Product details
Overview
5B47-CUSTOM from Analog Devices is a single-channel, isolated, linearized thermocouple input signal conditioner supporting J, K, T, E, R, S, and B thermocouple types. It delivers a precision 0 V to +5 V isolated output with ±0.5°C to ±5.1°C accuracy (model-dependent), 4 Hz bandwidth, and 1500 Vrms continuous input-to-output isolation - used in industrial temperature monitoring systems requiring cold-junction compensation and field-side overvoltage protection.
For engineers reviewing the 5B47-CUSTOM datasheet, 5B47-CUSTOM pinout, 5B47-CUSTOM application, or 5B47-CUSTOM equivalent, key selection criteria include custom input/output range configuration, open-thermocouple detection behavior, chopper-stabilized amplifier drift (±1 µV/°C), CJC accuracy contribution, and compatibility with 5B Series backplanes for hot-swap deployment in Class 1, Division 2 hazardous locations.
Technical Context
The 5B47-CUSTOM implements transformer-based galvanic isolation with proprietary modulation for linear signal recovery, featuring a fully floating differential field-side input that eliminates grounding requirements. Its chopper-stabilized input amplifier provides ±1 µV/°C input offset drift and internal laser-trimmed zero-scale subtraction for expanded-scale measurements.
It integrates multi-pole low-pass filtering (4 Hz –3 dB), 160 dB common-mode rejection at 50/60 Hz with 1 kΩ source imbalance, and 60 dB normal-mode rejection - enabling accurate microvolt-level thermocouple signal acquisition in high-noise industrial environments. The module supports active-low output enable control and generates an upscale open-input response within 10 seconds.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Isolation Rating | 1500 Vrms continuous input-to-output - protects downstream DAQ or PLC circuitry from field-side faults up to 240 Vrms. |
| Bandwidth | 4 Hz (–3 dB) - suppresses 50/60 Hz line noise and higher-frequency interference while preserving slow thermal transients. |
| Cold Junction Accuracy | ±0.25°C @ +25°C ambient - corrects parasitic thermocouple errors at screw terminals for system-level temperature accuracy. |
| Input Offset Drift | ±1 µV/°C - equivalent to ≤0.025°C/°C for Type K/T, ensuring stable zero-point over operating temperature (–25°C to +85°C). |
| Output Enable Logic | Active-low; logic "0" ≤ +1 V, logic "1" ≥ +2.5 V - enables synchronized channel gating without external multiplexers. |
| Noise (Input, 0.1–10 Hz) | 0.2 µVrms - supports resolution of sub-degree temperature changes in low-drift applications. |
| Open Input Response | Upscale (e.g., >+4.9 V) after 10 s - provides fail-safe indication of broken thermocouple wiring. |
Pinout & Package
Package: 2.275" × 2.375" × 0.595" (57.8 mm × 59.1 mm × 15.1 mm) potted module with standardized 5B Series footprint and screw-terminal field interface. Compatible with FM- and CSA-approved backplanes (e.g., 5B-01, 5B-08) for hot-swap insertion.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 (–EXC) | Excitation Return / Cold Junction Sensor Reference | Provides return path for internal CJC sensor bias; connects to LO on backplane for reference stability. |
| 2 (LO) | Input Low / Signal Return | Field-side signal return terminal; forms differential pair with HI; fully floating, no ground reference required. |
| 3 (HI) | Input High / Thermocouple Positive | Accepts thermocouple voltage (±5 mV to ±500 mV); internally linearized and amplified before isolation. |
| 4 (N/C) | No Connect | Unbonded terminal; must remain unconnected per design - no routing or loading permitted. |
Key Features
| Feature | Design Value |
|---|---|
| Transformer-Based Isolation | 1500 Vrms continuous rating with proprietary modulation - ensures long-term reliability without optocoupler aging or gain drift. |
| Internal Linearization | Hardware-based polynomial correction per thermocouple type - eliminates need for host-side software linearization or lookup tables. |
| Chopper-Stabilized Amplifier | ±1 µV/°C input offset drift - maintains calibration integrity across –25°C to +85°C operating range without recalibration. |
| Hot-Swappable Design | Compatible with all 5B Series sockets - allows live replacement without power cycling or rewiring field connections. |
