Send an Inquiry

To receive a quote for your project, please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Part Number*
Quantity*
Message
Submit Inventory List

Please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Upload My List
Message

Analog Devices Inc./Maxim Integrated MAX14803CCM+

Part No.:
MAX14803CCM+
Manufacturer:
Analog Devices Inc./Maxim Integrated
Category:
Analog Switches, Multiplexers, Demultiplexers
Package:
48-LQFP
Datasheet:
AetrixMAX14803CCM+.pdf
Description:
IC SW SPST-NOX16 48OHM 48LQFP
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:199

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

MAX14803CCM+ from Maxim Integrated is a 16-channel, high-voltage analog SPST switch IC designed for ultrasound imaging probe and printer high-voltage signal routing. It features HVCMOS process technology, 16 individually programmable switches, integrated 35kΩ bleed resistors per terminal, and operates with VPP/VNN up to +100V/–100V (200V total) or +40V/–160V (200V total). Its 20MHz serial interface and low 5µA quiescent current support precision medical transducer control.

For engineers reviewing the MAX14803CCM+ datasheet, MAX14803CCM+ pinout, MAX14803CCM+ application, or MAX14803CCM+ equivalent, key selection criteria include its 48-pin LQFP package, commercial temperature range (0°C to +70°C), integrated bleed resistors (distinguishing it from MAX14802), ±100V/–100V high-voltage supply capability, and daisy-chainable 16-bit serial interface with latch enable and clear inputs.

Technical Context

The MAX14803CCM+ implements a 16-bit serial shift register with transparent latch, enabling precise channel-by-channel switching control via DIN/CLK/LE/CLR signals referenced to a separate +2.7V to +5.5V VDD supply. Its analog path supports DC-to-20MHz signal bandwidth with <3.5µs turn-on/off time and –77dB off-isolation at 5MHz (RL = 50Ω).

Each of the 16 COM_/NO_ switch pairs includes clamping diodes at COM_ for positive overvoltage protection and-uniquely among the family-integrated 35kΩ bleed resistors to discharge capacitive loads like piezoelectric transducers. Power-on reset ensures all switches default open.

Key Specifications

ParameterValue and Actual Design Meaning
VPP/VNN Supply Range+40V to +100V / –160V to –100V; supports asymmetric configurations including +40V/–160V, +100V/–100V, and +200V/0V (max 250V differential)
Switch On-Resistance (RONS)22Ω typ at +100V/–100V, 5mA; enables low-loss high-current switching up to 3A peak per channel
Charge Injection600pC typ at +100V/–100V; minimizes voltage glitch on sensitive transducer nodes during switching
Off-Isolation–77dB typ at 5MHz (RL = 50Ω); ensures high channel-to-channel signal integrity in multi-element arrays
Serial Interface Speed20MHz max CLK frequency at VDD = +5V; supports fast reconfiguration of all 16 channels in ≤800ns
Quiescent Current (VDD)5µA typ; reduces standby power in battery-backed or thermally constrained ultrasound systems
Operating Temperature0°C to +70°C (commercial grade); validated for use in non-implantable diagnostic equipment enclosures

Pinout & Package

MAX14803CCM+ is housed in a 48-pin LQFP (7mm × 7mm) package with exposed pad, RoHS-compliant (indicated by '+' suffix), and thermal resistance θJA = 44°C/W on a four-layer board.

Pin/TerminalCircuit RoleDesign Meaning
COM0–COM15, NO0–NO1516× Analog Switch TerminalsHigh-voltage SPST switch common/normally-open pairs; each supports ±100V/–100V operation and includes internal bleed resistor (35kΩ to GND) and COM-side clamp diode
VPP, VNNHigh-Voltage SuppliesVPP = +40V to +100V, VNN = –160V to –100V; must be bypassed with ≥0.1µF ceramic caps close to pins
VDD, GNDDigital Supply & ReferenceVDD = +2.7V to +5.5V logic supply; GND serves as digital and analog reference for level shifters and bleed resistors
DIN, CLK, LE, CLR, DOUTSerial Control InterfaceCMOS-level signals referenced to VDD; LE active-low latches 16-bit data; CLR high resets all switches open; DOUT enables daisy-chaining
N.C.No Connection42 pins marked N.C. - not internally bonded; must remain unconnected per datasheet

Key Features

FeatureDesign Value
Integrated 35kΩ Bleed ResistorsDischarges piezoelectric transducer capacitance automatically after switching, eliminating external RC networks and reducing PCB area
Clamping Diodes at COM_Protects downstream circuitry from positive voltage overshoot up to VPP + 0.3V, critical in pulsed ultrasound transmit paths
Daisy-Chainable Serial InterfaceEnables scalable control of multiple MAX14803CCM+ devices using single microcontroller SPI port, simplifying large-channel-count probe designs
Power-On ResetGuarantees all 16 switches start in open (off) state at power-up, preventing unintended high-voltage connection during system initialization
Low-Charge Injection (600pC)Minimizes transient voltage error on high-impedance transducer nodes, preserving echo signal fidelity in receive-mode timing accuracy

Applications

Ultrasound Probe MultiplexingMedical Ultrasound Mainframe Transmit Switching

Use Scenario: Routing high-voltage excitation pulses across 64–128 transducer elements in handheld or cart-based diagnostic probes.

IC Role / Device Role / Timing Role: 16-channel SPST switch providing channel-select isolation and voltage translation between FPGA-controlled drivers and piezoelectric elements.

Use Value: Integrated bleed resistors discharge element capacitance between pulses, enabling faster frame rates without external discharge circuitry.

Use Scenario: High-voltage switching of transmit waveforms in central ultrasound mainframe units before distribution to probe cables.

IC Role / Device Role / Timing Role: Precision analog switch managing ±100V, 1–2A pulsed outputs under tight timing control (≤3.5µs tON/tOFF) from FPGA sequencers.

Use Value: –77dB off-isolation at 5MHz prevents crosstalk between adjacent transmit channels, maintaining beamforming accuracy.

Industrial Printer Head DriverHigh-Voltage Test Equipment Multiplexer

Use Scenario: Selecting and driving high-voltage piezoelectric print heads in wide-format inkjet printers requiring >100V actuation.

IC Role / Device Role / Timing Role: 16-channel analog switch delivering controlled ±100V pulses to individual nozzle actuators via serial command.

Use Value: 20MHz serial interface allows real-time nozzle activation sequencing synchronized to print head motion.

Use Scenario: Automated test systems routing high-voltage calibration signals (±100V) to multiple DUT inputs while maintaining isolation.

IC Role / Device Role / Timing Role: High-reliability SPST switch providing safe, software-controlled access to test points under 200V differential stress.

Use Value: Integrated clamping diodes protect test instrumentation from accidental overvoltage events during probing.

Equivalent & Alternatives

The following parts are listed as comparable options for similar high-voltage analog switching applications.

Alternative PartTechnical DifferenceApplication DifferenceSelection Advice
MAX14802CCM+No integrated bleed resistors; identical pinout, package, and temperature range (0°C to +70°C)Suitable where external discharge circuitry is already present or transducer capacitance is negligibleSelect MAX14802CCM+ only if bleed resistors are unnecessary and cost optimization is prioritized
MAX14803AEWZ+110-bump WLP package; extended temperature range (–40°C to +85°C); same bleed resistors and OVPRequired for space-constrained or extended-temperature industrial ultrasound modulesChoose MAX14803AEWZ+ when board area is limited or operating beyond +70°C is required

Compared with MAX14802CCM+, MAX14803CCM+ adds essential bleed resistors for transducer discharge without layout changes; compared with MAX14803AEWZ+, it trades WLP miniaturization and extended temperature for lower-cost LQFP assembly and commercial-grade qualification.

Availability

MAX14803CCM+ is available at Aetrix Electronics and suitable for ultrasound imaging systems, industrial printers, and high-voltage test equipment requiring stable component supply, long-term production continuity, and RoHS-compliant packaging.

Supply support for MAX14803CCM+ includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

Maxim Integrated (now part of Analog Devices) designs precision analog, mixed-signal, and high-voltage ICs for medical, industrial, and communications applications.

The MAX1480x family targets high-voltage analog switching in ultrasound and printing systems, emphasizing low charge injection, integrated protection, and robust serial control for demanding signal-path applications.

FAQ

What is the maximum allowable VPP–VNN differential voltage for MAX14803CCM+?

The MAX14803CCM+ supports a maximum VPP–VNN differential of 250V, as confirmed in the Absolute Maximum Ratings table. For the MAX14803CCM+ variant specifically, this is achieved with configurations such as +100V/–100V (200V), +40V/–160V (200V), or +200V/0V (200V). The datasheet explicitly states "(MAX14802CCM+, MAX14803CCM+)… VPP – VNN Supply Voltage = 260V" is not permitted; the correct limit is 250V per the Electrical Characteristics section and ordering guide.

Does MAX14803CCM+ include bleed resistors, and how do they function?

Yes, MAX14803CCM+ includes integrated 35kΩ bleed resistors on each COM_ and NO_ terminal, connecting to GND. These resistors automatically discharge capacitive loads (e.g., piezoelectric transducers) after switch turn-off, eliminating the need for external discharge circuits. This feature distinguishes MAX14803CCM+ from MAX14802CCM+ and is confirmed in the General Description, Functional Diagram footnote, and Ordering Information table.

What is the operating temperature range specified for MAX14803CCM+?

The MAX14803CCM+ is specified for the commercial temperature range of 0°C to +70°C, as stated in both the General Description and the Ordering Information/Selector Guide. This is distinct from the extended-range MAX14803AEWZ+ (–40°C to +85°C) and MAX14802ECM+ (–40°C to +85°C), and applies to all electrical characteristics unless otherwise noted.

Can MAX14803CCM+ be daisy-chained with other devices, and what pins enable this?

Yes, MAX14803CCM+ supports daisy-chaining via its DOUT pin, which outputs shifted data delayed by 16 clock cycles. To chain multiple devices, connect DOUT of one MAX14803CCM+ to DIN of the next, while sharing CLK, LE, and CLR across all devices. This configuration is documented in Figure 3 and Applications Information, enabling scalable control of large switch arrays from a single microcontroller SPI interface.

How does the power-on reset function behave in MAX14803CCM+?

The MAX14803CCM+ incorporates an internal power-on reset circuit that forces all 16 switches to the open (off) state at power-up, regardless of input conditions. This behavior is guaranteed by design and ensures safe default operation in ultrasound and printer systems where unintended high-voltage connection could damage transducers or print heads. The reset affects both the 16-bit shift register and latch, as described in the Detailed Description section.

MAX14803CCM+ Specifications

Product attributes
Attribute value
Manufacturer:
Analog Devices Inc./Maxim Integrated
Series:
-
Packaging:
Tray
Product Status:
Active
Switch Circuit:
SPST - NO
Multiplexer/Demultiplexer Circuit:
1:1
Number of Circuits:
16
On-State Resistance (Max):
48Ohm
Channel-to-Channel Matching (ΔRon):
2.4Ohm
Voltage - Supply, Single (V+):
40V ~ 250V
Voltage - Supply, Dual (V±):
±160V
Switch Time (Ton, Toff) (Max):
3.5µs, 3.5µs
-3db Bandwidth:
20MHz
Charge Injection:
820pC
Channel Capacitance (CS(off), CD(off)):
11pF
Current - Leakage (IS(off)) (Max):
2µA
Crosstalk:
-80dB @ 5MHz
Operating Temperature:
0°C ~ 70°C (TA)
Grade:
-
Qualification:
-
Mounting Type:
Surface Mount
Supplier Device Package:
48-LQFP (7x7)

MAX14803CCM+ FAQ

1.How can I place an order for MAX14803CCM+ through Aetrix?

Please submit a Request for Quotation (RFQ) for MAX14803CCM+ on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for MAX14803CCM+ reliable?

The price and inventory of MAX14803CCM+ are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MAX14803CCM+ is usually 5 days.

3.What payment methods are accepted for MAX14803CCM+?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MAX14803CCM+ transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for MAX14803CCM+?

MAX14803CCM+ orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your MAX14803CCM+ order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for MAX14803CCM+?

For technical support, including MAX14803CCM+ datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MAX14803CCM+ requirements.

6.How does Aetrix verify that MAX14803CCM+ is sourced from the original manufacturer or authorized distributors?

All MAX14803CCM+ products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MAX14803CCM+ meets industry standards.

7.What is the process for return or replacement of MAX14803CCM+?

All MAX14803CCM+ units undergo pre-shipment inspection (PSI). If there is an issue with MAX14803CCM+, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The MAX14803CCM+ part is unused and in its original packaging.

Return procedure for MAX14803CCM+:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

MAX14803CCM+ Tags

  • MAX14803CCM+
  • MAX14803CCM+ PDF
  • MAX14803CCM+ Datasheet
  • MAX14803CCM+ Specifications
  • MAX14803CCM+ Images
  • Analog Devices Inc./Maxim Integrated
  • Analog Devices Inc./Maxim Integrated MAX14803CCM+
  • Buy MAX14803CCM+
  • MAX14803CCM+ Price
  • MAX14803CCM+ Distributor
  • MAX14803CCM+ Supplier
  • MAX14803CCM+ Wholesale
Related Products
SN74LVC1G3157DBVR
SN74LVC1G3157DBVR

Texas Instruments

SN74LVC1G66DBVR
SN74LVC1G66DBVR

Texas Instruments

SN74LVC1G66DCKR
SN74LVC1G66DCKR

Texas Instruments

SN74LVC1G3157DSFR
SN74LVC1G3157DSFR

Texas Instruments

1P1G3157QDCKRQ1
1P1G3157QDCKRQ1

Texas Instruments

SN74LVC2G66DCUR
SN74LVC2G66DCUR

Texas Instruments

SN74LV4052APWR
SN74LV4052APWR

Texas Instruments

74HC4051D,653
74HC4051D,653

Nexperia USA Inc.

SN74LV4051APWR
SN74LV4051APWR

Texas Instruments

CD74HC4052PWR
CD74HC4052PWR

Texas Instruments

CD74HC4051PWR
CD74HC4051PWR

Texas Instruments

TS5A3166DBVR
TS5A3166DBVR

Texas Instruments

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER