Schneider Electric BDL36125
- Part No.:
- BDL36125
- Manufacturer:
- Schneider Electric
- Category:
- Circuit Breakers
- Package:
- Description:
- MOLDED CASE CIRCUIT BRKR 600Y/34
- Quantity:
- Payment:

- Shipping:

Inventory:3,621
Please send an inquiry. Send us your inquiry, and we will respond immediately.
BDL36125 Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Schneider Electric
- Series:
- PowerPact
- Packaging:
- Box
- Product Status:
- Active
- Mounting Type:
- DIN Rail
- Breaker Type:
- Thermal Magnetic
- Current Rating (Amps):
- 125A
- Voltage Rating - AC:
- 600 V
- Voltage Rating - DC:
- -
- Actuator Type:
- Toggle
- Number of Poles:
- 3
- Illumination:
- None
- Illumination Voltage (Nominal):
- -
- Approval Agency:
- CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489
BDL36125 FAQ
1.How can I place an order for BDL36125 through Aetrix?
Please submit a Request for Quotation (RFQ) for BDL36125 on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for BDL36125 reliable?
The price and inventory of BDL36125 are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for BDL36125 is usually 5 days.
3.What payment methods are accepted for BDL36125?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for BDL36125 transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for BDL36125?
BDL36125 orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your BDL36125 order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for BDL36125?
For technical support, including BDL36125 datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your BDL36125 requirements.
6.How does Aetrix verify that BDL36125 is sourced from the original manufacturer or authorized distributors?
All BDL36125 products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that BDL36125 meets industry standards.
7.What is the process for return or replacement of BDL36125?
All BDL36125 units undergo pre-shipment inspection (PSI). If there is an issue with BDL36125, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The BDL36125 part is unused and in its original packaging.
Return procedure for BDL36125:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
BDL36125 Tags

-
QMB-153-11C3N-3BA
Qualtek
-
4404.0002
SCHURTER Inc.
-
4404.0105
SCHURTER Inc.
-
W57-XB7A4A10-5
TE Connectivity Potter & Brumfield Relays

-
W28-XQ1A-3
TE Connectivity Potter & Brumfield Relays

-
W54-XB1A4A10-20
TE Connectivity Potter & Brumfield Relays
-
W57-XB7A4A10-20
TE Connectivity Potter & Brumfield Relays

-
W54-XB1A4A10-30
TE Connectivity Potter & Brumfield Relays

-
W51-A121B1-15
TE Connectivity Potter & Brumfield Relays
-
W57-XB1A7A10-5
TE Connectivity Potter & Brumfield Relays

-
W28-XQ1A-8
TE Connectivity Potter & Brumfield Relays

-
W28-XQ1A-4
TE Connectivity Potter & Brumfield Relays
Tech Hub
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…
LDO regulator guide covering low dropout voltage, power dissipation, thermal design, PSRR, output noise, capacitor stability, adjustable LDO circuits, LDO vs buck converter and datasheet selection chec…
Conditional Access Module guide covering CAM meaning, CI/CI+ interface, smart card authorization, DVB security workflow, TV and set-top box compatibility, internal electronics, ESD protection, connecto…
Guide to electronic component obsolescence covering EOL risk, PCN/PDN notices, last-time buy planning, replacement options, form-fit-function validation, counterfeit risk and BOM lifecycle management.
18650 battery guide covering lithium-ion cell basics, 3.6V/3.7V voltage, 4.2V charging, mAh and Wh capacity, protected cells, chargers, BMS, series-parallel packs, holders, welding and sourcing checks.…
Hall effect sensor guide covering working principle, linear and digital sensors, Arduino circuits, current sensing, speed detection, automotive applications, A3144 examples, signal filtering and datash…
Product Change Notification guide for electronic components, covering PCN meaning, PCN vs PDN/EOL, common change types, risk levels, form-fit-function review, engineering validation, BOM control, LTB/L…
A practical guide to blend door actuators, covering HVAC function, symptoms, location, AC and heater issues, reset and calibration, replacement cost, electrical diagnosis, compatibility checks, and rep…
Engineering guide to Raspberry Pi alternatives, covering chip-level differences, Orange Pi, ROCK, Jetson, Banana Pi, NanoPi, Compute Module, Pico, GPIO, camera, HAT compatibility, and replacement risks…
Engineering guide to dynamic load response testing for high-current buck converters, covering load step setup, slew rate, Vcore undershoot, overshoot, recovery time, probe location, output capacitors a…