Analog Devices Inc./Maxim Integrated MAX355CPE+

Part No.:
MAX355CPE+
Manufacturer:
Analog Devices Inc./Maxim Integrated
Category:
Analog Switches, Multiplexers, Demultiplexers
Package:
16-DIP (0.300", 7.62mm)
Datasheet:
AetrixMAX355CPE+.pdf
Description:
IC SWITCH SP4T X 2 350OHM 16DIP
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:4,148

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

MAX355CPE+ from Maxim Integrated is a dual 4-channel fault-protected analog multiplexer IC designed for high-reliability signal routing in industrial and avionics systems. It operates from ±4.5V to ±18V dual supplies (or +4.5V to +36V single supply), delivers 350Ω max on-resistance, guarantees break-before-make switching, and withstands ±40V overvoltage with supplies off. It is used in ATE equipment for robust analog channel selection under fault conditions.

For engineers reviewing the MAX355CPE+ datasheet, MAX355CPE+ pinout, MAX355CPE+ application, or MAX355CPE+ equivalent, key selection criteria include fault protection level (±40V with supplies off), leakage current (<0.5nA at +25°C), on-resistance matching (≤15Ω), logic compatibility (TTL/CMOS without pull-ups), and dual 4-channel topology with independent COMA/COMB outputs.

Technical Context

The MAX355CPE+ implements a series N-channel/P-channel/N-channel FET structure that actively clamps overvoltage inputs to ~1.5V below supply rails while limiting fault current to sub-microamp levels. Its digital interface uses fixed 0.8V/2.4V logic thresholds referenced to GND, ensuring TTL/CMOS compatibility across temperature and supply variations.

All eight analog terminals (NO1A–NO4A, NO1B–NO4B, COMA, COMB) are bidirectional and electrically identical. The device guarantees break-before-make timing (≥100ns) and supports demultiplexing operation with full fault protection-unlike earlier generations-while maintaining <5nA leakage at +85°C and <0.1pC charge injection at ±15V supplies.

Key Specifications

Parameter Value and Actual Design Meaning
Supply Range±4.5V to ±18V dual or +4.5V to +36V single - enables operation in harsh industrial rails and legacy ±15V systems
On-Resistance (RON)350Ω max - ensures minimal signal attenuation and gain error in precision data acquisition paths
Input Leakage Current<0.5nA at +25°C - preserves high-impedance sensor node integrity and reduces offset drift
Fault Protection±40V with supplies off - protects downstream ADCs and amplifiers during power sequencing or rail collapse
Break-Before-Make Interval≥100ns - prevents momentary input-to-input shorting during channel switching in redundant systems
Logic Thresholds0.8V low / 2.4V high - eliminates need for external pull-up resistors when interfacing with standard microcontrollers
Charge Injection80pC max at ±15V - limits voltage glitch on 1000pF loads to ≤80mV, critical for S/H accuracy

Pinout & Package

MAX355CPE+ is housed in a 16-pin plastic DIP package (0.300" wide) with through-hole mounting and industry-standard footprint. Pin 1 is marked by a notch or dot; pin numbering follows standard counter-clockwise convention from top-left corner.

Pin/Terminal Circuit Role Design Meaning
A0, A1Binary address inputsSelect one of four channels per section (COMA or COMB); logic thresholds fixed at 0.8V/2.4V
ENActive-high enable inputDisables all switches when low; guarantees all channels OFF with supplies off
V+, V−Power supply railsV− connects to GND for single-supply use; total rail span defines RON and signal swing
GNDAnalog/digital referenceCommon return for logic thresholds and internal clamp circuitry; forms isolation barrier
NO1A–NO4A, NO1B–NO4BBidirectional analog I/OElectrically identical; support mux/demux modes with full fault protection in both directions
COMA, COMBIndependent common outputsEach serves its own 4-channel group; no internal connection between COMA and COMB

Key Features

Feature Design Value
Fault protection with supplies offWithstands ±40V continuous overvoltage at any analog terminal while drawing <100nA total leakage
Output clamping behaviorClamps active output to ~1.5V below V+ and ~3V above V−, preserving polarity and preventing latch-up
No power-up sequencing requiredOperates safely regardless of V+/V− ramp order or timing - eliminates system-level sequencing complexity
Demultiplexing capabilitySupports true bidirectional signal flow: analog input applied to COMA/COMB routes to selected NOx terminal
Low crosstalk isolation92dB typical off-isolation at 100kHz (RL = 1.5kΩ) - maintains signal integrity in multi-channel mixed-signal systems

Applications

ATE Equipment Avionics Signal Routing

Use Scenario: Automated test systems route sensor and actuator signals across hundreds of DUT channels under varying fault conditions.

IC Role / Device Role / Timing Role: Dual 4-channel analog multiplexer providing isolated, fault-tolerant signal path selection with guaranteed break-before-make timing.

Use Value: Enables uninterrupted testing during ±40V transients (e.g., ESD events or power rail faults) without damaging measurement front-ends or requiring external protection diodes.

Use Scenario: Flight control computers switch between primary and backup sensor inputs (e.g., airspeed, angle-of-attack) in real time.

IC Role / Device Role / Timing Role: Fault-protected analog switch ensuring fail-safe redundancy switching with no input shorting or polarity reversal during overvoltage events.

Use Value: Maintains signal continuity and polarity integrity even when sensors experience lightning-induced transients up to ±40V, meeting DO-160 Section 22 requirements.

Industrial Process Control Data-Acquisition Systems

Use Scenario: PLC analog I/O modules condition and route 4–20mA or ±10V field signals from valves, transmitters, and actuators.

IC Role / Device Role / Timing Role: High-voltage-tolerant multiplexer handling multiple sensor inputs while surviving wiring faults and ground loops.

Use Value: Eliminates need for discrete TVS diodes and series resistors per channel, reducing BOM count and PCB area in DIN-rail mounted controllers.

Use Scenario: Precision DAQ systems sample thermocouples, strain gauges, and RTDs across multiple channels with minimal crosstalk and offset drift.

IC Role / Device Role / Timing Role: Low-leakage (0.5nA), low-RON (350Ω), matched-channel analog switch enabling 16-bit+ resolution measurements.

Use Value: Delivers <0.001% gain error and <1µV offset contribution over temperature, supporting IEEE 1057-compliant calibration routines.

Equivalent & Alternatives

The following parts are listed as comparable options for similar analog multiplexer applications.

Alternative Part Technical Difference Application Difference Selection Advice
ADG509FKNZPin-compatible but lacks ±40V fault protection with supplies off; max overvoltage = ±20V with supplies on onlySuitable for benign environments where power remains stable; not rated for ATE or avionics fault transientsSelect ADG509FKNZ only if system-level protection already exists and ±40V-with-supplies-off immunity is unnecessary
DG459DN-E3Same dual 4-channel topology but no integrated fault-protection circuitry; requires external clamps and current limitingUsed in cost-sensitive industrial designs where board space allows discrete protection componentsChoose DG459DN-E3 when BOM flexibility and lower unit cost outweigh integration benefits and reliability assurance

Compared with ADG509FKNZ and DG459DN-E3, the MAX355CPE+ provides unique integrated fault protection that eliminates external components, guarantees safe operation during power loss, and maintains signal polarity - making it the only option qualified for unattended ATE and safety-critical avionics routing.

Availability

MAX355CPE+ is available at Aetrix Electronics and suitable for ATE equipment, avionics signal routing, and industrial process control requiring stable component supply, long-term lifecycle support, and guaranteed fault-protection performance across temperature extremes.

Supply support for MAX355CPE+ includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

Maxim Integrated (now part of Analog Devices) is a fabless semiconductor company specializing in high-performance analog, mixed-signal, and power management ICs for demanding industrial, automotive, and communications applications.

The MAX354/MAX355 product line was engineered specifically for fault-tolerant analog signal routing in mission-critical systems where overvoltage survival, power sequencing independence, and bidirectional demux capability are mandatory design requirements.

FAQ

What is the maximum overvoltage the MAX355CPE+ can withstand with power supplies disconnected?

The MAX355CPE+ withstands continuous ±40V overvoltage at any analog input or output terminal-even when V+ and V− are at 0V. This is achieved via its series N/P/N FET structure, which blocks conduction while limiting leakage to <100nA. This capability is explicitly tested and guaranteed per Absolute Maximum Ratings, making MAX355CPE+ suitable for systems subject to wiring faults or uncontrolled power-down sequences.

Does the MAX355CPE+ support demultiplexing operation, and how is fault protection maintained in that mode?

Yes, the MAX355CPE+ fully supports demultiplexing: an analog signal applied to COMA or COMB routes to the selected NOxA or NOxB channel, with identical fault protection as in multiplexing mode. When operated as a demux, overvoltage on any NOx terminal still triggers the same clamp action-output voltage is limited to ~1.5V below V+ or ~3V above V−-and all unselected channels remain safely isolated. This bidirectional protection is confirmed in the Detailed Description section and functional diagrams.

What is the guaranteed on-resistance matching between channels of the MAX355CPE+?

The MAX355CPE+ guarantees ∆RON ≤ 15Ω across all channels at TA = TMIN to TMAX, defined as RON(MAX) − RON(MIN). This matching ensures consistent gain and settling behavior when switching between channels in precision applications like calibrated DAQ systems. At +25°C, typical matching is tighter (≤7Ω), and the specification is verified across the full operating temperature range per Electrical Characteristics table.

Can the MAX355CPE+ operate from a single +12V supply, and what are the implications for analog signal range?

Yes, the MAX355CPE+ operates from a single +12V supply with V− tied to GND. In this configuration, the analog signal range is limited to approximately 0V to +10.5V (V+ − 1.5V), as the output clamps 1.5V below V+. The on-resistance increases slightly versus ±15V operation (typical 400Ω vs. 350Ω), and switching times lengthen by ~2×, but break-before-make timing and logic compatibility remain fully functional per the Electrical Characteristics table and Typical Operating Characteristics plots.

How does the MAX355CPE+ ensure TTL/CMOS logic compatibility without external pull-up resistors?

The MAX355CPE+ features fixed 0.8V logic-low and 2.4V logic-high thresholds referenced to GND-guaranteed across temperature and supply voltage. Input current remains <1µA at all logic levels, eliminating loading concerns. This allows direct interface with standard microcontroller GPIOs, FPGA I/O banks, and ASIC drivers without pull-ups, as confirmed in the Digital Interface Levels section and Electrical Characteristics table (VA_L/VA_H parameters).

MAX355CPE+ Specifications

Product attributes
Attribute value
Manufacturer:
Analog Devices Inc./Maxim Integrated
Series:
-
Packaging:
Tube
Product Status:
Active
Switch Circuit:
SP4T
Multiplexer/Demultiplexer Circuit:
4:1
Number of Circuits:
2
On-State Resistance (Max):
350Ohm
Channel-to-Channel Matching (ΔRon):
7Ohm
Voltage - Supply, Single (V+):
4.5V ~ 36V
Voltage - Supply, Dual (V±):
±4.5V ~ 18V
Switch Time (Ton, Toff) (Max):
250ns, 200ns
-3db Bandwidth:
-
Charge Injection:
80pC
Channel Capacitance (CS(off), CD(off)):
1.6pF, 5pF
Current - Leakage (IS(off)) (Max):
500pA
Crosstalk:
-92dB @ 100kHz
Operating Temperature:
0°C ~ 70°C (TA)
Grade:
-
Qualification:
-
Mounting Type:
Through Hole
Supplier Device Package:
16-PDIP

MAX355CPE+ FAQ

1.How can I place an order for MAX355CPE+ through Aetrix?

Please submit a Request for Quotation (RFQ) for MAX355CPE+ on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for MAX355CPE+ reliable?

The price and inventory of MAX355CPE+ are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MAX355CPE+ is usually 5 days.

3.What payment methods are accepted for MAX355CPE+?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MAX355CPE+ transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for MAX355CPE+?

MAX355CPE+ orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your MAX355CPE+ order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for MAX355CPE+?

For technical support, including MAX355CPE+ datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MAX355CPE+ requirements.

6.How does Aetrix verify that MAX355CPE+ is sourced from the original manufacturer or authorized distributors?

All MAX355CPE+ products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MAX355CPE+ meets industry standards.

7.What is the process for return or replacement of MAX355CPE+?

All MAX355CPE+ units undergo pre-shipment inspection (PSI). If there is an issue with MAX355CPE+, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The MAX355CPE+ part is unused and in its original packaging.

Return procedure for MAX355CPE+:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

MAX355CPE+ Tags

  • MAX355CPE+
  • MAX355CPE+ PDF
  • MAX355CPE+ Datasheet
  • MAX355CPE+ Specifications
  • MAX355CPE+ Images
  • Analog Devices Inc./Maxim Integrated
  • Analog Devices Inc./Maxim Integrated MAX355CPE+
  • Buy MAX355CPE+
  • MAX355CPE+ Price
  • MAX355CPE+ Distributor
  • MAX355CPE+ Supplier
  • MAX355CPE+ Wholesale
Related Products
SN74LVC1G3157DBVR
SN74LVC1G3157DBVR

Texas Instruments

SN74LVC1G66DBVR
SN74LVC1G66DBVR

Texas Instruments

SN74LVC1G66DCKR
SN74LVC1G66DCKR

Texas Instruments

SN74LVC1G3157DSFR
SN74LVC1G3157DSFR

Texas Instruments

1P1G3157QDCKRQ1
1P1G3157QDCKRQ1

Texas Instruments

SN74LVC2G66DCUR
SN74LVC2G66DCUR

Texas Instruments

SN74LV4052APWR
SN74LV4052APWR

Texas Instruments

74HC4051D,653
74HC4051D,653

Nexperia USA Inc.

SN74LV4051APWR
SN74LV4051APWR

Texas Instruments

CD74HC4052PWR
CD74HC4052PWR

Texas Instruments

CD74HC4051PWR
CD74HC4051PWR

Texas Instruments

TS5A3166DBVR
TS5A3166DBVR

Texas Instruments

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER