Altech Corporation KJ4-M18MB80-ANU-X0409
- Part No.:
- KJ4-M18MB80-ANU-X0409
- Manufacturer:
- Altech Corporation
- Category:
- Proximity Sensors - Industrial
- Package:
- Cylinder, Threaded - M18
- Datasheet:
-
KJ4-M18MB80-ANU-X0409.pdf
- Description:
- SENSOR PROX INDUCTIVE 1-4MM CYL
- Quantity:
- Payment:

- Shipping:

Inventory:3,783
Please send an inquiry. Send us your inquiry, and we will respond immediately.
KJ4-M18MB80-ANU-X0409 Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Altech Corporation
- Series:
- -
- Package/Case:
- Cylinder, Threaded - M18
- Packaging:
- Box
- Product Status:
- Active
- Sensor Type:
- Inductive
- Sensing Distance:
- 0.039" ~ 0.157" (1mm ~ 4mm)
- Output Type:
- Analog Voltage
- Response Frequency:
- 100Hz
- Shielding:
- Shielded
- Material - Body:
- Nickel-Plated Brass
- Voltage - Supply:
- 18V ~ 30V
- Termination Style:
- Cable Leads
- Operating Temperature:
- -25°C ~ 70°C (TA)
- Ingress Protection:
- IP67
- Indicator:
- No Indicator
KJ4-M18MB80-ANU-X0409 FAQ
1.How can I place an order for KJ4-M18MB80-ANU-X0409 through Aetrix?
Please submit a Request for Quotation (RFQ) for KJ4-M18MB80-ANU-X0409 on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for KJ4-M18MB80-ANU-X0409 reliable?
The price and inventory of KJ4-M18MB80-ANU-X0409 are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for KJ4-M18MB80-ANU-X0409 is usually 5 days.
3.What payment methods are accepted for KJ4-M18MB80-ANU-X0409?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for KJ4-M18MB80-ANU-X0409 transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for KJ4-M18MB80-ANU-X0409?
KJ4-M18MB80-ANU-X0409 orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your KJ4-M18MB80-ANU-X0409 order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for KJ4-M18MB80-ANU-X0409?
For technical support, including KJ4-M18MB80-ANU-X0409 datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your KJ4-M18MB80-ANU-X0409 requirements.
6.How does Aetrix verify that KJ4-M18MB80-ANU-X0409 is sourced from the original manufacturer or authorized distributors?
All KJ4-M18MB80-ANU-X0409 products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that KJ4-M18MB80-ANU-X0409 meets industry standards.
7.What is the process for return or replacement of KJ4-M18MB80-ANU-X0409?
All KJ4-M18MB80-ANU-X0409 units undergo pre-shipment inspection (PSI). If there is an issue with KJ4-M18MB80-ANU-X0409, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The KJ4-M18MB80-ANU-X0409 part is unused and in its original packaging.
Return procedure for KJ4-M18MB80-ANU-X0409:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
KJ4-M18MB80-ANU-X0409 Tags
-
E2B-M12KS04-M1-C1
Omron Automation and Safety

-
GX-F12A
Panasonic Industrial Automation Sales

-
GX-H8A
Panasonic Industrial Automation Sales

-
GX-F12A-P
Panasonic Industrial Automation Sales

-
GX-F6A
Panasonic Industrial Automation Sales

-
GX-F8A
Panasonic Industrial Automation Sales

-
GX-F8A-P
Panasonic Industrial Automation Sales

-
GX-F12B-P
Panasonic Industrial Automation Sales

-
GX-F8B
Panasonic Industrial Automation Sales

-
GX-F12B
Panasonic Industrial Automation Sales

-
GX-H6A
Panasonic Industrial Automation Sales

-
GX-H8A-P
Panasonic Industrial Automation Sales
Tech Hub
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…
LDO regulator guide covering low dropout voltage, power dissipation, thermal design, PSRR, output noise, capacitor stability, adjustable LDO circuits, LDO vs buck converter and datasheet selection chec…
Conditional Access Module guide covering CAM meaning, CI/CI+ interface, smart card authorization, DVB security workflow, TV and set-top box compatibility, internal electronics, ESD protection, connecto…
Guide to electronic component obsolescence covering EOL risk, PCN/PDN notices, last-time buy planning, replacement options, form-fit-function validation, counterfeit risk and BOM lifecycle management.
18650 battery guide covering lithium-ion cell basics, 3.6V/3.7V voltage, 4.2V charging, mAh and Wh capacity, protected cells, chargers, BMS, series-parallel packs, holders, welding and sourcing checks.…
Hall effect sensor guide covering working principle, linear and digital sensors, Arduino circuits, current sensing, speed detection, automotive applications, A3144 examples, signal filtering and datash…
Product Change Notification guide for electronic components, covering PCN meaning, PCN vs PDN/EOL, common change types, risk levels, form-fit-function review, engineering validation, BOM control, LTB/L…
A practical guide to blend door actuators, covering HVAC function, symptoms, location, AC and heater issues, reset and calibration, replacement cost, electrical diagnosis, compatibility checks, and rep…
Engineering guide to Raspberry Pi alternatives, covering chip-level differences, Orange Pi, ROCK, Jetson, Banana Pi, NanoPi, Compute Module, Pico, GPIO, camera, HAT compatibility, and replacement risks…
Engineering guide to dynamic load response testing for high-current buck converters, covering load step setup, slew rate, Vcore undershoot, overshoot, recovery time, probe location, output capacitors a…