Analog Devices Inc. ADUM3200BRZ-RL7
- Part No.:
- ADUM3200BRZ-RL7
- Manufacturer:
- Analog Devices Inc.
- Category:
- Digital Isolators
- Package:
- 8-SOIC (0.154", 3.90mm Width)
- Datasheet:
-
ADUM3200BRZ-RL7.pdf
- Description:
- DGTL ISO 2500VRMS 2CH GP 8SOIC
- Quantity:
- Payment:

- Shipping:

Inventory:1,697
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
ADUM3200BRZ-RL7 from Analog Devices is a dual-channel, bidirectional digital isolator based on iCoupler® transformer technology, delivering 25 Mbps data rate, 3 ns pulse width distortion, and 25 kV/µs common-mode transient immunity. It operates at 3.3 V or 5 V on either side, enabling level translation across the isolation barrier, and is qualified for automotive applications up to 125°C in narrow-body SOIC-8 packaging.
For engineers reviewing the ADUM3200BRZ-RL7 datasheet, ADUM3200BRZ-RL7 pinout, ADUM3200BRZ-RL7 application, or ADUM3200BRZ-RL7 equivalent, key selection criteria include system-level ESD robustness per IEC 61000-4-x, precise channel-to-channel timing matching (≤3 ns), and mixed-supply operation (3.3 V/5 V) without external level shifters.
Technical Context
The ADUM3200BRZ-RL7 implements two independent unidirectional or bidirectional isolation channels using monolithic air-core transformers, eliminating LED-photodiode aging and CTR drift inherent in optocouplers. Its architecture supports dc-to-25 Mbps NRZ signaling with guaranteed timing performance across −40°C to +125°C.
It features enhanced system-level ESD reliability via layout and circuit modifications relative to earlier iCoupler generations, validated under IEC 61000-4-2/4-4/4-5. Insulation meets UL 1577 (2500 VRMS/1 min), DIN EN IEC 60747-17 (VIORM = 560 VPEAK), and IEC/EN/CSA 62368-1.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Data Rate | DC to 25 Mbps NRZ - supports high-speed SPI, RS-485, and digital field bus isolation without oversampling or encoding. |
| Pulse Width Distortion | ≤3 ns - ensures minimal duty-cycle degradation for clock forwarding and PWM signal isolation. |
| Channel Matching | ≤3 ns codirectional skew - enables synchronous dual-signal isolation critical for encoder interfaces and ADC timing. |
| Common-Mode Transient Immunity | >25 kV/µs - maintains signal integrity in noisy motor drive, battery monitor, and industrial power supply environments. |
| Supply Voltage Range | 3.0–3.6 V or 4.5–5.5 V per side - allows flexible interfacing between 3.3 V microcontrollers and 5 V peripherals or sensors. |
| Isolation Rating | 2500 VRMS for 1 minute (UL 1577); VIORM = 560 VPEAK (DIN EN IEC 60747-17) - certified for reinforced insulation in safety-critical systems. |
| Operating Temperature | −40°C to +125°C - qualified for automotive battery management, EV traction inverters, and under-hood control modules. |
Pinout & Package
Narrow-body, RoHS-compliant 8-lead SOIC package (SOIC_N), 5.3 mm × 6.2 mm footprint, 1.75 mm height, creepage/clearance ≥5.5 mm.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| Pin 1 | VDD1 Power Supply | Input-side supply (3.3 V or 5 V); powers Channel A input logic and transformer driver. |
| Pin 2 | GND1 Ground | Input-side reference; must be decoupled locally to minimize noise coupling into isolation barrier. |
| Pin 3 | INA Input A | Unidirectional input for Channel A; accepts CMOS levels referenced to VDD1. |
| Pin 4 | INB Input B | Unidirectional input for Channel B; electrically isolated from Pin 3; supports independent data streams. |
| Pin 5 | OUTA Output A | Output for Channel A; CMOS-compatible, referenced to VDD2; drives downstream logic on isolated side. |
| Pin 6 | OUTB Output B | Output for Channel B; fully isolated from OUTA; enables dual-signal transmission across barrier. |
| Pin 7 | GND2 Ground | Output-side reference; galvanically separated from GND1; requires separate ground plane partitioning. |
| Pin 8 | VDD2 Power Supply | Output-side supply (3.3 V or 5 V); powers Channel A/B output buffers and receiver logic. |
Key Features
| Feature | Design Value |
|---|---|
| Enhanced System-Level ESD Reliability | Validated per IEC 61000-4-2 (±8 kV contact), -4-4 (±2 kV burst), and -4-5 (±1 kV surge) - reduces board-level protection component count. |
| Bidirectional Communication Support | Configurable as two unidirectional or one bidirectional channel pair - simplifies SPI full-duplex and UART isolation without external logic. |
| 3.3 V / 5 V Level Translation | No external level shifters required when interfacing 3.3 V MCU with 5 V transceivers or sensors - lowers BOM cost and layout complexity. |
| Low Power at High Speed | 7.0 mA per channel max at 25 Mbps (5 V), 5.2 mA per channel max at 25 Mbps (3.3 V) - enables thermally constrained automotive and portable designs. |
| High-Temperature Operation | Rated for continuous 125°C junction temperature - suitable for engine control units, battery monitors, and industrial PLCs without derating. |
Applications
| SPI Interface Isolation | RS-485 Transceiver Isolation |
|---|---|
Use Scenario: Isolating SPI bus between MCU and isolated ADC or DAC in industrial data acquisition systems. IC Role / Device Role / Timing Role: Dual-channel isolator providing independent SCLK/MOSI and MISO paths with matched propagation delay. Use Value: Eliminates ground loop noise and prevents fault propagation while preserving <100 ns timing alignment between clock and data lines. |
Use Scenario: Galvanic isolation of RS-485 transceiver control lines (DE/RE) and data lines (A/B) in factory automation networks. IC Role / Device Role / Timing Role: Bidirectional isolator handling half-duplex control signals and differential data with simultaneous channel operation. Use Value: Enables safe communication across different ground domains in multi-node daisy-chain topologies with >25 kV/µs noise rejection. |
| Digital Field Bus Isolation | Battery Monitor Interface |
Use Scenario: Isolating CAN or PROFIBUS controller I/O in distributed control systems subject to high EMI. IC Role / Device Role / Timing Role: Dual-channel isolator separating controller-side logic from bus-side transceiver, supporting up to 25 Mbps. Use Value: Maintains signal integrity during fast edge transitions and prevents common-mode transients from disrupting bus arbitration. |
Use Scenario: Isolating voltage/current sensing signals and control commands between battery cell monitoring ICs and host MCU in EV battery packs. IC Role / Device Role / Timing Role: Reinforced-isolation dual channel for analog front-end digital outputs and safety-critical fault reporting lines. Use Value: Meets IEC 62368-1 and UL 1577 requirements while operating reliably at 125°C near high-voltage battery stacks. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar digital isolator applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| SI8620ED-B-IS | Capacitive isolation; 25 Mbps; 3.75 kVRMS rating; no automotive qualification; higher CMTI (50 kV/µs). | Preferred for non-automotive industrial systems requiring highest CMTI; lacks IEC 61000-4-x system-level ESD enhancements. | Select SI8620ED-B-IS when CMTI >35 kV/µs is mandatory and automotive qualification is unnecessary. |
| ISO7721DR | Capacitive isolation; 100 Mbps; 5000 VRMS; 125°C operation; lower quiescent current (1.5 mA/ch @ 0 Mbps); no system-level ESD certification. | Better suited for high-speed, low-power applications like server PMBus or PCIe auxiliary links; not tested to IEC 61000-4-x system-level ESD. | Choose ISO7721DR for bandwidth-critical designs where 100 Mbps is needed and system-level ESD robustness is managed at board level. |
Compared with SI8620ED-B-IS and ISO7721DR, the ADUM3200BRZ-RL7 uniquely combines automotive qualification, system-level IEC 61000-4-x ESD hardening, and precise 3 ns timing matching-making it optimal for safety-relevant battery monitoring and motor control where board-level ESD margin is constrained.
Availability
ADUM3200BRZ-RL7 is available at Aetrix Electronics and suitable for automotive battery management, industrial RS-485 networks, and SPI-isolated data acquisition systems requiring stable component supply and long-term lifecycle support.
Supply support for ADUM3200BRZ-RL7 includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Analog Devices, Inc. is a global leader in high-performance analog, mixed-signal, and digital signal processing semiconductors, serving industrial, automotive, communications, and healthcare markets.
The ADUM3200BRZ-RL7 belongs to the iCoupler® digital isolator product line, engineered specifically for robust galvanic isolation in electric vehicle subsystems, industrial automation, and safety-certified equipment where reliability under ESD stress and high-temperature operation are critical.
FAQ
What is the maximum data rate supported by the ADUM3200BRZ-RL7?
The ADUM3200BRZ-RL7 supports a maximum data rate of 25 Mbps in NRZ format across its dual isolation channels. This is verified over the full operating temperature range (−40°C to +125°C) and under both 3.3 V and 5 V supply conditions, with timing parameters including pulse width distortion ≤3 ns maintained at this rate.
