RFbeam Microwave GmbH K-LC6
- Part No.:
- K-LC6
- Manufacturer:
- RFbeam Microwave GmbH
- Category:
- RF Transceiver Modules and Modems
- Package:
- 8-DIP Module
- Datasheet:
-
K-LC6.pdf
- Description:
- RF TXRX MOD RADAR CER PATCH TH
- Quantity:
- Payment:

- Shipping:

Inventory:1,253
Please send an inquiry. Send us your inquiry, and we will respond immediately.
K-LC6 Specifications
- Product attributes
- Attribute value
- Manufacturer:
- RFbeam Microwave GmbH
- Series:
- K-LC
- Package/Case:
- 8-DIP Module
- Packaging:
- Tray
- Product Status:
- Obsolete
- Programmable:
- Not Verified
- RF Family/Standard:
- Radar
- Protocol:
- -
- Modulation:
- -
- Frequency:
- 24.05GHz ~ 24.25GHz
- Data Rate:
- -
- Power - Output:
- 18dBm
- Sensitivity:
- -126dBc
- Serial Interfaces:
- -
- Antenna Type:
- Integrated, Ceramic Patch
- Utilized IC / Part:
- -
- Memory Size:
- -
- Voltage - Supply:
- 4.75V ~ 5.25V
- Current - Receiving:
- 50mA
- Current - Transmitting:
- 50mA
- Mounting Type:
- Through Hole
- Operating Temperature:
- -20°C ~ 80°C
K-LC6 FAQ
1.How can I place an order for K-LC6 through Aetrix?
Please submit a Request for Quotation (RFQ) for K-LC6 on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for K-LC6 reliable?
The price and inventory of K-LC6 are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for K-LC6 is usually 5 days.
3.What payment methods are accepted for K-LC6?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for K-LC6 transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for K-LC6?
K-LC6 orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your K-LC6 order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for K-LC6?
For technical support, including K-LC6 datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your K-LC6 requirements.
6.How does Aetrix verify that K-LC6 is sourced from the original manufacturer or authorized distributors?
All K-LC6 products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that K-LC6 meets industry standards.
7.What is the process for return or replacement of K-LC6?
All K-LC6 units undergo pre-shipment inspection (PSI). If there is an issue with K-LC6, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The K-LC6 part is unused and in its original packaging.
Return procedure for K-LC6:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
K-LC6 Tags

-
ESP32-C3FH4
Espressif Systems

-
ESP32-S2FH4
Espressif Systems

-
ESP32-S2FN4R2
Espressif Systems

-
ESP32-C3-MINI-1-N4
Espressif Systems

-
ESP32-C3-WROOM-02-N4
Espressif Systems

-
ESP32-C3-MINI-1U-N4
Espressif Systems

-
ESP32-C3-MINI-1U-H4
Espressif Systems

-
ESP32-C3-WROOM-02U-N4
Espressif Systems

-
ESP32-H2-MINI-1-N4
Espressif Systems

-
ESP32-H2-MINI-1-H4
Espressif Systems
_viewa.jpg)
-
ESP32-MINI-1-N4
Espressif Systems

-
ESP32-S2-MINI-2-N4R2
Espressif Systems
Tech Hub
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…
LDO regulator guide covering low dropout voltage, power dissipation, thermal design, PSRR, output noise, capacitor stability, adjustable LDO circuits, LDO vs buck converter and datasheet selection chec…
Conditional Access Module guide covering CAM meaning, CI/CI+ interface, smart card authorization, DVB security workflow, TV and set-top box compatibility, internal electronics, ESD protection, connecto…
Guide to electronic component obsolescence covering EOL risk, PCN/PDN notices, last-time buy planning, replacement options, form-fit-function validation, counterfeit risk and BOM lifecycle management.
18650 battery guide covering lithium-ion cell basics, 3.6V/3.7V voltage, 4.2V charging, mAh and Wh capacity, protected cells, chargers, BMS, series-parallel packs, holders, welding and sourcing checks.…
Hall effect sensor guide covering working principle, linear and digital sensors, Arduino circuits, current sensing, speed detection, automotive applications, A3144 examples, signal filtering and datash…
Product Change Notification guide for electronic components, covering PCN meaning, PCN vs PDN/EOL, common change types, risk levels, form-fit-function review, engineering validation, BOM control, LTB/L…
A practical guide to blend door actuators, covering HVAC function, symptoms, location, AC and heater issues, reset and calibration, replacement cost, electrical diagnosis, compatibility checks, and rep…
Engineering guide to Raspberry Pi alternatives, covering chip-level differences, Orange Pi, ROCK, Jetson, Banana Pi, NanoPi, Compute Module, Pico, GPIO, camera, HAT compatibility, and replacement risks…
Engineering guide to dynamic load response testing for high-current buck converters, covering load step setup, slew rate, Vcore undershoot, overshoot, recovery time, probe location, output capacitors a…