Riedon products by Bourns A3T-250
- Part No.:
- A3T-250
- Manufacturer:
- Riedon products by Bourns
- Category:
- Electrical, Specialty Fuses
- Package:
- Cylindrical, Blade Terminal (Bolt)
- Datasheet:
-
A3T-250.pdf
- Description:
- FUSE CRTRDGE 250A 300VAC/125VDC
- Quantity:
- Payment:

- Shipping:

Inventory:849
Please send an inquiry. Send us your inquiry, and we will respond immediately.
A3T-250 Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Riedon products by Bourns
- Series:
- A3T
- Package / Case:
- Cylindrical, Blade Terminal (Bolt)
- Packaging:
- Bulk
- Product Status:
- Active
- Mounting Type:
- Bolt Mount
- Fuse Type:
- Cartridge
- Current Rating (Amps):
- 250A
- Voltage Rating - AC:
- 300 VAC
- Voltage Rating - DC:
- 160 VDC
- Response Time:
- Fast Blow
- Applications:
- Electrical, Industrial
- Features:
- -
- Class:
- T
- Approval Agency:
- CSA, UL
- Operating Temperature:
- -
- Breaking Capacity @ Rated Voltage:
- 200kA AC, 50kA DC
- Size / Dimension:
- 1.331" Dia x 0.839" L (33.80mm x 21.30mm)
- Grade:
- -
- Qualification:
- -
A3T-250 FAQ
1.How can I place an order for A3T-250 through Aetrix?
Please submit a Request for Quotation (RFQ) for A3T-250 on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for A3T-250 reliable?
The price and inventory of A3T-250 are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for A3T-250 is usually 5 days.
3.What payment methods are accepted for A3T-250?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for A3T-250 transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for A3T-250?
A3T-250 orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your A3T-250 order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for A3T-250?
For technical support, including A3T-250 datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your A3T-250 requirements.
6.How does Aetrix verify that A3T-250 is sourced from the original manufacturer or authorized distributors?
All A3T-250 products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that A3T-250 meets industry standards.
7.What is the process for return or replacement of A3T-250?
All A3T-250 units undergo pre-shipment inspection (PSI). If there is an issue with A3T-250, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The A3T-250 part is unused and in its original packaging.
Return procedure for A3T-250:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
A3T-250 Tags

-
04611.25ER
Littelfuse Inc.

-
0461.500ER
Littelfuse Inc.

-
0461002.ER
Littelfuse Inc.

-
0308.750UR
Littelfuse Inc.
-
0159002.MR
Littelfuse Inc.

-
ITV4030L0812NR
Littelfuse Inc.

-
BK/GMT-7-1/2A
Eaton - Bussmann Electrical Division

-
0242.100UAT1
Littelfuse Inc.

-
BK/GMT-15A
Eaton - Bussmann Electrical Division

-
0242.050UAT1
Littelfuse Inc.

-
0242.200UAT1
Littelfuse Inc.
-
0242.100UR
Littelfuse Inc.
Tech Hub
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…
LDO regulator guide covering low dropout voltage, power dissipation, thermal design, PSRR, output noise, capacitor stability, adjustable LDO circuits, LDO vs buck converter and datasheet selection chec…
Conditional Access Module guide covering CAM meaning, CI/CI+ interface, smart card authorization, DVB security workflow, TV and set-top box compatibility, internal electronics, ESD protection, connecto…
Guide to electronic component obsolescence covering EOL risk, PCN/PDN notices, last-time buy planning, replacement options, form-fit-function validation, counterfeit risk and BOM lifecycle management.
18650 battery guide covering lithium-ion cell basics, 3.6V/3.7V voltage, 4.2V charging, mAh and Wh capacity, protected cells, chargers, BMS, series-parallel packs, holders, welding and sourcing checks.…
Hall effect sensor guide covering working principle, linear and digital sensors, Arduino circuits, current sensing, speed detection, automotive applications, A3144 examples, signal filtering and datash…
Product Change Notification guide for electronic components, covering PCN meaning, PCN vs PDN/EOL, common change types, risk levels, form-fit-function review, engineering validation, BOM control, LTB/L…
A practical guide to blend door actuators, covering HVAC function, symptoms, location, AC and heater issues, reset and calibration, replacement cost, electrical diagnosis, compatibility checks, and rep…
Engineering guide to Raspberry Pi alternatives, covering chip-level differences, Orange Pi, ROCK, Jetson, Banana Pi, NanoPi, Compute Module, Pico, GPIO, camera, HAT compatibility, and replacement risks…