Analog Devices Inc./Maxim Integrated MAX6377UR26+
- Part No.:
- MAX6377UR26+
- Manufacturer:
- Analog Devices Inc./Maxim Integrated
- Category:
- Supervisors
- Package:
- TO-236-3, SC-59, SOT-23-3
- Datasheet:
-
MAX6377UR26+.pdf
- Description:
- IC SUPERVISOR UL LO PWR VOLT DET
- Quantity:
- Payment:

- Shipping:

Inventory:2,863
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MAX6377UR26+ from Maxim Integrated is an ultra-low-power, open-drain, active-low voltage detector designed for precision supply monitoring in battery-powered systems. It features a factory-trimmed 2.63V threshold (±2.5% over temperature), 500nA supply current, and operates from 1.2V to 5.5V VCC. Used in portable equipment for reset assertion during brownout conditions.
For engineers reviewing the MAX6377UR26+ datasheet, MAX6377UR26+ pinout, MAX6377UR26+ application, or MAX6377UR26+ equivalent, key selection criteria include its 2.63V trip point, open-drain output architecture, SC70/SOT23-3 package compatibility, transient immunity up to 200µs at 100mV overdrive, and guaranteed logic state down to 1V VCC.
Technical Context
The MAX6377UR26+ implements a precision bandgap reference and comparator with internally trimmed resistors to set its 2.63V detection threshold. Its open-drain output requires an external pull-up and asserts low when VCC falls below VTH, remaining valid down to 1V supply.
It delivers 500nA typical supply current and ±2.5% threshold accuracy across –40°C to +85°C. Propagation delay is 6.3µs (falling edge) and it rejects transients ≤200µs at 100mV overdrive, ensuring robust operation in noisy power environments.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Reset Threshold | 2.63V nominal, ±2.5% over –40°C to +85°C - ensures reliable brownout detection across industrial temperature range |
| Supply Current | 500nA typical - enables multi-year battery life in coin-cell–powered devices |
| Output Type | Active-low, open-drain - supports flexible logic-level interfacing via external pull-up to any voltage ≤5.5V |
| VCC Operating Range | 1.2V to 5.5V - guarantees correct output state even during deep undervoltage conditions |
| Propagation Delay | 6.3µs (falling), 9.5µs (rising) - provides fast, deterministic reset timing for microcontrollers |
| Threshold Hysteresis | 100mV - prevents chatter during slow-rising/falling supply transitions |
| Transient Immunity | Rejects negative VCC glitches ≤200µs at 100mV overdrive - eliminates false resets in noisy DC/DC environments |
Pinout & Package
MAX6377UR26+ is packaged in a 3-pin SOT23-3 (lead-free, marked "FZHC") with standard pinout: Pin 1 = GND, Pin 2 = OUT (open-drain), Pin 3 = VCC.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 | GND | Reference ground return for internal bandgap and comparator - must be low-impedance connection to system ground |
| 2 | OUT | Open-drain active-low output - sinks current when asserted; requires external pull-up resistor for logic-level translation |
| 3 | VCC | Supply input - powers internal circuitry and defines detection domain; functional down to 1.2V, valid output state guaranteed to 1V |
Key Features
| Feature | Design Value |
|---|---|
| Ultra-low ICC | 500nA enables >10-year battery life in always-on IoT sensors using CR2032 cells |
| Factory-trimmed VTH | 2.63V threshold with ±2.5% tolerance eliminates need for external resistor networks or calibration |
| Open-drain output | Allows level-shifting to 1.8V, 3.3V, or 5V logic domains without additional interface ICs |
| 1V minimum VCC operation | Ensures clean reset assertion even during deep battery discharge or LDO dropout |
| Transient rejection | Immune to sub-200µs supply glitches - avoids spurious resets in switching regulator applications |
Applications
| Portable Medical Sensors | Industrial Telemetry Nodes |
|---|---|
|
Use Scenario: Continuous glucose monitor powered by CR2032 battery with regulated 3.0V rail. IC Role / Device Role / Timing Role: Voltage detector asserting /RESET to microcontroller when battery drops below 2.63V. Use Value: Prevents data corruption and firmware lockup by guaranteeing clean reset before brownout-induced logic failure. |
Use Scenario: Wireless sensor node in remote oil-field monitoring, operating on Li-ion with wide-temperature exposure. IC Role / Device Role / Timing Role: Supervisory circuit triggering controlled shutdown when DC/DC output falls below 2.63V. Use Value: Enables graceful firmware save-to-EEPROM and RF transmission completion prior to power loss. |
| Wearables with Low-Power MCU | Smart Meter Backup Power Monitoring |
|
Use Scenario: Fitness tracker using ARM Cortex-M0+ MCU with 1.8V I/O and 2.6V core supply. IC Role / Device Role / Timing Role: Reset supervisor interfaced via 1.8V pull-up to ensure compatible logic levels. Use Value: Eliminates need for level translators while maintaining <500nA system quiescent current. |
Use Scenario: Electricity meter with supercapacitor backup powering real-time clock and nonvolatile memory. IC Role / Device Role / Timing Role: Detects supercapacitor voltage decay to initiate RTC switchover and memory write protection. Use Value: Guarantees data integrity during main power loss with no external components or trimming required. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar voltage detector applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| TLV803EC26DBZR | 2.63V threshold, 350nA ICC, SOT23-3, push-pull active-low output | Push-pull eliminates need for external pull-up but limits logic-level flexibility | Select when system uses single-rail logic and board space allows no extra resistor |
| APX803S-26SA-7 | 2.63V threshold, 800nA ICC, SOT23-3, open-drain active-low output, wider temp range (–40°C to +125°C) | Better high-temp performance but higher supply current reduces battery life | Select for automotive under-hood or industrial high-temp deployments where 500nA is not critical |
Compared with TLV803EC26DBZR and APX803S-26SA-7, the MAX6377UR26+ uniquely balances ultra-low 500nA current, open-drain flexibility, and industrial-grade temperature stability - making it optimal for long-life portable electronics where both power and interface adaptability matter.
Availability
MAX6377UR26+ is available at Aetrix Electronics and suitable for portable medical sensors, industrial telemetry nodes, wearables with low-power MCU, and smart meter backup power monitoring requiring stable component supply and long-term manufacturability.
Supply support for MAX6377UR26+ includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Maxim Integrated (now part of Analog Devices) designs precision analog and mixed-signal ICs for power, sensing, and connectivity in demanding industrial, medical, and communications applications.
The MAX6375–MAX6380 family was engineered specifically for ultra-low-power voltage supervision in battery-critical systems - delivering factory-trimmed thresholds, nanoscale supply current, and transient-hardened operation in minimal 3-pin packages.
FAQ
What is the exact reset threshold voltage of the MAX6377UR26+?
The MAX6377UR26+ has a factory-trimmed nominal reset threshold of 2.63V, with ±2.5% accuracy over the full –40°C to +85°C operating temperature range. This value is confirmed in Table 1 of the datasheet under suffix "R26", and applies specifically to the MAX6377UR26+ variant - not the broader MAX6377 family.
Does the MAX6377UR26+ require an external pull-up resistor on its OUT pin?
Yes, the MAX6377UR26+ features an open-drain output and requires an external pull-up resistor to establish a defined high logic level. The datasheet specifies that the pull-up may connect to any supply up to 5.5V, and recommends selecting a resistor value that ensures VOL ≤0.4V at ISINK = 100µA while meeting system rise-time requirements.
What is the minimum VCC voltage at which the MAX6377UR26+ guarantees correct output logic state?
The MAX6377UR26+ guarantees correct output logic state - i.e., OUT remains high when VCC ≥ VTH and asserts low when VCC < VTH - down to 1V VCC. This is explicitly stated in the General Description and verified across the full temperature range, enabling reliable operation during deep battery discharge.
Can the MAX6377UR26+ be used in place of the MAX6375UR26+?
No - the MAX6377UR26+ and MAX6375UR26+ differ in output configuration: MAX6377UR26+ has open-drain output, while MAX6375UR26+ has push-pull. They share the same 2.63V threshold and pinout, but substituting one for the other requires verifying whether the target system expects active-low open-drain (requires pull-up) or active-low push-pull (no pull-up needed).
What package type and marking code does the MAX6377UR26+ use?
The MAX6377UR26+ is supplied in a lead-free 3-pin SOT23-3 package with top-marking code "FZHC". This marking is confirmed in Table 2 of the datasheet under "MAX6377_R26-T" (leaded) and "MAX6377UR26+" (lead-free), and matches the SOT23-3 outline drawing (21-0051).
MAX6377UR26+ Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Analog Devices Inc./Maxim Integrated
- Series:
- -
- Package/Case:
- TO-236-3, SC-59, SOT-23-3
- Packaging:
- Bulk
- Product Status:
- Obsolete
- Programmable:
- Not Verified
- Type:
- Voltage Detector
- Number of Voltages Monitored:
- 1
- Voltage - Threshold:
- 2.63V
- Output:
- Open Drain or Open Collector
- Reset:
- Active Low
- Reset Timeout:
- -
- Operating Temperature:
- -40°C ~ 85°C (TA)
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Surface Mount
- Supplier Device Package:
- SOT-23-3
MAX6377UR26+ FAQ
1.How can I place an order for MAX6377UR26+ through Aetrix?
Please submit a Request for Quotation (RFQ) for MAX6377UR26+ on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MAX6377UR26+ reliable?
The price and inventory of MAX6377UR26+ are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MAX6377UR26+ is usually 5 days.
3.What payment methods are accepted for MAX6377UR26+?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MAX6377UR26+ transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MAX6377UR26+?
MAX6377UR26+ orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MAX6377UR26+ order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MAX6377UR26+?
For technical support, including MAX6377UR26+ datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MAX6377UR26+ requirements.
6.How does Aetrix verify that MAX6377UR26+ is sourced from the original manufacturer or authorized distributors?
All MAX6377UR26+ products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MAX6377UR26+ meets industry standards.
7.What is the process for return or replacement of MAX6377UR26+?
All MAX6377UR26+ units undergo pre-shipment inspection (PSI). If there is an issue with MAX6377UR26+, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MAX6377UR26+ part is unused and in its original packaging.
Return procedure for MAX6377UR26+:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MAX6377UR26+ Tags

-
MIC826SYMT-TR
Microchip Technology

-
APX803S-31SA-7
Diodes Incorporated

-
APX803L20-29SA-7
Diodes Incorporated
-
TPS3828-33DBVR
Texas Instruments

-
V6340RSP3B+
EM Microelectronic

-
EM6325CXSP5B-2.9+
EM Microelectronic

-
MCP120T-300I/TT
Microchip Technology

-
MCP130T-315I/TT
Microchip Technology

-
MCP120T-475I/TT
Microchip Technology

-
MCP111T-300E/TT
Microchip Technology

-
MCP120T-315I/TT
Microchip Technology

-
MCP809T-315I/TT
Microchip Technology
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…

