) for 5B40-05-MB on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for 5B40-05-MB reliable?
The price and inventory of 5B40-05-MB are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for 5B40-05-MB is usually 5 days.
3.What payment methods are accepted for 5B40-05-MB?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for 5B40-05-MB transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for 5B40-05-MB?
5B40-05-MB orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your 5B40-05-MB order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for 5B40-05-MB?
For technical support, including 5B40-05-MB datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your 5B40-05-MB requirements.
6.How does Aetrix verify that 5B40-05-MB is sourced from the original manufacturer or authorized distributors?
All 5B40-05-MB products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that 5B40-05-MB meets industry standards.
7.What is the process for return or replacement of 5B40-05-MB?
All 5B40-05-MB units undergo pre-shipment inspection (PSI). If there is an issue with 5B40-05-MB, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The 5B40-05-MB part is unused and in its original packaging.
Return procedure for 5B40-05-MB:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
5B40-05-MB Tags

-
SEN-13879
SparkFun Electronics

-
GA-311
Panasonic Industrial Automation Sales

-
E32-T11N 2M
Omron Automation and Safety

-
FX-501P
Panasonic Industrial Automation Sales

-
FX-501
Panasonic Industrial Automation Sales

-
E3X-HD44
Omron Automation and Safety

-
E3X-HD41 2M
Omron Automation and Safety

-
FX-502
Panasonic Industrial Automation Sales

-
ASTC0000
Red Lion Controls

-
E3X-HD11 2M
Omron Automation and Safety

-
E3NX-MA11
Omron Automation and Safety

-
ESPICO-ALL
PalmSens BV
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…