| Custom Range Support | Configurable input (±5 mV to ±500 mV) and output (0 V to +5 V or +1 V to +5 V) - enables optimized span for specific sensor curves or process windows. |
Applications
| Industrial Temperature Monitoring | Hazardous Location Process Control |
|---|---|
|
Use Scenario: Continuous temperature measurement in chemical reactor vessels with explosive vapor risk. IC Role / Device Role / Timing Role: Isolated thermocouple signal conditioner providing fault-tolerant analog input to safety-rated PLCs. Use Value: FM/CSA Class 1 Div 2 approval enables direct installation in Zone 2 areas without explosion-proof enclosures. |
Use Scenario: Multi-point furnace temperature profiling in semiconductor diffusion furnaces. IC Role / Device Role / Timing Role: Linearized, low-drift analog front-end converting Type K thermocouple outputs to 0–5 V for data acquisition. Use Value: 4 Hz bandwidth and 60 dB NMR reject RF noise from nearby RF heaters while preserving thermal ramp fidelity. |
| Legacy System Retrofit | Modular SCADA I/O Expansion |
|
Use Scenario: Upgrading analog recorder inputs in aging refinery control rooms with minimal wiring changes. IC Role / Device Role / Timing Role: Drop-in replacement for obsolete signal conditioners using identical 5B Series socket and screw-terminal interface. Use Value: Same mechanical footprint and pinout as legacy 5B modules - eliminates panel rework and downtime. |
Use Scenario: Adding thermocouple channels to distributed I/O racks in water treatment plants. IC Role / Device Role / Timing Role: Hot-swappable field-conditioning node interfacing with 5B backplanes and AC1361 cold-junction sensors. Use Value: Internal CJC and mix-and-match capability allow scalable, maintenance-friendly channel expansion. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar isolated thermocouple conditioning applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| ADAM-4018 (Advantech) | 8-channel modular RTD/thermocouple input with Ethernet interface; no internal linearization - requires host-side processing. | Designed for networked remote I/O; lacks FM/CSA hazardous location certification and transformer isolation. | Choose when centralized Ethernet-based monitoring is prioritized over intrinsic safety and analog output simplicity. |
| ISO-TC (Texas Instruments) | Single-channel isolated thermocouple amplifier with integrated CJC; 1000 Vrms isolation; no screw-terminal field interface. | Requires PCB-level integration and external terminal blocks; not hot-swappable or backplane-compatible. | Choose for space-constrained embedded designs where board-mount isolation suffices and field-serviceability is secondary. |
Compared with ADAM-4018 and ISO-TC, the 5B47-CUSTOM uniquely combines certified hazardous-area operation, factory-configurable linearization, screw-terminal field wiring, and hot-swap readiness - making it optimal for maintainable, safety-critical industrial analog I/O systems.
Availability
5B47-CUSTOM is available at Aetrix Electronics and suitable for industrial temperature monitoring, hazardous location process control, and legacy system retrofit requiring stable component supply, long-lifecycle support, and certified isolation performance.
Supply support for 5B47-CUSTOM includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Analog Devices is a global leader in high-performance analog, mixed-signal, and digital signal processing semiconductors, serving industrial, automotive, communications, and healthcare markets since 1965.
The 5B Series was engineered for rugged industrial signal conditioning - delivering transformer-isolated, linearized thermocouple and voltage input modules with FM/CSA hazardous-area approvals and automated manufacturing consistency.
FAQ
What thermocouple types does the 5B47-CUSTOM support?
The 5B47-CUSTOM supports J, K, T, E, R, S, and B thermocouple types. Unlike fixed-model variants (e.g., 5B47-K-05), the CUSTOM version allows user-defined input ranges and retains full hardware linearization for all supported types via internal polynomial correction circuitry - verified in the 5B47 Rev. 0 datasheet functional description and model table footnotes.
How is cold-junction compensation implemented in the 5B47-CUSTOM?
