Send an Inquiry

To receive a quote for your project, please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Part Number*
Quantity*
Message
Submit Inventory List

Please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Upload My List
Message

Texas Instruments ADS1244IDGSRG4

Part No.:
ADS1244IDGSRG4
Manufacturer:
Texas Instruments
Category:
Analog to Digital Converters (ADC)
Package:
10-TFSOP, 10-MSOP (0.118", 3.00mm Width)
Datasheet:
AetrixADS1244IDGSRG4.pdf
Description:
IC ADC 24BIT SIGMA-DELTA 10VSSOP
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:4,501

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

ADS1244IDGSRG4 from Texas Instruments is a 24-bit delta-sigma analog-to-digital converter in MSOP-10 package, featuring ±5V differential input range, 15 sps data rate, simultaneous 50Hz/60Hz rejection, single-cycle settling, and sleep mode consuming <1µW. It targets high-resolution portable instrumentation requiring low power and space-constrained PCB layouts.

For engineers reviewing the ADS1244IDGSRG4 datasheet, ADS1244IDGSRG4 pinout, ADS1244IDGSRG4 application, or ADS1244IDGSRG4 equivalent, key selection criteria include its 24-bit resolution with 0.0008% max INL, dual-supply flexibility (2.5–5.25V AVDD / 1.8–3.6V DVDD), 2-wire serial interface timing, and multichannel synchronization capability for industrial sensor systems.

Technical Context

The ADS1244IDGSRG4 implements a 3rd-order delta-sigma modulator followed by a digital filter that provides fixed 15 sps output with notch rejection at both 50Hz and 60Hz. Its analog front-end uses switched-capacitor sampling with effective input impedance of 13 MΩ (AINP/AINN) and 6.5 MΩ (differential path) at 2.4576 MHz CLK.

It supports self-calibration triggered via SCLK waveform, single-conversion operation using Sleep Mode entry/exit sequencing, and synchronous multichannel operation when multiple devices share CLK and SCLK. The DRDY/DOUT pin serves dual function: status indicator (active-low) and 24-bit MSB-first serial data output.

Key Specifications

ParameterValue and Actual Design Meaning
Resolution24-bit with no missing codes; delivers full 24-bit dynamic range without code gaps.
Data Rate15 samples per second (sps); fixed rate synchronized to 2.4576 MHz system clock.
Differential Input Range±5 V; supports wide-range sensor outputs such as load cells and RTD bridges without external gain.
INL (Max)0.0008% FSR; ensures ≤2 LSB error across full scale at 24-bit resolution.
Power (Normal)270 µW typical (AVDD = DVDD = 3 V); enables battery-powered handheld meters with multi-day runtime.
Sleep Mode Power<1 µW (AVDD current <1 µA); allows ultra-low-quiescent operation between sporadic measurements.
Supply RangesAVDD: 2.5–5.25 V; DVDD: 1.8–3.6 V; permits flexible dual- or single-supply system integration.
Common-Mode Rejection100 dB at 50/60 Hz; suppresses mains-induced noise in industrial wiring environments.

Pinout & Package

ADS1244IDGSRG4 is housed in a 10-pin MSOP package (3.0 mm × 3.0 mm × 1.0 mm height) with exposed thermal pad (DGS suffix). Pin mapping is validated per TI SBAS273 datasheet Figure "PIN CONFIGURATION" and "PIN DESCRIPTIONS".

Pin/TerminalCircuit RoleDesign Meaning
GND (Pin 1)Analog & Digital GroundSingle reference node for all analog/digital circuitry; requires low-impedance connection to PCB ground plane.
VREFP (Pin 2)Positive Reference InputHigh-impedance input for upper reference rail; must be bypassed with 0.1 µF capacitor to VREFN.
VREFN (Pin 3)Negative Reference InputHigh-impedance input for lower reference rail; forms differential reference VREF = VREFP – VREFN.
AINN (Pin 4)Negative Analog InputDifferential input terminal; accepts signals down to GND – 0.1 V (ESD-limited).
AINP (Pin 5)Positive Analog InputDifferential input terminal; accepts signals up to AVDD + 0.1 V (ESD-limited).
AVDD (Pin 6)Analog Power SupplySupplies modulator and reference circuitry; must be decoupled with 0.1 µF ceramic capacitor.
DVDD (Pin 7)Digital Power SupplySupplies digital filter and serial interface; independent voltage domain enables level-shifting.
DRDY/DOUT (Pin 8)Data Ready / Serial OutputOpen-drain status flag (LOW = valid data); transitions to push-pull output for 24-bit MSB-first data shift.
SCLK (Pin 9)Serial Clock InputEdge-triggered control line; rising edge clocks data out and initiates calibration/sleep commands.
CLK (Pin 10)System Clock InputDrives internal modulator and filter; 2.4576 MHz nominal frequency sets 15 sps and 50/60 Hz rejection notches.

Key Features

FeatureDesign Value
Simultaneous 50Hz & 60Hz rejectionDigital filter architecture inherently attenuates both power-line frequencies without external notch filters.
Single-cycle settlingOutput is fully settled after one conversion cycle (66.7 ms at 15 sps); eliminates need for averaging or discard cycles.
Self-calibrationOn-demand offset/gain correction via SCLK waveform; no external components required.
2-wire serial interfaceUses only SCLK and DRDY/DOUT pins; reduces MCU GPIO count and simplifies routing.
Multichannel synchronizationMultiple ADS1244IDGSRG4 units can share CLK/SCLK to achieve time-aligned sampling across channels.
Sleep Mode with wakeup calibrationHolding SCLK HIGH enters sub-µW sleep; taking SCLK LOW wakes device and optionally triggers post-wakeup calibration.

Applications

Hand-Held InstrumentationPortable Medical Equipment

Use Scenario: Battery-powered digital multimeter measuring resistance, voltage, and temperature with autoranging.

IC Role / Device Role / Timing Role: Primary ADC acquiring precision sensor data at 15 sps with integrated 50/60 Hz noise rejection.

Use Value: Eliminates external anti-aliasing filters and calibration hardware while maintaining 24-bit resolution in compact form factor.

Use Scenario: Portable blood glucose meter reading electrochemical test strip output under variable ambient lighting and EMI.

IC Role / Device Role / Timing Role: High-accuracy analog front-end digitizing low-level amperometric signals with minimal power draw.

Use Value: Achieves <1 µW idle power and 0.0008% INL to meet ISO 15197 accuracy requirements without active cooling.

Industrial Process ControlWeigh Scales

Use Scenario: Loop-powered 4–20 mA transmitter monitoring pressure or flow in hazardous-area field devices.

IC Role / Device Role / Timing Role: Isolated ADC capturing sensor output with galvanic separation and robust common-mode rejection.

Use Value: 100 dB CMRR at 50/60 Hz prevents mains interference from corrupting 4–20 mA loop diagnostics.

Use Scenario: Platform scale for retail or warehouse use measuring load cell output with temperature compensation.

IC Role / Device Role / Timing Role: Precision delta-sigma converter interfacing to Wheatstone bridge sensors with programmable gain.

Use Value: ±5 V differential input range directly accommodates unamplified load cell outputs, reducing BOM cost and board area.

Equivalent & Alternatives

The following parts are listed as comparable options for similar high-resolution, low-power delta-sigma ADC applications.

Alternative PartTechnical DifferenceApplication DifferenceSelection Advice
ADS1247IPW24-bit, 2kSPS, SPI interface, integrated PGA, 16-pin TSSOP; higher speed but larger footprint and no built-in 50/60 Hz rejection.Used in higher-channel-count industrial PLC modules where programmable gain and faster update rates are prioritized over ultra-low power.Select ADS1247IPW when system requires on-chip PGA and >15 sps throughput; ADS1244IDGSRG4 remains optimal for minimal power and fixed-frequency noise rejection.
AD7792BRUZ24-bit, 480 sps, SPI interface, 16-pin TSSOP, internal reference, 50/60 Hz rejection; lacks sleep mode & 2-wire simplicity.Favored in medical infusion pumps where internal reference and guaranteed 50/60 Hz rejection simplify design, despite higher quiescent current (400 µA).Choose AD7792BRUZ if internal reference and SPI compatibility outweigh sleep-mode power savings; ADS1244IDGSRG4 excels in longest-battery-life handheld tools.

Compared with ADS1247IPW and AD7792BRUZ, the ADS1244IDGSRG4 uniquely combines 2-wire simplicity, sub-µW sleep, and fixed 50/60 Hz rejection in a 10-pin MSOP - making it irreplaceable for space- and energy-constrained single-channel measurement nodes.

Availability

ADS1244IDGSRG4 is available at Aetrix Electronics and suitable for hand-held instrumentation, portable medical equipment, and industrial process control requiring stable component supply across long product lifecycles.

Supply support for ADS1244IDGSRG4 includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

Texas Instruments is a global semiconductor leader delivering analog, embedded processing, and connectivity solutions for industrial, automotive, and personal electronics markets.

The ADS1244IDGSRG4 belongs to TI's precision delta-sigma ADC product line, engineered specifically for ultra-low-power, high-resolution measurement in portable and battery-operated systems.

FAQ

What is the maximum clock frequency supported by ADS1244IDGSRG4?

The ADS1244IDGSRG4 supports a CLK input frequency up to 6 MHz per Absolute Maximum Ratings. However, the recommended operating frequency is 2.4576 MHz to ensure 15 sps data rate and precise 50/60 Hz rejection. At higher frequencies, the rejection notches shift proportionally (e.g., 4.9152 MHz moves notches to 100/120 Hz), and settling behavior remains single-cycle but timing parameters scale accordingly.

Does ADS1244IDGSRG4 require external calibration components?

No, the ADS1244IDGSRG4 performs full self-calibration internally without external components. Power-up calibration occurs automatically when AVDD and DVDD stabilize; user-initiated calibration is triggered via a defined SCLK waveform (26th falling edge after data read). Both offset and gain errors are corrected using on-chip capacitor arrays and digital trimming.

Can ADS1244IDGSRG4 operate from a single 3.3V supply?

