Broadcom Limited AFBR-7CER03Z
- Part No.:
- AFBR-7CER03Z
- Manufacturer:
- Broadcom Limited
- Category:
- Fiber Optic Transceiver Modules
- Package:
- Datasheet:
-
AFBR-7CER03Z.pdf
- Description:
- 10G SFP+ AOC
- Quantity:
- Payment:

- Shipping:

Inventory:2,367
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
AFBR-7CER03Z from Broadcom (formerly Avago Technologies) is a 3-meter SFP+ Active Optical Cable (AOC) designed for 10GbE interconnects in high-port-density systems. It delivers 10.3125 Gbps data rate per lane, 1E-15 BER performance, and operates across 0–70°C with 850 nm VCSEL/PIN optics and 275 mW nominal power per end.
For engineers reviewing the AFBR-7CER03Z datasheet, pinout, applications, or equivalent options, key selection criteria include SFP+ mechanical compliance (SFF-8432 IPF), two-wire serial management interface (Page A0h), Rx_LOS/Tx_DISABLE support, Class 1 laser safety, and compatibility with 10GbE, 8GFC, FCoE, and InfiniBand QDR/DDR protocols.
Technical Context
The AFBR-7CER03Z implements a fully integrated, non-retimed optical link using Avago's proven 850 nm VCSEL transmitter and PIN photodiode receiver. It complies with SFF-8431 electrical and SFF-8432 mechanical specifications, supporting direct connection to SFP+ host ports without external CDR or retiming circuitry.
No embedded retimer or CDR enables low-latency, transparent signal transmission at data rates from 1 to 10.3125 Gbps. Its 20-pin SFP+ edge connector interfaces via I²C-compatible two-wire serial bus (SFF-8472 Page A0h) for digital diagnostics monitoring (DDM) and control functions including Tx_DISABLE and Rx_LOS assertion.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Data Rate | 10.3125 Gbps per lane - supports full 10GBASE-SR line rate without retiming |
| Operating Temp | 0–70°C case temperature - validated for enterprise switch/router front-panel environments |
| Power Consumption | 275 mW per end - enables thermal management in dense 1U chassis with >48 ports |
| Optical Wavelength | 850 nm - optimized for OM3/OM4 multimode fiber with 300 m reach capability |
| Bit Error Rate | 1E-15 - meets IEEE 802.3ae requirements for 10GbE link integrity |
| Laser Safety | Class 1 per EN 60825-1:2007 & EN 60825-2:A2:2010 - no user-accessible hazardous radiation |
| Management Interface | Two-wire serial (I²C) - enables DDM readout and Tx_DISABLE control via SFF-8472 Page A0h |
Pinout & Package
AFBR-7CER03Z uses the standard SFP+ 20-pin edge connector defined in SFF-8431 and SFF-8432, housed in a pluggable Improved Pluggable Formfactor (IPF) housing compatible with INF-8074 and SFF-8431/2 compliant ports. Dimensions: 98.5 mm × 13.8 mm × 11.95 mm (L×W×H).
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1–10, 11–20 | Differential TX/RX lanes + ground pairs | 20-pin SFP+ edge interface - supports AC-coupled 100Ω differential signaling per lane |
| Mod_Def0 | Module definition | Grounded to indicate SFP+ AOC presence and protocol compliance |
| LOS | Receiver loss-of-signal indicator | Open-collector output asserted low when optical input drops below sensitivity threshold |
| TX_DISABLE | Transmitter disable control | Active-high TTL input - disables VCSEL output for hot-plug safety and power management |
| SDA/SCL | I²C data/clock | Two-wire serial interface to EEPROM (Page A0h) for DDM and vendor ID access |
Key Features
| Feature | Design Value |
|---|---|
| Optical Link Architecture | Direct-attach, non-retimed 850 nm VCSEL-to-PIN link - eliminates jitter accumulation and latency variation |
| EMI Performance | SFP+ package design with margin to FCC/CE Class B limits - enables reliable operation in 48-port 1U switches |
| Protocol Agnosticism | Supports 1/10GbE, 1/2/4/8/10GFC, SDR/DDR/QDR InfiniBand - no firmware or configuration required |
| Hot-Plug Compliance | Full SFF-8431 electrical sequencing - allows live insertion/removal without host reset or link flap |
| RoHS & Safety | Compliant with EU/China RoHS and EN 60825-1/2 Class 1 laser safety - certified for data center deployment |
Applications
| 10GbE Data Center Top-of-Rack Switching | Converged Fibre Channel over Ethernet (FCoE) |
|---|---|
Use Scenario: Interconnecting TOR switches to server NICs within a single rack or adjacent racks up to 3 meters. IC Role / Device Role / Timing Role: Passive optical interconnect replacing copper DACs - provides deterministic latency and immunity to EMI-induced bit errors. Use Value: Enables 48+ port 10GbE TOR switches with <275 mW/port power budget and zero crosstalk between adjacent links. | Use Scenario: Connecting FCoE-capable storage adapters to FCoE switches in unified fabric deployments. IC Role / Device Role / Timing Role: Protocol-transparent optical bridge - preserves FC frame timing and avoids serialization delay introduced by retimers. Use Value: Maintains sub-1 µs round-trip latency required for SCSI command/response integrity in storage networks. |
| InfiniBand QDR Compute Clusters | High-Density Networked Storage Backplanes |
Use Scenario: Node-to-node interconnect in HPC clusters using QDR InfiniBand at 40 Gbps aggregate (4×10.3125 Gbps lanes). IC Role / Device Role / Timing Role: Lane-level optical physical layer - delivers 1E-15 BER at full QDR line rate without forward error correction overhead. Use Value: Eliminates need for active copper cables with higher insertion loss and thermal derating above 2 meters. | Use Scenario: Rack-scale JBOD or storage controller-to-expander interconnects in NVMe-oF or SAS-3 hybrid arrays. IC Role / Device Role / Timing Role: High-reliability optical link - avoids corrosion, contact wear, and impedance mismatch issues of repeated mating cycles in backplane applications. Use Value: Supports >10,000 insertions with stable 10.3125 Gbps eye diagram and no link training failures. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar high-speed optical interconnect applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| AFBR-7CER05Z | 5-meter cable length; identical optics, power, and interface specs | Supports longer reach between adjacent racks; same thermal and EMI profile | Select when interconnect distance exceeds 3 m but remains ≤5 m and SFP+ port density is unchanged |
| AFBR-703SDZ | Pluggable SFP+ transceiver (not AOC); requires separate MMF patch cables; 300 m OM3 reach | Enables flexible, reconfigurable fiber routing; higher system-level latency due to duplex fiber path | Select when topology requires field-replaceable optics or distances >3 m up to 300 m |
Compared with AFBR-7CER03Z, AFBR-7CER05Z offers extended reach with identical electrical/optical behavior, while AFBR-703SDZ trades fixed-length simplicity for field flexibility and longer reach at the cost of added fiber management and latency.
Availability
AFBR-7CER03Z is available at Aetrix Electronics and suitable for 10GbE data center switching, FCoE storage networking, and InfiniBand QDR compute clustering requiring stable component supply and guaranteed long-term availability.
Supply support for AFBR-7CER03Z includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Broadcom Inc. (formerly Avago Technologies) is a global semiconductor leader specializing in infrastructure software, networking, and optical connectivity solutions.
The AFBR-7CER03Z belongs to Broadcom's SFP+ Active Optical Cable family, engineered specifically for ultra-dense, low-power, high-reliability 10GbE interconnects in cloud-scale data centers and HPC environments.
FAQ
What is the maximum supported data rate for AFBR-7CER03Z?
The AFBR-7CER03Z supports a maximum data rate of 10.3125 Gbps per lane, fully compliant with 10GBASE-SR and SFF-8431 specifications. It operates without embedded retimers or CDRs, enabling transparent transmission from 1 Gbps up to 10.3125 Gbps. This makes AFBR-7CER03Z suitable for multi-protocol use in 10GbE, 8GFC, and InfiniBand QDR applications without firmware updates or configuration changes.
Does AFBR-7CER03Z require external power or host-side configuration?
No, AFBR-7CER03Z draws all operating power from the host SFP+ port's 3.3 V supply and requires no external power source or host-side firmware configuration. It implements SFF-8472-compliant two-wire serial interface (Page A0h) for basic DDM readout and Tx_DISABLE control, but operates plug-and-play with default settings. AFBR-7CER03Z is fully interoperable with any SFF-8431-compliant host without driver or BIOS modifications.
Is AFBR-7CER03Z compatible with standard SFP+ cages and PCB footprints?
Yes, AFBR-7CER03Z conforms to the SFF-8432 Improved Pluggable Formfactor (IPF) mechanical specification and fits all INF-8074 and SFF-8431/2-compliant SFP+ cages and PCB footprints. Its dimensions (98.5 × 13.8 × 11.95 mm) and 20-pin edge connector match industry-standard SFP+ modules, enabling drop-in replacement of passive copper DACs without board layout changes.
What safety certifications does AFBR-7CER03Z hold?
AFBR-7CER03Z is certified Class 1 Laser Product per EN 60825-1:2007 and EN 60825-2:A2:2010, ensuring no hazardous optical radiation is accessible during normal operation or single-fault conditions. It also complies with RoHS directives in both EU and China jurisdictions, confirming absence of lead, mercury, cadmium, and other restricted substances in its construction and assembly.
How does AFBR-7CER03Z compare to passive copper DACs in thermal performance?
AFBR-7CER03Z dissipates only 275 mW per end versus typical 600–900 mW for 3-meter passive copper DACs, significantly reducing localized heat buildup in high-port-density systems. Its optical architecture eliminates resistive losses and skin-effect degradation, allowing consistent signal integrity across temperature and enabling tighter thermal margins in 1U switches. This makes AFBR-7CER03Z more thermally efficient than copper alternatives at the same reach.
AFBR-7CER03Z Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Broadcom Limited
- Series:
- -
- Packaging:
- Tray
- Product Status:
- Obsolete
- Data Rate:
- 10Gbs
- Wavelength:
- 850nm
- Applications:
- Ethernet
- Voltage - Supply:
- 3.3V
- Connector Type:
- -
- Mounting Type:
- Pluggable, SFP+
AFBR-7CER03Z FAQ
1.How can I place an order for AFBR-7CER03Z through Aetrix?
Please submit a Request for Quotation (RFQ) for AFBR-7CER03Z on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for AFBR-7CER03Z reliable?
The price and inventory of AFBR-7CER03Z are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for AFBR-7CER03Z is usually 5 days.
3.What payment methods are accepted for AFBR-7CER03Z?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for AFBR-7CER03Z transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for AFBR-7CER03Z?
AFBR-7CER03Z orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your AFBR-7CER03Z order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for AFBR-7CER03Z?
For technical support, including AFBR-7CER03Z datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your AFBR-7CER03Z requirements.
6.How does Aetrix verify that AFBR-7CER03Z is sourced from the original manufacturer or authorized distributors?
All AFBR-7CER03Z products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that AFBR-7CER03Z meets industry standards.
7.What is the process for return or replacement of AFBR-7CER03Z?
All AFBR-7CER03Z units undergo pre-shipment inspection (PSI). If there is an issue with AFBR-7CER03Z, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The AFBR-7CER03Z part is unused and in its original packaging.
Return procedure for AFBR-7CER03Z:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
AFBR-7CER03Z Tags

-
AFBR-5972EZ
Broadcom Limited

-
AFBR-5972BZ
Broadcom Limited
-
FTLF8519P3BNL
Coherent
-
AFBR-5803Z
Broadcom Limited
-
AFBR-5803TZ
Broadcom Limited
-
FTLF8519P3BTL
Coherent
-
AFBR-5803ATZ
Broadcom Limited
-
AFBR-5803ATQZ
Broadcom Limited

-
FTLX8574D3BCV
Coherent

-
FTLF8526P3BNL
Coherent

-
FTLF8519F2GCL
Coherent
-
FTLF1318P3BTL
Coherent
Tech Hub
Counterfeit components can hide behind convincing markings and passing basic function tests. This engineering reference covers source traceability, external inspection, X-ray, XRF, electrical testing, …
A practical engineering and sourcing framework covering lifecycle verification, lifetime-buy calculations, replacement qualification, supplier checks and counterfeit-risk controls.
TTL and CMOS logic families differ in thresholds, loading, output drive, power and timing. This engineering guide compares 74HC and 74HCT, calculates noise margins and checks 3.3 V/5 V compatibility.
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
