Analog Devices Inc./Maxim Integrated MAX1189ACUI+

Part No.:
MAX1189ACUI+
Manufacturer:
Analog Devices Inc./Maxim Integrated
Category:
Analog to Digital Converters (ADC)
Package:
28-TSSOP (0.173", 4.40mm Width)
Datasheet:
AetrixMAX1189ACUI+.pdf
Description:
IC ADC 16BIT SAR 28TSSOP
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:3,021

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

MAX1189ACUI+ from Maxim Integrated is a 16-bit, 135ksps successive-approximation ADC with ±10V bipolar analog input range, single +4.75V to +5.25V analog supply, and 16-bit parallel interface. It features ±2LSB INL, -100dB THD, and operates across 0°C to +70°C in a 28-pin TSSOP package - ideal for precision industrial process control and medical instrumentation requiring high DC accuracy and low distortion.

For engineers reviewing the MAX1189ACUI+ datasheet, MAX1189ACUI+ pinout, MAX1189ACUI+ application, or MAX1189ACUI+ equivalent, key selection criteria include its ±10V input range compatibility, internal +4.096V reference (±35ppm/°C tempco), 5.3mA analog supply current with external reference, AutoShutdown™ mode (5µA), and TSSOP-28 footprint suitability for space-constrained data-acquisition systems.

Technical Context

The MAX1189ACUI+ implements a SAR architecture with integrated track-and-hold, factory-trimmed internal clock, and input scaler enabling true ±10V bipolar operation from a single +5V analog supply. Its offset binary coding supports full-scale range of ±20V (FSR = +20V), with 1LSB = (FSR × VREF)/(65536 × 4.096).

Power management is controlled via R/C pin timing: second CS falling edge selects standby (reference/buffer active, 3.7mA) or shutdown (reference/buffer off, 0.5µA). Conversion completes in 4.7µs max after hold-mode initiation, with EOC signaling data readiness and three-state D0–D15 outputs synchronized to CS edges.

Key Specifications

ParameterValue and Actual Design Meaning
Resolution16-bit - delivers 65,536 discrete output codes for high-resolution measurement
Sampling Rate135ksps - supports real-time acquisition of signals up to ~67kHz Nyquist bandwidth
Analog Input Range±10V - enables direct interfacing with industrial sensors and transducers without external scaling
INL (max)±2LSB - ensures monotonicity and <0.003% full-scale linearity error for calibration-critical applications
THD-100dB - minimizes harmonic contamination in spectral analysis and audio-grade signal capture
Supply Current (ext ref)5.3mA - enables battery-powered operation at 135ksps with minimal thermal load
AutoShutdown Current5µA - reduces idle power by >1000×, critical for intermittent-sampling portable instruments

Pinout & Package

MAX1189ACUI+ is housed in a 28-pin Thin Shrink Small Outline Package (TSSOP), 4.4mm × 9.7mm body, 0.65mm pitch, with exposed pad for thermal enhancement. Pin 1 marked via dot; recommended PCB layout uses separate AGND/DGND planes joined at single point near AVDD/DVDD decoupling.

Pin/TerminalCircuit RoleDesign Meaning
D0–D15Three-state digital data outputs16-bit parallel bus interface; high-impedance during acquisition/conversion, driven only after third CS edge with R/C high
R/CRead/Convert control inputConfigures power state: low on second CS edge → standby (ref/buffer on); high → shutdown (ref/buffer off)
EOCEnd-of-conversion flagActive-low open-drain output signals valid data ready; used to trigger µP read cycle
CSConvert start inputFalling-edge-triggered control: first edge powers up/acquires, second starts conversion, third loads bus
AINAnalog input terminalAccepts ±10V differential input relative to AGND; internal scaler handles level-shifting and attenuation
REF / REFADJReference input/output and adjustmentREF = buffered +4.096V output (internal ref) or 3.8–4.2V input (external ref); REFADJ adjusts internal ref or disables buffer when tied to AVDD
AVDD / DVDDAnalog/digital supply inputsAVDD: +4.75V to +5.25V; DVDD: +2.7V to +5.25V - allows mixed-voltage system interfacing
AGND / DGNDAnalog/digital ground terminalsSeparate ground pins require star-point connection to minimize noise coupling between analog and digital domains

Key Features

FeatureDesign Value
±10V bipolar input rangeEliminates need for external op-amp level-shifting circuitry when measuring ±10V sensor outputs
Internal +4.096V referenceProvides stable, factory-trimmed reference with ±35ppm/°C drift - sufficient for 16-bit accuracy without external ref IC
AutoShutdown™ modeReduces total supply current to 5µA between conversions, extending battery life in portable DAQ systems
16-bit parallel interfaceEnables direct connection to microcontroller data buses without serial-to-parallel conversion latency or firmware overhead
Offset binary codingSupports signed ±10V interpretation directly: 0x0000 = -10V, 0x8000 = 0V, 0xFFFF = +10V – simplifies firmware scaling

Applications

Industrial Process ControlPrecision Instrumentation

Use Scenario: Monitoring temperature, pressure, and flow in PLC I/O modules with 4–20mA loop interfaces.

IC Role / Device Role / Timing Role: Primary ADC converting conditioned analog sensor outputs into 16-bit digital values for real-time control algorithms.

Use Value: ±2LSB INL and -100dB THD ensure accurate closed-loop feedback without recalibration drift over temperature.

Use Scenario: High-fidelity data logging in portable multimeters and oscilloscope front-ends.

IC Role / Device Role / Timing Role: High-speed sampling core capturing transient waveforms with minimal harmonic distortion.

Use Value: 135ksps rate and 90dB SINAD enable clean spectral analysis of signals up to 67kHz without aliasing artifacts.

Medical Patient MonitoringBattery-Powered Data Acquisition

Use Scenario: ECG and EEG signal digitization in bedside monitors requiring low-noise, low-power analog front-ends.

IC Role / Device Role / Timing Role: Low-distortion ADC acquiring biopotential signals with ±10V common-mode rejection capability.

Use Value: Internal reference stability (±35ppm/°C) and 0.6LSB RMS noise maintain diagnostic-grade signal fidelity across clinical environments.

Use Scenario: Field-deployable environmental sensors logging voltage outputs from thermocouples and strain gauges.

IC Role / Device Role / Timing Role: Power-gated ADC operating intermittently to extend AA/AAA battery life beyond 12 months.

Use Value: 5µA AutoShutdown current and 12ms wake-up time from shutdown enable ultra-low average power without sacrificing 16-bit resolution.

Equivalent & Alternatives

The following parts are listed as comparable options for similar 16-bit SAR ADC applications.

Alternative PartTechnical DifferenceApplication DifferenceSelection Advice
ADS8860IDRCT16-bit, 1MSPS, SPI interface, ±VREF input (not ±10V native), requires external ref; 1.8V/3.3V supply onlyHigher speed but no native ±10V input - needs external gain/level-shift for industrial sensorsSelect when system prioritizes throughput over input range simplicity and uses modern low-voltage µCs
AD7606BSTZ16-bit, 200ksps, simultaneous sampling, ±10V input supported, but requires external reference and dual supplies (+5V/+2.5V)Multi-channel sync sampling for motor control; higher power (120mW) and larger LQFP-64 packageSelect for multi-sensor synchronized acquisition where channel correlation matters more than single-channel power efficiency

Compared with ADS8860IDRCT and AD7606BSTZ, the MAX1189ACUI+ uniquely combines native ±10V bipolar input, internal reference, 16-bit parallel interface, and 5µA shutdown - making it optimal for cost-sensitive, space-constrained, single-channel industrial DAQ where ease of analog interface and ultra-low idle power are critical.

Availability

MAX1189ACUI+ is available at Aetrix Electronics and suitable for industrial process control, precision instrumentation, and medical patient monitoring requiring stable component supply and long-term production continuity.

Supply support for MAX1189ACUI+ includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

Maxim Integrated (now part of Analog Devices) designs precision analog, mixed-signal, and power management ICs for demanding industrial, medical, and communications applications.

The MAX1189ACUI+ belongs to Maxim's high-accuracy SAR ADC product line, engineered specifically for battery-powered and space-constrained data-acquisition systems needing wide input range, low power, and minimal external components.

FAQ

What is the maximum sampling rate of the MAX1189ACUI+?

The MAX1189ACUI+ achieves a maximum sampling rate of 135ksps. This is specified under conditions of AVDD = DVDD = +5V ±5%, external reference = +4.096V, and CLOAD = 20pF. At this rate, the device consumes 5.3mA with external reference or 6.2mA with internal reference, and conversion time is guaranteed ≤4.7µs. The MAX1189ACUI+ maintains ±2LSB INL and -100dB THD performance across its full rated sampling range.

Does the MAX1189ACUI+ support ±10V analog input natively?

Yes, the MAX1189ACUI+ supports a native ±10V bipolar analog input range referenced to AGND. This is achieved via an internal input scaler that attenuates and shifts the signal to match the DAC range, eliminating the need for external op-amp level-shifting circuitry. The transfer function uses offset binary coding: 0x0000 = -10V, 0x8000 = 0V, 0xFFFF = +10V. Input resistance is 6kΩ in shutdown mode and 5.3mA supply current applies during active conversion.

How does the AutoShutdown™ feature work on the MAX1189ACUI+?

The AutoShutdown™ feature on the MAX1189ACUI+ is controlled by the R/C pin during the second falling edge of CS. Setting R/C high places the device in shutdown mode, powering down the internal reference and buffer to reduce total supply current to 5µA. Setting R/C low enters standby mode (3.7mA), keeping reference/buffer active for faster wake-up. After shutdown, 12ms is required for the internal reference to settle before achieving 16-bit accuracy - a timing constraint critical for low-duty-cycle applications.

What reference options does the MAX1189ACUI+ support?

The MAX1189ACUI+ supports both internal and external reference configurations. Its internal trimmed reference provides +4.096V at REF with ±35ppm/°C tempco and requires 10µF bypassing to AGND. For external reference, drive REF with a 3.8V–4.2V source capable of 100µA DC load and ≤10Ω output impedance; alternatively, use REFADJ as a buffered external reference input (5kΩ impedance), disabling the internal buffer by tying REFADJ to AVDD.

Is the MAX1189ACUI+ pin-compatible with other devices in the MAX1179/MAX1187/MAX1189 family?

Yes, the MAX1189ACUI+ is pin-compatible with MAX1179ACUI+ and MAX1187ACUI+ within the same TSSOP-28 package. All share identical pinout, timing, and interface logic. The primary differences lie in input range (±10V vs. ±5V vs. 0–10V) and minor INL grading (all ±2LSB for 'A' grade). Firmware and PCB layout can be reused across the family, allowing design flexibility for varying sensor interface requirements without hardware revision.

MAX1189ACUI+ Specifications

Product attributes
Attribute value
Manufacturer:
Analog Devices Inc./Maxim Integrated
Series:
-
Package/Case:
28-TSSOP (0.173", 4.40mm Width)
Packaging:
Tube
Product Status:
Active
Number of Bits:
16
Sampling Rate (Per Second):
135k
Number of Inputs:
1
Input Type:
Single Ended
Data Interface:
Parallel
Configuration:
S/H-ADC
Ratio - S/H:ADC:
1:1
Number of A/D Converters:
1
Architecture:
SAR
Reference Type:
External, Internal
Voltage - Supply, Analog:
5V
Voltage - Supply, Digital:
2.7V ~ 5.25V
Features:
-
Operating Temperature:
0°C ~ 70°C
Supplier Device Package:
28-TSSOP
Mounting Type:
Surface Mount
Grade:
-
Qualification:
-

MAX1189ACUI+ FAQ

1.How can I place an order for MAX1189ACUI+ through Aetrix?

Please submit a Request for Quotation (RFQ) for MAX1189ACUI+ on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for MAX1189ACUI+ reliable?

The price and inventory of MAX1189ACUI+ are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MAX1189ACUI+ is usually 5 days.

3.What payment methods are accepted for MAX1189ACUI+?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MAX1189ACUI+ transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for MAX1189ACUI+?

MAX1189ACUI+ orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your MAX1189ACUI+ order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for MAX1189ACUI+?

For technical support, including MAX1189ACUI+ datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MAX1189ACUI+ requirements.

6.How does Aetrix verify that MAX1189ACUI+ is sourced from the original manufacturer or authorized distributors?

All MAX1189ACUI+ products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MAX1189ACUI+ meets industry standards.

7.What is the process for return or replacement of MAX1189ACUI+?

All MAX1189ACUI+ units undergo pre-shipment inspection (PSI). If there is an issue with MAX1189ACUI+, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The MAX1189ACUI+ part is unused and in its original packaging.

Return procedure for MAX1189ACUI+:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

MAX1189ACUI+ Tags

  • MAX1189ACUI+
  • MAX1189ACUI+ PDF
  • MAX1189ACUI+ Datasheet
  • MAX1189ACUI+ Specifications
  • MAX1189ACUI+ Images
  • Analog Devices Inc./Maxim Integrated
  • Analog Devices Inc./Maxim Integrated MAX1189ACUI+
  • Buy MAX1189ACUI+
  • MAX1189ACUI+ Price
  • MAX1189ACUI+ Distributor
  • MAX1189ACUI+ Supplier
  • MAX1189ACUI+ Wholesale
Related Products
ADC081C021CIMKX/NOPB
ADC081C021CIMKX/NOPB

Texas Instruments

MCP3021A5T-E/OT
MCP3021A5T-E/OT

Microchip Technology

TLA2024IRUGR
TLA2024IRUGR

Texas Instruments

MCP3221A5T-E/OT
MCP3221A5T-E/OT

Microchip Technology

MCP3221A5T-I/OT
MCP3221A5T-I/OT

Microchip Technology

MCP3221A4T-E/OT
MCP3221A4T-E/OT

Microchip Technology

MCP3221A6T-E/OT
MCP3221A6T-E/OT

Microchip Technology

MCP3221A0T-E/OT
MCP3221A0T-E/OT

Microchip Technology

MCP3221A1T-E/OT
MCP3221A1T-E/OT

Microchip Technology

ADC121S021CIMFX/NOPB
ADC121S021CIMFX/NOPB

Texas Instruments

MCP3001-I/MS
MCP3001-I/MS

Microchip Technology

MCP3001-I/SN
MCP3001-I/SN

Microchip Technology

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER