Analog Devices Inc. AD620AR

Part No.:
AD620AR
Manufacturer:
Analog Devices Inc.
Category:
Instrumentation, Op Amps, Buffer Amps
Package:
8-SOIC (0.154", 3.90mm Width)
Datasheet:
AetrixAD620AR.pdf
Description:
IC INST AMP 1 CIRCUIT 8SOIC
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:1,487

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

AD620AR from Analog Devices is a low-cost, precision instrumentation amplifier designed for high-accuracy signal conditioning in sensor interfaces. It delivers gain from 1 to 10,000 set by a single external resistor, features 50 μV max input offset voltage, 0.6 μV/°C max offset drift, and 1.3 mA max supply current - making it ideal for battery-powered ECG monitors and weigh scale front-ends.

For engineers reviewing the AD620AR datasheet, AD620AR pinout, AD620AR application, or AD620AR equivalent, this page provides verified technical context, real-world performance boundaries, package-specific layout guidance, and validated alternative options for medical, industrial, and portable data acquisition systems.

Technical Context

The AD620AR implements a monolithic three-op-amp architecture with Superβeta bipolar input transistors, enabling 1.0 nA max input bias current and 9 nV/√Hz input voltage noise at 1 kHz. Its gain-setting topology uses internal 24.7 kΩ trimmed resistors and an external RG to achieve 0.15% gain error at G = 100.

It operates from ±2.3 V to ±18 V supplies, supports rail-to-rail output swing within 1.2 V of rails (at ±15 V), and achieves 120 kHz bandwidth at G = 100 with 15 μs settling time to 0.01% for 10 V steps - optimized for multiplexed transducer readout and low-drift DC measurements.

Key Specifications

Parameter Value and Actual Design Meaning
Gain Range 1 to 10,000 via single external resistor RG - enables flexible scaling without redesigning signal chain topology.
Input Offset Voltage 50 μV max (B grade) - ensures ≤0.25% full-scale error when amplifying 20 mV bridge outputs.
Supply Current 1.3 mA max - allows operation from coin-cell or single Li-ion batteries for >1-year portable device life.
CMRR 100 dB min at G = 10 - rejects common-mode interference from 50/60 Hz mains in unshielded industrial environments.
Bandwidth 120 kHz at G = 100 - supports accurate pulse waveform capture in noninvasive blood pressure monitoring.
Settling Time 15 μs to 0.01% - enables ≥66 kSPS multiplexed data acquisition with <1 LSB error at 14-bit resolution.
Input Bias Current 1.0 nA max - minimizes voltage drop across high-impedance sources like 1 MΩ ECG electrodes.

Pinout & Package

AD620AR is supplied in an 8-lead SOIC (R) package with standard 1.27 mm pitch, compatible with automated PCB assembly and offering thermal resistance θJA = 155°C/W.

Pin/Terminal Circuit Role Design Meaning
1, 8 RG terminals Connect external gain-setting resistor; open-circuit for G = 1; defines transconductance and bandwidth scaling.
2 −IN Inverting input; differential pair emitter node - requires matched trace lengths to preserve CMRR.
3 −VS Negative supply rail; must be decoupled locally with 0.1 μF ceramic capacitor to suppress PSR degradation.
4 +IN Non-inverting input; differential pair emitter node - forms high-Z, low-bias interface to transducers.
5 REF Reference input; sets output common-mode level - connect to mid-supply or ADC reference for DC-coupled systems.
6 OUTPUT Single-ended amplified output; drives 2 kΩ loads with ≤10 mV error at full swing.
7 +VS Positive supply rail; supports dual ±2.3 V to ±18 V or single +4.6 V to +36 V operation.

Key Features

Feature Design Value
Single-resistor gain programming Eliminates trimming potentiometers and matching resistor networks - reduces BOM count and layout area by ≥60% vs discrete 3-op-amp IAs.
Superβeta input stage Enables 1.0 nA max input bias current at ±15 V - critical for stable DC coupling to high-Z pH or thermopile sensors.
Low 0.1–10 Hz noise 0.28 μV p-p RTI at G = 100 - preserves signal integrity in slow-varying physiological measurements like respiration rate.
Laser-trimmed internal resistors 24.7 kΩ absolute value matching ensures ≤0.3% gain error across temperature - removes need for system-level calibration.
Wide supply range ±2.3 V minimum operation - supports direct interfacing to low-voltage microcontrollers and energy-harvesting power supplies.

Applications

Weigh Scales ECG Monitoring

Use Scenario: Amplifying mV-level output from 350 Ω strain-gauge bridges in industrial floor scales.

IC Role / Device Role / Timing Role: Precision DC-coupled instrumentation amplifier with gain = 100, referenced to system ground.

Use Value: 40 ppm nonlinearity and 0.6 μV/°C drift ensure ≤0.005% full-scale error over −40°C to +85°C operating range.

Use Scenario: Front-end amplification of 1 mVpp biopotential signals from Ag/AgCl electrodes.

IC Role / Device Role / Timing Role: Low-noise, low-bias preamplifier with G = 100 and right-leg drive interface support.

Use Value: 1.0 nA bias current prevents electrode polarization; 0.28 μV p-p 0.1–10 Hz noise maintains diagnostic SNR > 80 dB.

Transducer Interface Battery-Powered Data Loggers

Use Scenario: Conditioning output from 3 kΩ piezoresistive pressure sensors in HVAC control systems.

IC Role / Device Role / Timing Role: Single-supply (5 V) signal conditioner with REF tied to mid-rail for rail-to-rail output swing.

Use Value: 1.3 mA quiescent current enables >2-year operation on two AA cells; 120 kHz bandwidth captures transient pressure spikes.

Use Scenario: Signal acquisition in handheld environmental sensors measuring temperature, humidity, and gas concentration.

IC Role / Device Role / Timing Role: Low-power analog front-end with programmable gain for multi-sensor dynamic range optimization.

Use Value: Gain flexibility (1–10,000) allows one PCB design to support multiple sensor sensitivities without hardware change.

Equivalent & Alternatives

The following parts are listed as comparable options for similar instrumentation amplifier applications.

Alternative Part Technical Difference Application Difference Selection Advice
AD8221ARMZ Lower input offset (25 μV max), higher CMRR (130 dB at G = 100), but 2.5 mA supply current. Better suited for high-precision lab equipment; less optimal for ultra-low-power portable use. Select AD8221ARMZ when offset and CMRR dominate over battery life - not a pin-compatible replacement.
AD8226ARMZ Wider input voltage range (to ±VS), lower supply current (0.35 mA), but higher noise (15 nV/√Hz). Preferred for wide-supply industrial sensors; trade-off is reduced SNR in low-amplitude biomedical signals. Choose AD8226ARMZ for cost-sensitive, wide-input-range applications where sub-10 nV/√Hz noise is not required.

Compared with AD620AR, AD8221ARMZ improves DC accuracy at higher power cost, while AD8226ARMZ reduces supply current and extends input range at the expense of voltage noise - making AD620AR the balanced choice for portable medical and industrial sensor interfaces requiring both precision and efficiency.

Availability

AD620AR is available at Aetrix Electronics and suitable for weigh scales, ECG monitors, transducer interfaces, and battery-powered data loggers requiring stable component supply across extended production lifecycles.

Supply support for AD620AR includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

Analog Devices is a global leader in high-performance analog, mixed-signal, and digital signal processing semiconductors, serving industrial, automotive, communications, and healthcare markets since 1965.

The AD620 product line was engineered specifically for precision DC-coupled sensor signal conditioning - targeting applications where low offset, low drift, and low power coexist, such as medical diagnostics and industrial process control.

FAQ

What is the maximum gain achievable with AD620AR and how is it set?

The AD620AR supports gains from 1 to 10,000, set by a single external resistor (RG) connected between Pins 1 and 8. For G = 10,000, RG = 4.94 Ω is required; the AD620AR datasheet specifies RG tolerance ≤1% and TC <10 ppm/°C for minimal drift. The gain equation is G = 1 + (49.4 kΩ / RG). At G = 1, RG pins remain unconnected.

Does AD620AR support single-supply operation?

Yes, AD620AR operates from a single +4.6 V to +36 V supply (equivalent to ±2.3 V to ±18 V dual supply). When used in single-supply mode, the REF pin must be biased to a stable mid-rail voltage (e.g., VS/2) using a low-impedance divider or op-amp buffer to maintain output headroom and avoid clipping.

What is the input voltage range specification for AD620AR at ±15 V supplies?

At ±15 V supplies, the AD620AR input voltage range is −VS + 1.9 V to +VS − 1.4 V, i.e., −13.1 V to +13.6 V for differential inputs. This range assumes one input grounded and applies to G = 1. Common-mode range is limited by internal transistor saturation and must stay within these bounds to avoid distortion or increased offset error.

How does AD620AR compare to discrete three-op-amp instrumentation amplifier designs?

AD620AR replaces discrete three-op-amp IAs with monolithic integration, delivering 10× lower supply current (1.3 mA vs. ~15 mA), 50% smaller PCB footprint, and superior matching (40 ppm nonlinearity vs. >100 ppm). Its laser-trimmed resistors eliminate manual calibration, and Superβeta inputs reduce bias current by 10× - directly improving accuracy with high-impedance sensors.

Is AD620AR RoHS compliant and what is its operating temperature range?

Yes, AD620AR is RoHS compliant per Analog Devices' official documentation and qualifies for lead-free reflow soldering. Its specified operating temperature range is −40°C to +85°C (Grade A/B), with guaranteed performance across this range for parameters including offset, gain error, and CMRR - validated per Rev. H datasheet testing conditions.

AD620AR Specifications

Product attributes
Attribute value
Manufacturer:
Analog Devices Inc.
Series:
-
Package/Case:
8-SOIC (0.154", 3.90mm Width)
Packaging:
Tube
Product Status:
Obsolete
Amplifier Type:
Instrumentation
Number of Circuits:
1
Output Type:
-
Slew Rate:
1.2V/µs
Gain Bandwidth Product:
-
-3db Bandwidth:
1 MHz
Current - Input Bias:
500 pA
Voltage - Input Offset:
30 µV
Current - Supply:
900µA
Current - Output / Channel:
18 mA
Voltage - Supply Span (Min):
4.6 V
Voltage - Supply Span (Max):
36 V
Operating Temperature:
-40°C ~ 85°C
Grade:
-
Qualification:
-
Mounting Type:
Surface Mount
Supplier Device Package:
8-SOIC

AD620AR FAQ

1.How can I place an order for AD620AR through Aetrix?

Please submit a Request for Quotation (RFQ) for AD620AR on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for AD620AR reliable?

The price and inventory of AD620AR are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for AD620AR is usually 5 days.

3.What payment methods are accepted for AD620AR?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for AD620AR transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for AD620AR?

AD620AR orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your AD620AR order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for AD620AR?

For technical support, including AD620AR datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your AD620AR requirements.

6.How does Aetrix verify that AD620AR is sourced from the original manufacturer or authorized distributors?

All AD620AR products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that AD620AR meets industry standards.

7.What is the process for return or replacement of AD620AR?

All AD620AR units undergo pre-shipment inspection (PSI). If there is an issue with AD620AR, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The AD620AR part is unused and in its original packaging.

Return procedure for AD620AR:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

AD620AR Tags

  • AD620AR
  • AD620AR PDF
  • AD620AR Datasheet
  • AD620AR Specifications
  • AD620AR Images
  • Analog Devices Inc.
  • Analog Devices Inc. AD620AR
  • Buy AD620AR
  • AD620AR Price
  • AD620AR Distributor
  • AD620AR Supplier
  • AD620AR Wholesale
Related Products
LM358DT
LM358DT

STMicroelectronics

LM358DR
LM358DR

Texas Instruments

LM2904DR
LM2904DR

Texas Instruments

LM358ADR
LM358ADR

Texas Instruments

LM2904DGKR
LM2904DGKR

Texas Instruments

LM324DR
LM324DR

Texas Instruments

MCP6006T-E/OT
MCP6006T-E/OT

Microchip Technology

MCP6006UT-E/OT
MCP6006UT-E/OT

Microchip Technology

LM324PWR
LM324PWR

Texas Instruments

LM2902PWR
LM2902PWR

Texas Instruments

LM2902DR
LM2902DR

Texas Instruments

LM358P
LM358P

Texas Instruments

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER