Cantherm L50NG913-240-600MM
- Part No.:
- L50NG913-240-600MM
- Manufacturer:
- Cantherm
- Category:
- Thermal Cutoffs (Thermal Fuses)
- Package:
- Cylinder, Wire Leads
- Datasheet:
-
L50NG913-240-600MM.pdf
- Description:
- TCO 250VAC 15A 240C (464F) CYL
- Quantity:
- Payment:

- Shipping:

Inventory:6,812
Please send an inquiry. Send us your inquiry, and we will respond immediately.
L50NG913-240-600MM Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Cantherm
- Package/Case:
- Cylinder, Wire Leads
- Series:
- L50
- Packaging:
- Bulk
- Product Status:
- Active
- Type:
- Fuse
- Holding Temperature:
- 200°C (392°F)
- Rated Functioning Temperature:
- 240°C (464°F)
- Reset Temperature:
- -
- Voltage Rating - AC:
- 250.0
- Voltage Rating - DC:
- -
- Current Rating (Amps):
- 15 A
- Approval Agency:
- VDE
- Maximum Temperature Limit:
- 260°C (500°F)
L50NG913-240-600MM FAQ
1.How can I place an order for L50NG913-240-600MM through Aetrix?
Please submit a Request for Quotation (RFQ) for L50NG913-240-600MM on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for L50NG913-240-600MM reliable?
The price and inventory of L50NG913-240-600MM are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for L50NG913-240-600MM is usually 5 days.
3.What payment methods are accepted for L50NG913-240-600MM?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for L50NG913-240-600MM transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for L50NG913-240-600MM?
L50NG913-240-600MM orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your L50NG913-240-600MM order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for L50NG913-240-600MM?
For technical support, including L50NG913-240-600MM datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your L50NG913-240-600MM requirements.
6.How does Aetrix verify that L50NG913-240-600MM is sourced from the original manufacturer or authorized distributors?
All L50NG913-240-600MM products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that L50NG913-240-600MM meets industry standards.
7.What is the process for return or replacement of L50NG913-240-600MM?
All L50NG913-240-600MM units undergo pre-shipment inspection (PSI). If there is an issue with L50NG913-240-600MM, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The L50NG913-240-600MM part is unused and in its original packaging.
Return procedure for L50NG913-240-600MM:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
L50NG913-240-600MM Tags

-
SDF DF128S
Cantherm

-
SDF DF141S
Cantherm

-
SDF DF184S
Cantherm

-
SDF DF240S
Cantherm

-
SDF DF104S
Cantherm

-
SA72SB0
Bourns Inc.

-
DFP10112
TDK-Lambda

-
SD90WBB
Bourns Inc.

-
L5010024DELB0XE
Cantherm

-
SDF DF144S
Cantherm
-
SDF DF098S
Cantherm

-
SDF DF077S
Cantherm
Tech Hub
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…
LDO regulator guide covering low dropout voltage, power dissipation, thermal design, PSRR, output noise, capacitor stability, adjustable LDO circuits, LDO vs buck converter and datasheet selection chec…
Conditional Access Module guide covering CAM meaning, CI/CI+ interface, smart card authorization, DVB security workflow, TV and set-top box compatibility, internal electronics, ESD protection, connecto…
Guide to electronic component obsolescence covering EOL risk, PCN/PDN notices, last-time buy planning, replacement options, form-fit-function validation, counterfeit risk and BOM lifecycle management.
18650 battery guide covering lithium-ion cell basics, 3.6V/3.7V voltage, 4.2V charging, mAh and Wh capacity, protected cells, chargers, BMS, series-parallel packs, holders, welding and sourcing checks.…
Hall effect sensor guide covering working principle, linear and digital sensors, Arduino circuits, current sensing, speed detection, automotive applications, A3144 examples, signal filtering and datash…
Product Change Notification guide for electronic components, covering PCN meaning, PCN vs PDN/EOL, common change types, risk levels, form-fit-function review, engineering validation, BOM control, LTB/L…
A practical guide to blend door actuators, covering HVAC function, symptoms, location, AC and heater issues, reset and calibration, replacement cost, electrical diagnosis, compatibility checks, and rep…
Engineering guide to Raspberry Pi alternatives, covering chip-level differences, Orange Pi, ROCK, Jetson, Banana Pi, NanoPi, Compute Module, Pico, GPIO, camera, HAT compatibility, and replacement risks…
Engineering guide to dynamic load response testing for high-current buck converters, covering load step setup, slew rate, Vcore undershoot, overshoot, recovery time, probe location, output capacitors a…