Analog Devices Inc. ADG5462FBRUZ-RL7
- Part No.:
- ADG5462FBRUZ-RL7
- Manufacturer:
- Analog Devices Inc.
- Category:
- Mixed Technology
- Package:
- 16-TSSOP (0.173", 4.40mm Width)
- Datasheet:
-
ADG5462FBRUZ-RL7.pdf
- Description:
- TVS DEVICE MIXED 16-TSSOP
- Quantity:
- Payment:

- Shipping:

Inventory:2,980
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
ADG5462FBRUZ-RL7 from Analog Devices is a quad-channel, user-configurable overvoltage-protected analog switch with 10 Ω typical on-resistance, ±55 V fault protection on source pins (S1–S4), and integrated fault detection via FF flag output. It operates from ±5 V to ±22 V dual supply or 8 V to 44 V single supply, and is used in industrial data acquisition systems where signal path integrity must be maintained under miswiring or power sequencing faults.
For engineers reviewing the ADG5462FBRUZ-RL7 datasheet, ADG5462FBRUZ-RL7 pinout, ADG5462FBRUZ-RL7 application, or ADG5462FBRUZ-RL7 equivalent, key selection criteria include its user-defined POSFV/NEGFV fault thresholds, 460 ns overvoltage response time (±15 V), latch-up immunity, and 4 kV HBM ESD rating - all critical for ruggedized analog front-end design.
Technical Context
The ADG5462FBRUZ-RL7 implements trench-isolated channel protectors placed in series with each analog signal path (Sx to Dx), enabling bidirectional operation and blocking input overvoltages up to ±55 V relative to ground - both when powered and unpowered. Its protection level is set by externally applied secondary supplies (POSFV and NEGFV), independent of primary VDD/VSS rails.
Fault detection is implemented via the FF digital output pin, which asserts low during any Sx overvoltage event, while DR pin control determines whether the affected drain (Dx) is pulled to POSFV or NEGFV during fault. Threshold voltage VT is fixed at 0.7 V typ, ensuring consistent turn-off behavior across temperature and supply conditions.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| On Resistance (RON) | 10 Ω typical at ±15 V; ensures minimal signal attenuation and thermal drift in precision measurement paths. |
| Overvoltage Protection Range | ±55 V on Sx pins vs. GND; blocks catastrophic transients without external clamping diodes. |
| Overvoltage Response Time | 460 ns typical (±15 V); enables real-time fault isolation before downstream circuit damage occurs. |
| Supply Range | ±5 V to ±22 V dual or 8 V to 44 V single; supports wide industrial and avionics rail flexibility. |
| ESD Rating | 4 kV HBM on all I/O pins; eliminates need for external ESD protection in board-level layout. |
| Fault Flag Output (FF) | Active-low open-drain interrupt; allows wired-OR fault aggregation across multi-channel modules. |
| On-Resistance Flatness | 0.5 Ω max over signal range; preserves linearity and THD+N < 0.0015% in instrumentation applications. |
Pinout & Package
ADG5462FBRUZ-RL7 is packaged in a 16-lead TSSOP (RU-16) with exposed pad. Pin 1 = NEGFV, Pin 2 = D1, Pin 3 = S1, Pin 4 = VSS, Pin 5 = GND, Pin 6 = S4, Pin 7 = D4, Pin 8 = DR, Pin 9 = NIC, Pin 10 = D3, Pin 11 = S3, Pin 12 = FF, Pin 13 = VDD, Pin 14 = S2, Pin 15 = D2, Pin 16 = POSFV. Exposed pad must be soldered to VSS for thermal and reliability compliance.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| NEGFV (Pin 1) | Negative fault voltage reference | Sets lower overvoltage trip threshold; connect to VSS if no secondary negative supply is used. |
| S1–S4 (Pins 3,6,11,14) | Protected source terminals | Input/output nodes with ±55 V fault tolerance; high-impedance when overvoltage detected. |
| D1–D4 (Pins 2,7,10,15) | Drain terminals | Signal path outputs; pulled to POSFV/NEGFV during fault only if DR is driven low. |
| DR (Pin 8) | Fault response control | Low = enable active fault clamping; floating/high = open-circuit drain during fault. |
| FF (Pin 12) | Fault flag output | Active-low interrupt indicating any Sx overvoltage; internally weak-pull-up for bus sharing. |
| POSFV (Pin 16) | Positive fault voltage reference | Sets upper overvoltage trip threshold; connect to VDD if no secondary positive supply is used. |
Key Features
| Feature | Design Value |
|---|---|
| User-defined fault thresholds | Independent POSFV/NEGFV pins allow precise overvoltage trip setting beyond primary supply rails. |