Yes, the ADS1244IDGSRG4 supports single-supply operation: connect AVDD and DVDD together at 3.3 V. This satisfies both analog (2.5–5.25 V) and digital (1.8–3.6 V) supply ranges. Ensure proper 0.1 µF bypass capacitors on each supply pin and verify DRDY/DOUT logic levels match host MCU voltage thresholds.

How does the ADS1244IDGSRG4 achieve simultaneous 50Hz and 60Hz rejection?

The ADS1244IDGSRG4 achieves simultaneous 50Hz and 60Hz rejection through its fixed-coefficient digital filter architecture, which places deep notches exactly at both frequencies when driven by a 2.4576 MHz system clock. This is a deterministic property of the filter's transfer function-not software-configurable-and requires no external components or firmware intervention.

What is the meaning of "single-cycle settling" for ADS1244IDGSRG4?

"Single-cycle settling" means the ADS1244IDGSRG4 produces a fully settled, accurate 24-bit output after exactly one conversion interval (66.7 ms at 15 sps). There is no need to discard initial readings or perform multiple conversions before data is valid-enabling immediate use of every sample in time-critical or low-duty-cycle applications.

ADS1244IDGSRG4 Specifications

Product attributes
Attribute value
Manufacturer:
Texas Instruments
Series:
-
Package/Case:
10-TFSOP, 10-MSOP (0.118", 3.00mm Width)
Packaging:
Tape & Reel (TR)
Product Status:
Discontinued at Digi-Key
Number of Bits:
24
Sampling Rate (Per Second):
15
Number of Inputs:
1
Input Type:
Differential, Single Ended
Data Interface:
SPI
Configuration:
ADC
Ratio - S/H:ADC:
-
Number of A/D Converters:
1
Architecture:
Sigma-Delta
Reference Type:
External
Voltage - Supply, Analog:
2.5V ~ 5.25V
Voltage - Supply, Digital:
1.8V ~ 3.6V
Features:
-
Operating Temperature:
-40°C ~ 85°C
Supplier Device Package:
10-VSSOP
Mounting Type:
Surface Mount
Grade:
-
Qualification:
-

ADS1244IDGSRG4 FAQ

1.How can I place an order for ADS1244IDGSRG4 through Aetrix?

Please submit a Request for Quotation (RFQ) for ADS1244IDGSRG4 on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for ADS1244IDGSRG4 reliable?

The price and inventory of ADS1244IDGSRG4 are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for ADS1244IDGSRG4 is usually 5 days.

3.What payment methods are accepted for ADS1244IDGSRG4?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for ADS1244IDGSRG4 transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for ADS1244IDGSRG4?

ADS1244IDGSRG4 orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your ADS1244IDGSRG4 order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for ADS1244IDGSRG4?

For technical support, including ADS1244IDGSRG4 datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your ADS1244IDGSRG4 requirements.

6.How does Aetrix verify that ADS1244IDGSRG4 is sourced from the original manufacturer or authorized distributors?

All ADS1244IDGSRG4 products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that ADS1244IDGSRG4 meets industry standards.

7.What is the process for return or replacement of ADS1244IDGSRG4?

All ADS1244IDGSRG4 units undergo pre-shipment inspection (PSI). If there is an issue with ADS1244IDGSRG4, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The ADS1244IDGSRG4 part is unused and in its original packaging.

Return procedure for ADS1244IDGSRG4:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

ADS1244IDGSRG4 Tags

  • ADS1244IDGSRG4
  • ADS1244IDGSRG4 PDF
  • ADS1244IDGSRG4 Datasheet
  • ADS1244IDGSRG4 Specifications
  • ADS1244IDGSRG4 Images
  • Texas Instruments
  • Texas Instruments ADS1244IDGSRG4
  • Buy ADS1244IDGSRG4
  • ADS1244IDGSRG4 Price
  • ADS1244IDGSRG4 Distributor
  • ADS1244IDGSRG4 Supplier
  • ADS1244IDGSRG4 Wholesale
Related Products
ADC081C021CIMKX/NOPB
ADC081C021CIMKX/NOPB

Texas Instruments

MCP3021A5T-E/OT
MCP3021A5T-E/OT

Microchip Technology

TLA2024IRUGR
TLA2024IRUGR

Texas Instruments

MCP3221A5T-E/OT
MCP3221A5T-E/OT

Microchip Technology

MCP3221A5T-I/OT
MCP3221A5T-I/OT

Microchip Technology

MCP3221A4T-E/OT
MCP3221A4T-E/OT

Microchip Technology

MCP3221A6T-E/OT
MCP3221A6T-E/OT

Microchip Technology

MCP3221A0T-E/OT
MCP3221A0T-E/OT

Microchip Technology

MCP3221A1T-E/OT
MCP3221A1T-E/OT

Microchip Technology

ADC121S021CIMFX/NOPB
ADC121S021CIMFX/NOPB

Texas Instruments

MCP3001-I/MS
MCP3001-I/MS

Microchip Technology

MCP3001-I/SN
MCP3001-I/SN

Microchip Technology

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER