Analog Devices Inc./Maxim Integrated MAX1060AEEI+
- Part No.:
- MAX1060AEEI+
- Manufacturer:
- Analog Devices Inc./Maxim Integrated
- Category:
- Analog to Digital Converters (ADC)
- Package:
- 28-SSOP (0.154", 3.90mm Width)
- Datasheet:
-
MAX1060AEEI+.pdf
- Description:
- IC ADC 10BIT SAR 28QSOP
- Quantity:
- Payment:

- Shipping:

Inventory:2,910
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MAX1060AEEI+ from Maxim Integrated is a 10-bit successive-approximation analog-to-digital converter (ADC) with 8-channel single-ended or 4-channel pseudo-differential input, internal +2.5V reference, byte-wide parallel (8+2) interface, and operation from a single +5V analog supply with user-adjustable digital logic level (+2.7V to +5.5V). It delivers 400ksps sampling rate, ±0.5 LSB INL, and 2.5mA supply current at full speed, targeting battery-powered data acquisition and industrial sensor interfacing.
For engineers reviewing the MAX1060AEEI+ datasheet, MAX1060AEEI+ pinout, MAX1060AEEI+ application, or MAX1060AEEI+ equivalent, key selection criteria include its software-configurable unipolar/bipolar input mode, fast 2µs wake-up from shutdown, internal track-and-hold with 6MHz full-power bandwidth, and QSOP-28 package compatibility with industrial temperature range (–40°C to +85°C).
Technical Context
The MAX1060AEEI+ implements a charge-redistribution SAR architecture with integrated track-and-hold, supporting both internal and external clock modes (7.6MHz max) and internal/external acquisition control via configurable control byte. Its analog front-end allows dynamic reconfiguration between single-ended (CH0–CH7) and pseudo-differential (CH0/CH1, CH2/CH3, etc.) input pairs, with COM referenced zero-code voltage.
Digital interface uses active-low CS, WR, RD, and INT signals with HBEN-controlled 10-bit data multiplexing (D0/D8 and D1/D9), enabling direct connection to 8-bit microprocessors. Power management includes two software-selectable power-down modes reducing supply current to <2µA in shutdown, while maintaining fast wake-up and stable reference performance across temperature.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Resolution | 10-bit - supports precise digitization of sensor outputs and control loop feedback signals within ±0.5 LSB INL error band. |
| Sampling Rate | 400ksps maximum - enables real-time capture of transients up to 350kHz full-linear bandwidth without aliasing when paired with anti-alias filtering. |
| Analog Input Configuration | 8-channel single-ended or 4-channel pseudo-differential - provides flexible signal routing for multi-sensor systems without external MUX hardware. |
| Reference | +2.5V internal bandgap reference (±20ppm/°C TC, ±100mV adjust range) - eliminates need for external reference IC in space-constrained designs. |
| Supply Current | 2.5mA at 400ksps, 400µA at 10ksps, 2µA in shutdown - enables ultra-low-power operation in duty-cycled measurement systems. |
| Digital Interface | Byte-wide parallel (D0–D7) + D8/D9 multiplexed via HBEN - simplifies µP interfacing with standard 8-bit data buses and avoids serial protocol overhead. |
| Operating Temperature | –40°C to +85°C - qualified for deployment in industrial control cabinets, energy meters, and medical monitoring equipment. |
Pinout & Package
MAX1060AEEI+ is housed in a 28-pin QSOP package (5.3mm × 10.2mm, 0.65mm pitch), optimized for high-density PCB layouts and automated assembly. Pin functions are validated per Maxim's official pin description table and functional diagram.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 HBEN | High-byte enable control | Selects whether D0/D8 and D1/D9 carry MSBs (HBEN=1) or LSBs (HBEN=0); enables 10-bit readout over 8-bit bus. |
| 10 INT | Interrupt output | Active-low signal indicates conversion completion and data validity; synchronizes µP read timing without polling. |
| 11 RD | Read strobe input | Falling edge latches conversion result onto D0–D7 bus when CS is low; supports non-intrusive status checking. |
| 12 WR | Write strobe input | Rising edge loads control byte (channel select, unipolar/bipolar, acquisition mode) and initiates conversion sequence. |
| 13 CLK | Clock input | Accepts external 100kHz–7.6MHz TTL/CMOS clock or connects to VDD/GND for internal clock mode. |
| 14 CS | Chip select | Active-low enables digital interface; places D0–D7 in high-impedance state when deasserted to prevent bus contention. |
| 15–22 CH0–CH7 | Analog input channels | Eight single-ended inputs or four differential pairs; each protected by internal clamping diodes (GND−0.3V to VDD+0.3V). |
| 23 COM | Analog common reference | Sets zero-code voltage in single-ended mode; must remain stable to ±0.5 LSB during conversion. |
| 25 REFADJ | Reference buffer control | Connect to VDD to disable internal reference when using external REF source; bypass with 0.01µF capacitor. |
| 26 REF | Reference I/O | Outputs +2.5V internal reference or accepts external reference; requires 4.7µF capacitor to GND for stability. |
| 27 VDD | Analog supply | +5V ±10% analog power rail; bypass with 0.1µF capacitor to GND near pin for noise suppression. |
| 28 VLOGIC | Digital supply | +2.7V to +5.5V logic-level supply; decouples digital I/O voltage from analog domain for mixed-signal integrity. |
Key Features
| Feature | Design Value |
|---|---|
| Software-configurable input topology | Runtime selection of unipolar/bipolar and single-ended/pseudo-differential modes via control byte - eliminates hardware redesign for varying sensor signal types. |
| Internal +2.5V reference with trim capability | ±20ppm/°C tempco and ±100mV REFADJ adjustment range - ensures stable accuracy across industrial temperature range without external components. |
| Low-power shutdown with fast wake-up | 2µA shutdown current and 2µs wake-up time - enables microsecond-scale duty cycling for ultra-low average power in portable instrumentation. |
| Integrated track-and-hold with 6MHz bandwidth | Eliminates need for external T/H amplifier; supports undersampling of high-frequency signals beyond Nyquist limit with proper anti-alias filtering. |
| Parallel (8+2) interface with HBEN multiplexing | Enables 10-bit data transfer using standard 8-bit µP data bus - reduces PCB trace count and simplifies firmware driver development. |
Applications
| Industrial Process Monitoring | Patient Vital Sign Acquisition |
|---|---|
Use Scenario: Continuous logging of temperature, pressure, and flow sensor outputs in PLC-based control systems. IC Role / Device Role / Timing Role: Primary ADC digitizing 8 analog sensor channels with programmable gain and bipolar input support for 4–20mA loop interfaces. Use Value: Single-chip solution reduces BOM count and layout area versus discrete MUX + ADC combinations while maintaining ±0.5 LSB linearity over –40°C to +85°C. |
Use Scenario: Multi-parameter bedside monitor capturing ECG, respiration, and SpO₂ analog waveforms. IC Role / Device Role / Timing Role: Low-noise, low-power ADC acquiring synchronized biopotential signals with 400ksps burst capability and fast wake-up from sleep between measurements. Use Value: Internal +2.5V reference and 2µA shutdown current extend battery life in portable monitors without sacrificing DC accuracy or dynamic range. |
| Energy Meter Data Capture | Automated Test Equipment (ATE) Front-End |
Use Scenario: High-accuracy voltage and current sampling in Class 0.5 smart electricity meters. IC Role / Device Role / Timing Role: Precision ADC converting isolated shunt/sense transformer outputs with software-selectable unipolar/bipolar range to accommodate different CT ratios. Use Value: ±0.5 LSB INL and ±1 LSB DNL ensure metrology-grade linearity; 350kHz full-linear bandwidth supports harmonic analysis up to 50th order. |
Use Scenario: Modular ATE channel card digitizing DUT analog outputs under tight timing control. IC Role / Device Role / Timing Role: Triggered ADC with external acquisition mode and precise WR/CLK timing for deterministic sampling windows aligned to stimulus signals. Use Value: External acquisition control and 200ps aperture jitter (with external clock) enable sub-ns timing resolution critical for parametric test repeatability. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar 10-bit parallel ADC applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MAX1061AEEI+ | +3V analog supply (vs. +5V), identical pinout and feature set except lower supply voltage and reduced full-power bandwidth (3MHz vs. 6MHz). | Better suited for low-voltage embedded systems where +5V rail is unavailable; not drop-in compatible due to VDD voltage requirement mismatch. | Select MAX1061AEEI+ only when system-level power architecture mandates +3V analog operation and 3MHz bandwidth suffices. |
| ADS7822U | 8-bit resolution, SPI interface, +2.7V to +5.25V supply, no internal reference - requires external REF and serial interface logic. | Targets cost-sensitive, lower-precision applications with existing SPI infrastructure; lacks parallel bus simplicity and on-chip reference of MAX1060AEEI+. | Choose ADS7822U when board space permits serial interface and 8-bit resolution meets accuracy requirements, avoiding parallel bus routing complexity. |
Compared with MAX1061AEEI+ and ADS7822U, the MAX1060AEEI+ uniquely combines +5V operation, 10-bit precision, internal +2.5V reference, and parallel interface in a single 28-pin QSOP - making it optimal for industrial data loggers requiring minimal external components and deterministic µP access latency.
Availability
MAX1060AEEI+ is available at Aetrix Electronics and suitable for industrial process monitoring, patient vital sign acquisition, energy meter data capture, and automated test equipment requiring stable component supply across extended temperature ranges and long production lifecycles.
Supply support for MAX1060AEEI+ includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Maxim Integrated (now part of Analog Devices) is a semiconductor company specializing in high-performance analog, mixed-signal, and power management ICs for industrial, medical, and communications applications.
The MAX1060AEEI+ belongs to Maxim's precision data acquisition product line, designed specifically for space- and power-constrained systems needing reliable, easy-to-integrate ADC functionality with minimal external components.
FAQ
What is the operating temperature range of the MAX1060AEEI+?
The MAX1060AEEI+ is rated for operation from –40°C to +85°C, as confirmed by its "AEEI" suffix ordering code and electrical specifications tables covering that full industrial temperature range. This makes the MAX1060AEEI+ suitable for deployment in harsh environments such as factory automation controllers, outdoor energy meters, and portable medical devices without thermal derating.
Does the MAX1060AEEI+ require an external reference voltage?
No, the MAX1060AEEI+ includes a precision +2.5V internal bandgap reference with ±20ppm/°C temperature coefficient and ±100mV adjustment range via REFADJ. An external reference is optional and only needed when higher initial accuracy or different reference voltage is required; the internal reference eliminates BOM cost and board space for most applications.
How does the HBEN pin function in the MAX1060AEEI+?
The HBEN (High Byte Enable) pin on the MAX1060AEEI+ controls multiplexing of the 10-bit conversion result onto the 8-bit data bus: when HBEN = 1, D0/D8 and D1/D9 carry the two most significant bits (MSBs); when HBEN = 0, they carry the two least significant bits (LSBs). This allows full 10-bit readout using standard 8-bit microprocessor buses without additional latches or glue logic.
Can the MAX1060AEEI+ operate with a 3.3V digital supply?
Yes, the MAX1060AEEI+ supports digital logic supply voltages from +2.7V to +5.5V on the VLOGIC pin, fully compatible with 3.3V systems. The digital I/O levels (VIH/VIL, VOH/VOL) are specified down to VLOGIC = 2.7V, ensuring robust interfacing with 3.3V µPs and FPGAs while maintaining separate +5V analog supply (VDD) for optimal SNR performance.
What power-down modes are available on the MAX1060AEEI+?
The MAX1060AEEI+ offers two software-selectable power-down modes controlled by PD0/PD1 bits in the configuration byte: standby mode (reducing IDD to ~10µA) and full power-down mode (reducing IDD to 2µA). Both retain register settings and allow wake-up in 2µs via WR or CS assertion, enabling aggressive power cycling in battery-operated data loggers without losing configuration state.
MAX1060AEEI+ Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Analog Devices Inc./Maxim Integrated
- Series:
- -
- Package/Case:
- 28-SSOP (0.154", 3.90mm Width)
- Packaging:
- Tube
- Product Status:
- Obsolete
- Number of Bits:
- 10
- Sampling Rate (Per Second):
- 400k
- Number of Inputs:
- 4, 8
- Input Type:
- Pseudo-Differential, Single Ended
- Data Interface:
- Parallel
- Configuration:
- MUX-S/H-ADC
- Ratio - S/H:ADC:
- 1:1
- Number of A/D Converters:
- 1
- Architecture:
- SAR
- Reference Type:
- External, Internal
- Voltage - Supply, Analog:
- 5V
- Voltage - Supply, Digital:
- 2.7V ~ 5.5V
- Features:
- -
- Operating Temperature:
- -40°C ~ 85°C
- Supplier Device Package:
- 28-QSOP
- Mounting Type:
- Surface Mount
- Grade:
- -
- Qualification:
- -
MAX1060AEEI+ FAQ
1.How can I place an order for MAX1060AEEI+ through Aetrix?
Please submit a Request for Quotation (RFQ) for MAX1060AEEI+ on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MAX1060AEEI+ reliable?
The price and inventory of MAX1060AEEI+ are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MAX1060AEEI+ is usually 5 days.
3.What payment methods are accepted for MAX1060AEEI+?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MAX1060AEEI+ transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MAX1060AEEI+?
MAX1060AEEI+ orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MAX1060AEEI+ order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MAX1060AEEI+?
For technical support, including MAX1060AEEI+ datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MAX1060AEEI+ requirements.
6.How does Aetrix verify that MAX1060AEEI+ is sourced from the original manufacturer or authorized distributors?
All MAX1060AEEI+ products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MAX1060AEEI+ meets industry standards.
7.What is the process for return or replacement of MAX1060AEEI+?
All MAX1060AEEI+ units undergo pre-shipment inspection (PSI). If there is an issue with MAX1060AEEI+, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MAX1060AEEI+ part is unused and in its original packaging.
Return procedure for MAX1060AEEI+:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MAX1060AEEI+ Tags

-
ADC081C021CIMKX/NOPB
Texas Instruments

-
MCP3021A5T-E/OT
Microchip Technology

-
TLA2024IRUGR
Texas Instruments

-
MCP3221A5T-E/OT
Microchip Technology

-
MCP3221A5T-I/OT
Microchip Technology

-
MCP3221A4T-E/OT
Microchip Technology

-
MCP3221A6T-E/OT
Microchip Technology

-
MCP3221A0T-E/OT
Microchip Technology

-
MCP3221A1T-E/OT
Microchip Technology

-
ADC121S021CIMFX/NOPB
Texas Instruments

-
MCP3001-I/MS
Microchip Technology

-
MCP3001-I/SN
Microchip Technology
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…

