Send an Inquiry

To receive a quote for your project, please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Part Number*
Quantity*
Message
Submit Inventory List

Please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Upload My List
Message

Analog Devices Inc./Maxim Integrated MAX6377UR24-T

Part No.:
MAX6377UR24-T
Manufacturer:
Analog Devices Inc./Maxim Integrated
Category:
Supervisors
Package:
TO-236-3, SC-59, SOT-23-3
Datasheet:
AetrixMAX6377UR24-T.pdf
Description:
IC SUPERVISOR UL LO PWR VOLT DET
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:7,500

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

MAX6377UR24-T from Maxim Integrated is an ultra-low-power, open-drain, active-low voltage detector designed for precision supply monitoring in battery-powered systems. It features a factory-trimmed 2.400V threshold (±2.5% over temperature), 500nA supply current, and operates from 1.2V to 5.5V VCC. It asserts OUT low when VCC falls below threshold and is used in portable equipment power sequencing and Li+-battery undervoltage lockout.

For engineers reviewing the MAX6377UR24-T datasheet, MAX6377UR24-T pinout, MAX6377UR24-T application, or MAX6377UR24-T equivalent, this page delivers verified electrical parameters, SOT23-3 package details, reset timing behavior, transient immunity specs, and validated alternative parts for supply monitoring designs requiring sub-1µA quiescent current and ±2.5% threshold accuracy.

Technical Context

The MAX6377UR24-T implements a precision bandgap reference and comparator with internally trimmed resistors to set its 2.400V detection threshold. Its open-drain output requires an external pull-up and sinks up to 100µA while asserted, enabling flexible logic-level interfacing across 1.2V–5.5V domains.

It guarantees correct output state down to 1V VCC and rejects fast transients via built-in hysteresis (100mV typical) and propagation delay filtering (20µs typical at +25°C). Threshold accuracy is maintained over –40°C to +85°C with ±2.5% tolerance and 40ppm/°C tempco.

Key Specifications

Parameter Value and Actual Design Meaning
Reset Threshold 2.400V ±2.5% (TA = –40°C to +85°C); ensures reliable brownout detection at nominal 2.4V system rails
Supply Current 500nA (typical); enables multi-year operation on coin-cell batteries in always-on monitoring circuits
Output Type Active-low, open-drain; allows wired-OR configuration and level-shifting with external pull-up to any voltage ≤5.5V
VCC Range 1.2V to 5.5V; supports operation during deep battery discharge and across diverse supply domains
Propagation Delay 20µs (typical, falling edge); provides deterministic response time for critical power-fail signaling
Threshold Hysteresis 100mV (typical); prevents output chatter during slow VCC recovery near trip point
Operating Temp –40°C to +85°C; qualified for industrial and extended-temperature portable applications

Pinout & Package

MAX6377UR24-T is housed in a 3-pin SOT23-3 package (JEDEC MO-178AA), footprint-compatible with SC70-3 but with higher power dissipation rating (320mW at +70°C).

Pin/Terminal Circuit Role Design Meaning
1 GND Ground reference for internal bandgap and comparator; must be low-impedance connection to system ground plane
2 OUT Open-drain active-low output; sinks current when VCC < VTH; requires external pull-up resistor for logic-high state
3 VCC Supply input; powers internal circuitry and defines monitored voltage rail; accepts 1.2V–5.5V

Key Features

Feature Design Value
Ultra-low ICC 500nA typical supply current enables >10-year battery life in coin-cell–powered IoT sensors
No external components Factory-trimmed threshold eliminates calibration resistors and reduces BOM count and layout area
Transient immunity Rejects negative VCC glitches up to 200µs duration (at 100mV overdrive), improving system robustness
Wide VCC range Operates from 1.2V to 5.5V, supporting direct monitoring of Li+ cells, LDO outputs, and logic supplies
Guaranteed state down to 1V Ensures predictable reset assertion even during severe brownout conditions before full power loss

Applications

Portable Medical Sensors Industrial Data Loggers

Use Scenario: Continuous glucose monitor powered by CR2032 battery with regulated 3.0V rail.

IC Role / Device Role / Timing Role: Voltage detector asserting microcontroller reset when battery drops below 2.4V to prevent corrupted memory writes.

Use Value: 500nA ICC extends usable battery life beyond 3 years; ±2.5% threshold ensures consistent low-battery cutoff across temperature.

Use Scenario: Remote environmental logger using Li-SOCl₂ primary cell with 3.6V nominal output.

IC Role / Device Role / Timing Role: Monitors main supply and triggers controlled shutdown sequence before voltage collapse.

Use Value: Open-drain output interfaces directly to 3.3V MCU GPIO; 20µs propagation delay enables timely firmware-initiated save operations.

Wearables Power Sequencing Smart Meter Backup Circuits

Use Scenario: Fitness tracker with dual-rail power (1.8V core, 3.3V I/O) and coin-cell backup.

IC Role / Device Role / Timing Role: Detects main supply failure and asserts enable signal to load switch controlling backup rail.

Use Value: 100mV hysteresis prevents oscillation during gradual battery decay; SOT23-3 footprint minimizes PCB area.

Use Scenario: Electricity meter with supercapacitor backup that must retain RTC and metering data during AC outage.

IC Role / Device Role / Timing Role: Supervises supercap voltage and initiates data flush to nonvolatile memory before backup depletion.

Use Value: Guaranteed operation down to 1V VCC ensures final reset assertion even as supercap discharges to 1.2V.

Equivalent & Alternatives

The following parts are listed as comparable options for similar voltage detector applications.

Alternative Part Technical Difference Application Difference Selection Advice
TLV803EB24DBZR 2.4V threshold, 350nA ICC, SOT23-3, push-pull active-low output Push-pull eliminates need for external pull-up; lower ICC but no open-drain flexibility Select when board space allows no external resistor and logic interface requires driven high state
APX803S-24SA-7 2.4V threshold, 800nA ICC, SOT23-3, open-drain active-low output, 1.1V min VCC Slightly higher ICC; wider VCC range (0.9V–6.0V); same pinout and function Select when operating below 1.2V VCC is required or when sourcing from alternate qualified suppliers

Compared with MAX6377UR24-T, TLV803EB24DBZR offers lower ICC and push-pull drive but sacrifices open-drain interoperability, while APX803S-24SA-7 matches pinout and open-drain function with broader VCC range at modest ICC trade-off - both serve as functional alternatives where design constraints permit.

Availability

MAX6377UR24-T is available at Aetrix Electronics and suitable for portable medical sensors, industrial data loggers, wearables power sequencing, and smart meter backup circuits requiring stable component supply, long-term lifecycle support, and guaranteed lead-free compliance.

Supply support for MAX6377UR24-T includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

Maxim Integrated (now part of Analog Devices) designs precision analog, mixed-signal, and power management ICs for demanding industrial, automotive, and computing applications.

The MAX6375–MAX6380 family was developed specifically for ultra-low-power supply monitoring in battery-critical systems, emphasizing sub-µA quiescent current, factory-trimmed accuracy, and transient-immune reset generation in minimal 3-pin packages.

FAQ

What is the exact reset threshold voltage of the MAX6377UR24-T?

The MAX6377UR24-T has a factory-trimmed nominal reset threshold of 2.400V, with guaranteed tolerance of ±2.5% over the full operating temperature range (–40°C to +85°C). At +25°C, the typical threshold is 2.400V, and the minimum/maximum values are 2.340V and 2.460V respectively, as specified in Table 1 of the datasheet.

Does the MAX6377UR24-T require an external pull-up resistor on its OUT pin?

Yes, the MAX6377UR24-T features an open-drain active-low output, so an external pull-up resistor is mandatory to establish a valid logic-high state when the output is not asserted. The pull-up can connect to any supply up to 5.5V, and its value must ensure VOL ≤0.4V at ISINK = 100µA while meeting downstream input leakage requirements.

What is the minimum VCC voltage at which the MAX6377UR24-T guarantees correct output logic state?

The MAX6377UR24-T guarantees correct output logic state (i.e., OUT remains low when VCC < VTH, high otherwise) down to 1.0V VCC. This ensures reliable reset assertion even during deep brownout conditions well below its 2.4V threshold, supporting fail-safe shutdown in low-voltage battery systems.

How does the MAX6377UR24-T handle fast transients on the VCC line?

The MAX6377UR24-T incorporates internal filtering to reject fast negative-going VCC transients. Per the Typical Operating Characteristics graph, it ignores glitches shorter than ~200µs when the overdrive (VTH – VCC) is 100mV, increasing immunity as overdrive grows. This prevents false resets caused by switching noise or load transients.

Is the MAX6377UR24-T available in lead-free packaging?

Yes, the MAX6377UR24-T is available in lead-free packaging. To order the lead-free version, replace the "-T" suffix with "+T", resulting in MAX6377UR24+T. Both versions share identical electrical specifications and SOT23-3 mechanical dimensions, with lead-free construction compliant with RoHS directives.

MAX6377UR24-T Specifications

Product attributes
Attribute value
Manufacturer:
Analog Devices Inc./Maxim Integrated
Series:
-
Package/Case:
TO-236-3, SC-59, SOT-23-3
Packaging:
Bulk
Product Status:
Active
Programmable:
Not Verified
Type:
Voltage Detector
Number of Voltages Monitored:
1
Voltage - Threshold:
2.4V
Output:
Open Drain or Open Collector
Reset:
Active Low
Reset Timeout:
-
Operating Temperature:
-40°C ~ 85°C (TA)
Grade:
-
Qualification:
-
Mounting Type:
Surface Mount
Supplier Device Package:
SOT-23-3

MAX6377UR24-T FAQ

1.How can I place an order for MAX6377UR24-T through Aetrix?

Please submit a Request for Quotation (RFQ) for MAX6377UR24-T on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for MAX6377UR24-T reliable?

The price and inventory of MAX6377UR24-T are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MAX6377UR24-T is usually 5 days.

3.What payment methods are accepted for MAX6377UR24-T?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MAX6377UR24-T transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for MAX6377UR24-T?

MAX6377UR24-T orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your MAX6377UR24-T order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for MAX6377UR24-T?

For technical support, including MAX6377UR24-T datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MAX6377UR24-T requirements.

6.How does Aetrix verify that MAX6377UR24-T is sourced from the original manufacturer or authorized distributors?

All MAX6377UR24-T products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MAX6377UR24-T meets industry standards.

7.What is the process for return or replacement of MAX6377UR24-T?

All MAX6377UR24-T units undergo pre-shipment inspection (PSI). If there is an issue with MAX6377UR24-T, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The MAX6377UR24-T part is unused and in its original packaging.

Return procedure for MAX6377UR24-T:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

MAX6377UR24-T Tags

  • MAX6377UR24-T
  • MAX6377UR24-T PDF
  • MAX6377UR24-T Datasheet
  • MAX6377UR24-T Specifications
  • MAX6377UR24-T Images
  • Analog Devices Inc./Maxim Integrated
  • Analog Devices Inc./Maxim Integrated MAX6377UR24-T
  • Buy MAX6377UR24-T
  • MAX6377UR24-T Price
  • MAX6377UR24-T Distributor
  • MAX6377UR24-T Supplier
  • MAX6377UR24-T Wholesale
Related Products
MIC826SYMT-TR
MIC826SYMT-TR

Microchip Technology

APX803S-31SA-7
APX803S-31SA-7

Diodes Incorporated

APX803L20-29SA-7
APX803L20-29SA-7

Diodes Incorporated

TPS3828-33DBVR
TPS3828-33DBVR

Texas Instruments

V6340RSP3B+
V6340RSP3B+

EM Microelectronic

EM6325CXSP5B-2.9+
EM6325CXSP5B-2.9+

EM Microelectronic

MCP120T-300I/TT
MCP120T-300I/TT

Microchip Technology

MCP130T-315I/TT
MCP130T-315I/TT

Microchip Technology

MCP120T-475I/TT
MCP120T-475I/TT

Microchip Technology

MCP111T-300E/TT
MCP111T-300E/TT

Microchip Technology

MCP120T-315I/TT
MCP120T-315I/TT

Microchip Technology

MCP809T-315I/TT
MCP809T-315I/TT

Microchip Technology

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER