DFRobot FIT0826
- Part No.:
- FIT0826
- Manufacturer:
- DFRobot
- Category:
- Thermoelectric, Peltier Modules
- Package:
- Description:
- ELECTRIC COOLER MODULE (5V 1A)
- Quantity:
- Payment:

- Shipping:

Inventory:1,848
Please send an inquiry. Send us your inquiry, and we will respond immediately.
FIT0826 Specifications
- Product attributes
- Attribute value
- Manufacturer:
- DFRobot
- Series:
- -
- Packaging:
- Bulk
- Product Status:
- Active
- Size / Dimension:
- Square - 30.00mm L x 30.00mm W
- Qmax @ Th:
- -
- Delta Tmax @ Th:
- -
- Height:
- 5.00mm
- Number of Stages:
- 1
- Current - Max:
- 2 A
- Voltage - Max:
- 8.4 V
- Resistance:
- -
- Operating Temperature:
- 83°C
- Features:
- Lead Wires
FIT0826 FAQ
1.How can I place an order for FIT0826 through Aetrix?
Please submit a Request for Quotation (RFQ) for FIT0826 on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for FIT0826 reliable?
The price and inventory of FIT0826 are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for FIT0826 is usually 5 days.
3.What payment methods are accepted for FIT0826?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for FIT0826 transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for FIT0826?
FIT0826 orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your FIT0826 order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for FIT0826?
For technical support, including FIT0826 datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your FIT0826 requirements.
6.How does Aetrix verify that FIT0826 is sourced from the original manufacturer or authorized distributors?
All FIT0826 products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that FIT0826 meets industry standards.
7.What is the process for return or replacement of FIT0826?
All FIT0826 units undergo pre-shipment inspection (PSI). If there is an issue with FIT0826, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The FIT0826 part is unused and in its original packaging.
Return procedure for FIT0826:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
FIT0826 Tags
-
CP40236
Same Sky (Formerly CUI Devices)
-
CP60233
Same Sky (Formerly CUI Devices)
-
CP30238
Same Sky (Formerly CUI Devices)

-
CP39301536H
Same Sky (Formerly CUI Devices)
-
CP60333
Same Sky (Formerly CUI Devices)

-
CP60231H
Same Sky (Formerly CUI Devices)

-
CP60301531H
Same Sky (Formerly CUI Devices)
-
CP20351
Same Sky (Formerly CUI Devices)
-
CP30338
Same Sky (Formerly CUI Devices)

-
CM29-1.9-04AC
Marlow Industries, Inc.
-
CP85438
Same Sky (Formerly CUI Devices)

-
RC6-4-01LS
Marlow Industries, Inc.
Tech Hub
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…
LDO regulator guide covering low dropout voltage, power dissipation, thermal design, PSRR, output noise, capacitor stability, adjustable LDO circuits, LDO vs buck converter and datasheet selection chec…
Conditional Access Module guide covering CAM meaning, CI/CI+ interface, smart card authorization, DVB security workflow, TV and set-top box compatibility, internal electronics, ESD protection, connecto…
Guide to electronic component obsolescence covering EOL risk, PCN/PDN notices, last-time buy planning, replacement options, form-fit-function validation, counterfeit risk and BOM lifecycle management.
18650 battery guide covering lithium-ion cell basics, 3.6V/3.7V voltage, 4.2V charging, mAh and Wh capacity, protected cells, chargers, BMS, series-parallel packs, holders, welding and sourcing checks.…
Hall effect sensor guide covering working principle, linear and digital sensors, Arduino circuits, current sensing, speed detection, automotive applications, A3144 examples, signal filtering and datash…
Product Change Notification guide for electronic components, covering PCN meaning, PCN vs PDN/EOL, common change types, risk levels, form-fit-function review, engineering validation, BOM control, LTB/L…
A practical guide to blend door actuators, covering HVAC function, symptoms, location, AC and heater issues, reset and calibration, replacement cost, electrical diagnosis, compatibility checks, and rep…
Engineering guide to Raspberry Pi alternatives, covering chip-level differences, Orange Pi, ROCK, Jetson, Banana Pi, NanoPi, Compute Module, Pico, GPIO, camera, HAT compatibility, and replacement risks…