The 5B47-CUSTOM uses an internal cold-junction compensation (CJC) sensor with ±0.25°C initial accuracy at +25°C ambient. It relies on the AC1361 CJC sensor mounted on compatible 5B Series backplanes (e.g., 5B-01), referenced via Pin 1 (–EXC) and Pin 2 (LO). This architecture corrects parasitic thermocouple errors at the screw terminals without external components - confirmed in the GENERAL DESCRIPTION and Specifications sections of the 5B47 Rev. 0 datasheet.
Can the 5B47-CUSTOM be used in Class 1, Division 2 hazardous locations?
Yes, the 5B47-CUSTOM is approved by Factory Mutual (FM) and the Canadian Standards Association (CSA) for Class 1, Division 2, Groups A, B, C, and D locations. These certifications confirm its nonincendive operation - meaning it may be installed where flammable gases exist only under fault conditions, without requiring explosion-proof enclosures. This approval applies to the full 5B Series, including 5B47-CUSTOM, as stated on page 2 of the Rev. 0 datasheet.
What is the open-thermocouple detection behavior of the 5B47-CUSTOM?
The 5B47-CUSTOM provides an upscale open-input response: when the thermocouple is disconnected, the output rises above +4.9 V within 10 seconds. For downscale indication, a 20 MΩ, 0.25 W resistor must be externally connected across Pins 1 and 3. This behavior is inherent to the module's internal fault-detection circuitry and is independent of custom range configuration - documented on page 2 of the 5B47 Rev. 0 datasheet under "Accurate and System-Ready."
Does the 5B47-CUSTOM require external power supply filtering or regulation?
No, the 5B47-CUSTOM operates from a nominal +5 V ±5% supply and includes internal regulation. Its power supply sensitivity is specified as ±2 µV/% of Vs, and total supply current is 30 mA - allowing direct connection to standard 5B backplane power rails without added filtering. This design simplifies system integration and is validated across the –40°C to +85°C operating range per the Rev. 0 datasheet Electrical Specifications table.
5B47-CUSTOM Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Analog Devices Inc.
- Series:
- 5B47
- Packaging:
- Bulk
- Product Status:
- Active
- Amplifier Type:
- General Purpose
- Voltage - Supply:
- 4.75V ~ 5.25V
- Output Type:
- Analog
- Current - Supply:
- 30 mA
- Operating Temperature:
- -40°C ~ 85°C
- Mounting Type:
- Surface Mount
5B47-CUSTOM FAQ
1.How can I place an order for 5B47-CUSTOM through Aetrix?
Please submit a Request for Quotation (RFQ) for 5B47-CUSTOM on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for 5B47-CUSTOM reliable?
The price and inventory of 5B47-CUSTOM are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for 5B47-CUSTOM is usually 5 days.
3.What payment methods are accepted for 5B47-CUSTOM?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for 5B47-CUSTOM transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for 5B47-CUSTOM?
5B47-CUSTOM orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your 5B47-CUSTOM order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for 5B47-CUSTOM?
For technical support, including 5B47-CUSTOM datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your 5B47-CUSTOM requirements.
6.How does Aetrix verify that 5B47-CUSTOM is sourced from the original manufacturer or authorized distributors?
All 5B47-CUSTOM products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that 5B47-CUSTOM meets industry standards.
7.What is the process for return or replacement of 5B47-CUSTOM?
All 5B47-CUSTOM units undergo pre-shipment inspection (PSI). If there is an issue with 5B47-CUSTOM, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The 5B47-CUSTOM part is unused and in its original packaging.
Return procedure for 5B47-CUSTOM:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
5B47-CUSTOM Tags

-
SEN-13879
SparkFun Electronics

-
GA-311
Panasonic Industrial Automation Sales

-
E32-T11N 2M
Omron Automation and Safety

-
FX-501P
Panasonic Industrial Automation Sales

-
FX-501
Panasonic Industrial Automation Sales

-
E3X-HD44
Omron Automation and Safety

-
E3X-HD41 2M
Omron Automation and Safety

-
FX-502
Panasonic Industrial Automation Sales

-
ASTC0000
Red Lion Controls

-
E3X-HD11 2M
Omron Automation and Safety

-
E3NX-MA11
Omron Automation and Safety

-
ESPICO-ALL
PalmSens BV
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…