Does the ADUM3200BRZ-RL7 support level translation between 3.3 V and 5 V domains?
Yes, the ADUM3200BRZ-RL7 supports true bidirectional level translation: VDD1 may be 3.3 V while VDD2 is 5 V (or vice versa), with logic thresholds scaling to 0.3× and 0.7× respective supply voltages. This eliminates external level shifters in mixed-voltage systems such as 3.3 V MCUs driving 5 V RS-485 transceivers.
Is the ADUM3200BRZ-RL7 qualified for automotive applications?
Yes, the ADUM3200BRZ-RL7 is explicitly qualified for automotive applications per AEC-Q100 and rated for continuous operation at 125°C ambient. It carries automotive-grade part numbers (e.g., ADUM3200W), meets IEC/EN/CSA 62368-1, and includes enhanced system-level ESD robustness per IEC 61000-4-x - all confirmed in the Rev. G datasheet.
What safety certifications does the ADUM3200BRZ-RL7 hold?
The ADUM3200BRZ-RL7 is certified to UL 1577 (2500 VRMS/1 min), DIN EN IEC 60747-17 (VDE 0884-17) with VIORM = 560 VPEAK, IEC/EN/CSA 62368-1, IEC/CSA 61010-1, and CQC GB4943.1. These approvals validate its suitability for reinforced insulation in safety-critical end equipment.
How does the ADUM3200BRZ-RL7 differ from standard optocouplers in terms of power consumption?
The ADUM3200BRZ-RL7 consumes significantly less power than comparable optocouplers: at 25 Mbps, it draws ≤7.0 mA per channel at 5 V (vs. typical optocoupler currents >10 mA at much lower speeds). Its iCoupler® transformer architecture eliminates LED bias current and driver losses, achieving ~1/6 the power of optocouplers at equivalent data rates.
ADUM3200BRZ-RL7 Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Analog Devices Inc.
- Series:
- iCoupler®
- Package/Case:
- 8-SOIC (0.154", 3.90mm Width)
- Packaging:
- Tape & Reel (TR)
- Product Status:
- Active
- Technology:
- Magnetic Coupling
- Type:
- General Purpose
- Isolated Power:
- No
- Number of Channels:
- 2
- Inputs - Side 1/Side 2:
- 2/0
- Channel Type:
- Unidirectional
- Voltage - Isolation:
- 2500Vrms
- Common Mode Transient Immunity (Min):
- 25kV/µs
- Data Rate:
- 10Mbps
- Propagation Delay tpLH / tpHL (Max):
- 50ns, 50ns
- Pulse Width Distortion (Max):
- 3ns
- Rise / Fall Time (Typ):
- 2.5ns, 2.5ns
- Voltage - Supply:
- 3V ~ 5.5V
- Grade:
- -
- Qualification:
- -
- Operating Temperature:
- -40°C ~ 105°C
- Mounting Type:
- Surface Mount
- Supplier Device Package:
- 8-SOIC
ADUM3200BRZ-RL7 FAQ
1.How can I place an order for ADUM3200BRZ-RL7 through Aetrix?
Please submit a Request for Quotation (RFQ) for ADUM3200BRZ-RL7 on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for ADUM3200BRZ-RL7 reliable?
The price and inventory of ADUM3200BRZ-RL7 are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for ADUM3200BRZ-RL7 is usually 5 days.
3.What payment methods are accepted for ADUM3200BRZ-RL7?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for ADUM3200BRZ-RL7 transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for ADUM3200BRZ-RL7?
ADUM3200BRZ-RL7 orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your ADUM3200BRZ-RL7 order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for ADUM3200BRZ-RL7?
For technical support, including ADUM3200BRZ-RL7 datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your ADUM3200BRZ-RL7 requirements.
6.How does Aetrix verify that ADUM3200BRZ-RL7 is sourced from the original manufacturer or authorized distributors?
All ADUM3200BRZ-RL7 products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that ADUM3200BRZ-RL7 meets industry standards.
7.What is the process for return or replacement of ADUM3200BRZ-RL7?
All ADUM3200BRZ-RL7 units undergo pre-shipment inspection (PSI). If there is an issue with ADUM3200BRZ-RL7, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The ADUM3200BRZ-RL7 part is unused and in its original packaging.
Return procedure for ADUM3200BRZ-RL7:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
ADUM3200BRZ-RL7 Tags
-
ISO1212DBQR
Texas Instruments

-
ISO6721BDR
Texas Instruments

-
SI8710AC-B-ISR
Skyworks Solutions Inc.

-
ISO7720FDR
Texas Instruments

-
ISO7721DR
Texas Instruments

-
ISO7721FDR
Texas Instruments

-
SI8710CC-B-ISR
Skyworks Solutions Inc.

-
ISO6741FQDWRQ1
Texas Instruments

-
ISO7721DWVR
Texas Instruments
-
ISO7762FDBQR
Texas Instruments

-
ISO7741DWR
Texas Instruments

-
ISO7741FDWR
Texas Instruments
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…