| Power-off protection | Maintains ±55 V fault blocking even with VDD/VSS unpowered - critical for hot-swap and sequencing-insensitive systems. |
| Latch-up immunity | Trench isolation architecture prevents destructive latch-up under fault stress or ESD events. |
| Low RON flatness | 0.5 Ω max variation across signal range ensures < 0.0015% THD+N for high-fidelity data acquisition. |
| Interrupt-driven fault reporting | FF pin provides system-level visibility into channel faults without polling or software overhead. |
Applications
| Analog Input Modules | Process Control Systems |
|---|---|
Use Scenario: Industrial PLC analog input cards handling multiple sensor types (RTD, thermocouple, 4–20 mA) in electrically noisy environments. IC Role / Device Role / Timing Role: Quad-channel protector isolating each sensor input from field wiring faults and ground loops. Use Value: Eliminates need for discrete TVS diodes and op-amp input protection, reducing BOM count and PCB area by >30%. |
Use Scenario: Distributed control system (DCS) I/O modules deployed in chemical plant field cabinets with unpredictable grounding and transient exposure. IC Role / Device Role / Timing Role: Signal path guard between field wiring and ADC front-end, enforcing ±55 V fault containment. Use Value: Enables maintenance-free operation over 15+ years by preventing cumulative degradation from repeated sub-threshold overvoltages. |
| Data Acquisition Systems | Avionics Test Equipment |
Use Scenario: High-channel-count DAQ chassis acquiring synchronized voltage/current measurements from mixed-signal sources. IC Role / Device Role / Timing Role: Channel-by-channel overvoltage gate preceding multiplexer and precision amplifier stages. Use Value: Preserves 16-bit ENOB by limiting on-resistance variation to 0.5 Ω and THD+N to 0.0015% across full input range. |
Use Scenario: Built-in test equipment (BITE) for aircraft flight control sensors requiring MIL-STD-704 compliant surge resilience. IC Role / Device Role / Timing Role: Fault-tolerant interface between sensor harnesses and ATE signal conditioning circuits. Use Value: Meets DO-160 Section 22 Level 3 induced transient immunity without external clamp networks. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar overvoltage-protected analog switch applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| ADG5412FBRUZ-RL7 | Quad SPST (vs. ADG5462F's configurable quad channel); identical RON, fault range, and FF/DR logic. | No DR-controlled fault clamping - drain remains open during fault; suitable only where passive isolation suffices. | Select when system-level fault response does not require active pull-down/pull-up of Dx pins. |
| MAX14662ETE+ | Single-supply only (4.5 V to 36 V); 12 Ω RON; no user-defined fault thresholds - fixed ±20 V protection. | Lacks dual-supply support and programmable POSFV/NEGFV; limited to grounded-referenced systems. | Select for cost-sensitive, single-rail designs where ±20 V fault coverage meets requirements. |
Compared with ADG5462FBRUZ-RL7, ADG5412FBRUZ-RL7 offers identical protection but omits DR-controlled fault clamping, while MAX14662ETE+ trades configurability for lower cost and single-supply simplicity - making ADG5462FBRUZ-RL7 the only option supporting user-defined ±55 V thresholds with active fault response in dual- or single-supply systems.
Availability
ADG5462FBRUZ-RL7 is available at Aetrix Electronics and suitable for analog input modules, process control systems, and data acquisition requiring stable component supply across extended temperature ranges (−40°C to +125°C) and long-lifecycle industrial programs.
Supply support for ADG5462FBRUZ-RL7 includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Analog Devices is a global leader in high-performance analog, mixed-signal, and DSP technologies, serving industrial, automotive, communications, and aerospace markets with precision signal processing solutions.
The ADG5462F product line delivers fault-protected analog switching for harsh-environment signal chains, designed specifically to eliminate external protection components while maintaining nanovolt-level signal integrity in data acquisition and control systems.
FAQ
What is the maximum continuous current per channel for ADG5462FBRUZ-RL7?
The ADG5462FBRUZ-RL7 supports up to 83 mA continuous current per channel at 25°C in TSSOP package when the signal is biased within VSS + 4.5 V to VDD − 4.5 V. At +125°C, this derates to 39 mA. The LFCSP variant supports higher current (152 mA at 25°C) due to lower thermal resistance (θJA = 30.4°C/W). These values are specified in Table 5 of the ADG5462F datasheet Rev. C.
Does ADG5462FBRUZ-RL7 require external power supply sequencing?
No - ADG5462FBRUZ-RL7 provides power-off protection, meaning it blocks ±55 V faults on Sx pins even when VDD and VSS are unpowered or floating. This eliminates dependency on strict supply ramp ordering, making it ideal for systems where primary and secondary supplies may power up/down asynchronously.
How does the DR pin affect fault behavior in ADG5462FBRUZ-RL7?
When DR is driven low, the affected drain pin (Dx) is actively pulled to either POSFV or NEGFV depending on which fault threshold was exceeded. If DR is left floating or tied to VDD, Dx remains in high-impedance state during fault. This selective clamping capability is unique to ADG5462FBRUZ-RL7 and enables controlled fault current routing in safety-critical systems.
Can ADG5462FBRUZ-RL7 operate with asymmetric dual supplies?
Yes - ADG5462FBRUZ-RL7 supports asymmetric dual supplies as long as VDD − VSS ≤ 48 V and both rails remain within absolute maximum ratings (VDD to GND ≤ +48 V, VSS to GND ≥ −48 V). For example, VDD = +20 V and VSS = −5 V is valid, enabling custom fault threshold alignment in mixed-voltage systems.
What is the role of the NIC pin (Pin 9) on ADG5462FBRUZ-RL7?
Pin 9 is Not Internally Connected (NIC) and must remain unconnected in the ADG5462FBRUZ-RL7 TSSOP layout. It serves no electrical function and has no internal bond wire or silicon connection. Leaving it floating poses no risk, but routing traces or vias to it is unnecessary and may compromise mechanical reliability.
ADG5462FBRUZ-RL7 Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Analog Devices Inc.
- Package/Case:
- 16-TSSOP (0.173", 4.40mm Width)
- Series:
- -
- Packaging:
- Tape & Reel (TR)
- Product Status:
- Active
- Voltage - Clamping:
- -
- Technology:
- Mixed Technology
- Number of Circuits:
- 4
- Applications:
- General Purpose
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Surface Mount
- Supplier Device Package:
- 16-TSSOP
ADG5462FBRUZ-RL7 FAQ
1.How can I place an order for ADG5462FBRUZ-RL7 through Aetrix?
Please submit a Request for Quotation (RFQ) for ADG5462FBRUZ-RL7 on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for ADG5462FBRUZ-RL7 reliable?
The price and inventory of ADG5462FBRUZ-RL7 are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for ADG5462FBRUZ-RL7 is usually 5 days.
3.What payment methods are accepted for ADG5462FBRUZ-RL7?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for ADG5462FBRUZ-RL7 transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for ADG5462FBRUZ-RL7?
ADG5462FBRUZ-RL7 orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your ADG5462FBRUZ-RL7 order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for ADG5462FBRUZ-RL7?
For technical support, including ADG5462FBRUZ-RL7 datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your ADG5462FBRUZ-RL7 requirements.
6.How does Aetrix verify that ADG5462FBRUZ-RL7 is sourced from the original manufacturer or authorized distributors?
All ADG5462FBRUZ-RL7 products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that ADG5462FBRUZ-RL7 meets industry standards.
7.What is the process for return or replacement of ADG5462FBRUZ-RL7?
All ADG5462FBRUZ-RL7 units undergo pre-shipment inspection (PSI). If there is an issue with ADG5462FBRUZ-RL7, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The ADG5462FBRUZ-RL7 part is unused and in its original packaging.
Return procedure for ADG5462FBRUZ-RL7:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
ADG5462FBRUZ-RL7 Tags

-
ESD03A5V5R17V
Stackpole Electronics Inc

-
ESDU02A5V5R17V
Stackpole Electronics Inc
-
0603ESDA-MLP7
Eaton - Electronics Division
.jpg)
-
0603ESDA2-TR2
Eaton - Electronics Division

-
PS04LTVA1
Eaton - Electronics Division
.jpg)
-
0402ESDA-MLP1
Eaton - Electronics Division
.jpg)
-
0402ESDA-MLP7
Eaton - Electronics Division

-
TPD2S017DBVR
Texas Instruments
.jpg)
-
V2F105A150Y2EDP
KYOCERA AVX

-
82307050029
Würth Elektronik
-
NCP360SNT1G
onsemi
.jpg)
-
V2F118A400Y2EDP
KYOCERA AVX
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…

