Product details
Overview
5B47-S-10-NI from Analog Devices is a single-channel, isolated, linearized thermocouple input signal conditioner for Type S thermocouples (+500°C to +1750°C), delivering 0 V to +5 V isolated output with ±2.4°C accuracy, 1500 Vrms continuous isolation, and 4 Hz bandwidth. It integrates cold-junction compensation, chopper-stabilized amplification (±1 µV/°C input offset drift), and 240 Vrms input protection for industrial temperature monitoring.
For engineers reviewing the 5B47-S-10-NI datasheet, 5B47-S-10-NI pinout, 5B47-S-10-NI application, or 5B47-S-10-NI equivalent, key selection considerations include its certified Class 1 Division 2 nonincendive rating, FM/CSA approvals, hot-swappable 5B-series compatibility, and precise linearized output for high-temperature furnace control and metallurgical process instrumentation.
Technical Context
The 5B47-S-10-NI implements transformer-based galvanic isolation with proprietary modulation for stable linear signal transfer, paired with internal cold-junction compensation using an on-board sensor to achieve ±0.25°C CJC accuracy at +25°C ambient. Its chopper-stabilized input amplifier ensures low-drift performance critical for long-term thermal stability in unattended systems.
It features multi-pole low-pass filtering (4 Hz –3 dB cutoff) delivering 60 dB normal-mode rejection at 60 Hz and 160 dB common-mode rejection with 1 kΩ source imbalance. The differential field-side input is fully floating-no input grounding required-and includes active open-thermocouple detection with upscale fail-safe response.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Input Type | Type S thermocouple (+500°C to +1750°C) |
| Output Range | 0 V to +5 V, isolated, low-impedance (50 Ω), RL > 50 kΩ |
| Accuracy | ±2.4°C system accuracy including CJC error at +25°C |
| Isolation Rating | 1500 Vrms continuous input-to-output; withstands 240 Vrms at screw terminals |
| Bandwidth | 4 Hz (–3 dB), enabling effective 60 Hz noise rejection in industrial environments |
| Temperature Drift | ±1 µV/°C input offset drift (≈0.168°C/°C for Type S), ±20 µV/°C output offset drift |
| Approvals | FM Class 1, Div 2, Groups A/B/C/D; CSA certified; EN50082-1 / EN50081-2 compliant |
Pinout & Package
Package: 2.275" × 2.375" × 0.595" (57.8 mm × 59.1 mm × 15.1 mm) potted module with standardized 5B-series footprint and screw-terminal field interface.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 (–EXC) | Excitation return / cold-junction reference | Provides return path for internal CJC sensor; connects to thermocouple negative leg in standard wiring |
| 2 (LO) | Low-side input terminal | Connects to thermocouple negative (–) lead; forms differential input pair with Pin 3 |
| 3 (HI) | High-side input terminal | Connects to thermocouple positive (+) lead; fully floating, no ground reference required |
| 4 (N/C) | No-connect | Not internally connected; left unconnected per design |
Key Features
| Feature | Design Value |
|---|---|
| Internal Linearization | Hardware-based linearization for Type S thermocouples eliminates need for external software correction across full +500°C to +1750°C range |
| Fail-Safe Open Detection | Automatic upscale output (≥+5 V) within 10 seconds of thermocouple break-enables immediate fault recognition without external circuitry |
| Hot-Swappable Compatibility | Identical mechanical and electrical interface with all 5B-series modules-allows live replacement without power-down or rewiring |
| Nonincendive Hazardous Location Rating | FM/CSA Class 1, Div 2 approval permits use in areas where flammable gases may be present only under fault conditions-no explosion-proof enclosure needed |
| EMI-Robust Signal Path | Meets EN50082-1 immunity: <0.1% FS error at 10 V/m, 1 GHz; RFI susceptibility limited to ±0.5% span error at 400 MHz, 5 W, 3 ft |
Applications
| Industrial Furnace Monitoring | Metallurgical Process Control |
|---|---|
Use Scenario: Continuous temperature measurement inside high-temperature kilns and annealing furnaces operating up to 1750°C. IC Role / Device Role / Timing Role: Isolated linearized signal conditioner converting raw Type S thermocouple mV output into stable, noise-immune 0–5 V analog signal for PLC or DCS input. Use Value: Eliminates cold-junction compensation errors and linearity corrections in software while maintaining ±2.4°C accuracy across extreme temperature gradients. | Use Scenario: Real-time temperature feedback in steel casting, heat-treating, and alloy production lines with high EMI and transient voltage exposure. IC Role / Device Role / Timing Role: Field-side signal isolator and protector that shields control room instrumentation from 240 Vrms faults and 60 Hz pickup in heavy-industrial settings. Use Value: Provides 1500 Vrms galvanic isolation and 160 dB CMR-ensuring measurement integrity despite ground loops and motor drive noise. |
| Refinery Catalyst Bed Sensing | Power Generation Boiler Monitoring |
Use Scenario: Distributed temperature profiling across catalytic reformer beds where hazardous gas presence mandates nonincendive-rated components. IC Role / Device Role / Timing Role: FM/CSA-certified signal conditioner enabling direct integration into Class 1, Div 2 control cabinets without additional barriers or enclosures. Use Value: Reduces system BOM cost and footprint by eliminating separate intrinsic safety barriers while meeting NEC/CEC requirements. | Use Scenario: Long-cable-run temperature sensing in coal- and gas-fired boiler walls, exposed to thermal cycling and RF interference from SCR drives. IC Role / Device Role / Timing Role: Low-drift (±1 µV/°C), filtered analog front-end with 4 Hz bandwidth that rejects combustion noise and SCR harmonics before digitization. Use Value: Delivers stable readings over time without recalibration-critical for predictive maintenance and efficiency optimization algorithms. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar thermocouple signal conditioning applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| 5B47-S-10 | Same core functionality and specifications, but lacks nickel-plated input terminals (NI suffix denotes Ni-plating for enhanced corrosion resistance in humid/harsh environments) | Unplated version suitable for dry, controlled indoor installations; NI variant required for refinery, marine, or high-humidity outdoor use | Select 5B47-S-10-NI when field wiring is exposed to moisture, salt spray, or chemical vapors requiring long-term terminal integrity |
| ADAM-4018 | 8-channel Ethernet-enabled RTU with built-in thermocouple inputs; no transformer isolation; 3000 VDC isolation via optocouplers only; ±3°C accuracy for Type S | Designed for networked distributed I/O, not backplane-integrated modular systems; requires external power and configuration software | Choose ADAM-4018 for IP-based SCADA deployments needing remote access; retain 5B47-S-10-NI for legacy 5B backplane integration and highest analog fidelity |
Compared with 5B47-S-10 and ADAM-4018, the 5B47-S-10-NI uniquely combines certified nonincendive operation, transformer-based 1500 Vrms isolation, and hardware linearization-making it the only option qualified for direct mounting in Class 1 Div 2 hazardous locations with uncompromised analog precision.
Availability
5B47-S-10-NI is available at Aetrix Electronics and suitable for industrial furnace monitoring, metallurgical process control, and refinery catalyst bed sensing requiring stable component supply, long-lifecycle support, and certified hazardous-area compliance.
Supply support for 5B47-S-10-NI includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Analog Devices is a global leader in high-performance analog, mixed-signal, and digital signal processing semiconductors, serving industrial, communications, automotive, and consumer markets since 1965.
The 5B Series was engineered specifically for rugged industrial signal conditioning-delivering transformer-isolated, linearized, and protected analog interfaces for thermocouples, RTDs, and voltage/current sensors in harsh, safety-critical environments.
FAQ
What is the purpose of the "-NI" suffix in 5B47-S-10-NI?
The "-NI" suffix indicates nickel-plated input screw terminals, which provide enhanced corrosion resistance for reliable long-term contact in high-humidity, chemically aggressive, or saline environments such as offshore platforms, refineries, or food processing plants. This plating prevents oxidation-induced resistance drift and maintains stable thermocouple connections-critical for maintaining the ±2.4°C accuracy of the 5B47-S-10-NI over decades of service.
Does 5B47-S-10-NI require external cold-junction compensation?
No. The 5B47-S-10-NI includes fully integrated, factory-calibrated cold-junction compensation (CJC) using an on-board sensor, achieving ±0.25°C accuracy at +25°C ambient. It automatically corrects for parasitic thermocouple voltages formed at the screw terminals, eliminating the need for external CJC hardware or software compensation-ensuring the full ±2.4°C system accuracy specification of the 5B47-S-10-NI is met out-of-the-box.
Can 5B47-S-10-NI be used in Class 1, Division 2 hazardous locations?
Yes. The 5B47-S-10-NI is FM and CSA certified for Class 1, Division 2, Groups A, B, C, and D-meaning it is approved for installation in areas where flammable gases may be present only under abnormal conditions. Its nonincendive design ensures no spark or thermal ignition hazard exists during normal operation, allowing direct use in control cabinets without additional explosion-proof enclosures-fully satisfying NEC Article 500 requirements for the 5B47-S-10-NI.
What is the maximum allowable common-mode voltage for 5B47-S-10-NI?
The 5B47-S-10-NI supports up to 1500 Vrms continuous common-mode voltage between field input and computer output sides. However, the output common must remain within ±3 V of the power supply common-exceeding this violates safe operating limits and risks damage. This constraint ensures signal integrity and protects downstream ADCs or PLC inputs when using the 5B47-S-10-NI in grounded measurement systems.
How does the 5B47-S-10-NI handle an open thermocouple condition?
The 5B47-S-10-NI detects open thermocouple circuits and responds with a predictable upscale output (>+5 V) within 10 seconds-providing immediate, unambiguous fault indication to the host system. No external components are needed; this behavior is inherent to the 5B47-S-10-NI's internal circuitry. For downscale response instead, a 20 MΩ resistor can be installed across terminals 1 and 3-a configurable feature unique to the 5B47-S-10-NI architecture.
5B47-S-10-NI Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Analog Devices Inc.
- Series:
- -
- Packaging:
- Tray
- Product Status:
- Obsolete
- Amplifier Type:
- Analog Output
- Voltage - Supply:
- 4.75V ~ 5.25V
- Output Type:
- Analog
- Current - Supply:
- 30 mA
- Operating Temperature:
- -40°C ~ 85°C
- Mounting Type:
- Surface Mount
5B47-S-10-NI FAQ
1.How can I place an order for 5B47-S-10-NI through Aetrix?
Please submit a Request for Quotation (RFQ) for 5B47-S-10-NI on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for 5B47-S-10-NI reliable?
The price and inventory of 5B47-S-10-NI are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for 5B47-S-10-NI is usually 5 days.
3.What payment methods are accepted for 5B47-S-10-NI?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for 5B47-S-10-NI transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for 5B47-S-10-NI?
5B47-S-10-NI orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your 5B47-S-10-NI order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for 5B47-S-10-NI?
For technical support, including 5B47-S-10-NI datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your 5B47-S-10-NI requirements.
6.How does Aetrix verify that 5B47-S-10-NI is sourced from the original manufacturer or authorized distributors?
All 5B47-S-10-NI products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that 5B47-S-10-NI meets industry standards.
7.What is the process for return or replacement of 5B47-S-10-NI?
All 5B47-S-10-NI units undergo pre-shipment inspection (PSI). If there is an issue with 5B47-S-10-NI, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The 5B47-S-10-NI part is unused and in its original packaging.
Return procedure for 5B47-S-10-NI:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
5B47-S-10-NI Tags

-
SEN-13879
SparkFun Electronics

-
GA-311
Panasonic Industrial Automation Sales

-
E32-T11N 2M
Omron Automation and Safety

-
FX-501P
Panasonic Industrial Automation Sales

-
FX-501
Panasonic Industrial Automation Sales

-
E3X-HD44
Omron Automation and Safety

-
E3X-HD41 2M
Omron Automation and Safety

-
FX-502
Panasonic Industrial Automation Sales

-
ASTC0000
Red Lion Controls

-
E3X-HD11 2M
Omron Automation and Safety

-
E3NX-MA11
Omron Automation and Safety

-
ESPICO-ALL
PalmSens BV
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…