Analog Devices Inc./Maxim Integrated MAX31850TATB+
- Part No.:
- MAX31850TATB+
- Manufacturer:
- Analog Devices Inc./Maxim Integrated
- Category:
- Sensor and Detector Interfaces
- Package:
- 10-WFDFN Exposed Pad
- Datasheet:
-
MAX31850TATB+.pdf
- Description:
- IC CONV THRMCPLE-DIG T TYPE TDFN
- Quantity:
- Payment:

- Shipping:

Inventory:4,488
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MAX31850TATB+ from Maxim Integrated is a cold-junction compensated, 1-Wire thermocouple-to-digital converter optimized for Type T thermocouples. It delivers 14-bit resolution (0.25°C), supports -270°C to +400°C thermocouple range, features integrated open/short fault detection, and operates with parasite or local VDD power. It is used in industrial temperature monitoring where distributed, low-wiring-count sensing is required.
For engineers reviewing the MAX31850TATB+ datasheet, MAX31850TATB+ pinout, MAX31850TATB+ application, or MAX31850TATB+ equivalent, key selection considerations include its 0.25°C resolution, Type T thermocouple calibration, parasitic-power capability, 1-Wire multdrop support, and ±2°C thermocouple accuracy over -270°C to +400°C.
Technical Context
The MAX31850TATB+ integrates a precision 14-bit ADC, dedicated cold-junction temperature sensor (±2°C error), and analog signal conditioning circuitry tailored to Type T thermocouple's 52.18 µV/°C sensitivity. Its internal conversion path includes switch-controlled routing (S1–S5) to isolate thermocouple inputs during cold-junction measurement and fault detection phases.
It implements full 1-Wire protocol compliance-including presence detection, time-slot timing (60–120 µs slot), and CRC-8 validation-with a unique 64-bit ROM ID. The AD0–AD3 address pins configure location mapping, and fault status bits (open, short-to-GND/VDD) are embedded directly in scratchpad bytes 2 and 3.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Thermocouple Type | Type T (copper/constantan), factory-trimmed for 52.18 µV/°C nominal sensitivity |
| Temperature Resolution | 0.25°C (thermocouple), 0.0625°C (cold-junction), enabling fine-grained thermal profiling |
| Thermocouple Range | -270°C to +400°C - covers full operational span of Type T sensors including cryogenic use |
| Accuracy (Thermocouple) | ±2°C (−270°C to +400°C, TA = −40°C to +125°C), excluding thermocouple nonlinearity correction |
| Cold-Junction Error | ±2°C (TA = −40°C to +100°C), ensuring reliable ambient compensation across industrial environments |
| Conversion Time | 72–100 ms per full cycle (thermocouple + cold-junction + fault detection), deterministic for scheduling |
| Power Modes | Local VDD (3.0–3.7 V) or parasite power via DQ - eliminates external supply in space-constrained nodes |
Pinout & Package
TDFN-EP (3mm × 4mm, 10-pin, exposed pad). Pin 10 (DNC) is unconnected; EP may be grounded or left floating.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| GND (Pin 1) | Ground reference | Common return for thermocouple, internal circuitry, and parasitic power discharge path |
| T− (Pin 2) | Thermocouple negative input | Connected to constantan wire; must not be shorted to GND to avoid fault false positives |
| T+ (Pin 3) | Thermocouple positive input | Connected to copper wire; forms differential input pair with T− for noise-rejected voltage sensing |
| VDD (Pin 4) | Supply voltage input | Required for local power mode; must be tied to GND in parasite-power operation |
| DQ (Pin 5) | 1-Wire data I/O & parasite power | Open-drain bidirectional bus interface; supplies device current during high bus states via CPP capacitor |
| AD0–AD3 (Pins 6–9) | Location address inputs | Hardwired LSB–MSB address bits (0–15); read back via configuration register byte 4 for multi-node mapping |
Key Features
| Feature | Design Value |
|---|---|
| Integrated cold-junction compensation | On-die temperature sensor with ±2°C accuracy enables true remote junction measurement without external ICs |
| Type T–specific analog front-end | Factory-calibrated gain and offset for 52.18 µV/°C response eliminates software linearization for base-range measurements |
| Hardware fault detection | Dedicated circuitry flags open thermocouple, short-to-GND, and short-to-VDD on T+/T− - reported in scratchpad byte 2 |
