Analog Devices Inc./Maxim Integrated DS1811-10+
- Part No.:
- DS1811-10+
- Manufacturer:
- Analog Devices Inc./Maxim Integrated
- Category:
- Supervisors
- Package:
- TO-226-3, TO-92-3 (TO-226AA)
- Datasheet:
-
DS1811-10+.pdf
- Description:
- IC SUPERVISOR 1 CHANNEL TO92-3
- Quantity:
- Payment:

- Shipping:

Inventory:281
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
DS1811-10+ from Maxim Integrated (now Analog Devices) is a 5V precision voltage-monitoring supervisor IC with open-drain active-low reset output, 4.35 V typical VCC trip point, 150 ms reset timeout, and -40°C to +85°C operating range. It automatically asserts reset during power failure and holds reset for ≥100 ms after VCC recovery, enabling reliable microprocessor startup in embedded power management systems.
For engineers reviewing the DS1811-10+ datasheet, DS1811-10+ pinout, DS1811-10+ application, or DS1811-10+ equivalent, key selection criteria include trip voltage tolerance (±10%), internal 5.5 kΩ pull-up resistor, open-drain RST output drive capability, guaranteed reset timing across temperature, and TO-92/SOT-23 package compatibility with legacy board layouts.
Technical Context
The DS1811-10+ integrates a precision temperature-compensated voltage reference and comparator to detect VCC deviations against its factory-trimmed 4.25–4.49 V trip window. Its internal power-fail detection circuit triggers immediate RST assertion on undervoltage, independent of external components.
Upon VCC return, an on-chip timer enforces a fixed 100–300 ms reset hold time (150 ms typical), ensuring stable power and processor initialization before release. The open-drain output supports wired-OR configurations and interfaces directly with TTL/CMOS inputs without external pull-ups in many cases.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| VCC Trip Point | 4.25 V (min) to 4.49 V (max); ensures reset activation before 5V rail drops below microprocessor minimum supply requirement |
| Reset Timeout | 100–300 ms (typ 150 ms); guarantees sufficient stabilization time for CPU clock and memory after power recovery |
| Output Type | Open-drain RST with internal 3.5–7.5 kΩ pull-up; eliminates need for external resistor in standard 5V logic interface |
| Supply Range | 1.2 V to 5.5 V; supports operation down to brown-out threshold while maintaining valid trip detection |
| Operating Temp | -40°C to +85°C; qualified for industrial-grade embedded control and automotive body electronics |
| IOL (RST) | 10 mA @ 0.4 V; drives standard CMOS/TTL reset inputs without buffer stage |
| ICC | 30–40 µA; ultra-low quiescent current preserves battery life in always-on monitoring applications |
Pinout & Package
DS1811-10+ is available in both TO-92 and SOT-23 packages - identical pin mapping, fully interchangeable at board level. Both packages support through-hole and surface-mount assembly.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| RST (Pin 1) | Active-low open-drain reset output | Asserts low during VCC fault or power-up; requires external pull-up only if interfacing with >5.5V logic or high-capacitance buses |
| VCC (Pin 2) | Power supply input | Monitored rail input; powers internal reference and comparator; operates from 1.2 V to 5.5 V |
| GND (Pin 3) | Ground reference | Return path for internal circuitry and reset output sink current; must be connected to system ground plane |
Key Features
| Feature | Design Value |
|---|---|
| Factory-trimmed ±10% trip accuracy | Eliminates manual calibration and external resistor networks for precise 5V system supervision |
| Internal 5.5 kΩ pull-up resistor | Reduces BOM count by one component and PCB footprint in standard 5V microcontroller reset circuits |
| 150 ms guaranteed reset timeout | Meets JEDEC JESD78 latch-up immunity timing requirements for most 8-/16-bit microcontrollers |
| Temperature-compensated reference | Maintains trip point stability over full -40°C to +85°C range without drift-induced false resets |
| Low 40 µA supply current | Enables use in battery-backed systems where continuous monitoring must not degrade standby life |
Applications
| Industrial PLC Controller | Smart Meter Power Management |
|---|---|
Use Scenario: Uninterrupted operation during grid voltage sags or capacitor discharge events in DIN-rail mounted controllers. IC Role / Device Role / Timing Role: Primary power-fail detector and reset sequencer for ARM Cortex-M4-based main controller. Use Value: Prevents firmware corruption by holding reset until DC bus stabilizes post-sag, leveraging 150 ms timeout and 4.35 V trip point matched to 5V LDO output. | Use Scenario: Maintaining secure state during utility power interruption in ANSI C12.22-compliant electricity meters. IC Role / Device Role / Timing Role: Supervisory watchdog that initiates nonvolatile memory write-protection and RTC backup switchover. Use Value: Internal 5.5 kΩ pull-up enables direct connection to meter SoC reset pin, reducing layout complexity and eliminating solder joint failure points. |
| POS Terminal Boot Integrity | Automotive Body Control Module |
Use Scenario: Ensuring deterministic boot sequence after vehicle battery reconnection or alternator load dump transients. IC Role / Device Role / Timing Role: Voltage monitor triggering hard reset of payment processing MCU when 5V rail falls below 4.25 V. Use Value: ±10% trip tolerance accommodates production variance in 5V switching regulator output while guaranteeing reset before brownout lockup. | Use Scenario: Reliable microcontroller restart after cold-cranking voltage dip (<6 V) in 12V automotive subsystems. IC Role / Device Role / Timing Role: System-level reset generator synchronized to battery voltage recovery profile. Use Value: -40°C to +85°C rating and temperature-compensated reference ensure consistent trip behavior across engine bay thermal cycles. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar voltage-monitoring supervisor applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| TPS3808G15DBVR | Fixed 1.5V trip, adjustable delay; no internal pull-up; higher quiescent current (1.1 µA) | Designed for low-voltage ASICs, not 5V microcontrollers | Select only if supervising sub-2V rails or requiring programmable timeout |
| MAX6326UR29D3+ | 2.93V trip, 200 ms timeout, push-pull output, no internal pull-up | Requires external pull-up for open-drain compatibility; tighter trip tolerance (±1.5%) | Prefer when absolute trip accuracy > ±2% is required and board space allows extra resistor |
Compared with TPS3808G15DBVR and MAX6326UR29D3+, the DS1811-10+ delivers optimized 5V system supervision with integrated pull-up, lower ICC, and factory-trimmed ±10% trip-reducing design iterations and test validation effort for cost-sensitive industrial controls.
Availability
DS1811-10+ is available at Aetrix Electronics and suitable for industrial PLC controllers, smart meter power management, and POS terminal boot integrity applications requiring stable component supply and long-term lifecycle support.
Supply support for DS1811-10+ includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Analog Devices (via acquisition of Maxim Integrated) designs precision analog, mixed-signal, and power management ICs for industrial, automotive, and communications infrastructure.
The DS1811-10+ belongs to Maxim's EconoReset™ supervisor family, engineered for cost-effective, single-supply voltage monitoring in resource-constrained embedded systems where reliability and minimal external components are critical.
FAQ
What is the exact VCC trip voltage range for DS1811-10+?
The DS1811-10+ has a guaranteed VCC trip point range of 4.25 V (minimum) to 4.49 V (maximum), with 4.35 V typical. This ±10% tolerance is factory-trimmed and temperature-compensated, ensuring consistent detection of 5V rail undervoltage across the full -40°C to +85°C operating range. DS1811-10+ does not require external resistors to set this threshold.
Does DS1811-10+ require an external pull-up resistor on the RST pin?
No, DS1811-10+ includes an internal 3.5–7.5 kΩ pull-up resistor on the open-drain RST output, eliminating the need for an external component in standard 5V logic interfaces. An external pull-up is only necessary when driving voltages above 5.5 V or interfacing with high-capacitance buses exceeding 10 pF load.
How long is the reset pulse duration of DS1811-10+ after VCC recovery?
The DS1811-10+ holds the RST pin active low for 100–300 ms after VCC returns to within tolerance, with 150 ms typical. This fixed timeout is generated by an internal timer and ensures microprocessor and power supply stabilization before release. DS1811-10+ does not support adjustable delay or external capacitor programming.
Can DS1811-10+ operate from a 3.3V supply?
Yes, DS1811-10+ operates from 1.2 V to 5.5 V, but its 4.25–4.49 V trip point is designed specifically for 5V systems. When powered from 3.3V, the device remains functional for monitoring higher rails via external resistor divider, but the internal trip threshold remains fixed. DS1811-10+ is not intended as a 3.3V rail supervisor.
What package options are available for DS1811-10+?
DS1811-10+ is offered in both TO-92 (through-hole) and SOT-23 (surface-mount) packages, with identical pinout (RST-VCC-GND) and electrical specifications. Both packages share the same -40°C to +85°C temperature rating and are interchangeable in design, supporting legacy board upgrades and new compact layouts.
DS1811-10+ Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Analog Devices Inc./Maxim Integrated
- Series:
- EconoReset
- Package/Case:
- TO-226-3, TO-92-3 (TO-226AA)
- Packaging:
- Bulk
- Product Status:
- Active
- Programmable:
- Not Verified
- Type:
- Simple Reset/Power-On Reset
- Number of Voltages Monitored:
- 1
- Voltage - Threshold:
- 4.35V
- Output:
- Open Drain or Open Collector
- Reset:
- Active Low
- Reset Timeout:
- 100ms Minimum
- Operating Temperature:
- -40°C ~ 85°C (TA)
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Through Hole
- Supplier Device Package:
- TO-92-3
DS1811-10+ FAQ
1.How can I place an order for DS1811-10+ through Aetrix?
Please submit a Request for Quotation (RFQ) for DS1811-10+ on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for DS1811-10+ reliable?
The price and inventory of DS1811-10+ are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for DS1811-10+ is usually 5 days.
3.What payment methods are accepted for DS1811-10+?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for DS1811-10+ transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for DS1811-10+?
DS1811-10+ orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your DS1811-10+ order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for DS1811-10+?
For technical support, including DS1811-10+ datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your DS1811-10+ requirements.
6.How does Aetrix verify that DS1811-10+ is sourced from the original manufacturer or authorized distributors?
All DS1811-10+ products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that DS1811-10+ meets industry standards.
7.What is the process for return or replacement of DS1811-10+?
All DS1811-10+ units undergo pre-shipment inspection (PSI). If there is an issue with DS1811-10+, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The DS1811-10+ part is unused and in its original packaging.
Return procedure for DS1811-10+:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
DS1811-10+ Tags

-
MIC826SYMT-TR
Microchip Technology

-
APX803S-31SA-7
Diodes Incorporated

-
APX803L20-29SA-7
Diodes Incorporated
-
TPS3828-33DBVR
Texas Instruments

-
V6340RSP3B+
EM Microelectronic

-
EM6325CXSP5B-2.9+
EM Microelectronic

-
MCP120T-300I/TT
Microchip Technology

-
MCP130T-315I/TT
Microchip Technology

-
MCP120T-475I/TT
Microchip Technology

-
MCP111T-300E/TT
Microchip Technology

-
MCP120T-315I/TT
Microchip Technology

-
MCP809T-315I/TT
Microchip Technology
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…