| 1-Wire multdrop architecture | Single microcontroller can manage >100 units on one bus using unique 64-bit ROM IDs - reduces wiring and GPIO count |
| Parasite-power compatibility | Operates with no local VDD; powered entirely from 1-Wire bus via DQ - ideal for sealed or inaccessible sensor nodes |
Applications
| Industrial Process Monitoring | HVAC System Control |
|---|---|
Use Scenario: Real-time temperature logging across kilometer-scale boiler feedwater lines with minimal cabling. IC Role / Device Role / Timing Role: Direct thermocouple digitization and cold-junction compensation at point-of-sense; 1-Wire bus enables daisy-chained deployment. Use Value: Eliminates analog signal degradation over long runs and removes need for centralized signal conditioning hardware. |
Use Scenario: Distributed duct temperature sensing in commercial HVAC with zone-level feedback control. IC Role / Device Role / Timing Role: Local cold-junction compensated Type T conversion; AD0–AD3 pins assign fixed physical locations for automated commissioning. Use Value: Reduces installation labor by 60% vs. RS-485 nodes; enables plug-and-play sensor replacement without reconfiguration. |
| Medical Sterilization Validation | Appliance Safety Monitoring |
Use Scenario: Multi-point temperature verification inside autoclave chambers during steam sterilization cycles. IC Role / Device Role / Timing Role: High-accuracy Type T interface with fault detection; operates reliably at up to +125°C ambient. Use Value: Ensures regulatory compliance (ISO 17665) by detecting open thermocouples before cycle start - preventing invalid batches. |
Use Scenario: Overtemperature cutoff in induction cooktops using embedded Type T sensors near heating coils. IC Role / Device Role / Timing Role: Fast 100 ms conversion with integrated fault reporting; VDD-powered for robustness under EMI-rich conditions. Use Value: Enables Class B safety certification by providing fail-safe open-circuit detection within <1 s of disconnection. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar thermocouple-to-digital conversion applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MAX31855KASA+ | Thermocouple type K only; SPI interface; no 1-Wire or ADx address pins; higher quiescent current (1.5 µA vs. 280 nA) | Requires dedicated SPI lines per device; unsuitable for large multdrop networks | Select when SPI host interface exists and K-type thermocouples dominate; avoid for distributed 1-Wire systems |
| ADS1118IDGST | General-purpose 16-bit delta-sigma ADC with internal temp sensor; no built-in cold-junction compensation or thermocouple-specific calibration | Requires external cold-junction sensor and software linearization; increases BOM and firmware complexity | Select when mixed-sensor designs (voltage, RTD, thermocouple) share same ADC; not drop-in for MAX31850TATB+ |
Compared with MAX31855KASA+, MAX31850TATB+ reduces system wiring and microcontroller GPIO usage via 1-Wire multdrop and location addressing; compared with ADS1118IDGST, it delivers out-of-box Type T accuracy without calibration overhead or external components.
Availability
MAX31850TATB+ is available at Aetrix Electronics and suitable for industrial process monitoring, HVAC system control, medical sterilization validation, and appliance safety monitoring requiring stable component supply and long-term lifecycle support.
Supply support for MAX31850TATB+ includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Maxim Integrated (now part of Analog Devices) designs precision analog and mixed-signal ICs for demanding industrial, medical, and automotive applications.
The MAX31850 series targets distributed temperature sensing systems requiring minimal wiring, self-identifying nodes, and factory-calibrated thermocouple interfaces - emphasizing reliability, fault resilience, and ease of integration.
FAQ
What thermocouple types does the MAX31850TATB+ support?
The MAX31850TATB+ is factory trimmed and calibrated specifically for Type T thermocouples (copper/constantan), with nominal sensitivity of 52.18 µV/°C. It does not support other thermocouple types - variants like MAX31850K or MAX31851R are required for K-, R-, or S-type sensors. Using a non-Type T thermocouple with MAX31850TATB+ results in significant measurement error due to mismatched gain and offset.
How does the MAX31850TATB+ handle open or shorted thermocouple wires?
The MAX31850TATB+ includes dedicated hardware fault detection that automatically identifies open circuits, shorts to GND, and shorts to VDD on the T+ and T− inputs. These conditions are encoded in bits 0–2 of scratchpad byte 2: bit 0 = open, bit 1 = short-to-GND, bit 2 = short-to-VDD. This status is latched and readable without interrupting normal temperature conversions.
Can the MAX31850TATB+ operate without an external power supply?
Yes, the MAX31850TATB+ supports parasite power mode: it draws operating current from the 1-Wire bus via the DQ pin and stores charge on an internal capacitor (CPP). In this mode, VDD must be connected to GND. A strong pullup (e.g., MOSFET-switched rail) is required during temperature conversions (72–100 ms) to sustain >1 mA peak current - standard 4.7 kΩ pullups are insufficient.
What is the role of the AD0–AD3 pins on the MAX31850TATB+?
The AD0–AD3 pins on the MAX31850TATB+ are hardwired location address inputs (LSB to MSB) that configure a 4-bit node identifier (0–15). This value is stored in bits [3:0] of the configuration register (scratchpad byte 4) and enables deterministic addressing in multi-device 1-Wire networks - eliminating reliance on ROM search algorithms during initialization.
What is the temperature accuracy specification for the MAX31850TATB+ over its full range?
The MAX31850TATB+ achieves ±2°C thermocouple temperature accuracy over the full −270°C to +400°C range when ambient temperature is between −40°C and +125°C. This includes contributions from gain/offset error and cold-junction compensation error but excludes thermocouple wire nonlinearity - which must be corrected in host firmware using NIST ITS-90 tables.
MAX31850TATB+ Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Analog Devices Inc./Maxim Integrated
- Package/Case:
- 10-WFDFN Exposed Pad
- Series:
- -
- Packaging:
- Tube
- Product Status:
- Active
- Programmable:
- Not Verified
- Type:
- Thermocouple to Digital Converter
- Input Type:
- Thermocouple (Multiple)
- Output Type:
- Digital
- Current - Supply:
- 900 µA
- Operating Temperature:
- -40°C ~ 125°C
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Surface Mount
- Supplier Device Package:
- 10-TDFN (3x4)
MAX31850TATB+ FAQ
1.How can I place an order for MAX31850TATB+ through Aetrix?
Please submit a Request for Quotation (RFQ) for MAX31850TATB+ on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MAX31850TATB+ reliable?
The price and inventory of MAX31850TATB+ are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MAX31850TATB+ is usually 5 days.
3.What payment methods are accepted for MAX31850TATB+?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MAX31850TATB+ transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MAX31850TATB+?
MAX31850TATB+ orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MAX31850TATB+ order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MAX31850TATB+?
For technical support, including MAX31850TATB+ datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MAX31850TATB+ requirements.
6.How does Aetrix verify that MAX31850TATB+ is sourced from the original manufacturer or authorized distributors?
All MAX31850TATB+ products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MAX31850TATB+ meets industry standards.
7.What is the process for return or replacement of MAX31850TATB+?
All MAX31850TATB+ units undergo pre-shipment inspection (PSI). If there is an issue with MAX31850TATB+, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MAX31850TATB+ part is unused and in its original packaging.
Return procedure for MAX31850TATB+:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MAX31850TATB+ Tags

-
RE46C100S8TF
Microchip Technology

-
XTR111AIDRCR
Texas Instruments

-
XTR111AIDGQR
Texas Instruments
-
XTR117AIDGKR
Texas Instruments

-
XTR111AIDGQT
Texas Instruments

-
XTR115UA/2K5
Texas Instruments

-
MAX14626ETT+T
Analog Devices Inc./Maxim Integrated

-
XTR116UA/2K5
Texas Instruments

-
XTR115U/2K5
Texas Instruments

-
XTR116U/2K5
Texas Instruments
-
PGA308AIDGSR
Texas Instruments

-
XTR300AIRGWR
Texas Instruments
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…